Loading...
HomeMy WebLinkAboutFinn Residence - Manual JCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-21 10:52:58 Ri g ht-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 1 ...er\Documents\Wrightsoft HVAC\Finn Residence.rup Calc = MJ8 Front Door faces: E Job:Project Summary Date:Entire House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com Project Information Jason & Lisa FinnFor:TBD S 25th Street, Fort Pierce, FL 34981 Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F15Daily range M Relative humidity %50Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh34596 Structure Btuh30402 Ducts Btuh6368 Ducts Btuh4355Central vent (0 cfm)Btuh0 Central vent (0 cfm)Btuh0 (none)(none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh40964 Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load Btuh33019 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh4572 Ducts Btuh3397Central vent (0 cfm)Btuh0 CoolingHeating (none)24152415Area (ft²)Equipment latent load Btuh7969 2488324883Volume (ft³)Air changes/hour 0.160.32 Equipment Total Load (Sen+Lat)Btuh40989 Equiv. AVF (cfm)66133 Req. total capacity at 0.70 SHR ton3.9 Heating Equipment Summary Cooling Equipment Summary Make Make TraneTradeTradeTRANE Model Cond 4TTR7048B1AHRI ref Coil TAM9A0C42V41 AHRI ref 202274119Efficiency100 EFF Efficiency 13.0 EER, 17 SEER Heating input kW11.9 Sensible cooling Btuh32550Heating output Btuh40521 Latent cooling Btuh13950 Temperature rise °F24 Total cooling Btuh46500Actual air flow cfm1550 Actual air flow cfm1550 Air flow factor cfm/Btuh0.038 Air flow factor cfm/Btuh0.045Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-21 10:52:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 1...er\Documents\Wrightsoft HVAC\Finn Residence.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Entire House Master Suite 2 Exposed wall 241.0 ft 33.0 ft 3 Room height 10.3 ft 11.0 heat/coolft 4 Room dimensions ft313.0x1.0 5 Room area 2414.5 ft²313.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-5ocs13A-5ocs 0.1250.125 nn 3.503.50 1.911.91 651 621 2174 1188 11 11 39 21 .GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 30 0 1067 792 0 0 0 0 .WW 13A-5ocs13A-5ocs 0.1250.125 ee 3.503.50 1.911.91 430 314 1099 601 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 28.4928.49 8 7 284 228 0 0 0 0 1 1 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 30 2 1067 1524 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 26.3926.39 30 30 1067 792 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 48 48 524 496 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ss 3.503.50 1.911.91 666 593 2077 1135 176 156 546 298 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 20 20 711 528 20 20 711 528 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 30 30 1067 792 0 0 0 0 DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 23 23 248 234 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ww 3.503.50 1.911.91 718 544 1904 1040 176 128 448 245 GG 10A-m10A-m 1.6701.670 ww 46.7646.76 51.9351.93 48 2 2244 2493 48 2 2244 2493 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 30 2 1067 1524 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ww 35.5635.56 29.6729.67 96 84 3414 2849 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 2413 2413 3826 3301 313 313 496 428 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 2413 241 6674 0 313 33 914 0 6 c) AED excursion 3424 809 Envelope loss/gain 30512 22938 5398 4821 12 a)Infiltration 4084 1094 601 161 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 9 2070 2 460 Appliances/other 4300 900 Subtotal (lines 6 to 13)34596 30402 6000 6343 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 34596 30402 6000 6343 15 Duct loads 18%14%6368 4355 18%14%1104 909 Total room load 40964 34757 7104 7251 Air required (cfm)Air required (cfm)1550 1550 269 323 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-21 10:52:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 2...er\Documents\Wrightsoft HVAC\Finn Residence.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name WIC 1 Toilet 2 Exposed wall 13.0 ft 4.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft13.0x6.0 ft4.0x6.0 5 Room area 78.0 ft²24.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-5ocs13A-5ocs 0.1250.125 nn 3.503.50 1.911.91 0 0 0 0 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 .WW 13A-5ocs13A-5ocs 0.1250.125 ee 3.503.50 1.911.91 0 0 0 0 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 28.4928.49 0 0 0 0 0 0 0 0 1 1 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ss 3.503.50 1.911.91 130 130 455 249 40 40 140 76 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ww 3.503.50 1.911.91 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 ww 46.7646.76 51.9351.93 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ww 35.5635.56 29.6729.67 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 78 78 124 107 24 24 38 33 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 78 13 360 0 24 4 111 0 6 c) AED excursion -11 -3 Envelope loss/gain 939 344 289 106 12 a)Infiltration 215 58 66 18 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1154 402 355 124 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1154 402 355 124 15 Duct loads 18%14%212 58 18%14%65 18 Total room load 1366 460 420 141 Air required (cfm)Air required (cfm)52 20 16 6 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-21 10:52:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 3...er\Documents\Wrightsoft HVAC\Finn Residence.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name M BAth M WIC 2 2 Exposed wall 40.0 ft 6.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft212.0x1.0 ft6.0x6.0 5 Room area 212.0 ft²36.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-5ocs13A-5ocs 0.1250.125 nn 3.503.50 1.911.91 140 140 490 268 60 60 210 115 .GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 .WW 13A-5ocs13A-5ocs 0.1250.125 ee 3.503.50 1.911.91 160 130 455 249 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 28.4928.49 0 0 0 0 0 0 0 0 1 1 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 30 2 1067 1524 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ss 3.503.50 1.911.91 100 100 350 191 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ww 3.503.50 1.911.91 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 ww 46.7646.76 51.9351.93 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ww 35.5635.56 29.6729.67 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 212 212 336 290 36 36 57 49 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 212 40 1108 0 36 6 166 0 6 c) AED excursion -72 -5 Envelope loss/gain 3806 2449 433 159 12 a)Infiltration 663 178 99 27 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)4468 2627 533 186 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 4468 2627 533 186 15 Duct loads 18%14%822 376 18%14%98 27 Total room load 5291 3003 631 212 Air required (cfm)Air required (cfm)200 134 24 9 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-21 10:52:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 4...er\Documents\Wrightsoft HVAC\Finn Residence.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Foyer Great Room 2 Exposed wall 16.0 ft 22.0 ft 3 Room height 10.0 heat/coolft 11.0 heat/coolft 4 Room dimensions ft5.0x16.0 ft17.0x25.0 5 Room area 80.0 ft²425.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-5ocs13A-5ocs 0.1250.125 nn 3.503.50 1.911.91 0 0 0 0 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 .WW 13A-5ocs13A-5ocs 0.1250.125 ee 3.503.50 1.911.91 160 82 287 157 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 28.4928.49 0 0 0 0 0 0 0 0 1 1 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 26.3926.39 30 30 1067 792 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 48 48 524 496 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ss 3.503.50 1.911.91 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ww 3.503.50 1.911.91 0 0 0 0 242 146 511 279 GG 10A-m10A-m 1.6701.670 ww 46.7646.76 51.9351.93 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ww 35.5635.56 29.6729.67 0 0 0 0 96 84 3414 2849 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 80 80 127 109 425 425 674 581 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 80 16 443 0 425 22 609 0 6 c) AED excursion -43 2534 Envelope loss/gain 2448 1511 5208 6243 12 a)Infiltration 265 71 401 107 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 2 460 Appliances/other 0 900 Subtotal (lines 6 to 13)2713 1582 5609 7711 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 2713 1582 5609 7711 15 Duct loads 18%14%499 227 18%14%1032 1105 Total room load 3212 1808 6641 8815 Air required (cfm)Air required (cfm)122 81 251 393 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-21 10:52:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 5...er\Documents\Wrightsoft HVAC\Finn Residence.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Dining Laundry 2 Exposed wall 25.0 ft 15.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft12.0x13.0 ft9.0x13.0 5 Room area 156.0 ft²117.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-5ocs13A-5ocs 0.1250.125 nn 3.503.50 1.911.91 0 0 0 0 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 .WW 13A-5ocs13A-5ocs 0.1250.125 ee 3.503.50 1.911.91 0 0 0 0 110 102 357 195 .GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 28.4928.49 0 0 0 0 8 7 284 228 1 1 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ss 3.503.50 1.911.91 120 90 315 172 40 40 140 76 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 30 30 1067 792 0 0 0 0 DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ww 3.503.50 1.911.91 130 100 350 191 0 0 0 0 GG 10A-m10A-m 1.6701.670 ww 46.7646.76 51.9351.93 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 30 2 1067 1524 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ww 35.5635.56 29.6729.67 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 156 156 247 213 117 117 186 160 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 156 25 692 0 117 15 415 0 6 c) AED excursion 429 -33 Envelope loss/gain 3738 3321 1382 627 12 a)Infiltration 414 111 249 67 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13)4152 3662 1631 1193 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 29 24 49 41 14 Subtotal 4181 3686 1680 1234 15 Duct loads 18%14%770 528 18%14%309 177 Total room load 4951 4214 1989 1411 Air required (cfm)Air required (cfm)187 188 75 63 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-21 10:52:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 6...er\Documents\Wrightsoft HVAC\Finn Residence.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Hall 2 Bedroom 3 2 Exposed wall 0 ft 12.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft12.0x4.0 ft12.0x13.0 5 Room area 48.0 ft²156.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-5ocs13A-5ocs 0.1250.125 nn 3.503.50 1.911.91 0 0 0 0 120 105 368 201 .GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 15 0 533 396 .WW 13A-5ocs13A-5ocs 0.1250.125 ee 3.503.50 1.911.91 0 0 0 0 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 28.4928.49 0 0 0 0 0 0 0 0 1 1 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ss 3.503.50 1.911.91 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ww 3.503.50 1.911.91 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 ww 46.7646.76 51.9351.93 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ww 35.5635.56 29.6729.67 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 48 48 76 66 156 156 247 213 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 48 0 0 0 156 12 332 0 6 c) AED excursion -2 -29 Envelope loss/gain 76 64 1481 781 12 a)Infiltration 0 0 199 53 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13)76 64 1679 1064 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -76 -64 29 24 14 Subtotal 0 0 1708 1088 15 Duct loads 18%14%0 0 18%14%314 156 Total room load 0 0 2022 1244 Air required (cfm)Air required (cfm)0 0 77 55 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-21 10:52:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 7...er\Documents\Wrightsoft HVAC\Finn Residence.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name WIC 2 Pantry 2 Exposed wall 6.0 ft 0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft6.1x6.0 ft6.0x9.0 5 Room area 36.5 ft²54.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-5ocs13A-5ocs 0.1250.125 nn 3.503.50 1.911.91 60 60 210 115 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 .WW 13A-5ocs13A-5ocs 0.1250.125 ee 3.503.50 1.911.91 0 0 0 0 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 28.4928.49 0 0 0 0 0 0 0 0 1 1 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ss 3.503.50 1.911.91 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ww 3.503.50 1.911.91 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 ww 46.7646.76 51.9351.93 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ww 35.5635.56 29.6729.67 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 36 36 57 49 54 54 86 74 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 36 6 166 0 54 0 0 0 6 c) AED excursion -5 -2 Envelope loss/gain 433 159 86 72 12 a)Infiltration 99 27 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)533 186 86 72 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 5 4 14 Subtotal 533 186 90 76 15 Duct loads 18%14%98 27 18%14%17 11 Total room load 631 212 107 87 Air required (cfm)Air required (cfm)24 9 4 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-21 10:52:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 8...er\Documents\Wrightsoft HVAC\Finn Residence.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Bedroom 2 Bath2 2 Exposed wall 11.0 ft 9.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft11.0x15.0 ft9.1x12.0 5 Room area 165.0 ft²109.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-5ocs13A-5ocs 0.1250.125 nn 3.503.50 1.911.91 110 95 333 182 90 90 315 172 .GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 15 0 533 396 0 0 0 0 .WW 13A-5ocs13A-5ocs 0.1250.125 ee 3.503.50 1.911.91 0 0 0 0 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 28.4928.49 0 0 0 0 0 0 0 0 1 1 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ss 3.503.50 1.911.91 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ww 3.503.50 1.911.91 0 0 0 0 0 0 0 0 GG 10A-m10A-m 1.6701.670 ww 46.7646.76 51.9351.93 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ww 35.5635.56 29.6729.67 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 165 165 262 226 108 108 171 148 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 165 11 305 0 108 9 249 0 6 c) AED excursion -29 -10 Envelope loss/gain 1432 774 735 310 12 a)Infiltration 182 49 149 40 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1614 1053 885 350 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 16 14 49 41 14 Subtotal 1631 1067 933 391 15 Duct loads 18%14%300 153 18%14%172 56 Total room load 1931 1220 1105 447 Air required (cfm)Air required (cfm)73 54 42 20 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-21 10:52:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 9...er\Documents\Wrightsoft HVAC\Finn Residence.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Hall WIC 3 2 Exposed wall 0 ft 12.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft9.0x11.0 ft6.0x6.0 5 Room area 99.0 ft²36.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-5ocs13A-5ocs 0.1250.125 nn 3.503.50 1.911.91 0 0 0 0 60 60 210 115 .GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 .WW 13A-5ocs13A-5ocs 0.1250.125 ee 3.503.50 1.911.91 0 0 0 0 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 28.4928.49 0 0 0 0 0 0 0 0 1 1 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ss 3.503.50 1.911.91 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ww 3.503.50 1.911.91 0 0 0 0 60 60 210 115 GG 10A-m10A-m 1.6701.670 ww 46.7646.76 51.9351.93 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ww 35.5635.56 29.6729.67 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 99 99 157 135 36 36 57 49 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 99 0 0 0 36 12 332 0 6 c) AED excursion -4 -9 Envelope loss/gain 157 132 809 270 12 a)Infiltration 0 0 199 53 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)157 132 1008 323 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -157 -132 0 0 14 Subtotal 0 0 1008 323 15 Duct loads 18%14%0 0 18%14%186 46 Total room load 0 0 1194 369 Air required (cfm)Air required (cfm)0 0 45 16 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jan-21 10:52:58Right-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 10...er\Documents\Wrightsoft HVAC\Finn Residence.rup Calc = MJ8 Front Door faces: E Job:Right-J® Worksheet Date:Entire House By:Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com 1 Room name Bath 3 Kitchen 2 Exposed wall 17.0 ft 0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft6.0x11.0 ft17.0x12.0 5 Room area 66.0 ft²204.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh /ft²-°F)(Btuh /ft²-°F)(Btuh /ft²)(Btuh /ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-5ocs13A-5ocs 0.1250.125 nn 3.503.50 1.911.91 0 0 0 0 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 .WW 13A-5ocs13A-5ocs 0.1250.125 ee 3.503.50 1.911.91 0 0 0 0 0 0 0 0 .GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 28.4928.49 0 0 0 0 0 0 0 0 1 1 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ss 3.503.50 1.911.91 60 37 131 71 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ss 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ss 10.9210.92 10.3410.34 23 23 248 234 0 0 0 0 WW 13A-5ocs13A-5ocs 0.1250.125 ww 3.503.50 1.911.91 110 110 385 210 0 0 0 0 GG 10A-m10A-m 1.6701.670 ww 46.7646.76 51.9351.93 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1omd1A-r1omd 1.2701.270 ww 35.5635.56 29.6729.67 0 0 0 0 0 0 0 0 CC 16X19-0md16X19-0md 0.4080.408 --1.591.59 1.371.37 66 66 105 90 204 204 323 279 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 66 17 471 0 204 0 0 0 6 c) AED excursion -18 -73 Envelope loss/gain 1339 588 323 206 12 a)Infiltration 282 75 0 0 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 2 460 Appliances/other 0 2000 Subtotal (lines 6 to 13)1620 664 323 2666 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 10 8 48 40 14 Subtotal 1630 672 372 2706 15 Duct loads 18%14%300 96 18%14%68 388 Total room load 1930 768 440 3094 Air required (cfm)Air required (cfm)73 34 17 138 2021-Jan-21 10:52:59 Ri g ht-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 1 ...er\Documents\Wrightsoft HVAC\Finn Residence.rup Calc = MJ8 Front Door faces: E Job:Duct System Summary Date:Entire House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs@aol.com Project Information Jason & Lisa FinnFor: TBD S 25th Street, Fort Pierce, FL 34981 CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.250 / 0.250 in H2O in H2O0.250 / 0.250 Lowest friction rate in/100ft0.245in/100ft0.245 Actual air flow cfm1550cfm1550 Total effective length (TEL)ft204 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st5155.049.3VlFx0x06.00.24534731930hBath 3 st6155.024.3VlFx0x04.00.27920421105hBath2 st6155.024.7VlFx0x06.00.27854731931hBedroom 2 st5155.047.1VlFx0x06.00.24755772022hBedroom 3 st1115.036.9VlFx0x08.00.3291881874214cDining-A st4135.040.6VlFx0x07.00.285811223212hFoyer st4135.038.6VlFx0x08.00.2881971264408cGreat Room st4135.036.4VlFx0x08.00.2921971264408cGreat Room-A st1115.019.9VlFx0x07.00.371138173094cKitchen st1115.021.9VlFx0x06.00.36563751989hLaundry st8145.055.1VlFx0x08.00.2501342005291hM BAth st8145.054.1VlFx0x04.00.251924631hM WIC 2 st7125.049.2VlFx0x08.00.2871621343626cMaster Suite st7125.047.0VlFx0x08.00.2911621343626cMaster Suite-A st2135.028.8VlFx0x04.00.30544107hPantry st8145.056.2VlFx0x04.00.249616420hToilet st7125.048.8VlFx0x05.00.28820521366hWIC 1 st6155.031.5VlFx0x04.00.268924631hWIC 2 st5155.047.1VlFx0x05.00.24716451194hWIC 3 2021-Jan-21 10:52:59 Ri g ht-S ui te® Uni ve rsa l 2 019 19 .0 .2 1 RS U0 81 01 Page 2 ...er\Documents\Wrightsoft HVAC\Finn Residence.rup Calc = MJ8 Front Door faces: E Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st8 Peak AVF 240 150 0.249 543 9.0 0x0 VinlFlx st7 st7 Peak AVF 560 494 0.249 524 14.0 0x0 VinlFlx st3 st3 Peak AVF 560 494 0.249 524 14.0 0x0 VinlFlx st4 Peak AVF 373 474 0.285 603 12.0 0x0 VinlFlx st1 st1 Peak AVF 652 863 0.285 618 16.0 0x0 VinlFlx st5 Peak AVF 195 106 0.245 558 8.0 0x0 VinlFlx st2 st6 Peak AVF 139 84 0.268 519 7.0 0x0 VinlFlx st2 st2 Peak AVF 337 194 0.245 430 12.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb1 0x 15500 1550 0 0 0 0 x0 0 VlFx