Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: GEMINI IMPACT Street: GARAGE RIGHT City, State, Zip: FT. PIERCE, FL, Owner: Design Location: FL, Fort Pierce 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? New (From Plans) Detached 6. Conditioned floor area above grade (ft2) Conditioned floor area below grade (W) 7. Windows(155.2 sqft.) Description a. U-Factor: Sgl, U=1.02 SHGC: SHGC=0.27 b. U-Factor: Sgi, U=1.11 SHGC: SHGC=0.27 c. U-Factor: NIA SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description U-Factor:(AVG) NIA SHGC(AVG): NIA 9. Floor Types Insulation a. Slab -On -Grade Edge Insulation R= 0.0 b. NIA R= c. NIA R= Glass/Floor Area:0.084 1 2 Yes 1839 0 Area 121.88 ft2 33.33 ft2 ft2 Builder Name: WYNNE BUILDING CORP. Permit Office: ST. LUCIE COUNTY Permit Number: Jurisdiction: County: St. Lucie(Florida Climate Zone 2) 10. Wall Types(1763.8 sgft.) Insulation Area a. Concrete Block - Int Insul, ExteriorR=4.1 1507.80 ft2 b. Frame - Wood, Adjacent R=11.0 256.00 ft2 c. NIA R= ft2 d. NIA R= ft2 11. Ceiling Types(1839.0 sgft.) Insulation Area a. Roof Deck (Unvented) R=20.0 1839.00 ft2 b. NIA R= ft2 c. NIA R= ft2 12. Ducts, location & insulation level R ft2 a. a. Sup: GREAT/DINING, Ret: GREATIDININGj AF11&ttic b. c. 13. Cooling Systems kBtulhr Efficiency a. Central Unit 28A SEER:15.00 3.362 ft 0.270 14. Heating Systems kBtulhr Efficiency Area a. Electric Heat Pump 34.8 HSPF:8.50 NIA ft2 15. Hot Water Systems Area 1839.00 ft 2 a. Electric Cap: 40 gallons ft2 EF: 0.950 b. Conservation features ft2 None 16. Credits None Total Proposed Modified Loads: 51.12 Total Baseline Loads: 52.96 1 hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: 9-26-2021 I hereby certify that this building, as design compliance with the Florida Energy Code OWNER/ DATE: �� ��i.• Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: PASS - uomptiance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSIIRESNETI[CC 380, is not greater than 0.000 Qn for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 9/26/2021 2:36:01 PM EnergyGaugeE) USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: GEMINI IMPACT Addresslype: StreetAddress Building Type: User Bedrooms: 2 Lot#: - Owner. ConditionedArea: 1839 Block/SubDivision: Total Stories: 1 PlatBook: -- BuilderName: WYNNE BUILDING CORP. Worst Case: Yes Street: GARAGE RIGHT Permit Office: ST. LUCIE COUNTY RotateAngle: 180 County: St. Lucie Jurisdiction: Cross Ventilation: No City, State, Zip: FT. PIERCE, FamilyType: Detached Whole House Fan: No FL, New/Existing: New (From Plans) Terrain: Suburban YearConstruct: Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Dailytemp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range _FL, Fort Pierce FL-VERO-BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1839 14712 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _ 1 BEDROOM 343 2744 No 0 1 Yes Yes Yes _2 WIC 63 504 No 0 No Yes Yes _3 M. BATH 56 448 No 0 Yes Yes Yes _4 KITCHEN 172 1376 Yes 0 No Yes Yes _ 5 MASTER BEDROOM 2 256 2048 No 0 1 Yes Yes Yes _6 ENTRY 83 664 No 0 Yes Yes Yes _7 LAUNDRY 42 336 No 0 Yes Yes Yes _8 GREAT/DINING 568 4544 No 0 Yes Yes Yes _9 CLOSET 56 448 No 0 No Yes Yes _10 BATH 2 48 384 No 0 Yes Yes Yes _11 POWDER 42 336 No 0 No Yes Yes 12 SITTING ROOM 110 880 No 0 Yes Yes Yes FLOORS (Total Exposed Area = 1839 sq.ft.) # FloorType Space Exposed Perim PerimeterR-Value Area U-Factor Joist R-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Ins BEDROOM 43 0 343 ft 0.473 - 0.00 1.00 0.00 _2 Slab -On -Grade Edge Ins WIC 1 0 63ft 0.473 - 0.00 1.00 0.00 _ 3 Slab -On -Grade Edge Ins M. BATH 8 0 56 ft 0.473 - 0.00 1.00 0.00 _4 Slab -On -Grade Edge Ins KITCHEN 1 0 172ft 0.473 - 0.00 1.00 0.00 _5 Slab -On -Grade Edge Ins MASTER BEDROOM 2 51 0 256 ft 0.473 - 0.00 1.00 0.00 _6 Slab -On -Grade Edge Ins ENTRY 7 0 83ft 0.473 - 0.00 1.00 0.00 _7 Slab -On -Grade Edge Ins LAUNDRY 6 0 42ft 0.473 - 0.00 1.00 0.00 _8 Slab -On -Grade Edge Ins GREAT/DINING 39 0 568ft 0.473 - 0.00 1.00 0.00 _9 Slab -On -Grade Edge Ins CLOSET 1 0 56 it 0.473 - 0.00 1.00 0.00 _10 Slab -On -Grade Edge Ins BATH 8 0 48ft 0.473 - 0.00 1.00 0.00 _ 11 Slab -On -Grade Edge Ins POWDER 1 0 42 ft 0.473 - 0.00 1.00 0.00 12 Slab -On -Grade Edge Ins SITTING ROOM 22 0 110 ft 0.473 - 0.00 1.00 0.00 926/20212:36:01 PM EnergyGauge®USA 7.0.00- FlaRes202O FBC 7th Edition(2020) Compliant Software Paget FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1938 ft' Oft Light N 0.6 No 0.5 No 20 18.43 ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Fullattic Unvented 0 1839 ft' N N CEILING (Total Exposed Area = 1839 sq.ft.) # Ceiling Type Space R-Value Ins.Type Area U-Factor Framing Frac. Truss Type _ 1 UnderAttic(Unvented) BEDROOM 0.0 Blown 343.Of 2 0.061 0.10 Wood _2 UnderAftic(Unvented) WIC 0.0 Blown 63.0f2 0.061 0.10 Wood _3 UnderAttic(Unvented) M. BATH 0.0 Blown 56.Oft- 0.061 0.10 Wood _4 UnderAttic(Unvented) KITCHEN 0.0 Blown 172.0ft' 0.061 0.10 Wood _ 5 UnderAttic(Unvented) MASTER BEDROOM 2 0.0 Blown 256.0ft 0.061 0.10 Wood _6 UnderAttic(Unvented) ENTRY 0.0 Blown 83.0ft- 0.061 0.10 Wood _7 UnderAttic(Unvented) LAUNDRY 0.0 Blown 42.OW 0.061 0.10 Wood _8 UnderAftic(Unvented) GREAT/DINING 0.0 Blown 568.0ft2 0.061 0.10 Wood _9 UnderAttic(Unvented) CLOSET2 0.0 Blown 56.Oft- 0.061 0.10 Wood _ 10 UnderAttic(Unvented) BATH 2 0.0 Blown 48.01t' 0.061 0.10 Wood _11 UnderAttic(Unvented) POWDER 0.0 Blown 42.01? 0.061 0.10 Wood 12 UnderAttc(Unvented) SITTING ROOM 0.0 Blown 110.Oft' 0.061 0.10 Wood WALLS (Total Exposed Area = 1764 sq.ft.) Note: Firstwall orientation below is as entered. Actual orientation is modified by the rotate angle (180 degrees) as shown in the "Project" section on page 1. / Adjacent Cavity Width Height Area U- Sheath F". Solar Below �/ # Omt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade _1 S=>N Exterior Conc.BIk-Intlns BEDROOM 4.1 29.0 0 8.0 0 232.0 0.149 0 0 0.30 0% _2 W=>E Exterior Conc.BIk-Intlns BEDROOM 4.1 14.0 0 8.0 0 112.0 0.149 0 0 0.30 0% _3 S=>N Exterior Cone. Silk - Int Ins M. BATH 4.1 8.0 0 8.0 0 64.0 0.149 0 0 0.30 0% _4 N=>S Exterior Cone. Bilk - Int Ins MASTER BEDROOM 2 4.1 24.0 0 8.0 0 192.0 0.149 0 0 0.30 0% _5 E=>W Exterior Cone. Bik- Int Ins MASTER BEDROOM 2 4.1 13.0 0 8.0 0 104.0 0.149 0 0 0.30 0% _6 S=>N Exterior Cone. Blk- Int Ins MASTER BEDROOM 2 4.1 14.0 0 8.0 0 112.0 0.149 0 0 0.30 0% _7 E=>W Exterior Cone. Blk- Int Ins ENTRY 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.30 0% _ 8 S=>N Exterior Cone. Blk - Int Ins ENTRY 4.1 1.0 0 8.0 0 8.0 0.149 0 0 0.30 0% _ 9 S=>N Exterior Cone. Blk - Int Ins LAUNDRY 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.30 0% _ 10 N=>S Exterior Cone. Blk - Int Ins GREAT/DINING 4.1 30.0 0 8.0 11 267.5 0.149 0 0 0.30 0% _11 W=>E Exterior Cone. Blk -Int ins GREAT/DINING 4.1 9.0 0 8.0 11 80.3 0.149 0 0 0.30 0% _ 12 N=>S Exterior Cone. Blk - Int Ins BATH 2 4.1 8.0 0 8.0 0 64.0 0.149 0 0 0.30 0% _ 13 N=>S Exterior Cone. Blk - Int Ins SITTING ROOM 4.1 10.0 0 8.0 0 80.0 0.149 0 0 0.30 0% 14 S=>N Exterior Cone. Blk - Int ins SITTING ROOM 4.1 1.0 0 8.0 0 8.0 0.149 0 0 0.30 0% _ 15 W=>E Exterior Cone. BIk- Int Ins SITTING ROOM 4.1 11.0 0 8.0 0 88.0 0.149 0 0 0.30 0% 16 N=>S Garage Frame -Wood KITCHEN 11.0 32.0 0 8.0 0 256.0 0.092 0.23 0.30 0% DOORS (Total Exposed Area = 20 sq.ft.) / Width Height V# Omt Adjacent To DoorType Space Storms U-Value Ft In Ft In Area 1 E=>W Insulated ENTRY None 0.32 3.00 0 6.00 8 20.Oft- 9126/20212:36,01 PM EnergyGauge®USA 7.0.00- FlaRes2020 FBC 7th Edition(2020) Compliant Software Page FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 155 sq.ft.) / Wall -Overhang- / # Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation InteriorShade Screening -1 W=>E 2 Metal Low-E Single Yes 1.02 027 Y N 32.4fP 1.0 it 0 in 1.0 ft4 in Drapes/blinds EMerior5O% _2 S=>N 3 Metal Low-ESingle Yes 1.02 0.27 Y N 6.9112 1.0 It 0 in 1.0 it 4 in None None _ 3 E=>W 5 Metal Low-ESingle Yes 1.02 0.27 Y N 32AW 1.0 it 0 in 1.0 it 4 in None None _4 N=>S 10 Metal Low-ESingle Yes 1.02 0.27 Y N 25.Oft 1.0 ft0 in 1.0 it in None None _5 W=>E 11 Metal Low-ESingle Yes 1.11 0.27 Y N 33.3ft2 12.0 it in 1.0 It in None None _6 N=>S 12 Metal Low-ESingle Yes 1.02 0.27 Y N 6.911 1.0 It in 1.0ft4 in None None 7 W=>E 15 Metal Low-ESingle Yes 1.02 0.27 Y N 18.4ft2 1.0 ft 0 in 1.0 It 4 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00025 1226 67.26 12628 0.0902 5.0 All GARAGE # FloorArea Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 320 ft2 320 ft2 32 ft 8 it 11 MASS # Mass Type Area Thickness Furniture Fraction Space _ 1 Default(8 lbs/sq.ft.) 0 ft2 0 ft 0.30 BEDROOM _2 Default(6 lbs/sq.fL) 0ft2 Oft 0.30 WIC _3 Default(8 lbs/sq.ft) 0 ft, Oft 0.30 M. BATH _4 Default(8 lbs/sq.fL) Oft, Oft 0.30 KITCHEN _5 Defauft(8lbs/sq.ft.) 0 ft2 Oft 0.30 MASTER BEDROOM 2 _ 6 Default(8 lbs/sq.ft.) 0 ft2 Oft 0.30 ENTRY _7 Default(8 lbs/sq.ft.) Oft2 Oft 0.30 LAUNDRY _8 Default(8 lbs/sq.ft.) Oft' Oft 0.30 GREAT/DINING ' _ 9 Default(8 lbs/sq.ft.) 0 f12 Oft 0.30 CLOSET 2 _ 10 Default(8 lbs/sq.ft.) 0 ft2 Oft 0.30 BATH 2 _ 11 Default(ii lbs/sq.ft.) 0 ft2 Oft 0.30 POWDER 12 Default(8 lbs/sq.ft.) 0ft2 Oft 0.30 SITTING ROOM HEATING SYSTEM # SystemType Subtype/Speed AHRI # Efficiency Capacity-GeothermalHeatPump- Ducts Block kBtu/hr Entry Power Volt Current -1 Electric Heat Pump Split/Single HSPF: 8.50 34.8 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # SystemType Subtype/Speed AHRI# Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm -1 CentmlUnit Split/Single SEER:15.0 28.4 852 0.85 sys#1 1 9/26/20212:36:01 PM EnergyGauge®USA 7.0.00- FlaRes202O FBC 7th Edition(2020) Compliant Software Page4 FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # SystemType Subtype Location EF(UEF) Cap Use SetPnt FodureFlow Pipe Ins. Pipe length 1 Electric None Garage 0.95(—) 40.00gal 61 gal 120 deg Standard None 96 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS Supply— —Retum-- Air CFM 25 CFM 25 HVAC # VDuct # Location R-Value Area Location R-Value Area LeakageType Handler TOT OUT ON RLF Heat Cool 1 GREAT/DINING 6.0 115 ft' GREAT/DINING 6.0 40 ft' DefaultLeakage Attic (Default) (Default) 1 1 TEMPERATURES ProgramableThernostat: N Ceiling Fans: N Cooling []Jan []Feb []Mar []Apr May ((]Jun [(]Jul [(]Aug [(]Sep (]Oct []Nov []Dec Heating [(] Jan [(] Feb ((] Mar [ ] Apr [ ] May [ ] Jun [I Jul [] Aug [ ] Sep [ ] Oct [JC] Nov ((] Dec Venting []Jan []Feb [(]Mar [(]Apr []May []Jun []Jul []Aug []Sep [(]Oct [(]Nov []Dec Schedule: HERS 2006 Reference Hours VThermostat �/ ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 _Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _ Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _ Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 _ Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 9126t20212:36:01 PM EnergyGauge®USA 7.0.00- FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA" Project Name: GEMINI IMPACT Builder Name: WYNNE BUILDING CORP. Street: GARAGE RIGHT Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner. Jurisdiction: U Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _ U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall beinstalled inthe building envelope. Air-permeableinsulationshall requirements The exteriortherrnal envelope contains a continuous airbarrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exteriortherrnal envelope insulation forframed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation andcantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawlspacewalls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class l vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspacewalls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrowcevities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garageseparation Air sealing shall be provided between the garage and conditionedspaces. Recessedlighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and I rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exteriorwalls adjacent to showers Exteriorwalls adjacent to showers and tubs shall onexteriorwall and tubs shall separate them from the showers and tubs. beinsulated. Electrical/phonebox The air barriershall be installed behind electrical or onexteriorwalls communication boxesorair-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a mannerthat is recommended by the manufacturer. Caulking or otheradhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls orceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 9126/20212:36:01 PM EnergyGauge®USA 7.0- FlaRes2020 FBC 7th Edition(2020) Compliant Software Pagel FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. GARAGE RIGHT,FT. PIERCE,FL, 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 2 5. Is this a worst case? Yes 6. Conditioned floor area above grade (ft') 1839 Conditioned floor area below grade (ft2) 0 7. Windows" Description Area a. U-Factor: Sgl, U=1.02 121.88 fC SHGC: SHGC=027 b. U-Factor: Sgl, U=1.11 33.33 ft2 SHGC: SHGC=0.27 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 3.362 ft Area Weighted Average SHGC: 0.270 8. Skylights Description Area U-Factof:(AVG) N/A N/Aft' SHGC(AVG): N/A 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R= 0.0 1839.00 ft2 b. N/A R= ft2 c. N/A R= ft2 10. Wall Types(1763.8 sqft.) Insulation Area a. Concrete Block - Int Insul, ExtedorR=4.1 1507.80 It b. Frame - Wood, Adjacent R=11.0 256.00 ft2 c. N/A R= ft2 d. N/A R= ft2 11. Ceiling Types(1839.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 1839.00 ft2 b. N/A R= ft2 c. N/A R= ft2 12. Ducts, location & insulation level R ft2 a. a. Sup: GREAT/DINING, Ret: GREAT/DININC$AH18ttic b. C. 13. Cooling Systems kBtu/hr Efficiency a. Central Unit 28.4 SEER:15.00 14. Heating Systems kBtu/hr Efficiency a. Electric Heat Pump 34.8 HSPF:8.50 15. Hot Water Systems a. Electric Cap: 40 gallons EF: 0.950 b. Conservation features None 16. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: �- Date: Address` of New Home: GARAGE RIGHT City/FL Zip: FT. PIERC\E,,FL, 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/26/20212:36:01 PM EnergyGauge®USA 7.0.00- FlaRes2020 FBC 7th Edition(2020) Compliant Software Pagel oft + wrightsoft- Project Summary n te1 Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 PInre: 772-466-6799 Fax 712-4666796 Emil: OUICKCALCS@AOL.COM For: THE GEMINI GARAGE RIGHT WYNNE DEV., FT. PIERCE, FL Notes: Weather: Winter Design Conditions Outside db Inside db Design TD Fort Pierce, FL, US Summer Design Conditions 42 °F Outside db 70 °F Inside db 28 °F DesignTD Daily range Relative humidity Moisture difference Heating Summary Structure 22452 Btuh Duds 3668 Btuh Central vent (0 cfim) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipmentload 26121 Btuh Infiltration Method Construction quality Fireplaces Simplified Average He Goolin Area ftz 1839 1839 Volume (1N) 15606 15606 Airchangeslhour 0.38 020 EquivAVF (cfin) 99 52 Heating Equipment Summary Make Carrier Trade COMFORT15 HP Model 25HBC530AP0300 AHRI ref 0 Efficiency 8.5 HSPF Heating input Heating output 28200 Btuh@47°F Temperature rise 27 °F Actual airflow 947 dm Airflowfactor 0.036 dm/Btuh Static pressure 0.50 in H2O Space thermostat Capacity balance point = 39 OF Backup: Input=7kW, Output= 23009 Btuh, 100 AFUE 90 OF 75 OF 15 OF L 50 % 61 grfib Sensible Cooling Equipment Load Sizing Structure 17174 Btuh Duds 2542 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturers data n Rate/swing multiplier 0.95 Equipment sensible load 18730 Btuh Latent Cooling Equipment Load Sizing Structure 2173 Btuh Ducts 2141 Btuh Central vent (0 dm) 0 Btuh (none) Equipment latent load 4314 Btuh Equipment Total Load Sen+Lat) 23044 Btuh Req. total capacity at 0.70 SHR 22 ton Cooling Equipment Summary Make Carder Trade COMFORT15 HP Cond 25HBC530AP0300 Coil FX4DNB031L AHRI ref 0 Efficency 12.5 EER,15 SEER Sensible000ling 19880 Btuh Latent000ling 8520 Btuh Total cooling 28400 Btuh Actual airflow 947 clam Airflowfador 0.048 dm/Btiih Static pressure 0.50 in H2O Load sensible heat ratio 0.82 Calculations approved byACCAto meet all requirements of Manual J 8th Ed wrLsofi^ 2021-Sep-2911:09:34 e5RgltSute®Lkiv al 202121.0A8 �1108101 Pagel ..G.l�...�ftWAgWYNNE-GEWNFGARAGEPoGHT-BHOMEnp Calc=M18 FmrtDocrla wN F 1 wrightsoft' Right-J® Worksheet Job: Entire House By By. QUICK CALCS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Prore: 772466-6799 Fax 772-4666796 Emil: OUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 Sposedwall 214.0 It 45.0 It 3 Room height 8S ft d 8A ft heaVwol 4 Room dimensions 1.0 x 360A It 5 Room area 1839.0 IF 360.0 1F Ty CortLvcfion U-value Or HTM Area (fl Load Area (T) Load number (BWh4F-`g (BWhMn or perimeter (ft) (BWh) or perimeter (ft) (SWh) Heat Cool Gros NIPJS Heat Cod Gros NfPS Heat Cool 6 V"13A-4ocs 0.143 In4.00 2.55 472 465 1862 1184 248 248 993 631 1Acian 1270 In 351% 3477 7 0 247 241 0 0 0 0 13A4ar 0.143 a 4.00 2b5 152 98 394 250 0 0 0 0 1Aclom 1270 a 3556 9729 33 4 1162 2853 0 0 0 0 11 11DO 0390 a 1092 1131 21 21 229 238 0 0 0 0 W 13A41ors 0.143 a 4A0 255 640 608 2434 1548 0 0 0 0 1Ac1om 1270 s 35-% 34.77 7 14 247 241 0 0 0 0 4A52om 0.770 a 2156 1931 25 50 543 497 0 0 0 0 13A.4ors 0.143 w 4.00 2.55 296 210 843 536 112 79 318 202 1A.c1om 1270 w 3556 5525 33 4 1162 1806 33 2 1162 1806 4A5-2om 0770 w 21.56 44.72 19 3 407 845 0 0 0 0 4A5-2oW 0.470 w 13.16 13.55 34 68 447 461 0 0 0 0 P 12C-OGN 0.097 2.55 128 232 232 591 298 0 0 0 0 C 16X19-0md 0.408 - 1.59 1.49 1839 1839 2916 2733 360 360 571 535 F 22A4pl 098.9 - 27.S9 0.00 1839 214 5926 0 360 45 1246 0 6 c)AED e=rsion 597 592 Ernelcpe losskpin 19411 14316 4290 3766 12 a) Wfiltation 3042 858 702 198 b) Room ventilation 0 0 0 0 13 Irltxralgains O=pants@ 230 0 0 0 0 Appliances0ther 2000 0 Subt)tal(Ilnes6t)13) 22452 17174 4992 3963 Lea; extanlal load 0 0 0 0 Lmkansfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 22452 17174 4992 3963 15 Dudksds 16% 15% 3668 2542 16% 15% 816 587 Total room load 26121 19716 1 1 5807 4550 Airrequiled(dim) 947 947 211 219 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed 2021 Sep-291199:34 c MgHSLiL@ Umerael 202121.0A8 RSLJO8101 Page 1 ...6oft HJAQWY NE-GEMINFGARAGERIGW-BHOMEap Calc=NW FrortDoorfaces:N P�+wrightsoft- Right-J® Worksheet Job: Entire House By. By. QUICK CALCS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Pima: 772-466-6799 F=772466-6796 Email OUN7(CALCS@AOL.COM 1 Room name WIC MBATH 2 Exposedwall 0 ft 8A It 3 Room height 8.0 ft heakool 8D ft heat/mcl 4 Room dimensions 7.0 x 9.0 ft 7.0 x 8.0 It 5 Room area 63D W 56A ft Ty Conshudion U-value Or HTM Area (ft2) Load Area (w) Load number (BWhAF-'n (BhihAn or pedmebr M (BWh) or perimeter (ft) (BWh) Hear Cod Gras NIPS Hear Cool Cron NRS Heat Cool 6 13A4ocs 0.143 n 4.00 2.55 0 0 0 0 64 57 228 145 t—C 1AcIom 1270 n 3556 34.77 0 0 0 0 7 0 247 241 13A4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1A-dw 1270 a 35M 8729 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 1131 0 0 0 0 0 0 0 0 13A4ocs 0.143 s 4A0 2.55 0 0 0 0 0 0 0 0 1Ac1am 1270 s 35-% 34.77 0 0 0 0 0 0 0 0 4A5-20m 0.770 s 21M 1931 0 0 0 0 0 0 0 0 13A4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1As1om 1270 w 35.b6 5525 0 0 0 0 0 0 0 0 4AF-20m 0770 w 21.56 44.72 0 0 0 0 0 0 0 0 4A5-20W 0.470 w 13.16 13.55 0 0 0 0 0 0 0 0 P 12G09N OA91 - 2.55 128 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 - 1.59 1.49 63 63 100 94 56 56 89 83 F MA-tlx 05w 27.69 0.00 63 0 0 0 56 8 222 0 6 c)AEDe=rsion -9 48 Envelope losstgain 100 85 785 422 12 a) 11fiMation 0 0 125 35 b) Roomlentiladon 1 0 0 0 0 13 Inta nal gain Omtpants@ 230 0 0 0 0 Appliarcesb9ner 0 0 Subtotal (lines 6 so 13) 100 85 910 457 Less exbmal load 0 0 0 0 Lestransler 0 0 0 0 Redishibuton 0 0 0 0 14 Subtotal 100 85 910 457 15 Dud loads 16% 15% 16 13 16% 15% 149 68 Total roan bad 116 97 1059 524 Air required(dm) 4 5 38 25 Calculations approved bvACCAto meet all reouirements of Manual J 8th Ed ,� 2021Sep-2911:09:34 PigttStite&Lkiwml202l 2l.O.O8 RSLI08101 Page 2 ...6 tHVAMWYNNE-GEMINFGARAGERIGHT43HOME.np Calc=M18 Fmrt Doorfaces N ►}� wr4itsow Right-J® Worksheet '°b, Entire House Dom` By. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Pore: 772-4666799 Fax 772-4606796 Emil: QUICKCALCS@AOL.COM 1 Room name IOTCHEN MASTER BEDROOM2 2 Exposed wall 8.0 ft 51.0 2 3 Room height 8.0 ft heat/wol 8.0 t heatbod 4 Row dimensom 1.0 x 172.0 t 1.0 x 256.0 ft 5 Room area 172.0 ft 256.0 W Ty Conshumon U-value or HTM Area (ftF) Load Area (ftl Load number (BWhWL'g (BWhR cr perimeter (ft) (Btuh) or penmekr (ft) (Bluh) Heat Cod Gross NIPIS Heat Cod Gros NIPS Heat Cool 6 W 13A4= 0.143 n 4A0 255 0 0 0 0 112 112 448 295 �C 1A-d= 12M In 3556 34.77 0 0 0 0 0 0 0 0 13A4= 0.143 a 4.00 255 0 0 0 0 104 71 286 182 1Aciam 1270 a 3556 8729 0 0 0 0 33 2 1162 2853 11 11D0 0390 a 10d)2 1131 0 0 0 0 0 0 0 0 VyL �CG 13A4= 0.143 5 4.00 255 0 0 0 0 192 192 769 489 1Ad= 1270 s 35.56 34n 0 0 0 0 0 0 0 0 4A6-2am 0.770 s 2156 1931 0 0 0 0 0 0 0 0 13A4= 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1270 w 3556 5525 0 0 0 0 0 0 0 0 4A -2= 0.770 w 2156 44.72 0 0 0 0 0 0 0 0 4A5-20W 0.470 w 13.16 13.55 0 0 0 0 0 0 0 0 P 12C-09N 0.091 - 255 128 64 64 163 82 0 0 0 0 C 16X19-0md OA08 - 159 1.49 172 172 273 256 256 256 406 380 F 22A-I 0.9O9 - 27.69 0.00 172 8 222 0 256 51 1412 0 6 c)AED e=rsan -222 -205 Emelope losdgain 657 115 4483 3984 12 a) bfiltrabon 0 0 795 224 b) Roomlenfilafion 0 0 0 0 13 Intemal gains: O—Pam@ 230 0 0 0 0 Applwoesbfiler 2000 0 Subbbl(0nes6b13) 657 2115 1 5279 4208 Lessexbmalload 0 0 1 0 0 Lew transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subblal 657 2115 5279 4208 15 Ductbads 16% .1 107 313 16% 15% 862 623 Total room load 765 2429 6141 4831 Airre9uired(dm) 28 117 223 232 Calculations approved bvACCAto meet all reauirements of Manual J 8th Ed _040- ngf1C" ggllSure®Unee l 202121.0.08 RSU08101 2021Sep-2911:09:34 Aftk Page 3 _isoR HJAC\WYNNE-GEMN4GARAGE RIGHT-B HOMEnp CaIc=M18 Fmrt Doorfarns: IN wrightsoft Right-M) Worksheet J0k Entire House By By. QUICK CALCS, INC. 317 ST. LUCIE LN., F .. PIERCE, FL 34946 Phor :772-0fi6-6799 F=772-466E796 Email: QUICKCALCS@AOL.COM 1 Room name ENTRY LAUNDRY 2 E osed wall 20.0 It 13.0 It 3 Room height 8.0 It heatlmd 8.0 It heatlmol 4 Room dimereorls 6.0 x 14.0 It 7.0 x 6.0 It 5 Room area 84D IF 42A IF Ty Consuclim U-value Or HTM Area (iF) Load Area (F) Load number (BWh4F-°Fj (BWh4F) or perimeter (ft) (BWh) a perimeter (it) (BWh) Heat Cod G. NIPS Heat Cod Gros N,P5 Heat Cool 6 W 13A-4os 0.143 n 4D0 2.55 0 0 0 0 48 48 192 122 �G 1Aclam 1270 n 35.56 34.77 0 0 0 0 0 0 0 0 13AA= 0.143 a 4DO 2.55 48 27 108 69 0 0 0 0 1AcIorn 1270 a 3556 8729 0 0 0 0 0 0 0 0 11 11D0 0" a 10.92 1131 21 21 229 238 0 0 0 0 Yy 13A4as 0.143 a 4.00 2M 0 0 0 0 0 0 0 0 1A-d m 1270 a 3556 3477 0 0 0 0 0 0 0 0 LI—CG 4AS-Zom 0.770 s 2156 1931 0 0 0 0 0 0 0 0 1A-c1=Aocs w 4.56 0 0 0 0 0 0 0 0 13A om 1270 1270 w 3556 525 5525 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21.56 44.72 0 0 0 0 0 0 0 0 4A5-2oW 0.470 w 13.16 1355 0 0 0 0 0 0 0 0 P 12C-Ow OD91 - 2.55 128 112 112 2B5 144 56 56 143 72 C 16X19-0md 0-408 - is 1.49 84 84 133 125 42 42 67 62 F 22ArtpI Oum - ZT69 0.00 84 20 554 0 42 13 360 0 6 c)AEDexarson -57 -27 Enwelope loss(gain 1310 518 761 230 12 a) Melton 94 26 94 26 b) Roorrl"Nabon 0 0 0 0 13 hierral gairs: O=pants@ 230 0 0 0 0 Applianoesb1her 0 0 Sublotel(lines64113) 1403 544 855 256 Les expinal load 0 0 0 0 Lestrarder 0 0 0 0 Redistributon 0 0 0 0 14 SubBdal 14M w855 2% 15 Duct= 16% 15% 229 81 W/ 15% 140 38 Tolal room load 16N 995 294 Airrequired(Z) 59 1 30 36 14 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. G ->•{+- wrighLsoR— 2021-Sep-2911:09:34 cw Rigrl-SuGHT-iaHOME.021 Calc MJ81 Front Page ...+soft HVAC�WYNNE-GEMIN4GARAGE RIGHr43 HOME.np CaIc=MIB Frw[Deortaoes N wrightsoft• Right-JO Worksheet Boa Entire House Date: QUICK CALCS, INC. BY 317 ST. LUCIE LN.. FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-066-6796 Emil: QUICKrALCS@AOL.COM 1 Room name GREAT/DINING CLOSE-1-2 2 E1rpcsedvall 33.0 It 0 It 3 Room height 89 It heaUmoi 9A ft heatknol 4 Room dimensions 1.0 x 468.0 It 7.0 x 8.0 it 5 Roomarea 468.0 1F 56.0 T Ty Cons idon U-wilue Or HTM Area (fF) Load Arm (fF) Load rwmber (BwhAF-`F) or perimeter (ft) (BWh) a penmeter (in (Bluh) Heat Cool Gross NIPS Heat Cool Gros NIPS Heat Cad 6 W 13A-4as 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 �C 1Atlw 1270 n 3556 34-77 0 0 0 0 0 0 0 0 13A-4= 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 tl 1Ac1= 1270 a 3556 8729 0 0 0 0 0 0 0 0 11 11130 0390 a 10.92 1131 0 0 0 0 0 0 0 0 I`—CG 13A4o s 0.143 s 4A0 2.55 223 197 790 502 0 0 0 0 1A-d= 1270 s 3556 34.77 0 0 0 0 0 0 0 0 4A5-2an 0770 s 2156 1931 25 25 543 487 0 0 0 0 13A4 w 4.00 5 71 37 14 95 0 0 0 0 1A,clm 12M 1270 w 3556 552525 0 0 0 0 0 0 0 0 4A5-2an 0.770 w 2156 44.72 0 0 0 0 0 0 0 0 4A5-2DW 0.470 w 13.16 1355 34 34 447 461 0 0 0 0 P 12C-0av OD91 - 255 128 0 0 0 0 0 0 0 0 C 16X19-0md OAO8 - 159 1.49 468 468 742 695 56 56 89 83 F 22A-V 0989 - 2769 OAO 468 33 914 0 56 0 0 0 6 c)AED ettursion 446 -8 Envelope m4gan 3586 2686 89 75 12 a) hfiftlion 573 161 0 0 b) Room verNlafion 0 0 0 0 13 htemalgaim Ooalpants@ 230 0 0 0 0 Appliaveafoltler 0 0 Subttal(lines(Stoi3) 4158 2847 89 75 Lesexb5m iload 0 0 0 0 Les transfer 0 0 0 0 Redishibufion 0 0 0 0 14 Subtotal 4158 2847 89 75 15 Ductbads 16% 15% 679 421 16Y 15k 15 11 Total room load 4838 3269 103 86 Air required (dm) 175 157 4 4 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed ,C -'T !�! 2021-SeP2911:0934 C�A Ri GEPJGH-8 HOa2021 Calc IRSU08707 Page _.Eofl HVAC\WYNNE-GEMINFGARAGE RIGFIr-B NOMEnp CaIc=M18 Frort Doorfares N I}Fwrightsoft' Right-JO Worksheet Job: Entire House By By. QUICK CALCS, INC. 317 ST. LUGE LN., FL PIERCE, FL 34946 Prone: 772-466-6799 Fax 772-466-6796 Emil: OUrKCALCS@AOL.COM 1 Roan name BATH 2 POWDER 2 Dpowdvall 8.0 It 0 It 3 Rann height 9.4 ft heabbod 9.4 ft heWmd 4 Roam dimensions 6.0 x 8A it 7.0 x 6A ft 5 Room area 48.0 1F 42.0 fF Ty Gonsbxlion U-value Or 1 HTM Area IT) Load Area (M Load number (BWh4F-°F) i (BtjW or perimeter (ft) (BWh) or perimeter (f) (BWh) Heat Cod Gros NIPIS Heat Cod Gross NIPS Heat Cool 6 t—G 13A M 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 13A-4= 127o 0.143 n a 3556 4.00 34.77 255 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1A-dw 1270 a 3556 8729 0 0 0 0 0 0 0 0 11 11DO 0.390 a 1022 1131 0 0 0 0 0 0 0 0 W 13AAos 0.143 s 4A0 255 75 68 273 174 0 0 0 0 {--G tAclan 1270 s 3556 34.77 7 7 247 241 0 0 0 0 I---G 4A5,2om 0.770 s 21% 1931 0 0 0 0 0 0 0 0 13AA= 0.143 w 4-00 255 0 0 0 0 0 0 0 0 1Aclan 1270 w 3556 5525 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21M 44.72 0 0 0 0 0 0 0 0 4A5.2md 0.470 w 13.16 1355 0 0 0 0 0 0 0 0 P 12C-09N 0A91 - 255 128 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 - 159 1.49 48 48 76 71 42 42 67 62 F 22A-tA 0.989 - 27.69 0.00 48 8 222 0 42 0 0 0 6 c)AEDe=rsim -50 -6 Envelope loss/gain 818 436 67 56 12 a) Infiltration 147 41 0 0 b) Rcomventlafim 0 0 0 0 13 Internal gam: O=pants@ 230 0 0 0 0 Appliancesb1her 0 0 SubWlal(lines6b13) 964 477 67 56 Les external load 0 0 0 0 Les transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtalal 964 477 67 56 15 Ductic s 16% 15% 158 71 16% 15% 11 8 Total mom load 1 1 1122 548 77 65 Airrequired(dm) 41 26 3 3 Calculabons approved byACCAto meet all requirements of Manual J 8th Ed. -40- 2021-Sep-2911:09:34 ASK Right-Sute®lhiversa1202121.0.08RSW8101 Page ...tsoft HVAQWYNNE-GEMIN4GARAGE RIGHT-SHOMEnp Calc=MIB Frod Doorfaces: N wrightsoft' Right-J@Worksheet Job: Entire House By. By. QUICK CALCS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Rene: 772-066-6799 Fax 772-466-6796 Email: QUICKC4LCS@AOL.COM 1 Room name SrrTWGROGM 2 Exposed wall 28.0 R 3 Room height 9.4 11 heatbool 4 Room dimensions 12.0 x 16.0 A 5 Roan area 192.0 fF Ty Construction U-due Or HTM Area (fF) Load Area Load number (BWhW-'o (BWhA[) or perimeter (it) (BWh) or perimeter Heat Cool Gros NIPS Heat Cool G. N/PS Heat Cool 6 13AAors 0.143 n 4.00 2,55 0 0 0 0 IA -clam 1270 n 3556 34.77 0 0 0 0 13AA= 0.143 a 4.00 2.55 0 0 0 0 1A-dom 1270 a 3556 8729 0 0 0 0 it 11DO 0390 a 1092 1131 0 0 0 0 13AA= 0.143 s 4A0 2.55 150 150 602 383 1Aclom 1270 s 35M 3477 0 0 0 0 L�CG 4AS2an 0.770 s 2156 1931 0 0 0 0 1A-do6 w 4A0 113 94 370 230 1A-clam 1270 1270 w 35.56 525 5525 0 0 0 0 4A5.2an 0.770 w 2156 44.72 19 2 407 845 4A -25W 0.470 w 13.16 13M 0 0 0 0 P 12C-Osv OA91 - 21% 128 0 0 0 0 C 16X19-0md OA08 - 1B9 1A9 192 192 304 285 F 22A-QY 0939 - 27.69 ODO 192 28 775 0 6 c)AED emlrsion 192 Envelope lossigain 2465 1944 12 a) Infiltration 513 145 b) Room ventilation 0 0 13 Internal ga. O=pants@ 230 0 0 Applianoeslollta 0 Sublotal(lines6bi3) 2979 2089 Lese)dsmal load 0 0 Less tianster 0 0 Redistribution 0 0 14 Subtotal 2979 2089 15 Ductloads 16% 15% 487 309 Total room load 3465 2398 Airrequired (rim) 126 115 Calcula5ons approved bvACCA to meet all requirements of Manual 18th Ed �i• wR 2021-Sep-29110934 VAQ '^^ RAGERGH LYivHOMErtp CaO.OBRSUFront Page -.tsoft HVAQWYNNE-GEMINFGARAGE RIGHr-B HOMEnp CaIc=MI6 Frort Doortaces N * wrightsoft" Duct System Summary Entire House QUICK CALCS, INC. 317ST.LUCIE LN.,FT. PIERCE, FL 34946 Phore: 772466-6799 Fax7724666796 Emfl:QUrKGALCS@AOL.COM For. Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) THE GEMINI GARAGE RIGHT WYNNE DEV., FT. PIERCE, FL Heating 0.50 in H2O 0 in H2O 0.50 in H2O 02.50 /0250 in H2O 0.285 in/10011 947 cim 176 Supply Branch Detail Table Job: Date: By. Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0250 /0250 in H2O 0285 in1100ft 947 cftn Name Design (Btuh) Htg (clm) Clg (ctm) Design FR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 1122 41 26 0.368 4.0 Ox0 VIFx 21.0 115.0 stl CLOSET2 c 86 4 4 0.363 4.0 Ox0 VIFx 22.6 115.0 stl ENTRY h 1633 59 30 0.485 4.0 OxO VIFx 8.1 95.0 GREATIDINING-A h 2419 88 78 0.302 7.0 OxO VIFx 30.4 135.0 st2 GREATIDINING-B h 2419 88 78 0.319 7.0 OxO VIFx 21.7 135.0 st2 KITCHEN c 2429 28 117 0.376 7.0 Ox0 VIFx 18.1 115.0 stl LAUNDRY h 995 36 14 0.369 6.0 Ox0 VIFx 20.4 115.0 SH M. BATH h 1059 38 25 0.366 4.0 Ox0 VIFx 21.6 115.0 stl MASTERBEDROOM c 2275 105 109 0285 6.0 Ox0 VIFx 40.5 135.0 st2 MASTERBEDROOM2 c 2416 111 116 0.347 8.0 Ox0 VIFx 29.0 115.0 stl MASTERBEDROOM2-A c 2416 111 116 0.326 6.0 Ox0 VIFx 38.4 115.0 stl MASTERBEDROOM-A c 2275 105 109 0297 6.0 Ox0 VIFx 33.1 135.0 st2 POWDER c 65 3 3 0.379 4.0 Ox0 VIFx 17.1 115.0 SH SrmNG ROOM h 3465 126 115 0289 11.0 0x0 VIFx 38.1 135.0 st2 WIC c 97 4 5 0.309 4.0 Qx0 VIFx 26.6 135.0 st2 Supply Trunk Detail Table Trunk Htg CIg Design Veloc Diam H x W Duct Name Type (cfln) (dm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 516 495 0.285 657 12.0 0 x 0 VinIFIX stl stl PeakAVF 888 917 0.285 657 16.0 0 x 0 VinIFIX wrlghtsoft' 2021-SeP2911.09.34 zt ..,. ..._. �. RigltSutWlhie 1202121.0.08RSW8101 Pagel %1CCA-.wftWAQWYNNE-GEMINI-GARAGE RIGHT-BHOMEnp Calc=M18 Fmd Doorfam& N Name Grille Size(in) Htg (dm) Clg (ctm) TEL (ft) Design FR Ueloc (Tpm) Diem (in) H x W (in) Stud/Joist Opening (in) Duct Mall Trunk rbl NO 1 947 947 0 0 0 0 Ox 0 MFx wrigh sof - 2021Seo-2911:09:34 Mw(s!1 MgNSute®lti.12021 21.0.08 RSW8101 Page 2 ...Soft FNAQWYNNE-GEMNFGARAGE RIGFR-B FiOME.np CaIc=M18 Fmrt Doorfaces N