Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeRE�/IEINED _FOR__ CODE COMPLIANCE FORM R405-2020 ST. LUCIE COUNTY BOCC FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Fli rids Department of Business and Professional Regulation - Residential Performance Method Project Name: Model H4 -51 Paleo 11-24-2021 Builder Name: HQ Cor�Y��yt' Street: 5206 Paleo Circle Permit Office: /"�� City,JState, Zip: Fort Pierce, FL, 34951 Permit Number: Y Owner: HQ Construction Jurisdiction: Design Location: FL, ST LUCIE_CO_INTL i County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 10. Wall Types(1424.0 sgft.) Insulation Area 2, Single family or multiple family Detached a. Concrete Block - Int Insul, ExteriorR=4.1 1176.00 ftz 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 248.00 ft2 c. N/A R= ftz 4. NIumber of Bedrooms 4 d. N/A R= ftZ 5. Is this a worst case? No 11. Ceiling Types(1985.0 sqft.) Insulation Area I a. Under Attic (Vented) R=30.0 1985.00 ft2 6. Conditioned floor area above grade (ftz) 1985 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 I c. N/A R= ft2 7. indows(155.1 sgft.) Description Area 12. Ducts, location & insulation level R ftz a. -Factor: Dbl, U=0.35 155.08 ft2 a. a. Sup: Attic, Ret: Main, AH: Garage 6 150 SHGC: SHGC=025 b. b. b-Factor: N/A ft2 C. SHGC: 13. Cooling Systems kBtu/hr Efficiency C. iJ-Factor: N/A ft2 a. Central Unit 36.0 SEER:17.00 SHGC: Area Weighted Average Overhang Depth: 0.000 ft Area Weighted Average SHGC: 0.250 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Strip Heat 10.0 COP:1.00 U 9Factor:(AVG) N/A N/A ft2 SHGC(AVG): N/A 15. Hot Water Systems 9. F oor Types Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R= 0.0 1985.00 ft2 EF: 0.960 b. N/A R= ft2 b. Conservation features c. R= ft None �/A 16. Credits Pstat Glas's/Floor Area: 0.078 Total Proposed Modified Loads: 54.73 PASS Total Baseline Loads: 55.53 I hereby certify that th _pan nd specifications covered by calculation Review of the plans and TEIE ST this are in mplian with the Florida Energy specifications covered by this tioj Code. calculation indicates compliance with the Florida Energy Code. y ''k r rrrrrr, - --.p F.- PREPARED BY Before construction is completed ._ p this building will be inspected for DATE: t<<rZ�L� 2 compliance with Section 553.908 Florida Statutes. I hereby certify that this buildi g, as designed, is in compliance CODv with ithe Florida En Co e OWNER/AGE(`1T: BUILDING OFFICIAL: DATE: f 2JUza_ DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 6.70 ACH50 (R402.4.1.2). 11/24/2021 12:28:52 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 I INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Model H4 -51 Paleo 11-24-2021 Address type: Street Address Building Type: User Bedrooms: 4 Lot #: Owned: HQ Construction Conditioned Area: 1985 Block/SubDivision: — Total Stories: 1 PlatBook: Builder Name: HQ Construction Worst Case: No Street: 5206 Paleo Circle Permit Office: Rotate Angle: 0 County: St. Lucie Jurisdiction: Cross Ventilation: City, State, Zip: Fort Pierce, Family' Type: Detached Whole House Fan: FL, 34951 New/Existing: New (From Plans) Terrain: Suburban Year Construct: 2021 Shielding: Suburban Comment: I CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmv Site 97.5% 2.5% Winter Summer Degree Days Moisture Range II FL, ) T LUCIE_CO_INTL FL VERO_BEACH_MUNICIPA 39 90 70 75 299 58 Medium 1 BLOCKS Number Name 1 Area Volume 1 I Blockl 1985 15880 SPACES Number Name i Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated —1 Main 1985 15880 Yes 7 4 Yes Yes Yes FLOORS (Total Exposed Area = 1985 sq.ft.) # I' 1 Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _ 1 I Slab -On -Grade Edge Ins Main 147 0 1985 ft 0.304 — 0.00 0.00 1.00 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch ✓# Type Materials Area Area Color Barr Absor. Tested Tested Insul_ (deg) _ 1 Hip Composition shingles 2150 ft2 0 ft2 Medium N 0.96 No 0.9 No 0 22.62 1 ATTIC # j Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 I Full attic Vented 300 1985 ft2 N N 1 CEILING (Total Exposed Area = 1985 sq.ft.) # j Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type 1 Under Attic(Vented) Main 30.0 Batt 1985.Oft2 0.053 0.11 Wood I 11/24/2021 12:28:52 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 I INPUT SUMMARY CHECKLIST REPORT I WALLS (Total Exposed Area = 1424 sq.ft.) VAdjacent Cavity Width Height Area U- Sheath Frm. Solar Below # Or?t To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade I -1 E Exterior Conc- Blk - Int Ins Main 4.1 28.0 0 &0 0 224.0 0.149 0 0.75 0 % _ 2 S Exterior Conc. Blk -Ent Ins Main 4.1 40.0 0 8.0 0 320.0 0.149 0 0.75 0 % 3 W Exterior Conc. Blk - Int Ins Main 4.1 49.0 0 8.0 0 392.0 0.149 0 0.75 0 % _4 N Exterior Conc. Blk - Int Ins Main 4.1 30.0 0 8.0 0 240.0 0.149 0 0.75 0 % _ 5 E Garage Frame - Wood Main 13.0 21.0 0 8.0 0 168.0 0.084 0.23 0.75 0 % _ 6 ' Garage Frame - Wood Main 13.0 10.0 0 8.0 0 80.0 0.084 0.23 0.75 0 % f DOORS (Total Exposed Area = 21 sq.ft.) V# Or+t Adjacent To Door Type Width Height Space Storms U-Value Ft In Ft In Area _ 1 E I Exterior Insulated Main None 0.46 3.00 0 7.00 0 21.0ft' WINDOWS (Total Exposed Area = 155 sq.ft.) Wall --Overhang--- V# Orit ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening 1 E 1 Vinyl Double (Clear) Yes 0.35 0.25 N N 30.0ft' 0.0 ft 0 in 0.0 ft 0 in Drapesiblinds None 2 E 1 Vinyl Double (Clear) Yes 0.35 0.25 N N 7.3ft' 0.0 ft 0 in 0.0 ft 0 in Drapes/blinds None -3 W 3 Vinyl Double (Clear) Yes 0.35 0.25 N N 7.3ft' 0.0 ft 0 in 0.0 ft 0 in Drapes/blinds None 4 W 3 Metal Double (Clear) Yes 0.35 0.25 N N 96.0' 0.0 ft 0 in 0.0 ft 0 in Drapes/blinds None 5 N 4 Vinyl Double (Clear) Yes 0.35 0.25 N N 14.6ft' 0.0 ft 0 in 0.0 ft 0 in Drapes/blinds None INFILTRATION # ScQpe Method SLA CFM50 ELA EgtA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00034 1773 97.29 182.64 0.1209 6.7 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation _1 420ft' 420ft' 51 ft 8ft 1 MASS I # Mass Type Area Thickness Furniture Fraction Space 1 1 'efault(8 Ibs/sq_ft.) 0 ftz 0 ft 0.30 Main HEATING SYSTEM l # System Type Subtype AHRI # Efficiency Capacity -Geothermal HeatPump---- Ducts Block Ii kBtu/hr Entry Power Volt Current I -1 Electric Strip Heat None COP: 1.00 10.0 0.00 0.00 0.00 sys#1 1 11 /24021 12:28:52 PM I EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 i FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity Air Flow SHR Duct Block I kBtu/hr cfm _ 1 Central Unit Split/Single SEER:17.0 36.0 1080 0.75 sys#1 1 HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length t 1 Electric None Garage 0.96 (0.93) 40.00 gal 70 gal 120 deg Standard =>R-3 99 Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits Recirculation System Type length length power Connected Flow Eff I 1 p No NA NA NA No NA NA NA None DUCTS --------Supply-------- ----Return - Air CFM 25 CFM 25 HVAC # VDuct # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic t 6.0 150 ft2 Main 6.0 5 ft2 Prop. Leak Free Garage -- — 0.03 0.50 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: N Cooling [] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct I] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun []Jul [ ] Aug I] Sep [ ] Oct [X] Nov [X] Dec Venting i [ ] Jan [ ] Feb [X] Mar [X] Apr [ ] May [ ] Jun []Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec 1 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type II 1 2 3 4 5 6 7 8 9 10 11 12 _ Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 i _ Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 _ Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1 12:28:52 PM EnergyGauge ) USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4