Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) I. New construction or existing New (From Plans) 10. Wail Type$1432.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 c. NIA R= ft2 4. Number of Bedrooms 3 d. NIA R= ft2 5. Is this a worst case? Yes 11. Ceiling Types (1783.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1753,00 ft2 6. Conditioned floor area above grade (ft2) 1753 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= f12 7. Windows(151.4 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Sg[, U=1.02 111.36 ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 195 SHGC: SHGC=0.29 b. U-Factor: S91, U=1.11 40.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c- U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0185 a. Electric Heat Pump 34.8 HSPF:8.50 8- Skylights Area C. U-Factor:(AVG) N/A ft2 SHGC(AVG): NIA 15. Hot water systems 9. Floor Types (1753.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge insulation R=0.0 1753.00 ft2 b. Conservation features EF: 0.970 b. NIA R= ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.086 Total Proposed Modified Loads: 49,38 Total /'�'► PASS Baseline Loads: 50.69 hereby certify that the plans and specifications covered by Review of the plans and .1 TM ,q A„ this calculation are in compliance with the Florida Energy specifications covered by this Code. Calculation indicates compliance the q'0 '4 7 r� ' s a W with Florida Energy Code. ��t,(<<,,,�,, p PREPARED BY - 1-1 2-202 I Before construction is completed ga - 4 DATE: this building will be inspected forCA fINg U"11 compliance with Section 553.908 I hereby certify that this building, as designed, is in ompliance Florida Statutes. with the Florida Energy Code. WE OWNER/A BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Pagel of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 BlocWSubdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUORY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft- ___ 0 1 0 2Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 fF ___ 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft' _- 0 1 0 _ 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft' _- 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 ft- __ 0 1 0 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 IMPI IT RI IMMARV cuccirt tcT oconov FLOORS # Floor Type Space Perimeter Perimeter R-Value Area JoistR-ValueTile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 W 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft' 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 11 ft 0 209 ft' 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft2 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft' 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 it 0 92 ft- 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 W _ 0 1 0 ROOF / V Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC / # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft- N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft- 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft- 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft- 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft' 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 fi' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 W 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft' 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft' 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 T 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft- 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft' 0.1 Wood 13 Knee Wall (Vented) DINING/GREAT 19 Blown 30 ft' 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block - Int InsWASTER BE 4.1 16 0 8 0 128.0 ft' 0 0 0.3 0 2 SW=>NE Exterior Concrete Block- Int InsWASTER BE 4.1 7 0 8 0 56.0 ft' 0 0 0.3 0 3 NW=>SE Exterior Concrete Block - Int InsWASTER BE 4.1 14 0 8 0 112.0 ft' 0 0 0.3 0 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPI IT AI IMN7ARV CUGrIn icr 000nor WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 4 NE=>SW Exterior Concrete Block - Int Ins&IIASTER BA 4.1 8 0 8 0 64.0 ft- 0 0 0.3 0 5 NE=>SW Exterior Concrete Block - Int Insul M. BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.3 0 6 NE=>SW Exterior Concrete Block - Int InsBEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 7 SW=>NE Exterior Concrete Block- Int InsaINING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.3 0 8 NW=>SE Exterior Concrete Block -Int InsGINING/GRE 4.1 20 0 8 0 160.0 ft' 0 0 0.3 0 9 SW=>NE Exterior Concrete Block- Int InsulKITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.3 0 10 NE=>SW Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 W 0 0 0.3 0 11 SE=>NW Exterior Concrete Block -Int Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.3 0 12 SW=>NE Exterior Concrete Block - Int Insul FOYER 4.1 1 0 8 0 8.0 W 0 0 0.3 0 13 NE=>SW Exterior Concrete Block - Int InsSEDROOM 3 4.1 13 0 8 0 104.0 ft' 0 0 0.3 0 14 SW=>NE Exterior Concrete Block - Int InsBEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 _ 15 N=>S Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft' 0.23 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated FOYER None .39 3 3 6 8 21.7ft- WINDOWS Orientation shown is the entered orientation => than ed to Worst Case. / Wall V Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.02 0.29 Y 32.4 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>SW 5 Metal Low-E Single Yes 1.02 0.29 Y 6.9 ft' 1 ft 0 in 1 ft 4 in None None 3 NE=>SW 6 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft' 1 ft 0 in 1 ft 4 in None None 4 SW=>NE 7 Metal Low-E Single Yes 1.02 0.29 Y 39.8 ft' 1 ft 0 in 1 ft 4 in None None 5 NW=>SE 8 Metal Low-E Single Yes 1.11 0.27 Y 40.0 ft' 8 ft 0 in 1 ft 4 in None None 6 NE=>SW 13 Metal Low-E Single Yes 1.02 029 Y 16.2 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft- 806 W 26 ft aft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 64.12 120.37 .0902 5 1/12/2021 1:15 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 34.8 kBtu/hr ofm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply -- -- Return-- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 195 ft2 Attic 55 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling �r[X],J Jan �r[x],J Feb Heating Jan Feb Venting [�rx�j, Mar Mar r A r j Apr [ May IX� Jun �(l Jul rX� Aug May j j Jun [ j Jul j j Aug (Xl Sep [ j Sep Oct j j Oct [JC] Nov Nov (� Dec (XI Dec [ j Jan [ j Feb L 1 L J [X] Mar l^1 Apr [ May [ j Jun [ ]Jul [ j Aug (]Sep Oct [XJ Nov [ j Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. oft. 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M. BATH Default(81bs/sq.ft. ft2 ft 0.3 LAUDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 DINING/GREAT R Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FIsRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft' ft 0.3 HALL Default(8 lbs/sq.ft. ft' ft 0.3 FOYER Default(8 lbs/s.ft. ft 0.3 BEDROOM 3 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: Jurisdiction: w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. The insulation in any dropped ceiling/soffit /soffit Access openings, drop down stairs or knee wall doors to shall be aligned with the air barrier. unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including above -garage insulation. maintain permanent contact with the underside of and cantilevered subfloor decking, or floor framing cavity insulation floors) shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be out to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids 0 0....... ,oyc..wu .,, ,.,y wanes auau uc m acwmance wun the prov[510n5 or IUlY UU. 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft- 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 c. N/A R= ft- 4. Number of Bedrooms 3 d. N/A R= ft- 5. Is this a worst case? Yes 11. Ceiling Type and insulation level Insulation Area 6. Conditioned floor area (W) 1753 a. Under Attic (Vented) b. Knee Wall R=30.0 1753.00 ft- (Vented) R=19.0 30.00 ft' 7. Windows** Description Area c. N/A R= ft' a. U-Factor. Sgl, U=1.02 111.36 ft' 12. Ducts, location & insulation level R ft' SHGC: SHGC=0.29 a. Sup: Attic, Ret: Attic, AH: Attic 6 195 b. U-Factor: Sgl, U=1.11 40.00 ft' SHGC: SHGC=0.27 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft' a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ft2 SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2.850 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.285 S. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft' a. Electric Cap: 40 gallons SHGC(AVG): N/A EF: 0.97 9. Floor Types Insulation Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft' None b. WA R= ft' Credits (Performance method) None c. N/A R= ft' I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: C-+ Date: Address of New Home: \1 City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 Project Summary o Date: wrightsoft® Entire House BY QUICK CALCS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Prone: 7724 6-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM Proiect Information For. WYNNE DEVELOPMENT THE W INDSOR, FT. PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21542 Btuh Structure 16420 Btuh Duds 6191 Central vent (0 cfm) 0 Btuh Btuh Duds Central vent (0 cfirn) 9337 0 Btuh Btuh none (none) Humidificetion 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27734 Btuh Use manufacturers data n Rate/swingg multiplier 0.95 Infiltration Equipmenlsensible load 24470 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2495 Btuh Ducts 2546 Btuh Central vent (0 cfm) 0 Btuh Heatin Cool' ngg (none) Area (fl) 1759 1753 Equipment latent load 5041 Btuh Volume (11) 16478 16478 Air changesJhour 0.38 020 Equipment Total Load (Sen+Lat) 29511 Btuh Equiv.AVF(ctm) 104 55 Req.total capacity at0.70SHR 2.9 On Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Airflowfador Static pressure Space thermostat Capacity balance point = 36 OF 8.5 HSPF 34600 Btuh@47°F �cm 1160 0.042 cfm/Btuh 0 in H2O Baci Input=7kW, Output=23009Btuh,100AFUE Make Carrier Trade CARRIERAIRCONDITIONING Cond 25HBC536KO30 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Sensible cooling 24360 Btuh Latent000ling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 chin Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.84 Calculations approved byACCAto meet all requirements of Manual J 8th Ed wrightsolFC 2021-Jarv1213:18:18 --p- Rigf SUte®UAwm1201919.021 RSU08101 ...D..rtslWdgftDft WACkWYNNE-THEWINDSOR� Calc=M18 Fror Doorfams: N Page1 wrightsoft- Right- J® Worksheet Job: Entire House DPI QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-4666796 Email: OUICKCALCS@AOL.COM 1 Room name Entre House BEDROOM Elp s val 207.6 2 41.0 ft 3 Roomheight9.4 ft d 9A ft heaNmol 4 Room dimensions 14.0 x 20.0 It 5 Room area 1753A 12 280D IF Ty Construction U-value Or HTM Area (ft?) Load Area ( Load number I (BWhflF2F) (BWh4!"`) or pedme�r (ft) (Bfuh) or perimeter (ft) (Byh) Heat Cool Gros N/p/S Heat Cool Gros N/P/S Heat Cool 6 V 13A4ots 0.143 n 4.00 2.55 649 596 2386 1517 66 66 263 167 ��GC 1A-vom 1270 n 3556 34.77 15 0 533 522 0 0 0 0 4A5-2om 0.770 n 2156 1931 38 0 815 730 0 0 0 0 W 13A4o s 0.143 ne 4.00 255 27 27 106 68 0 0 0 0 11 13A-0as 0.143 a 4.00 2-55 141 100 400 255 0 0 0 0 1Aclom 1270 a 3556 87.06 20 1 711 1741 0 0 0 0 11D0 0.390 a 1092 11.31 21 21 229 238 0 0 0 0 W 13A-0ars 0.143 se 4.00 255 27 27 106 68 0 0 0 0 13A4ar 0.143 s 4.00 255 536 530 2121 1349 188 188 753 479 1Ac1cm 1270 s 3556 34.77 6 6 213 209 0 0 0 0 l4r 13A-40cs a143 w 4.00 2-95 320 255 1022 649 132 108 432 275 tAclom 1270 w 35.56 5453 12 1 415 636 12 1 415 636 III----GGG 1Actom 1270 w 3556 5453 12 1 427 654 12 1 427 654 4AS2om 0.770 w 2156 45.63 41 2 880 1862 0 0 0 0 P 12COw 0.091 255 128 254 254 647 326 0 0 0 0. C 16A30md 0.032 - 090 2.32 1753 1753 1571 4067 280 280 251 650 F 22A-Ipi 0.989 - 27.69 0.00 1753 208 5748 0 280 41 1135 0 6 c)AED exarnaon 397 488 Envelopeloss(gain 18331 15285 3676 3349 12 a) Infiltration 3211 905 729 205 b) Roomventilabon 0 0 0 0 13 Irdemalgains: Occupants@ 230 1 230 0 0 ApplianceJother 0 0 Sub471a1(lines6to13) 21542 16420 4405 3554 Lesemernalload 0 0 0 0 Les transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 21542 16420 4405 355 4 15 Duct loads 290A 57% 6191 9337 29% 57°/, 1266 2021 Total room load 27734 25757 5671 5575 Airrequired(cfm) 1160 1160 237 251 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. w,!Eh ?n` 2021Jan1213:18:18 �j RighSutE@Unversa1201919.021 RSU08101 "'--"...Do rtslWdgtivftWAQWYNNE-THEWINDSORnp Calc=Mt8 FrordDoorfaces:N Page wrightsoft° Righttil® Worksheet Job: Entire House per: QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Plxme: 7724666799 Fax 772-4666796 Email: OUICKCALCS@AOL,COM 1 Room name WIC MASTER BATH 2 E;1poSedwall 0 ft 9.0 ft 3 Room height 9.4 It heaV000l 9A ft heaVcool 4 Room dimensions 7.0 x 9.0 It 7.0 x 9.0 It 5 Room area 63.0 fF 63.0 fF Ty Constriction U-value Or HTM Area (fF) Load Area number (Bluhffe °F) (Ebhv) or perimeter (ft) (BWh) or perimeeter (ft) (B hh) Heat Cool Gros N/P/S Heat Cool Gross NIPS Heat Cool 6 W - im4ocs 0.143 n 4.00 255 0 0 0 0 0 0 0 0 1A-dw 1270 In 35.% 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 2156 1931 0 0 0 0 0 0 0 0 w 13A-4ors 0.143 ne 4A0 2S5 0 0 0 0 0 0 0 0 11 13A-0acs 0.143 a 4.00 2S5 0 0 0 0 0 0 0 0 1A-d m 1270 a 3556 87.06 0 0 0 0 0 0 0 0 III�---DODO 11DO 0.390 a 1092 11.31 0 0 0 0 0 - 0 0 0 W 13A4as 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 13A4as 0.143 s 4A0 255 0 - 0 0 0 85 85 339 215 1Ac1cm 1270 s 3556 3477 0 0 0 0 0 0 - 0 0 13A-4ors 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1am 1270 w 3556 54.53 0 0 0 0 0 0 0 0 1Aciom 1270 w 3556 54.53 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 P 12C-OvN 0.091 - 2.55 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 090 2.32 63 63 56 146 63 63 56 146 F 22A-tpl 0.%9 - 27.69 0.00 63 0 0 0 63 9 249 0 6 c)AED exa cn -10 -28 Ernelope loss/gain 56 136 644 334 12 a) Nitration 0 0 160 45 b) Roomeentlabon 0 0 0 0 0 13 Internal gains Ocwpants@ 230 0 0 0 0 Appliancesbther 0 0 Subtotal(lines6to13) 56 136 804 379 Leseldamal load 0 0 0 0 Lestransfer 0 0 0 0 Redistribufion 0 0 0 14 SubfoFal 56 6 136 &A 379 15 Ductloads 29% 57% 16 77 29 % 57% 231 216 Total loom load 73 214 1036 595 Air required(dm) 3 10 43 27 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed wVsspft m gh 2021-Jar-1213:18:18 RigktSute@L4iwrsa1201919.021 RSU08101 AA-.Downerts\Wngttwft HVAQWYNNE-TFiEWINDSORnp Cale=NUB Frort Doorfaces N Page 2 wrightsoft- Right-J@ Worksheet joh: Entire House Date: QUICK CALCS, INC. By. 317ST. LUCIE LN., Fr. PIERCE, FLW46 Prnre:772466-6799 F.772466-6796 Email:QUICKCALCS@AOL.COM 1 Room name MBATH KITCHEN 2 Epocedwaii 8.0 It 8.0 It 3 Room height 9.4 It heaVcool 9A R heaUcool 4 Room dimensions 7.0 x 8.0 ft 1.0 x 172A It 5 Room area 56.0 fe 172D IF Ty Construction U-value Or HTM Area Load Load number (BWh&-,F) (BWh� or pertm� (ft) (Bblh) or�perimeett+er (8) (BWh) Heat Cool Gross NIPS Heat Cool Gros NIPS Heat Cool 6 13AA= 0.143 n 4.00 255 0 0 0 0 0 0 0 0 1Ac1om 1270 n 3556 34.77 0 0 0 0 0 0 0 0 4A5-2om 0.770 n 2156 19.31 0 0 0 0 0 0 0 0 W 13AAors 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 V 13A-4ocs 0.143 a 4.00 2M 0 0 0 0 0 0 0 0 1Aolom 1270 a 3556 87.06 0 0 0 0 0 0 0 0 II-DG 11DO 0" a 1092 11.31 0 0 0 0 0 0 0 0 W 13AA= 0.143 se 4.00 255 0 0 0 0 0 0 0 0 W 13A4= 0.143 s 4A0 2.55 75 69 277 176 0 0 0 0 t-G tAclom 1270 s 35.56 34.77 6 6 213 209 0 0 0 0 13A-4= 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 w 3556 54.53 0 0 0 0 0 0 0 0 1Ac1om 1270 w 35.56 54.63 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 P 12C-OsN OD91 255 128 0 0 0 0 75 75 192 96 C 16A30md 0.032 - 090 2.32 56 56 50 130 172 172 154 399 F 22A-tpl 0989 - 27.69 OAO 56 8 222 0 172 8 222 0 6 c)AED exarsion .38 .3q EnwIope loss/gain 762 477 567 462 12 a) Infiltratm 142 40 0 0 b) Roomsedlation 0 0 0 0 13 internal gains: O=pante@ 230 0 0 0 0 Appliancesrother 0 0 Subtotal(lines6to 13) 904 517 567 462 Lesegemalload 0 0 0 0 Lestansfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 904 517 567 462 15 Dud loads 29% 57% 260 294 29% 57% 163 263 Total room load 1164 811 730 725 Airrequired(dm) 49 37 31 33 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed -r�F- wrlgbLsof'C^ 2021-Ja 1213:18:18 i9 A RqI Sute®Urrversa1201919.021 RSU08101 Page ...Dow rtslWdgftDft HVAQWYNNE-THEWINDSORnp Calc=92 Fror¢DoorfacesN wriotsoft° Right-J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phore: 772-466-6799 Farc 772A66-6796 Email: QUICKC4LCS@AOL.COM 1 2 Room name BATH BEDRC 3 F�wsed wall Room height 5.0 ft It 42.6 ft 4 om Rodimensions 9.4 ft heaNmol 9D x 5.0 ft 9.4 ft hea%o of 5 Room area 45.0 ff 1.0 x 204.0 It 204.0 tg Ty Construction U-value Or HTM Area Load number (BWhw-.g (BWW) or perimeter(d) (BWh) or perimeler (ft) (BNh) Heat Cool Gross N/P5 Heatn01200 Gross N/P/S Heat Cool 6 V[13A-0as 1A-ciom 0.143 n 4.00 2S5 47 47 18 132 132 527 3M II-(G' 1270 n 35-M 34.77 0 0 0 0 0 0 4A5-2om 0.770 n 21M 19.31 0 0 0 0 0 0 13AAors 0.143 ne 4.00 2.55 0 0 27 27 106 68 11 4y 13A-4ors 0.143 a 4A0 2.55 0 0 85 65 259 164 II--DG1Actam 1270 a 3556 87.06 0 0 20 1 711 1741 11DO 0.390 a 1022 11.31 0 0 0 0 0 0 W 13A4ors 0.143 se 4.00 2.55 0 0 27 27 106 68 13A4= 0.143 s 4.00 2.55 0 0 132 132 527 335 1Ac1om 1270 s 351% 34.77 0 0 0 0 0 0 13A-0ors w 0 0 0 0 1Ac1om 1270 1270 w 34.00 5.56 4.53 52.55 0 0 0 0 1Aclom 1270 w 35.56 54.63 0 0 0 0 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P 12C-Ow 0.091 2.55 128 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 45 45 40 104 204 204 183 473 F 22A-tpl 0.969 - 27.69 0.00 45 5 138 0 204 43 1179 0 6 c)AMe=rsion -17 -99 Envelope loss/gain 367 207 3599 3085 12 a) Infiltatlon 89 25 758 214 b) Roomventilation 0 0 0 0 13 Internal gains O=pan6@ 230 0 0 p 0 Applianceother 0 0 Subfotal(Iines6 to 13) 456 232 4357 3299 Lesexemal load 0 0 0 0 Lestransfer 0 0 Redistribution 0 0 0 0 14 Sub=] 456 232 435 3299 15 Durtloads 29% 57% 131 132 29% 57% 1252 1876 1876 Total room load 587 364 5609 5175 Airrequired(Cm) 25 i6 235 233 Calculations approved byACCAto meet all reouirementsof Manual J 8th Ed 2021-Jan1213:18:18 A�C RigfrSiite@Uri rM1201919.021RSU08101 Page4 ...Doa rts\Wdghboft HUAC\WYNNE-THEWINDSORnp Calc=IVU8 FroNDwrfaces:N wrightsoW Right-J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. 13y 317 ST. LLICIE UN., FT. PIERCE, FL 34946 Phom 772-466.6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name ENTRY LAUNDRY 2 Euposdwall 18.0 It 13.0 ft 3 Room height 9.4 It heatloDol 9.4 ft heaNmbl 4 Room dimensans 1.0 x 92A It 7.0 x 6.0 It 5 Room area 92.0 1F 42.0 fe Ty Construction U-value Or HTM Area Load Am (T) Load number (BWMf,T) A11111) or perimeter (ft) (BWh) or perimeter (ft) (BUh) Heat I Ccol G. NIPS Heat Cool Gros NIPS Heat Cool 6 V+/ 13A4= 0.143 n 4.00 2,55 0 0 0 0 0 0 0 - 0 1Aa1om 1270 n 3556 34.77 0 0 0 0 0 0 0 0 4A5.2om 0.770 n 2156 1931 0 0 0 0 0 0 0 0 W 13A-4= 0.143 re 4.00 2.55 0 0 0 0 0 0 0 0 11 y/ 1344ors 0.143 a 4A0 2.55 56 35 142 90 0 0 0 0 IAatan 1270 a 35.56 87.06 0 0 0 0 0 0 0 0 II--DG 11D0 0390 a 10.92 1131 21 21 229 238 0 0 0 0 W 13A-0as 0.143 se 4A0 255 0 0 0 0 0 0 0 0 lM T-8 13A-4bc5 0.143 s 4.00 255 0 0 0 0 56 56 226 144 1Ac1om 1270 a 3556 34.77 0 0 0 0 0 0 0 0 V�/ 13A-4= 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 �C 1Ac1om 1270 w 3556 54.53 0 0 0 0 0 0 0 0 1A-dom 1270 w 3656 5453 0 0 0 0 0 0 0 0 I�—CC 4A5-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P 12C-Orm 0.097 255 128 113 113 287 145 66 66 168 84 C 16A-30md 0.032 - OR 232 92 92 82 213 42 42 38 97 F 22A-tpl 0.989 - 27.69 0.00 92 18 498 0 42 13 360 0 6 c)AED ewursim -49 -24 Erwelope Ices/gain 1239 637 791 301 12 a) In6ltrafion 107 30 107 30 b) RoomeenGlabon 0 0 0 0 13 Internal gains Occupants@ 230 0 0 0 0 Applianoes(other 0 0 Subtolal(lines 6b 13) 1346 667 898 331 Les e)demal load 0 0 0 0 Lestrarsfer 0 0 0 0 Redisbiblticn 0 0 0 0 14 Subtotal 1346 667 898 331 15 DUQloads 29% 57% 387 379 29% 57% 258 188 Total mom load 1733 1047 1 1156 520 Air required(cfm) 72 47 48 23 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed wrl9tfLsor[- 2021-Jarn1213:18:18 ' 9911Sule@Lkiwe 1201919.021RSU08101 Page5 ...Ooa rts\WdgHsotHVAC\WYNNE-THEWINDSORAp Caic=M18 FrorCDoorfaces N t t wrightsoft- Right-J® Worksheet Job: Entire House Date. QUICK CALCS, INC. BY 317ST.LUCE LN,FL PIERCE, FL34946 Phore:772466-6799 Fa 772-466E796 EmaO:QUICKGLCS@AOL.COM 1 Room name GREAT)DINNG Room7 2 3 Dposedwall Room height 50D t 9.4 It heabbod 13D it 9.4 it heatbod 4 5 Room dimensions Room area 1.0 x 567.0 It 567D fl' 13,0 x 13.0 ft 169.0 IF Ty I Constrixtiort number U-Value Or HTM Area M) or perimeter (it) Load (BWh) Area (w) or perimeter (it) Load (BWh) Heat Cod Gross NrP1S Het Cod Gross NOS Heat Cool 6 i i Vt/ 13A-0as -1A-d= 4A5-2orn 13A-4ocs 1344= - 0.143 1270 0.770 0.143 0.143 - n n n ne a 4.00 35M 21M 4DO 4A0 2.55 34.77 1931 255 255- 282 0 38 0 0 244 0 0 0 0 978 0 816 0 0 622 0 730 0 0 122 15 0 0 0 107 0 0 0 0 429 533 0 0 0 - - 273. 522 0. 0 - 0 w 4y II--- 1Aclam 11DO 13A4= 1270 0390 0.143 a a se 35M 1092 4DO 87D6 - 1131 255 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0- 0 a - 0 —:0-- 0 _ 0 - 0 0 w t113AAm -1Ao1om 1&44= IA-clorn 1Adom 0.143 1270 0.143 1270 1270 s s w w w - 4D0 3556 4DO 3556 3556 2.55 34.77 2.55 54M 54S3 0 0 188 0 0 0 0- 147 0 0 0 0 589 0 0 0 0 375 0 0 0 0 0 0 0 0- 0 0 0 0 _ 0 0- 0 0 0 - o - 0 0 0 0 —G P - 4A&2orn 12C-Ow 0.770 0.091 w - 2156 255 45.63 128 41 0 2 0 880 0 1862 - 0 0 - 0 0 0 0 0- 0 - o. C F 16430md 22Agpl 0.032 0.989 - - 090 27.69 232 OM 557 567 567 50 508 1385 1315 0 169 169 169 13 151 360 392 - 0- 6 o4AEDe=rson 307 -100 Envelope loss/9ain 5154 5210 1474 1086 12 a) Mitation b) RoomcentiMon 889 0 251 0 1 231 0 65 0 13 Internal gain Oovpan5@ 230 0 0 1 230 Applianoes(other 0 0 SubmW(lirm6fi13) 6043 5461 1705 1381 LesseAuMload 0 0 0 0 I-mirarnier 0 0 0 0 14 Redi:9Wbuficn Subtotal 0 6043 0 6461 0 1705 0 1381 15 Durtloads 29% 57% 1737 3105 29% 57% 490 785 Total man bad Airrequred(dm) 7780 325 8566 386 2195 92 2167 98 Calculations approved bvACCAto meet all reauirements of Manual J 8th Ed wrIgtat cpm- 2021-Ja 1213:18:18 -1-- MgHSUL-O Uriversal 201919.021 RSU08101 P e 6 ...Doo rts\Wngttroft WAQWYNNE-T EWINDSORnp Caic=MB r-roMDoorfaom N -1 wrightsoft® Duct System Summary o: Entire House eY QUICK CALCS, INC. 317 ST. LUCIE LN, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Er ii: OUICKCALCS@AOL.COM Project• • For. WYNNE DEVELOPMENT THE W INDSOR, FT PIERCE, FL Heating Cooling External static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply/return available pressure 0.000/0.000 in H2O 0.000/0.000 in H2O Lowest friction rate 0 in/100ft 0 in/100ft Actual airflow 1160 cfrn 1160 clin Total effective length (TEL) 0 ft Supply Branch Detail Table Name Design (Btuh) Htg (c5n) Clg (ctm) Design FR Diam (in) H x W (in) Dud Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 364 25 16 0 0 Ox 0 ShMt 0 0 BEDROOM C 2788 119 126 0 0 0x0 ShMt 0 0 SEDROOM2 h 2587 117 117 0 0 OxO ShMt 0 0 BEDROOM2-A h 2587 117 117 0 0 OXO ShMt 0 0 BEDROOM -A c 2788 119 126 0 0 Ox0 ShMt 0 0 ENTRY h 1047 72 47 0 0 Ox 0 ShMt 0 0 GREATIDINING C 2855 108 129 0 0 OX 0 ShMt 0 0 GREAT/DINING-A c 2855 108 129 0 0 OXO ShMt 0 0 GREAVDINING-B C 2855 108 129 0 0 Ox0 ShMt 0 0 KITCHEN C 725 31 33 0 0 Ox 0 ShMt 0 0 LAUNDRY h 520 48 23 0 0 Ox0 ShMt 0 0 M. BATH h 811 49 37 0 0 Ox 0 ShMt 0 0 MASTER BATH h 595 43 27 0 0 0x0 ShMt 0 0 ROOm7 C 2167 92 98 0 0 0x0 ShMt 0 0 WIC c 214 3 10 0 0 Ox0 ShMt 0 0 Return Branch Detail Table Name Grille Size (in) Htg (Cfm) Cig (dm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Dud Mat Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 ShMt -fId- wrightsoR' 2021-Jan1213:18:19 •++. � ..�..u..e, RigttSuleOUnv 1201919.021 RSU08101 Page t �+� ...D.o ris\WngtfsoftWAC1WYNNE-THEWINDSOR.np Caic=MlB Frord Doorfaces: N