Loading...
HomeMy WebLinkAboutCONSTRUCTION PLANFL00R PL�4N '1R,4SH POST DET/41L 22'-O" TYPICAL NOTES: SCALE 1/4" = 1'-0" I. Contractor to Verif ALL notes and dimensions prior to � p Water Heater 3l0" high by 4" diameter N_T.S. proceeding with work. steel crash post. Floor 2. Contractor to STRICTLY enforce ALL OSHA requirements. Flange with 4 - 3/8" 3. ALL Lumber to be used as Beam, rafters, etc... t0 have expansion bolts into (3/8"t 50 ksi steel plate) ,AREA CALCULATIONSslab a minimum 1,400 F.S.I. fiber stress. 611 Living A/C = 1839 sq. ft. 4. No dissimilar metals to touch. ront Porch = FrontRear 2,o sq. ft. S. ALL Concrete used for Slabs Shall be min. 2,500 PSI concrete. %2 2% 2%' Porch = 100 sq. ft. ALL Concrete used for vertical filled cells, cont. tle beams etc., to o I Garage = 311 sq. ft. shall be 3,000 P.S.I. concrete and/or 4,000 F.S.I. grout mix �, o 6. Drywall at ceilings shall be leveled and attached to bottom chord �3�8„ 2%" Total Under Roof= 2,282 sq. ft. of trusses with screws per FBC r-102.3.5. 2%' Total Cubic Pt = 15,581.E 1. ALL wood in contact with concrete shall be pressure treated. o 0 8. ALL wall dimensions are nominal and not finished wall or stud dimensions. 9. ALL plumbing fixtures to be low flow. Install doors thru buck Into 10. Contractor to Provide Drain at water heater in accordance block using tapcons as stated in product appproval form on sheet I. with the current edition of the Florida PIUmbin Code Exterior face Buck to be Z' x 6" PT g 11. Contractor to Provide a 2'-8" wide door at one bathroom for handicap accessibility requirements. 2%2" 2%2" 12. Lowest finished floor to be set by Governing Building Department surveyor to set in field. 13. Separation between residence and garage shall be per FBC r302.� 14. Door between garage and residence shall be 1-3/4"t 20 min. rated door 15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 pper FBC r302.9.1 1�. Wall and ceiling finishes shall have a smoke -developed index of not greater than -4 per FBC R302.9.2 1_t All ex osed attic insulation materials installed on attic floors shall have a critical radiant Detail at Door flux note less than 0.12 watt per square centimeter. Exposed foam plastic insulation INSTALL VULKEM BLOCK SEALANT materials exposed on the underside of the roof deck pR31� or on the attic walls shall comply y p ON ALL JAMB, HEADER, AND BLOCKT TO BUCK with F.B.C. - See permit info box of code edition ONRIOR INSTALLATION 18. Gypsum board material shall conform to ASTM C3�, C19, C415, C514, C�30, C931 C��O, C1002, C1041,C1111, C1118, C1218, C1395, or C139and shall be installed according to the following: (FBC r102.3.5) I" x 4" P.T. Buck nailed to Or wall y Thickness Location Orientation Framing Spa Max. spacing P 9 of fasteners Nail sizing options for installation of drywall into in9 Nails Screws Maximum wood framing members 2" x min. thickness Ceiling Perpendicular 24" -1" 12" 13ga 1 3/8" long with 19/64" head 0.098" diameter x 1 1/4" long II )/2 annular -ringed or 5d cooler nail OR Walls Either 16" 8" 16" 0.080" dia. xx 1 6/8" long with Direction 15/64 head OR Gypsum board nail 0.086" dia. x 1 5/8" with 9/32" head. Ceiling Perpendicular 24" -1" 12" 13ga 1 5/8" long with 19/6,V head 0.098" diameter x 1 3/8" long s II annular -ringed or 6d cooler nail OR Walls Either 16" 8" 16" 0.092" dia. xx I -1/8" long with Direction 1/4 head OR Gypsum board nail 0.0915" dia. x 11/8" with 19/64" head. Masonry Beam block with case hardened nails prior to door attachment I" x 4" P.T. Buck nailed to block with case hardened nails prior to door attachment head and jambs p O O Masonry Wall Install SGD Frame thru buck Into block using tapcons as stated in product approval form on sheet I. Verify sill attachment req. with product approval on - sheet I. Head sliding door Install SGD Frame thru buck into block using tapcons as stated in product approval form on sheet I. Typical Flooring Jamb :t approval for i Into wall req. NTS Sliding Door Detail 2"F-- 1 2„ At Masonry Wall NTS 3' LIAV-1 I ' - _1 Bottom Track 19. ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.�, A108.1, A118.1, A118.3, A13LI and A131.1 20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM C1288, C1325, Or C1118 and installed I.A.W. manufacturers recommendations shall be used as backer for the wall tile in tub areas and wall panels in shower areas. 21. Insulation including facings such as retarders or vapor permeable members installed Install windows thru buck into within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics block using tapcons as stated shall have a flame spread index not to exceed 25 with an accompan ing smoke Exterior face in product approval form on sheet �. p F ASTM E 8 4. of wall Varies develo ed index not to exceed �450 when tested in accordance wit . �• - Insulation shall comply with F.B.C. r31�. s / Window Schedule Mark Size Rough 0 en. Window Description PRESSURE ZONE I. 4'-5%8"x 5'-3 %8 54%,'x 63i4" Single Hung ZONE 4 2. 6'-2%8"x 5'-3 %8" is" x 63 %4" Single Hung ZONE 4 3. 2'-2" x 3'-2 1/2" 271%2"x 38%" Single Hung ZONE 4 4. 4'-5%8"x 4'-2 %" 54%,'X 50%, Single Hung ZONE 4 S. 6'-O%"x 4'-2%" 15%"x SOY8" Single Hung ZONE 4 ALL Windows to be aluminum windows w/ tint and mullions per elevations. ALL windows to withstand pressures in permit info box on ALL windows in bathrooms to be tempered All rough opening dimensions to be verified by contractor with manufacturer s specs prior to construction sheet [Door Schedule Mark Size Rough Opening Door Description PRESSURE ZONE A 9'-0" X -1'-0" 108" x 84" Overhead Garage Door IMPACT RATED ZONE 4 B 3'-0" X 6'-8" 41 %4""x 8374"' Fiberglass Panel - Inswing IMPACT RATED ZONE 4 C 5'-O" X 6'-8" 62" x 83 %2" " Single Lite French 9 IMPACT IMPACT RATED ZONE 4 D 21 -O" X 6'-8" Solid Core - Wood - 6-Panel -Bi-Fold Finished 24" x 81 %2" E 2 -6 X 61-811 Solid Core - Wood - 6-Panel F 6'-0" X 6'-8" Solid Core - Wood - 6-Panel - double pocket G 2'-8" x 6'-8" x 1 %4" Solid Core Wood, Steel, or Masonite Door H 2'-8" X 6'-8" Solid Core - Wood - 6-Panel i 2'-6" X 6'-8" Solid Core - Wood - 6-Panel - Bi-Fold K 4'-0" X 6'-8" Solid Core - Wood - 6-Panel - Bi-Fold L 1'-6" X 6'-8" Solid Core - Wood - 6-Panel - Bi-Fold ALL Exterior doors to withstand pressures stated in permit info box on sheet 91 GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET 41 All rough opening dimensions to be verified by contractor With manufacturer s specs prior to construction I"x4" P.T. Buck nailed to block with case hardened nails prior to window attachment Detail at Windows NTS JAV-1 2" MASTER BATH 2" O 2" AAV WM_1 jIL we-1 2" LAV-I 2" 2 KITCHEN `hwr-' i I LAUNDRY 2"1 I � I i LAV -1 O I 2 POWDER °�° WC-12' VTR �„ J1 2"I\ � MASTER WC-1 II 2" ' BATH #2 3 L�4V-I I UAV-1 C.O. 2" CMNRCT TO PLUMBING RiSER Metal roofing and underlagment intstalled per Product Approval as shown on sheet I over CDX decking - see roof sheeting attachment diagram on roof plan. Simpson HETA 20 or equal hurricane anchor at each truss with 00) Iod x 1 1/2" nails 12 ( 24" o.c.) supporting Max. -ENGINEERED TRUSSES 1810lbs. uplift 4 at 24"o.c. TYPICAL (shop drawings by manufacturer) Aluminum Drip Edge t Fascia R-20 Spray foam insulation 2" x 6" Sub -Fascia 12" 1/2" drywall with texture finish Two rows of beam block filled with concrete 5/8" thick stucco on 3/8" hi -rib lath and (1) 45 bar Cont. in each row. Substitute attached to horizontal and vertical wood precast lintel filled with concrete and (1) 45 framing with nails or staples to provide bar cont. for bottom row over openings no less than I-3/4" penetration into horizontal wood framing and 3/4" 1/2" drywall over I" x furringg penetration into vertical wood framing strips at 16" o.c. with R4.1 fI-foil members. insulation on typical 8" Block walls 5/8" thick light textured - All drywall to be Installed per FBC R102.3.1 stucco on typical concrete 1 and shall meet all pertaining ASTM codes. block construction 00 Mortar to be Type "M" only proportioned per FBC R601.1 and Mortar joints shall comp y with FBC R6071.2.1. Provide Our-O-Rock at all wet areas (ex. showers, tubs etc...) 45 bar vert. w/ 30" overlap Fill cell with grout and at each filled cell (1) 45 bar vert. (typical). Max, spacing shall not exceed Wood 481, unless otherwise noted see foundation plan notes for ase spacing at openings 4" concrete slab with fibermesh OR 6"xC 1*10/10 WWM on 4 mil Visqueen over clean compacted termite treated fill as Grade _ 14"w x 18 Concrete footing ttransverse bars at48" (5 soand #5 TYFIC/4L SECTION Scale : 1/2" = 1'-0" 12' 0" cy Li 00 O I ===10 I 1 01 1 1 00 00 00 V EGRESS r----- - - - - - - I SiTTIN o Covered Porch ROOM N_ I OD - C � I MASTER I ° 0 I BEDROOM I 00 0 0 0o I o 8'-6" A.F.F. - Coffer Ceiling I I ao 8'-0" to 9'- A.F.F.LL I O Vaulted ailing G - - - - - - - - J Gr AT � m OI O M Rod Shelf < J ° � crl 00 I - <r cn I - 00 Vanity to 34 %2 "" high e H.B. N I 8'-0" to 9'-8" A.F. 2" x 6" knee -wall w o SET ° Vaulted Ceiling below counter top tK O Mirr r I I N 0 v Q� •• U d) o N I � N N cY = �O �[il oN�0 N U 4--) � Cr f U ) U U R O O M L LIN18EN � a�F 8 Rod Shelf O ABINET 0 o n� IIL I BAT `J 34 3/4"h i� ° Adjust wall W m C)I knee wall I len ht as n eded . *t I ° _ Po O � � Adjust wall 1 �0 K lG , C H E N ° O O lenght as needed N Vent ryer Q I I I 0 for tub throug wall Jul U A.F.F. 6 4" �{ -5" 4I I'-�," Overhang Flat Ceiling 12" - -JEC Upper cabinets to N extend over Ref. - � N 2" fillerN I I IRef. _■�■LL ATHOW� � � -II Bat s insulation O A / C O �J #I LL is6 IN " 1 -- ABINE - HO r W 22" x 54" 1 Provide auto N -t � Attic Access closer `r Rod & Shelf l O l n q I with light 1 0 0 - - - - ,� = I L - - 2F"S�ee� Ballard W U anitg to be v Q Q See detail on this sheet (� Z ui O ° 34%2"high C OSET I �, -� I 15Panelp Meter z W 00m 13 O Ln 00 < } CA H.B. m 0� I < 00 00 U GARAGE < ° 8'-4„ A.F.F. O O 1 Z ci (I# Flat Ceiling _1 O a� N (17 N O rr OD U O �!J o U Co ~LL r� - - - - - - - O B r-----------------� O - x 0 E ERGEN Y I Block wall in I= LLI M LL GRESS I garage to be I <r LL U ~ N O I I 0 0 T D D I struck block I O L�4� r N I JUNIOR I o o � � � <� � MASTER I C P/ cH° SEDR00M _ I 92 O ' 1' D O D D (( O O 0 0 Coffer Ceiling 2"_7„ 3,_5„ >< J 5'-2" I Eo 1 SHEET NO: L---+2'-8"---� :2. 00 00 00 00 OF S. 2. �'-o" �'-o" JOB NUMBER: 21-2�0 B ����O.D00000 0 Digitally signed ��oa o ��� R. o�®� o o° ® � 1 Daniel R. y ®® b Daniel R. q.� . AR9770 00� 0 Braden o0 Date:2021.11.22 ��o��Q��.fo-ol °o Braden �1+4 SPANISH LAKES BLVID 11•�n•/11 _n�inni oo�,�,,,,r,�aQ FCUN[DA7CN PLAN STRUCTURAL MOTES: 1. ANY CHANGES TO THE PLANS MUST BE SUBMITTED TO THE ARCHITECT FOR APPROVAL BEFORE PROCEEDING WITH CONSTRUCTION 2. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL NOTATION AND DIMENSIONS PRIOR TO START OF CONSTRUCTION 3. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN PROPER ENGINEERING DATA FOR DESIGN. 4.. ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS 5` POISON SOIL AND COVER W/ MIL. VISQUEEN WITHIN 24 HOURS. NO SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION. SLAB ON GRADE TO BE A MINIMUM 4" THICK W/ 6X6 10/10 WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL (MINIMUM 96% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH. LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS BEFORE FILL IS BROUGHT IN. FILL MATERIAL SHALL CONSIST OF CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE STRUCTURAL FILL IN LOOSE LAYERS OF 12" IN THICKNESS AND COMPACT EACH LIFT TO AT LEAST 95% OF ITS MODIFIED DRY PROCTOR VALUE. 8. GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE ATTENTION OF THE ARCHITECT. q. GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR 10. CONTACTOR TO VERIFY ALL RECESS THICKNESSES AT SHOWERS FLOOR FINISH CHANGES, SPECIALTY EQ. ETC... 45 bar vert. w/ 30" overlap Fill cell with concrete and at each filled c (1) #5 bar vert. (typical). Max. spacing shall not exceed 48" unless otherwise noted SCALE: 1/4" = I'—O" II. SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS 12. CONTRACTOR TO PROVIDE SOLID FILLED CELL AND U5 BAR VERT. AT 48" O.C. MAX. PROVIDE (1) FILLED CELL ON EACH SIDE OF OPENINGS UP TO 5'-11" WIDE. PROVIDE (2) FILLED CELLS ON EACH SIDE OF OPENINGS 6'-O" WIDE AND UP. VERIFY ALL FILLED CELL LOCATIONS WITH FOUNDATION PLAN. 13. DESIGN LOADS ARE AS FOLLOWS: SEE PERMIT INFO BOX ON SHEET I. 14. ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-I6, t A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL. I5. ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE. FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS, SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE. 16. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: FOOTING: 3" BEAMS: 1-1/2" 1� LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS. 18. USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1600 PSI 19. ALL STANDARD STRUCTURAL LUMBER SHALL BE SYP WITH A MINIMUM SOUTHERN YELLOW PINE 42. MIN. Fb AS FOLLOWS: 2" x 4" = Fb 1,500 PSI 2" x 10" = Fb 1,000 PSI 2" x 6"/8" = Fb 1,200 PSI 2" x 12" = Fb 915 PSI 20. ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING. 21. CONTRACTOR TO PROVIDE FORM BOARD SURVEY AND FURNISH TO TRUSS MFG PRIOR TO TRUSS CONSTRUCTION FOR ACCURACY TO FIELD Termite Protection for New Construction as per F.B.C. R318.1 CONTRACTOR TO REFERENCE F.B.C-R FOR FURTHER REQUIREMENTS Wood see foundation plan notes for Thicken edge to 8"x8" Base spacing at openings with concrete and 4" concrete slab with fibermesh OR +" concrete slab with fibermesh OR one 45 bar continuous 6' x0/10 WWM on 10over 0emil Visqueen #10/10 WWM on 6 mil Visqueen over pacted ll 6 x6 clean clean compacted termite treated fill GRADE Grade _ II - II —IIII IIII- wiith (2)8#5 ba scc nt.f andn#5 IIII IIII 3„ transverse bars at 48" o.c. 3" 14„ 1 TYPICAL FOOTING DETAIL J SCALE 1/2" = 1'-0" 4" concrete slab with fibermesh OR 6"x6" #10/10 WWM on 10 mil Visqueen over clean compacted termite treated fill #5 bar cont. Step per foundation plan 3' X 3" '(2) #5 bars cont. bottom steel M1� �2" (F 2) DETAIL AT GARAGE STEPDOWN SCALE 1/2" = 1'-0" 12" x 12" concrete column block felled with concrete and (2) #1 bars vert. tied into lintels above Top of Tooter 16" below finished floor - 3' 30" COLUMN FOOTING DETAIL SCALE 1/2" = 1'-0" I.... I_4III1...... I-81 PORCH SLAB EDGE DETAIL SCALE 1/2" -- r-O" 45 bar vert. w/ 30" overlap at each filled cell 45 bar cont. in curb Fill cell with grout and (1) 1*5 bar vert. (typical). Max. spacing shall not exceed Curb height Wood 48" unless otherwise noted Verify based on see foundation plan notes for foundation plan Base spacing at openings 4" concrete slab with fibermesh OR 6 x6 #10/10 WWM on 6 mil Visqueen over `r clean compacted termite treated fell Grade — 'I L11 7 ILI T I III�- 'II III'- 14"w x 18"d Concrete footing with (2) #5 bars cont. and #5 '3 transverse bars at 48" o.c. lie �4 14" GARAGE CURB DETAIL Min. SCALE 1/2" = I'-O" Edge 18L E Q cil Contractor to provide proper foundation chairs for proper steel installation 30 min. 2" x 6" PT wood secured with \ Corner Steel L a p 1/2"dia. x 6" expansion anchors with 2" sq. washer at 18" o.c. overhead door track secured to wood n t S jamb per manufacturer's product approval Garage Door Jamb Detail GARAGE DOOR TO WITHSTAND PRESSURES STATED N T S IN PERMIT INFO BOX ON SHEET 41. SEE PRODUCT APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL. FCCT1NG SCHEDULE Mark Size Description FI 14"W x 18"D MONOLITHIC FOOTING WITH 2 45 BARS CONTINUOUS F 12"W X 12"D MONOLITHIC FOOTING WITH (2) 45 BARS CONTINUOUS 30" x 30" x 16"p COLUMN FOOTING WITH (4) #5 BARS EACH WAY F4 8"W x 8"D THICKEN SLAB EDGE WITH 1 45 BAR CONTINUOUS 14"W x 18"D FS MONOLITHIC FOOTING WITH 2 #5 BARS CONTINUOUS - CURB 9 O'-O" With Curb at Garage Filled Cell Masonry Column With One U5 From Footing To Beam Each. Filled Cell Masonry Column With One Grout fill To Be 3000 PSI 45 From Footing To Tie Beam See Floor Plan For Location Grout fill To Be 3000 PSI Double Filled Cell Column NTS See Floor Plan For Location Eo A Single Filled Cell Column NTS 0 O 00 12" I Y 9,_0„ w 0 F4 � ° _F — — — — — —" L I� cc I� o cn Rear Patio/Slab to be poured separate from the house slab. ElEl 101 12'-8" 22'-O" 2 _O„ F41 r— — — — — — — — — — — — — — — — — — — — — — O I 8 I Filled cell under FI girder above IN r Thicken footing to I O 24"w x 14"d x 24"L under filled cell FI under girder bearing. J I° I° o ° I H.B. 4" concrete slab with fibermesh OR 6"x6" 410/10 WWM on 6 mil Visqueen over C), clean compacted termite treated fill FI I I Fo / F- V 0 o to 0 FI �I to OoH. a -------- A/C 0 I I 4"(P Steel Ballard ®felled w/ Concrete v� Q) N E t! E I I N E� w °Q 1 O QJ E? I r- CL E N FI Ioo o0I O ° CIL o D I x I � o O D L — — — — — — — — — — — _J O D D Recess for 101EI 0 0 FI I I Garage Door I I I FI L— — — — — — — — - - T- T- T- T- - T- T- T- T 1 1 1 1 1 1 1 1 1 J 14'-0" 5'-2" 15'-10" v 1J U� OD O �r m N 0 m I 0 Digitally signed Daniel R. by Daniel R. Braden Braden Date: 2021.11.22 11:50:31-05'00' N 0 v QC Q� •• U O N I N v nc I = O LJ J N U 41 � a7 U - Q U Q- �_ _l O U� �J �w U LU Ll W N [L nc w m w =3 u O ZI? ao CO U O < > Ln O < p- r r L < Z0000 CA N #* ~ OCo rr� W x -1 Q1 Q) LL Q.� SHEET NO: - OF 5. JOB NUMBER: 21-2SO B 1` o AGE 9770 -C oQ 000 °o°a°°a � \`l . " �� Q .nn Provide 45 bars with 12" min. lap into beam and 48 bar dia. into vert. filled cell. Provide Cast -Crete 8U16-I13/IT precast - lintel set in mortar Min. 8" Bearing Fill lintel solid with grout. #5 cont, beam steel to run through lintel and tie to down rods in jamb cells. Provide PT Buck attached per jamb letails into filled ce 4" Pre -cast Sill rout Filled Cell Provide 45 bars with 12" min, lap into footing and 48 bar dia, into vert. filled cell. Concrete Footing See foundation plan for for exact sizes DETAIL AT WINDOW CFENING IN CBS WALL Concrete i Lintel Column Scale: 1/2" = I'—O" Verify with Plan V1 Rebar to Lint&l 12 "x 12" Column Block Rebar 48 Bar Dia. Min. Overlap /4ttachm&nt NTS SEAM SCHEDULE Mark Size and Descrl tion Two rows of beam block filled with concrete and 1 45 bar BI continuous in each row. Hook vert. bar over top bar with 45 90' bend bar with a 10" min. lap at top bar. Additional Precast Lintel „ „ #5 bars Lintel Bar Clear A B .� r. .� �'•� .CLEAR Length Length Span Bars Bars r' 2'-10" 2'-8" I'-6" 2,#3 none i• ` i i'�i i .• i 3'-4" 2'-2" 2,U3 none 8F8-OB/IT 8F8-IB/IT 8F8-IB/2T Additional 3'-10" 2'-8" 2,u3 none #5 bars CLEAR :':^:'...'.':' %.:.�:, 4'-6" 4'-4" 3'-2" 2,#3 none One Row of "H" " Block Above 5'-2" 4'-O" 2,U3 none M ..( Precast Lintel none Additional 2,#4 none #5 bars _1'-O" 6'-2" 2,#5 none 8FI6-IB/IT 8FI6-IB/2T NOTES: 2,#5 none I. min. coverage of stee1=1.5" 2. min. bearing required 8 ea. end=8" ALL reinforcing steel is grade 60. 3. standard for reinf. steel=ASTM A615 TYPICAL LINTEL SECTION ( PRECAST CONCRETE > LINTEL SCHEDULE Mark Window or Doo Unit Width Lintel Size Specification Rows of "H" Block Above �� �� Bottom Steel Size Top Steel Size Max. Gravity Load (PLF) Max. Uplift Load (PLF) Max. Lateral Load (PLF) L22 2'-2" V-6" 8FI6-IB/IT ONE 1 #5 1 #5 6113 3541 2854 L31 2'-6" 2'-8" 3'-1" 4'-0" 8FI6-IB/IT ONE 1 #5 1 #5 2931 3019 2128 L45 4'-5" 5'-10" 8FI6-IB/IT ONE 1 #5 1 #5 4360 2093 946 L50 5'-0" 6'-6" 8FI6-IB/IT ONE I #5 1 #5 3480 1880 1204 L60 6'-8" l'-V 8FI6-IB/IT ONE I #5 1 #5 2661 1634 891 LSO 8'-0" 9'-4" 8FI6-IB/IT ONE I #5 1 #5 1843 1133 -139 L90 9'-O" 10'-6" 8FI6-IB/IT ONE I #5 1 #5 1533 914 519 L90B 9'-0" 10'-6" 8FI6-IB/IT ONE I #5 1 #5 1533 914 5i9 LI00 10'-0" ll'-4" 8FI6-IB/IT ONE I #5 I #5 1366 198 604 LIOOB 10'-0" ll'-4" 8FI6-IB/IT ONE 1 #5 1 #5 1366 198 604 L120 12'-0" 13'-4" 8FI6-IB/IT ONE 1 #5 1 #5 1016 606 433 L120B 12'-0" 13'-4" 8FI6-IB/IT ONE I #5 1 #5 1015 606 433 L140 14'-0" 15'-4" 8FI6-IB/IT ONE I #5 1 #5 1250 485 341 LI60 16'-O" I-l'-4" SFS-IB/IT ONE I #5 1 #5 950 404 25� LI60B 16'-O" I-l'-4" 8FI6-IB/IT ONE I #5 1 #5 950 404 25� - ALL LINTELS SHALL BE MADE BY CAST-CRETE OR LOTTS LINTELS - LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE - REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ. REQUIREMENTS - LINTELS OVER 14'-O" LONG ARE TO BE PRESTRESSED. HIP ROOF SHF_F_TING ATTACHMENT DETAIL I. Minimum Nail Size = 8d angular ring shank (min. 2.5" long) 2. Minimum Screw Size = #8 x 2.5" 3. Minimum Sheathing Thickness 19/32" CDX Plywood 4. Use nails or screws based on pressure for roof stated in grmit info box on ones. these plans for appropraite roof 0 4 FT 2E TYPICAL GABLE 2N Q� 2 TYPICAL 3® 4 FT R ZE 2R 4 FT F u_ 117 4 FT gQ 4 FT ZE 4 FT Area Edge Field Fastener Pressure M Zone I 8d x 2.5" ring shank 45 psf Zone 2E, 2R, 2N 8d x 2.5" ring shank i6 psf Zone 3E/3R 8d x 2.5" ring shank 84 psf ANY ZONE #8 x 2.5" Screw 263 psf SINGLE PLY REAR GIRDER TRUSS Nail 2" x 4" blocking to vert. leg of truss with IOd x 1.5" nails at 4" o.c. Install Simpson MGT into wall usingg 5/8" dia. threaded rod set min. 12" into wet beam and (22) IOd nails into truss _OCKING DETAIL =R STRAPPING ER BEARING POINT 1/8" thick light textured stucco installed per ASTM C 926 over ASTM D type 2 paper backed wire lath nailed to substrate through one layer of ASTM D Type 2 felt paper using 8d nails. Substrate to be 19/32' COX Plywood nailed at 6" o.c. in field and edges with IOd ring shank nails into studs. Metal roofing and underlayment intstalled per Product Approval as shown on sheet I over COX decking - see roof sheeting attachment diagram on roof plan. \ Simpson HETA 20 or equal hurricane anchor at each truss with (10) IOd x 1 1/2" nails ( 24" o.c.) supporting Max. 18101bs. uplift Aluminum Drip Edge & Fascia 2" x 6" Sub -Fascia 5/8" thick stucco on 3/8" hi -rib lath attached to horizontal and vertical wood framing with nails or staples to provide no less than I-3/4" penetration into horizontal wood framing and 3/4" penetration into vertical wood framing members. 12" x 12" concrete column block filled with concrete and (2) #1 bars vert. tied into lintels above thicken edge to 8"x8" with concrete and one 45 bar continuous BEYOND Finish column with Smooth stucco per elevations Top of Tooter IC' below finished floor 4 12 4 Aluminum Drip Edge (: Fascia Flash and Counter f lash Nail ledger to gable end truss with (2) IOd mails at each web \ R -19 t Ce111n transition Trusses at 24" o.c. re shop drawings I others ceiling transition !f ded using metal studs erify exact configuration :e s Drywall ceiling see typical section nsulatlon Detail nts Simpson HETA 20 hurricane anchor at each truss (z 26" Batcs) supporting Max. 1810 lbs. uplift -19 batts Metal roofing and underlayment intstalled per Product Approval X as shown on sheet I over COX decking - see roof sheeting attachment diagram on roof plan. +' � � O W L R Brace Gable end = `n N � with 2" x 4" SYP 42 U .. 8ft back nailed to bottom of top chords using (2) IOd o U O nails at each truss N O a Q) 00 E _ — � N L R-20 Spray foam insulation C PRE-ENGINEE�D WOOD TRUSSES e 24"o.c. TYPICAL ( shop drawings bg manufacturer ) -1/2" drywall with texture finish Two rows of beam block filled with concrete _and (1) 45 bar cont, in each row. Substitute Ear lintel filled with concrete and (1) 45 bar cont, for bottom row over openings 1/2" drywall over I" x furringg strips at 16 o.c. with R4.1 Pi -foil -insulation on typical 8" Block walls All drywall to be installed per FBC R102.3.1 and shall meet all pertaining ASTM codes. Mortar to be Type "M" only proportioned Der FBC R601.1 and Mortar joints shall comply with FBC R601.2.1. Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...) Fill cell with Grout and (1) 45 bar vert. (typical). -Max. spacing shall not exceed 48" unless otherwise noted see foundation plan notes for spacing at openings 4" concrete slab with fibermesh OR O 0 Cx6" #10/10 WWM on 6 mil Visqueen over clean compacted termite treated fill — OVERHANGS AT I'—O" UNLESS OTHERWISE NOTED ON THIS SHEET ROOF PITCH AT -f:12 UNLESS OTHERWISE NOTED ON THIS SHEET TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER — ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL IN WRITING PRIOR TO STARTING CONSTRUCTION. Strap truss to wall using Simpson MGT with 5/8' dia. threaded rod with min 12" embedment into beam either wet set or in epoxy with (22) IOd nails into truss. Add blocking to truss leg per etail on this sheet T 4pical S ect[on at Front Porch Scale : 1/2" = I'—o" TA 2 N L90 L60 B B I L45 B I 'N I = 1 � W 130 B I \\V I I I m N � . i -- --- 2'- N W L6 BI I T/ \X// /ZI 12 I W = It I 7/�;T 2" BI ~ :q_1E SLOP cn B p oLU (n L N N Q U E <� �► B I L31 � 60 W U W O S� O'; �_ —0ND U O(� N - - a-� e I i - 1` E L I W I � Metal roofin and underla ment intstalled per Product Approval `n attachment diagram on roof plan. L22 BI BI $$1 I 1 � 22" x 54" Q Attic Access I SLOPE �{ with light — — — — — Brace Gal: U up tedwith 2" x 1 ' T ( P NT ' 8'-0" MAX. ' 8ft back r ( T 5 5 of top cho I I TI I I nails at ea 2" I 1 L�-------- I 1 I z 1 I I I I I 1 I I I I 1 I I ap I I I r------ I I I N N I I < z W I Simpson HETA I ° T hurlricane ancho at eac Ir ss N BI 1810 lb . uplift �` ` L9 B BI �' I Bl N 2'-2'1 I BI 60 BI � N Z Q fo LU Z Z W LH Q Q W U 0) N QL W l e end W� u 0 f" SYP 42 min. Z Z N ailed to bottom Z uJ oo M +' •ds using (2) 10 < } Lo M CA Q :h truss < 0 00 L Z 1 q LU m 7 0 ~ (U W v X v L U� ��� >L ALL TRUSS TO TRUSS CONNECTIONS BY Digitally signed TRUSS MANUFACTURER - ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR Daniel R.byDanielR. TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION Braden - CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO Braden Date:2021.11.22 PROVIDE FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO TRUSS CONSTRUCTION 11:50:21-05'00' SHEET NO: OF S. JOB NUMBER: 21-250 B • ' OWN\E� * pr�0��✓ AR 9770 ffu