Loading...
HomeMy WebLinkAboutConstruction Inspection & FinalSTATE OF FLORIDA 1 DEPARTMENT OF HEALTH s 'L' ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM ,y CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Adams Homes of Northwest Fla, Inc. AGENT: Benjamin Drew"s Plumbing & Drain Services PROPERTY ADDRESS: 5513 Myrtle Dr Fort Pierce, FL 34982 APPLICATION #:AP1508209 PERMIT #:56-SF-2088697 DOCUMENT # : F [ 1766944 DATE PAID:06/04/2020 FEE PAID:545.00 RECEIPT #:56-PID-4440843 LOT: 34 BLOCK: 54 SUBDIVISION: Indian River Estates ID#: 3402-609-0092-000-3 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [11 1050.00 [21 300.00 [ ] [27] SURFACE WATER FT [ ] [021 TANK MATERIAL Polypropylene [ ] [281 DITCHES 11 FT [ ] [031 OUTLET DEVICE [ ] [291 PRIVATE WELLS FT [ ] [041 MULTI -CHAMBERED [ Y N ] [ ] [30] PUBLIC WELLS FT [ ] (051 OUTLET FILTER Polylok PL-68 [ ] [31] IRRIGATION WELLS FT [ ] [061 LEGEND 1. 70-156-10DC3 2. 70-156-03SC3 [ ] [32] POTABLE WATER 31 FT [ ] [071 WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 7 FT [ ] [08] LEVEL [ ] [341 PROPERTY LINES 11 FT [ ] [091 DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 675 [21 SQFT [ ] [361 DRAINFIELD COVER [ ] (111 DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] (121 NUMBER OF DRAINLINES 1. 6.00 2. ( ] [38] SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [39] STABILIZATION [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 6.00 [ ] [401 UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [181 DOSING PUMPS 1.00 [ ] [421 ALARMS [ ] (19] AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] (441 BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN [ ] [46] FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [221 FILL AMOUNT [ ] [47] CONTRACTOR (Reliable Septic & Services) [ ] (231 FILL TEXTURE [ ] [481 OTHER INFILTRATOR ARC 24 [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [491 TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. / S cle CHD DATE: 08/19/2021 CONSTRUCTION [ APPROVED DI SAPPROV vironme a S ecialist 1 NMMontaneorida . Depa ent of He FINAL SYSTEM [ APPROVED / DISAPPROVED ]- St.LUCIe CHD DATE: 01/11/2022 Environmental Specialist I tthe ajany) ( ida Depa ent of H (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 A P1508209 EID2088697 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP h508209 PERMIT #:56-SF-2088697 DOCUMENT # : F 11766944 DATE PAID : 06/04/2020 FEE PAID:545.00 RECEIPT #:56-PID-4440843 The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400 gpd. New ST, DT, Liberty 1/3 hp pump, and 4x7+1x8+1x9 long BED DF installed. No violations, system ok to cover. Contractor notified onsite. Needs final inspection for mound system, alarm and final site grading. Final inspection completed. Mound system checked, alarm checked, and final site grading completed. Final inspection approved. Emailed copy to building department and contractor. DH 4016, 06/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1500209 EID2088697