APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
8217 MAIDENCANE PL, PORT ST LUCIE, FL 34986
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
REVISED PLAN -TO HAVE 50 AMP / 125V OUTLET
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CBC 1263072
BUSINESS NAME: PORT ST LUCIE PROPERTIES, INC
QUALIFIERS NAME: MARK MONTALTO
ADDRESS: 201 SW PSL BLVD SUITE 103
CITY: PORT ST LUCIE STATE: FL
PHONE (DAYTIME): 772-336-0050
OWNER/BUILDER INFORMATION:
NAME: MARK MONTALTO
ADDRESS: 201 SW PSL BLVD SUITE 103
CITY: PORT ST LUCIE
PHONE (DAYTIME: 772-336-0050
STATE: FL
ARCHITECT/ENGINEER INFORMATION:
NAME: PAUL WELCH JR
ADDRESS: 1984 SW BITMORE ST
CITY: PORT ST LUCIE
PHONE (DAYTIME): 772-785-9888
SLCCC: 9123109
Revised 06130117
STATE: FL
r
ST. LUCIE CO CERT. #: 31220
FAX:
FAX:
r Ax:
ZIP: 34984
ZIP: 34984
ZIP: 34984
BD ID� NJ G. HUTCHINSON
806 Delaware Ave.
Fort Pierce, FL 34950
December 21, 2021
Re: Zeitz Residence
8217 Maidencane Place
Fort Pierce, FL
To Whom It May Concern:
(772) 267-1399
benchmarkengineeringtc@gmail.com
k is
Please be advised of the revisions to the plan for the above referenced project as follows:
1) Revise plan to have 50amp / 125V outlet.
Thank you for your attention to this matter.
Submitted by: �J G' H V
=O o
* STATE O
•• gyp,. ��k�,
-.,, .c FL O ..
Bowdoin G. Hutch"' 6 0NA-��
1,11111111,,,,E
Reg. No 70878
w`
4
3
4
4
4
'a
$P E P$o
1201240V
21 a
BR 150A
MLO
, i
L 110, # 6, 2" C
(3)
i
# 6 GU GROUND TIED
"
- TO BUILDING STEEL,
�-- --
CWPAND DRIVEN
GROUND ROUND
NOTE: USEALL COPPER WIRE
—UG SERVICE BY FPL
(3) - # 1/0ALUM IN 2° C
OPTION a "B"
'ELECTRICAL .
SCPILE
ELECTRICAL LOAD CALCULATIONSNEC
}
1329 SQ. FT. AT 3 VOLT-AMPERES (GENERAL LIGHTING)
3967 ��JA
2
(2) 20AMPAPPLIANCE CIRCUITS
3000
3
LAUNDRY CIRCUIT
1500
4
DRYER
5000
w
5
RANGE
12000
6
WATER HEATER
4500
DISHWASHER
8
REFRIGERATOR
9
IRRIGATION PUMP OPTION
r39187
I SC.
TCAL
FIRST 10 K1V @ 1 % 10000
ELECTRICAL PLAN
REMAINDER ,. ��/� E 1 7 .
I'll'TOTAL: 21674.6
SCALE: " =: ' NC HEAT 20-Al 1 1300
TOTAL.: 31674.3 VA
31674.8 = 131.97S A PS `53 AMP SERVICE.
240
ELECTRICAL NOTES
1)ALL ELECTRICAL WORK SHAL BE IN ACCORDANCE WITH THE NEC (NFPA 70) 2017 EDITION.
2) A MINIMUM OF 75% OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE
HIGH-EFFACY LAMPS OR A MINIMUM OF 75% OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES
SHALL CONTAIN ONLY HIGH-EF>aACY LAMPS. (LOW VOLTAGE LIGHTING SHALL NOT BE REQUIRED
TO BE HIGH-EFFACY LAMPS)
3) RECESSED LIGHTING SHALL BE SEALED TO LIMIT AIR LEAKAGE BETWEEN CONDITIONED AND
UNCONDITIONED SPACES.
4)SMOKE DETECTORS TO BE 110V WY BATTERY BACK UP - ARC FAULT CIRCUIT
5) SMOKE DETECT ORS TO BE INTERCONNECTED SO THAT ONE SMOKE DETECTOR ACTIVATES ALL
SMOKE DETECTORS IN THE RESIDENCE
6) PROVIDE BRANCH CIRCUIT ARC -FAULT PROTECTION FOR ALL CIRCUITS SERVING: FAMILY ROOMS,
DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION
ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS PER FBC AND NEC REQUIREMENTS.
7) PROVIDE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL 125-VOLT, SINGLE-PHASE 15
AND 20 AMP CIRCUITS SRRVING: BATHROOMS, GARAGES, KITCHENS, ACCESORY BUILDINGS,
OUTDOORS, OR WITHIN 72" OF EDGE OF ANY SINK.
A) CARBON MENOXIDE DETECTORS TO BE INSTALLED WITHIN IV OF ALL BEDROOMS.
9) EXHAUST FANS TO BE VENTED THRU ROOF OR SOFFIT
10) PROVIDE TAMPER RESISTANT RECPTICLES PER NEC REQUIREMENTS.