HomeMy WebLinkAboutREVISION For Application Building PermitOFFICE USE ONLY: DATE FILED: REVISION FEE: 'v 7 PERMIT # 2101-0347 RECEIF-T , PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE LOCATION/SITE 4F UN ADDRESS: 38 SOVEREIGN WAY, FORT PIERCE, FL 34949 DETAILED DESCRIPTION OF PROJECT REVISIONS: ENGINEER SIGN OFF OF STRUCTURE SLAB CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CBC 1263072 BUSINESS NAME: PORT ST LUCIE PROPERTIES, INC QUALIFIERS NAME: MARK MONTALTO ADDRESS: 201 SW PSL BLVD SUITE 103 CITY: PORT ST LUCIE STATE: FL PHONE (DAYTIME): 772-336-0050 OWNER/BUILDER INFORMATION: NAME: MARK MONTALTO ADDRESS: 201 SW PSL BLVD SUITE 103 CITY: PORT ST LUCIE PHONE (DAYTIME: 772-336-0050 STATE: FL ARCHITECT/ENGINEER INFORMATION: NAME: PAUL WELCH JR ADDRESS: 1984 SW BITMORE ST CITY: PORT ST LUCIE PHONE (DAYTIME): 772-785-9888 SLCCC.• 9123109 Revised 06130/17 STATE: FL ST. LUCIE CO CERT. #: 31220 FAX: FAX: PAX: ZIP: 34984 ZIP: 34984 ZIP: 34984 STRUCTURAL NOTES, SPECIFICATIONS AND GENERAL REQUIREMENTS DESIGN CRITERIA D-1 CODES: - FLORIDA BUILDING CODE 7TH EDITION (2020) - ASCE 7-16 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES" D-2 DESIGN DEAD LOADS: ROOF 20 PSF 8" MASONRY WALL 55 PSF CONCRETE 150 PCF DESIGN LIVE LOADS: ROOF 20 PSF RESIDENTIAL AREAS 40 PSF D-3 SEISMIC: ZONEO D-4 PREPARE SITE IN ACCORDANCE WITH THE GEOTECHNICAL REPORT, PREPARED BY KSM ENGINEERING AND TESTING, JOB NO. 213143-b, DATED MAY 612021 GENERALNOTES G-1 REVIEW ALL PROJECT DOCUMENTS PRIOR TO FABRICATION AND START OF CONSTRUCTION, REPORT ANY DISCREPANCIES TO ARCHITECT OR STRUCTURAL ENGINEER PRIOR TO PROCEEDING WITH WORK. G-2 THE CONCRETE WALLS ARE NOT DESIGNED TO WITHSTAND TEMPORARY CONSTRUCTION LOADS. IT IS THE CONTRACTOR'S RESPONSIBILITY AT ALL TIMES TO MAINTAIN WALL STABILITY DURING THE CONSTRUCTION PHASE OF THIS PROJECT. G-3 IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROTECT EXISTING FACILITIES, STRUCTURES AND UTILITY LINES FROM ALL DAMAGE DURING CONSTRUCTION, G-4 NO STRUCTURAL MEMBER SHALL BE CUT, NOTCHED OR OTHERWISE REDUCED IN SIZE OR STRENGTH WITHOUT PRIOR APPROVAL IN WRITING FROM THE STRUCTURAL ENGINEER G-5 COORDINATE STRUCTURAL AND OTHER DRAWINGS THAT ARE PART OF THE CONTRACT DOCUMENTS FOR ANCHORED, EMBEDDED OR SUPPORTED ITEMS WHICH MAY AFFECT THE STRUCTURAL DRAWINGS (LE. MECHANICAL, ELECTRICAL, PLUMBING, DUCTWORK, ETC.) G-6 ALL DETAILS AND SECTIONS ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT EXCEPT WHERE A SEPARATE DETAIL IS SHOWN, G-7 THE INTENTION OF THE PLANS AND SPECIFICATIONS IS TO PROVIDE ALL NECESSARY DETAILS TO CONSTRUCT A COMPLETE STRUCTURE, WHEN SPECIFIC INFORMATION IS MISSING OR IS IN CONFLICT, THE CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER. G-8 THE ENGINEER SHALL NOT BE RESPONSIBLE FOR LAYOUT, DIMENSIONAL ERRORS OR DISCREPANCIES RESULTING FROM THE REPRODUCTION AND USE OF CONTRACT DRAWINGS FOR ERECTION AND SHOP DRAWINGS. USE OF CONTRACT DRAWINGS REPRODUCED IN WHOLE OR ANY PART IN SHOP DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR NOR SUBCONTRACTORS FROM THEIR RESPONSIBILITY TO ACCURATELY LAYOUT, COORDINATE, DETAIL, FABRICATE AND INSTALL A COMPLETE STRUCTURE, G-9 REVIEW ALL SHOP DRAWINGS FOR CONFORMANCE WITH THE CONTRACT DOCUMENTS AND FOR COMPLETENESS AND ANSWER ALL CONTRACTOR RELATED QUESTIONS, STAMP AND INITIAL ALL SHEETS PRIOR TO SUBMITTING SHOP DRAWINGS TO ARCHITECT/ENGINEER FOR REVIEW, NON-COMPLIANCE WITH THIS REQUIREMENT WILL RESULT IN REJECTION OF SUBMITTAL, G-10 ALL BOLTS, SCREWS, NUTS, WASHERS, NAILS & ETC, TO BE OF STAINLESS STEEL DEEP FOUNDATIONS -AUGER CAST PILE DF-1 AUGERCAST PILING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE GEOTECHNICAL RECOMMENDATIONS AND INSTALLATION PROCEDURES CONTAINED IN THE GEOTECHNICAL REPORT, LISTED IN DA DF-2 ALL PILES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE SOILS ENGINEER AND PROVIDE THE FOLLOWING SIZE AND CAPACITIES: PER REPORT PREPARED BY KSM ENGINEERING AND TESTING, JOB NO. 213143-b, DATED MAY 6, 2021, 14" DIA. AUGER CAST PILES 56 KIPS COMPRESSION (29 FT. LENGTH) DF-3 PILES SHOULD BE REINFORCED AS INDICATED IN "TYPICAL AUGERCAST PILING DETAIL", DF-4 GROUT SHALL BE PER AN APPROVED MIX DESIGN PROPORTIONED TO ACHIEVE A STRENGTH AT 28 DAYS OF 4000 PSI MINIMUM GROUT SHALL HAVE A MAXIMUM FLOW RATE OF 15 SECONDS, SUBMIT PROPOSED MIX DESIGN WITH RECENT FIELD CURED OR LAB CURED CYLINDER TESTS FOR REVIEW PRIOR TO USE, DF-5 GROUT SHALL BE TESTED IN ACCORDANCE WITH ASTM STANDARDS UTILIZING 3"x6" CYLINDERS, TEST CYLINDERS SHALL BE MADE AND CURED IN ACCORDANCE WITH ASTM C31 DF-6 WHEN PILES ARE IN CLUSTERS OF TWO OR MORE, INDIVIDUAL PILES SHALL BE INSTALLED WITHIN 3" OF THE DESIGN LOCATION. THE CUMULATIVE LOCATION OF THE PILE GROUP CENTER OF GRAVITY SHALL NOT EXCEED 11 SINGLE PILES SHALL BE INSTALLED WITHIN 1V OF DESIGN LOCATION, VARIATION FROM PLUMB SHALL NOT EXCEEDV IN TWO FEET, DF-7 ADJACENT PILES SHALL NOT BE PLACED UNTIL THE MORTAR HAS REACHED ITS INITIAL SET IN ORDER THAT THERE WILL BE NO INTER CONNECTION BETWEEN ADJACENT PILES WHILE THE MORTAR IS IN THE FLUID STATE, DF-8 AN AS -BUILT SURVEY OF PILE LOCATIONS SHALL BE PERFORMED BY A FLORIDA REGISTERED LAND SURVEYOR. PILES SHALL BE LOCATED ON THE AS -BUILT DRAWINGS HORIZONTALLY AND VERTICALLY FROM THE COLUMN CENTERLINES, SUBMIT AS -BUILT DRAWINGS TO THE STRUCTURAL ENGINEER FOR APPROVAL, DF-9 CONTRACTOR IS RESPONSIBLE FOR ENGINEERING COSTS ASSOCIATED WITH REDESIGNS CAUSED BY IMPROPER PILE LOCATIONS. DF-10 WHERE THE PILE CUTOFF IS NEAR THE SURFACE OR ABOVE THE BOTTOM OF THE EXCAVATION METAL SLEEVES OR CASING OF THE PROPER DIAMETER AND AT LEAST 18 INCHES IN LENGTH SHALL BE PLACED AROUND THE PILE TOPS (SPECIAL CONDITIONS MAY REQUIRE METAL SLEEVES OF ADDITIONAL LENGTH) DF-11 INSTALLATION OF PILING SHALL BE MONITORED BY A LICENSED GEOTECHNICAL ENGINEER, REPORTS OF WORK SHALL BE SUBMITTED FOR FEVIEW, REPORT SHALL INCLUDE PILE DEPTH, PILE GROUT VOLUME, GROUT FACTOR, CONCRETE COVERAGE ON THE REINFORCING STEEL, GROUT DELIVERY DATES, MISCELLANEOUS OBSERVATIONS, AND OTHER INFORMATION AS REQUIRED. REINFORCED CONCRETE RC-1 ALL CONCRETE DESIGN AND PLACEMENT SHALL BE IN STRICT ACCORDANCE WITH THE ACI "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE," ACI 318-14, RC-2 PROVIDE (4) TEST CYLINDERS FOR EACH 50 C.Y. OF CONCRETE PLACED OR FRACTION THEREOF, RC-3 STRUCTURAL CONCRETE SHALL CONFORM TO ACI 301 SPECIFICATIONS AND SHALL DEVELOP THE FOLLOWING MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS: GRADE BEAMS AND PILING 4000 PSI COLUMNS AND WALLS 5000 PSI BEAMS AND SLABS 5000 PSI ALL OTHER CONCRETE 3000 PSI RC-4 USE REGULAR WEIGHT CONCRETE. RC-5 STRUCTURAL CONCRETE SHALL CONFORM TO ACI 301 AND HAVE THE FOLLOWING SLUMPS, WATER CEMENT RATIO & AGGREGATE REQUIREMENTS: LOCATION SLUMP WIC RATIO MAX. AGGREGATE GRADE BEAMS 4"+/-1" 0.48 ASTM #57 SLABS ON GRADE 4"+/-1" 0.48 ASTM #57 COLUMNS & WALLS Y+/-1" 0,48 ASTM #57 BEAMS AND SLABS Y+/-1" 0,45 ASTM #57 TIE BMS & TIE COLS Y+/-1" 0.45 ASTM #8 PEAROCK SUBMIT DESIGN MIXES FOR APPROVAL AT LEAST ONE WEEK PRIOR TO CONCRETE POUR, DESIGN MIX SUBMITTALS MUST INDICATE PROPOSED LOCATION OR TYPE OF USE, FAILURE TO DO SO WILL CAUSE DELAY AND/OR REJECTION OF SUBMITTALS. RC-6 MAXIMUM WATER TO CEMENT RATIO WHEN NO BACK-UP DATA IS AVAILABLE: a) 3000 PSI, 28 DAY COMPRESSIVE STRENGTH; W/C RATIO 0.53 MAXIMUM (NON -AIR ENTRAINED), 0.47 MAXIMUM (AIR ENTRAINED) RC-7 FLYASH, WHEN USED, SHALL BE LIMITEDTO 20% OF THE CEMENTITIOUS MATERIAL. DO NOT USE FOR EXPOSED SLABS RC-8 SUBMIT COPIES OF CONCRETE MIX DESIGN TO ENGINEER FOR APPROVAL INFORMATION SHALL INCLUDE CEMENT CONTENT, WATER/CEMENT RATIO, SLUMP, ENTRAINED AIR, ADMIXTURE CONTENT AND QUANTITY. RC-9 ALL REINFORCEMENT SHALL BE FASTENED AND SECURED TOGETHER TO PREVENT DISPLACEMENT BY CONSTRUCTION LOADS OR THE PLACING OF CONCRETE RC-10 THE USE OF JITTERBUGS TO CONSOLIDATE CONCRETE WILL NOT BE PERMITTED. RC-11 ALL PUMPED CONCRETE WITH #57 AGGREGATE IS TO CONTAIN A HIGH RANGE WATER REDUCING AGENT MINIMUM SIZE OF DISCHARGE TO BE 4" I.D. RC-12 A 2" I.D. DISCHARGE MAYBE USED WITH #8 AGGREGATE. USE PLASTICIZER ADMIXTURE IF NECESSARY TO INCREASE SLUMPS BEYOND THAT NOTED ABOVE, RC-14 ALL REINFORCING STEEL SHALL BE DETAILED, FABRICATED AND INSTALLED IN ACCORDANCE WITH ACI 318 AND ACI DETAILING MANUAL, ACI-315 LATEST EDITION, RC-15 REINFORCEMENT WITH RUST, MILL SCALE OR A COMBINATION OF BOTH SHALL BE CONSIDERED SATISFACTORY, PROVIDED THE MINIMUM DIMENSIONS (INCLUDING HEIGHT OF DEFORMATIONS) AND WEIGHT OF A HAND -WIRE -BRUSHED TEST SPECIMEN ARE NOT LESS THAN APPLICABLE SPECIFICATION REQUIREMENTS IN THE ASTM STANDARDS REFERENCE IN ACI 318. REINFORCING BARS SHALL CONFORM TO ASTM A-6151GRADE 60, LATEST REVISION, WITH SUPPLEMENT (S1), MARKED "S". RC-16 ALL SLABS ON GRADE SHALL REINFORCED WITH: 4" SLAB ON GRADE: TX61- 1 4x1.4 WELDED WIRE REINFORCEMENT (WWR) LOCATED IN THEM IDDLE TO UPPER PORTION OF THE SLAB W.W.R. SHALL BE SUPPORTED WITH APPROVED MATERIALS OR SUPPORTS NOT EXCEEDING 3 FT OR IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. RC-17 WELDED WIRE FABRIC TO COMPLY WITH ASTM A1064 SHEETS ONLY, NO ROLLS, INSTALL ON BRICKS OR BOLSTERS, AT MID -DEPTH OF THE SLAB. RC-18 LAP CONTINUOUS REINF. AS NOTED IN LAP SPLICE SCHEDULE OR MIN 40 BAR DIA. LAP CONT. BOTTOM STEEL OVER SUPPORT AND CONT, TOP STEEL AT MIDSPAN UNLESS OTHERWISE SPECIFIED, RC-19 TERMINATE ALL DISCONTINUOUS TOP BARS WITH STANDARD 90 DEGREE HOOK (PLACED VERTICALLY) UNLESS NOTED OTHERWISE RC-20 PROVIDE CONCRETE COVER OVER REINFORCEMENT AS FOLLOWS, UNLESS OTHERWISE NOTED: MINIMUM COVER: LOCATION AND CONDITION: A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSEDTO EARTH ALL BARS 3" B. CONCRETE EXPOSED TO EARTH OR WEATHER #6 OR GREATER 2" #5 OR SMALLER 1-1/2" C CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND 1, SLABS, WALLS, AND JOISTS #11 OR SMALLER 3/4" #14-#18 1-112" 2. BEAMS AND COLUMNS: (PRIMARY REINFORCEMENT, TIES, STIRRUPS, AND SPIRALS) ALL BARS 1-1/2" D. SLABS ON GRADE: SINGLE MAT, TOP 1/2 TO 1/3 OF THICKNESS RC-21 SLEEVE ALL PENETRATIONS THROUGH BEAMS AND SLABS INDIVIDUALLY CORE DRILLING WILL NOT BE PERMITTED, SUBMIT LOCATION AND SIZE OF SLEEVES THROUGH BEAMS TO ENGINEER FOR REVIEW PRIOR TO CASTING CONCRETE, WHERE PIPING PENETRATES CONCRETE BEAMS, PLACE TWO #3 STIRRUPS @ Y O.C. EACH SIDE OF PIPE, UNLESS OTHERWISE NOTED, RC-22 NO REINFORCING BARS SHALL BE CUT TO ACCOMMODATE THE INSTALLATION OF ANCHORS, EMBEDS OR OTHER ITEMS. RC-23 USE THE STRUCTURAL DRAWINGS INCLUDING REVISIONS AND ADDENDA IN CONJUNCTION WITH REVIEWED SHOP DRAWINGS FOR PLACEMENT OF REINFORCING, RC-24 AT CHANGES IN DIRECTION OF CONCRETE WALLS, BEAMS & STRIP FOOTINGS, PROVIDE CORNER BARS OF SAME SIZE AND QUANTITY UNLESS NOTED OTHERWISE AS RC-25 ALL EMBEDDED ITEMS SHALL BE SECURELY TIED IN PLACE PRIOR TO CONCRETE PLACEMENT. RC-26 THE GENERAL CONTRACTOR IS RESPONSIBLE FOR FOR PROVIDING THE CONSTRUCTION OF ALL FORMWORK IN ACCORDANCE WITH ACI 347, RC-27 PLACE CONCRETE PER ACI 304 USE INTERNAL MECHANICAL VIBRATION FOR ALL CONCRrETE. LIMIT MAXIMUM FREE FALL DROP OF CONCRETE TO 6-0" FOR 457 AGGREGATE AND 8'-0" FOR #8 AGGREGATE ALL PRECAUTIONS SHOULD BE TAKEN TO AVOID SEGREGATION OF CONCRETE DURING PLACEMENT. RC-28 FOOTING SIZES SHOWN ARE FOR FOOTINGS CONSTRUCTED WITH SIDE FORMS. IF SOIL MATERIAL CAN HOLD A VERTICAL SHAPE, IT CAN BE USED AS AN EARTH FORM PROVIDED FOOTING WIDTH IS INCREASED 1" IN EACH HORIZONTAL DIRECTION ALL SLOUGHED MATERIAL SHALL BE REMOVED FROM EXCAVATION BEFORE AND DURING PLACEMENT OF CONCRETE, RC-29 PLACEMENT OF CONDUIT AND PIPES IN CONCRETE SHALL CONFORM TO ACI 318, SECTION 20.7 GRADE BEAM SCHEDULE MARK BEAM SIZE REINFORCEMENT STIRRUPS REMARKS TOP OF BEAM nC" OR "E" 110" OR "En BOT BARS uDri BARS SIZE TYPE SPACING W T DEPTH ELEVATION TOP BARS BARS LEFT BARS RIGHT GB1 24" 24" VARIES 3-96 3-#6 43 Q 12" O.C. G132 24" 24" VARIES 3-96 3-#6 93 8" O.C. G23 24" 24" VARIES 3-46 346 93 Q 8" O.C. GB4 24" 24" VARIES 346 3-1*6 93 Q 16" O.C. NOTES: 1, STIRRUPS CAN BE DISCONTINUED WITHIN MIDDLE 1/3 OF SPAN 2, BEAM DEPTH IS ADJUSTABLE, SET BOTTOM OF BEAM AT A MINIMUM OF 6" BELOW GRADE. 24" MINIMUM BEAM DEPTH * CONTRACTOR TO VERIFY ALL BEAM SIZES PRIOR TO C0111cTF'_-'' '.'REPORT ANY DtSCREPu°d�'lES TO ENGINEER rn 0.25 LN-1 GREATER OF 0,33 LN-1 rn z CONTINUOUS OR 0.33 LN-2 OR "B" BARS CONTINUOUS OVER Q � V IF SHOWN > CONTINUOUS IF SHOWN GRADE BEAMS UNLESS SPLICE rn U REQ'D � T' BARS T" BARS S' BARS 2" CLR W/ VAPOR BARRIER 3" CLR WAD VAPOR BARRIER LN-1 BAR DESIGNATION: / 4T16 WHERE 4 INDICATES SIZE OF REINFORCING BAR MIN 6"_,,- T LOCATION OF BAR (T=TOP, B=BOTTCM, M=MIDDLE; 16 INDICATES BAR SPACING IN INCHES TYPICAL STRUCTURAL * ON GRADE 'W BARS TAIR MIN 6" LN-2 LAP SPLICE LENGTHS BAR NO. fc' 3 1 4 5 6 7 8 9 10 COMPRESSION LAP SPLICE ' 3000 12 15 19 23 27 1 30 34 39 CLASS A TENSION LAP SPLICE 3000 13 17 21 25 36 42 47 53 4000 11 15 18 22 32 36 41 46 5000 10 13 16 20 28 32 36 41 CLASS B TENSION LAP SPLICE 3000 16 22 27 33 47 54 61 68 4000 14 19 23 28 41 47 53 59 5000 13 17 21 25 37 42 47 53 LN-3 CANT SCALE 1/2"=V-0" REVIEWED FOR CODE COMPLIANCE ST, LUCIE COUNTY BOCC 2101-0347 T` _^.-: Building Mike Halter _j "w. 1011512021 NCE V APPROVED ❑ APPROVED AS CORRECTED ❑ REVISE AND RESUBMrT ❑ FOR YOUR INFORMATION AND USE Q INCOMPLETE SUBMITTAL ❑ NOT APPROVED Checking is only for conformance with the design concept of the Project and compliance with the information given in the Contract Documents. Contractor is responsible for dimensions to be confirmed and correlated at the job site; for information that pertains solely to the fabrication processes or to techniques of construction; and for coordination of the work of all trades. ,�-- B7T0Y ch rk1E Date /Z MK STRUCTURAL ENGINEERING 587 WEST EAU GALLIE BLVD SUITE 201 MELBOURNE, FL 32935 P: 321,600.0672 OR 321.574.2702 www.mkstructural.com Certificate of Authorization#: CA 27800 project number 21-152 38 SOVEREIGN WAY FT PIERCE, FL 32949 issued for date PERMIT SET 06/16/2021 This document is the property of MK Structural Engineering. MK Structural Engineering retains all rights therein, including copyrights. It is not to be reproduced or copied in whole or in part. It is not to be used on any other project and is to be. returned upon request. It may only be used in a manner consistent with MK Structural Engineering's rights while MK Structural Engineering is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation lo, MK Structural Engineering. Unauthorized use will be prosecuted pursuant to the copyright laws. scale AS NOTED sheet title STRUCTURAL NOTES Michael seal/signature ����rttlll�f�9� ,C _ No. 133 MICHAEL A. KALAd IAN ° FL. REG. N13. #601 3°i °ATE: AL G 1 2, 2021 STATE OF N® NAL Registered Engineer: Michael A., Kalajian Registered Engineer License: PE 60133 sheet number > drawn by: NMC checked by:11AK s_ by MK Structural Engineering, LLC. all rights reserved. WHEN PLOTTED AT FULL S17E THIS SHEET M EASU RES 24' x 36' Vvk3;. STRUCTURAL ENGINEERING- MK STRUCTURAL ENGINEERING 587 WEST EAU GALLIE BLVD SUITE 201 A B QC Ei F G H J L MELBOURNE, FL 32935 P: 321.600.0672 OR 321.574.2702 www.mkstructural.com 20'-4„ 4,-4„ T-g„ 2'-108" 14'-58" 9'-4" 5'_2" 41-6" 10" 10' 6" Certificate of Authorization#: ol CA 27800 project number - 1 NED2 /� REf e 0 38 SOVEREIGN WAY FT PIERCE, FL 32949 14" DIA issued for date I 3 PERMIT SET 06/16/2021 This document is the property of MKStructural Engineering. MK Structural Engineering retains all rights therein, including copyrights. It is not to be reproduced or copied in whole or in 14" DIA. AUGER CAST part. It is not to be used on any other project and is to be PILING, SEE DETAIL A/S2 �\ returned upon request. It may only be used in a manner TYPIC-AL consistent with MK Structural Engineering's rights while MK Structural Engineering is providing services forthe specific 4 - - 1 OP OF P1LF_ project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the 4 express written agreement of, and compensation to, MK Structural Engineering. Unauthorized use will be prosecuted ° pursuant to the copyright la fs. OEM revisions 56 KIPS COMPRESSION, 14" DIA AUGER CAST PILE 4° W/5,000 PSI GROUT item description description date L a I � RIEVIISIONS 08/12/21 (V 5 Al- S Z W J x O a a i DISCONTINUE #7 BAR AT 5'-0" a =' ABOVE BOTTOM OF PILE scale m N AS NOTED j a 9 sheet title 14 PILE Lp"'YOUT 4 a f] t PLAN in iL PILE TIP i� ib iti I � A TYPICAL PILE ET)t' 1 L — SCALE 1/2"=1'-0" seal/signature �! T, 48" 11t!!!lt f SP J� 1 0 _ No.61 ° MICHAEL A. KALAJIAN REGr, . NO. #n 1 3:� E: AL n 1 2, 20210 ti ® SATE of ,° YONAL PILE LAYOUT PLAN SCALE 1/4"=1'-0" Registered Engineer: Michael A. Kalajjan Registered Engineer License: PE 60133 sheet number S2 drawn by: NMC checked by: MAK by MK Structural Engineering, LI C. all rights reserved. WHEN PILOT= AT FULL S!ZF TI IIS SHEET MEASURES 24" x 36" NDATION WORK SHALL NOT BEGIN UNTIL kL ARCHITECTURAL DRAWINGS AND OTHER ISTRUCTION DOCUMENTS ARE REVIEWED -HE ENGINEER OF RECORD TO VERIFY NDATiON DESIGN FOUNDATIONS ARE JECT TO CHANGE: BASED ON ERSTRUCTURE LOADS PROVIDED IN 2. VERIFY ALL WINDOW AND DOOR OPENING LOCATIONS WITH FINAL ARCHITECTURAL PLANS GRADE BEAM PLAN SCALE 114"=1'-0" STRUCTURAL -:.m ... MK STRUCTURAL ENGINEERING 587 WEST EAU GALLIE BLVD SUITE 201 MELBOURNE, FL 32935 P: 321.600.0672 OR 321.574.2702 www.mkstructural.com Certificate of Authorization#: CA 27800 project number MK 21-152 38 SOVEREIGN WAY FT PIERCE, FL 32949 issued for date PERMIT SET 06/ 16/2021 This document is the property of MKStructural Engineering, MKStructural Engineering retains all rights therein, including copyrights. It is not to be reproduced or copied in whole or in part. It is not to be used on any other project and is to be returned upon request. It may only be used in a manner consistent with MK Structural Engineering's rights while MK Structural Engineering is providing services forthe specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, MK Structural Engineering. Unauthorized use will be prosecuted pursuant to the copyright laws. scale AS NOTED sheet title GRADE BEAM Al seal/signature _ No. 60133 MIGHAEL A. KALAJIAN ° w•.d ° FL. REG. NO. #r 601 S:� XZ ° eDATE: AL Ii 1 2, 2021 STA7E OF YONAL tll{4� Registered Engineer: Michael A. Kalajian Registered Engineer License: PE 60133 sheet number drawn by: NMC checked by: MAK by M K Structural Engineering, LI C. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES ?4" x 36" 2-0" W A 4 W � d 4 4 d d 1. a 4 4 a a d c 4 C a 4 a d d d a -- -- \ (3) 93 STIRRUPS AT BEAM STEP IE as WW m0 CONTINUE E LAP: 8" MAS FORM AND I CURB GRADE BEA _a Q d d d o 4 d A � S a a W W d �m Q a � 4 STEP REIONFORCING AS REQUIRED FOR STEP IN BEAM TYPICAL STEP IN GRADE BEAM #5 AROUND DEPRESSION #5 Z-BAR TOP @ 12" O.C. AT DEPRESSION 4 • a a a 61'STRUCTURAL SLAB TYPICAL SLAB DEPRESSION SCALE 3/4"=1'-0" TOP OF SLAB SEE PLAN SCALE 3/4"=V-0" STRUCTURAL SLAB TOP OF SLAB SEE PLAN SCALE 3/4"=V-0" PILE OR COLUMN SIIPPCRT TERMINATE ALL LONGITUDINAL RADE BEAM REINF W190° HOOK 10" VERIFY W/ DOOR MANUF GRADE BEAM, SEE P LA'v GARAGE GRADE BEAM STIR CTURALSLAB,SEE FOL,ADATICN PLAN INTERIOR GRADE BEAM HOOK PILE REINF IN nIOCnTlnnl nc (^-DA n= TOP OF SLAB SCALE 3/4"=1'-0" TOP OF SLAB SEE FLAN SEE SCALE 3/4"=1'-0" SCALE 3/4"=V-0" GRADE BE GRADE BEAM, SEE STEP IN SLAB SCALE 3/4"=1'-0" TOP OF SLAB SEE PL^,Nfr m¢ U —J D U) J a 0 m �a fy GRA r STRUCTURAL SLAB, SEE SCALE 3/4"=1'-0" TOP OF SLAB SEE PLAN J rn �a �U) U) SCALE 3/4"=1'-0" FOR ALL PILES THAT TERMINATE BEAM IN GRADE BEAMS, HOOK PILE WIDTH REINF W190° HOOK IN DIRECTION\ OF GRADE BEAM GRADE BEAM, SEE SCHEDULE FOR REINF STEP IINISLAB STRUCTURAL SLAB, SEE PLAN FOR REINF AUGER CAST PILE FORM GRADE BEAM _FROM SOIL IF FROM UNEXPOSED SCALE 3/4"=V-0" 8" MAS GRAD EXTERIOR GRADE BEAM 8" MASONRY WALL BY OTHERS STRUCTURAL SLAB, SEE ,FOUNDATION PLAN W f TOP OF SLAB F I TOP OF SLAB SFF PLAN SE PLAN - d i J Q 4 ' 4 a J D d d / Dm \ ° e H¢ DU) U) GRADE BEAM, SEE PLAN-� T \ SCALE 3/4"=V-0" STEP IN SLAB AUGERCAST PILE SCALE 3/4"=V-0" TOP OF SEE PLAr SCALE 311 38 SOVEREIGN WAY FT PIERCE, FL 32949 issued for date PERMIT SET 06/ 16/2021 This document isthe propertyof MKStructural Engineering. MK Structural Engineering retains all rights therein, including copyrights. It is not to be reproduced or copied in whole or in part. It is not to be used on any other project and is to be returned upon request. It may only be used in a manner consistent with MK Structural Engineering's rights while MK Structural Engineering is providing services forthe specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, MK Structural Engineering. Unauthorized use will be prosecuted pursuant to the copyright laws. FOUND/NTIO'NIN seal/signature No.60133 ° MICHAEL 1, KALGJIAN NO.6❑ 1 3 1 ✓ � ^DATE: AL G 1 2, 2O210 .,y STATE OF ° i fiLOdtID�`°•°°°o��� Registered Engineer: Michael A. Kalajian Registered Engineer License: PE 60133 Sheet number S4 drawn by- ItiIMC — checked by: MAK by MK Structural Engineering, Ll C. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 24" x 36"