Loading...
HomeMy WebLinkAboutProduct ApprovalFlorida Building Code Online Page 1 of 2 ProfessionalFLORIDA OUPARTMONT OF Business & Regulation- BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats & Facts i Publications FBC Staff I BCIS Site Map Links Search Florida _ rProduct Approval o USER: Public User esi"`rom Product Approval Menu > Product or Aoolication Search > Application List > Application Detail FL # FL5259-R28 c/�c Application Type Revision CC�r�� Code Version 2017 r6DApplication Status Approved 9 _ Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email POLYGLASS USA 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1378 Ext242 alender@polyglass.com , Ariel Lender alender@polyglass.com Maury Alpert 1111 W. Newport Center Deerfield Beach, FL 3344: (912) 429-8610 MAIpert@polyglass.com Ariel Lender 1111 W. Newport Center Deerfield Beach, FL 33442 (954) 233-1230 ALender@polyglass.com RECEIVED I DEC 13.2018 Permitting Department St. Lucie County, FL Category Roofing Subcategory Underlayments I Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 1 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/05/2018 Validated By John W. Knezevich, PE 12 Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Sta d) ,'R` �.A FL5259 R28 COI 2018 01 COI NIEMINEN.odf Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6164 2011 ASTM D6222 2011 FM 4474 2011 FRSA/TRI April 2012 2012 UL 1897 2012 I https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 Cr.'.. 5/14/2018 Florida Building Code Online Page 2 of 2 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 01/24/2018 01/29/2018 01/30/2018 04/10/2018 FL # Model, Number or Description Name 5259.1 Polyglass Roof Roofing underlayments Underlayments Limits of Use Installation Instructions Approved for use in HVHZ:No FL5259 R28 II 2018 01 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- R28.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this Evaluation Reports application relates to one particular FL5259 R28 AE 2018 01 FINAL ER POLYGLASS UNDERLAYMENTS FL5259- R28.odf underlayment system (over concrete deck) for use under foam -on tile systems Created by Independent Third Party: Yes (where the underlayment forms part of the load -path). Refer to ER Section 5.6.4 for other systems, other deck types and associated maximum design pressures. 2.) Refer to ER Section 5 for other limits of use. Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emaiis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ®� ® — 6 � ,Credit::Card , https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3 Cr... 5/14/2018 NEMO I etc. Certificate of Authorization #t32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT Polyglass USA, Inc. 1111 West Newport Center Drive Deerfield Beach, FL 33442 (954) 233-1230 Evaluation Report P12060.02.09-1124 FL5259-R28 Date of Issuance: 02/24/2009 Revision 24: 01/24/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the.use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the. named client constitutes agreement'to notify. Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOJetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO l etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 14. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 01/24/2018. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO Ietc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO I etc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. O.NEMOJetc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pro a Standard Year 1504.3.1 Wind Uplift FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.3 / 1507.1.1 Physical Properties ASTM D226 2009 1507.2.4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Enti Examination Reference Date FM Approvals (TST 1867) Wind Uplift 3004091 01/12/2000 PRI (TST 5878) Physical Properties PRIO1111 04/08/2002 PRI (TST 5878) Physical Properties PUSA-005-02-01 01/31/2002 PRI (TST 5878) Physical Properties PUSA-013-02-01 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-02 12/23/2002 PRI (TST 5878) Physical Properties PUSA-013-02-03 12/23/2002 PRI (TST 5878) Physical Properties PUSA-018-02-01 07/14/2003 PRI (TST 5878) Physical Properties PUSA-028-02-01 07/13/2005 PRI (TST 5878) Physical Properties PUSA-033-02-01 01/12/2006 PRI (TST 5878) Physical Properties PUSA-035-02-01 09/29/2006 PRI (TST 5878) Physical Properties PUSA-055-02-02 12/10/2007 PRI (TST 5878) Physical Properties PUSA-061-02-02 01/28/2008 PRI (TST 5878) Physical Properties PUSA-076-02-01 02/22/2008 PRI (TST 5878) Physical Properties PUSA-083-02-01 04/14/2008 PRI (TST 5878) Physical Properties PUSA-088-02-01 07/29/2009 MT] (TST 2508) Physical Properties JX20H7A 04/01/2008 MTI (TST 2508) Physical Properties RX14E8A 01/29/2009 ERD (TST 6049) Physical Properties 11752.09.99-1 02/08/2000 ERD (TST 6049) Wind Uplift 11757.08.01-1 08/13/2001 ERD (TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD (TST 6049) Physical Properties 02200.07.03 07/14/2003 ERD (TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD (TST 6049) Physical Properties P5110.04.07-1 04/11/2007 ERD (TST 6049) Wind Uplift P9260.03.08 03/21/2008 ERD (TST 6049) Physical Properties P13450.08.09 08/13/2009 ERD (TST 6049) Wind Uplift P30540.11.09-R1 11/30/2009 ERD (TST 6049) Physical Properties P11030.11.09-1 11/30/2009 ERD (TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 ERD (TST 6049) Physical Properties P11030.11.09-3 11/30/2009 ERD (TST 6049) Physical Properties P33360.06.10 06/25/2010 ERD (TST 6049) Physical Properties P33370.03.11 03/02/2011 ERD (TST 6049) Physical Properties P33370.04.11 04/26/2011 ERD (TST 6049) Physical Properties P37300.10.11 10/19/2011 NEMO ETC, U.C. Evaluation Report P12060.02.09-R24 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 2 of 14 ONEMO etc. KnOty Examination Reference Date ERD (TST 6049) Physical Properties P40390.08.12-1 08/06/2012 ERD (TST 6049) Physical Properties P40390.08.12-2 08/07/2012 ERD (TST 6049) Physical Properties C41420.09.12-3 09/11/2012 ERD (TST 6049) Wind Uplift P39680.03.13 03/04/2013 ERD (TST 6049) Physical Properties P45370.04.13 04/26/2013 ERD (TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 ERD (TST 6049) Wind Uplift 11757.04.01-1-R1 04/30/2013 ERD (TST 6049) Wind Uplift P41630.08.13 08/06/2013 ERD (TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 ERD (TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 ERD (TST 6049) Physical Properties P45270.05.14 05/12/2014 ERD (TST 6049) Physical Properties 6020.07.14-1 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-2 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-3 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-4 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-5 09/08/2014 ERD (TST 6049) Physical Properties 6020.09.14-6 09/08/2014 ERD (TST 6049) Physical Properties P46520.10.14 10/03/2014 ERD (TST 6049) Physical Properties P43290.10.14 10/17/2014 ERD (TST 6049) Physical Properties PLYG-SC7550.03.15 03/24/2015 ERD (TST 6049) Physical Properties P40390.04.15 04/03/2015 ERD (TST 6049) Physical Properties P44360.10.14-R1 05/18/2015 ERD (TST 6049) Physical Properties PLYG-SC8080.05.15-1 05/20/2015 ERD (TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016 ERD (TST 6049) Physical Properties PLYG-SC8080.07.16 07/16/2016 ERD (TST 6049) Wind Uplift PLYG-SC12025.10.16 10/12/2016 ERD (TST 6049) Physical Properties PLYG-SC13040.12.16 12/27/2016 ERD (TST 6049) Physical Properties PLYG-SC11900.03.17 03/10/2017 ERD (TST 6049) Physical Properties PLYG-SC12115.08.17 08/08/2017 ICC-ES (EVL 2396) IBC Compliance ESR-1697 11/01/2014 Miami -Dade (CER 1592) HVHZ Compliance NOA 14-0717.08 01/22/2015 Polyglass USA Manufacturing Affidavit Products Current 02/18/2009 Polyglass USA PA Affidavit Mule -Hide Cross Ltg 03/01/2008 Polyglass USA Materials Affidavit Polystick SA Compound 08/18/2011 UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 10/05/2018 4. PRODUCT DESCRIPTION: 4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet. 4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet. 4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet. 4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet. 4.2.1 Polystick MTS or Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced with polyolefinic film surface; meets FRSA/TRI April 2012. 4.2.2 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface; meets ASTM D1970. 4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. NEMO ETC, LLC. Evaluation Report P12060.02.09-R24 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 3 of 14 0.NEM01-etc. 4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface; meets FRSA/TRI April 2012. 4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 4.2.6 Polyflex SAP, Polyflex SAP FIR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FIR) are polyester reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012. 4.2.7 Polystick Dual ProTM' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970. 4.2.8 Polystick Tile ProTM' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012. 4.2.9 Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D1970 (See Section 5.8). 4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. 4.3.2 Elastoflex S6 G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164. Elastoflex S6 G and Elastoflex S6G FIR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, . Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Elastoflex S6 G FIR is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems. 4.3.3 Polyflex G and Polyflex G FIR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222. Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FIR is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEM01etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. NEMO ETC, LLC. Evaluation Report P12060.02.09-R24 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 4 of 14 01NEM0 I etc. 5.5 Allowable Roof Covers: .41 . ..TABU 1 ROOF COVER OPTIONS` , ,a Underlayment Asphalt Shingles Nail -On Tile Foam -On Tile Metal wood Shakes BE Shingles Slate Elastobase Yes s (Base Sheet net -ply system) Yes (Base Sheet in 2-ply system) Yes Yes Yes Elastobase P Yes Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) Yes Yes Yes Polyglass G2 Base No Yes (Base Sheet in 2-ply system) Yes (Base Sheet in 2-ply system) No No No Polygla55APP Base No s (Base Sheet nee -ply system) Yes (Base Sheet n2-ply system) No No No Polystick MTS or MTS PLUS Yes Yes No Yes Yes Yes Polystick IR-Xe Yes No No No Yes Yes Polystick TU P No Yes Yes (See 5.5.1) No No No Polystick TU Plus Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick TU Max No Yes Yes (See 5.5.1) Yes No No Polystick Dual Pro Yes No No Yes Yes Yes Polystick Tile Pro Yes Yes Yes (See 5.5.1) Yes Yes Yes Polystick MU-X Yes No No Yes Yes Yes Elastoflex S6 G Yes Yes Yes (See 5.5.1) No Yes Yes Elastoflex S6 G FR Yes Yes No No Yes Yes Elastoflex G TU Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G Yes Yes Yes (See 5.5.1) No Yes Yes Polyflex G FR Yes Yes No No Yes Yes Polyflex SAP or SAP FR Yes Yes Yes (See 5.5.1) 1 No Yes Yes Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Yes Yes Yes (See 5.5.1) No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE;IA ALLOWABIETILE/1UHE51VE�UNDERUIYIUIENTCOMBINATlONS3 Adhesive Florida Product Underlayments Approval DAP Foam Touch 'n Seal StormBond Roof FL14506 Polystick TU Plus, Polystick TU Max Tile Adhesive Dow TileBondT" FL22525 Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset® AH-160 FL6332 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro, ICP Adhesives Polyset® RTA-1 FL6276 Elastoflex G TU, Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR) 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R24 Certificate of Authorization #32455 6t" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 5 of 14 O-N EMO I etc. 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels (designed and installed to meet wind loads for project). Note: Polyglass does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D41 primed structural concrete. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete. 5.6.2 Bond -to -Insulation: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered to: ➢ ASTM C1289, Type II, Class 1 polyisocya n u rate or Type V polyisocyanurate-composite insulation; Dens Deck DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. Polyflex G or Polyflex G FR torch -applied to: ➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FBC Section 1504.3.1. 5.6.3 Bond to Mechanically Attached Base Laver: Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or Tile Pro self -adhered to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base. Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to: ➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base. Polyflex G or Polyflex G FR torch -applied to: ➢ Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC Section 1504.3.1. NEIVIO ETC, I.I.C. Evaluation Report P12060.02.09-R24 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 6 of 14 ONEMOletc. 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04- 12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #2 Maximum Design Pressure=-97.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1%" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure = -105 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1'/0" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure = -135 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #5 Maximum Design Pressure = -315 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #6 Maximum Design Pressure = -622.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #7 Maximum Design Pressure = -30.0 psf*: Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. NEIVIO ETC, U.C. Evaluation Report P12060.02.09-R24 Certificate afAuthorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 7 of 14 ONEMOletc. #8 Maximum Design Pressure = -37.5 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: it ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #9 Maximum Design Pressure=-37.5 psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #10 Maximum Design Pressure = -45 psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: One (1) layer ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt. #11 Maximum Design Pressure = -45 psf*: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Two (2) layers ASTM D226, Type II felt Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows. Base Ply: (Optional; for use with self -adhering underlayment only) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. #12 Maximum Design Pressure = -45 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #13 Maximum Design Pressure = -52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #14 Maximum Design Pressure = -52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. NEMO ETC, U.C. Certificate of Authorizotion #32455 CH EDITION (2017) FBC NON-HVHZ EVALUATION Polyglass Roof Underlayments; (954) 233-1230 Evaluation Report P12060.02.09-R24 FL5259-R28 Revision 24: 01/24/2018 Page 8 of 14 #15 #16 #17 #18 #19 #20 #21 Maximum Design Pressure = -52.5 psf: Deck: Min. 15/32-inch plywood to meet project requirer Base Sheet: Elastobase (sanded top surface for hot -asphalt or ,Fasteners: Simplex Original Cap Nails Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch i Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full m Maximum Design Pressure = -60 asf: Deck: Min. 19/32-inch plywood to meet project requirer Base Sheet: Elastobase (sanded top surface for hot -asphalt or Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter a Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch i Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full m Maximum Design Pressure = -60 psf: Deck: Min. 19/32-inch plywood to meet project requirer Base Sheet: Elastobase (sanded top surface for hot -asphalt or Fasteners: OMG #12 Standard Roofgrip with OMG Flat Bottor Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inc Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full m Maximum Design Pressure = -67.5 psf: Deck: Min. 15/32-inch plywood to meet project requirer Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires i Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter ai Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch r Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in ful applied. Maximum Design Pressure = -75 psf: Deck: Min. 15/32-inch plywood to meet project requiren Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires i Fasteners: Dekfast #14 with Dekfast Hex plates, CMG #14 H1 OMG Flat Bottom Plates (AccuTrac), Trufast H[ Fasteners Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inc Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in fu applied. Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project required Base Sheet: Elastobase (sanded top surface for hot -asphalt or 1 Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch < Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full M Maximum Design Pressure = -90 psf: Deck: Min. 15/32-inch plywood to meet project requin Base Sheet: Elastobase (sanded top surface for hot -asphalt c Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-incl Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full #22 Maximum Design Pressure = -90 Dsf: O.NEMOJetc. to satisfaction of Authority Having Jurisdiction. applied cap or poly -film surface for torch -applied cap) at four (4) equally spaced staggered center rows. Ping of hot asphalt or Polyflex G, torch -applied. is to satisfaction of Authority Having Jurisdiction. h-applied cap or poly -film surface for torch -applied cap) lar ring shank roofing nails at 1-5/8-inch diameter tin caps at three (3) equally spaced staggered center rows. ling of hot asphalt or Polyflex G, torch -applied. ?nts to satisfaction of Authority Having Jurisdiction. arch -applied cap or poly -film surface for torch -applied cap) Metal Plates o.c. at two (2) equally spaced staggered center rows. pping of hot asphalt or Polyflex G, torch -applied. !nts to satisfaction of Authority Having Jurisdiction. :e of torch -applied underlaymentJ velar ring shank roofing nails at 1-5/8-inch diameter tin caps c. at four (4) equally spaced staggered center rows. mopping of hot asphalt or torch -applied or Polyflex G, torch- !nts to satisfaction of Authority Having Jurisdiction. e of torch -applied underlaymentJ with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with with Trufast 3-inch Insulation Plates or Simplex MAXX Cap h o.c. at three (3) equally spaced staggered center rows. I mopping of hot asphalt or torch -applied or Polyflex G, torch - to satisfaction of Authority Having Jurisdiction. applied cap or poly -film surface for torch -applied cap) at two (2) equally spaced staggered center rows. ling of hot asphalt or Polyflex G, torch -applied. nents to satisfaction of Authority Having Jurisdiction. torch -applied cap or poly -film surface for torch -applied cap) )uty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal o.c. at three (3) equally spaced staggered center rows. lopping of hot asphalt or Polyflex G, torch -applied. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" MMetal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full opping of hot asphalt. NEMO ETC, LLC. Evaluation Report P12060.02.09-R24 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 9 of 14 ONEMOletc. #23 Maximum Design Pressure=-90 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment) Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch - applied. #24 Maximum Design Pressure=-97.5 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows. Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered. Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #25 Maximum Design Pressure = -105 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: Simplex MAXX Cap Fasteners Spacing: 6-inch o.c. at the 2-inch wide side laps and-6-inch o.c. at three (3) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #26 Maximum Design Pressure = -112.5 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface) Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows. Primer: PG100 or ASTM D41 primer at all tin -caps Base Ply: Polystick MTS or Polystick MTS PLUS, self -adhered Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered. #27 Maximum Design Pressure = -120 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap) Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied. #28 Maximum Design Pressure = -120 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase (sanded top surface) Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows. Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt. 5.6.4.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. MEMO ETC, LLC. Evaluation Report P32060.02.09-R24 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 10 of 14 O.NEMO etc. 5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days after installation. Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation. Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for longer than 180-days after installation. Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30 days. Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the prepared roof covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180 days. 5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226 roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance. 5.9 Tile Slippage Limitations (FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. 'TABLE 2 TILE SLIPPAGE LIMITATIONS FOIL DIRECT ,DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Elastoflex G TU Flat 10-tile stack 7:12 Lugged 8-tile stack (6 over 2) 6:12 Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polystick MTS or MTS PLUS Flat 6-tile stack (4 over 2) 5:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick Tile Pro Flat or Lugged 6-tile stack (4 over 2) 7:12 Polystick TU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:12 Lugged 6-tile stack (4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystick TU P Flat 6-tile stack (4 over 2) 6:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick TU Plus Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 Polyflex G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack (4 over 2) 4:12 NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R24 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 11 of 14 ONEMOletc. 6. INSTALLATION: 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6 3 Elastobase, Elastobase P orlVlu .le Htde Nall Base 6.3.1 Non -Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. 6.3.2 Tile Applications: Elastobase, Elastobase P or Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the "Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with FRSA/TRI April 2012 (04-12) Installation Manual. 6.4.1 Shall be installed in compliance with the codified requirements for ASTM D1970 (except Polystick TU P) underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.4.2 Direct -to -Deck with Mechanically Fastened Roof Covers: All self_adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule - Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back - nailed using the above noted fasteners and spacing, in area marked "nail area, area para clavar" on the face of membrane. The head lap membrane is to cover the area being back -nailed. All seal -lap seams (selvage laps) must be firmly rolled with a minimum 28 lb. hand me. roller to ensure full contact and adhesion. .00, For Dual Pro and Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). View of Ovelap Seam of Dual Pro and Tile Pro All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap. Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R24 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1129 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 12 of 14 ONEMOjetc. Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be installed in a water shedding manner. All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied for the field membrane. Hand rollers -are acceptable for rolling of patches, laps (min. 28 lb roller) or small areas of the roof that are not accessible to a large roller or broom. 6.4.3 Tile Applications (not allowed for Polystick Dual Pro, IR Xe or Polystick MU-X): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1. For adhesive -set tile applications, refer to Section 5.6.4 herein. 6.4.4 Two (2) Ply UnderlaVment SVstems: Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Polystick MTS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use under foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. r 6 5 R Elastoflex G TU,`Elastoflex S6 G or Elastoflex 56 G FR 6.5.1 Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2022 (04-12) beneath mechanically fastened or adhered tile roof systems. ✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems. 6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR shall be fully asphalt -applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. 6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass published installation requirements. For use in tile applications: ✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems (Base Sheet Limited per 5.6.3). ✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3). NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R24 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1128 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 13 of 14 I ONEMOjetc. 6.6.2 Polyflex G or Polyflex G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge. ' 6.7 Tile Staging: 6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Polyglass published requirements for tile staging. 6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail- boards, to prevent tile sliding and/or damage to the underlayment during the loading process. 6.7.3 Polyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight (48) hours. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 CA requirements. The following plants have qualified products under their respective physical properties specifications. Plant ° Specifcat�on ;: Produ sct ,... ,._ ,. ,._.. . Fernley, NV, Hazleton, PA & Winter Haven, FL ASTM D1970 Polystick MU-X Hazleton, PA M-D 13-0004 Elastoflex G TU Hazleton, PA & Winter Haven, FL ASTM D1970 Polystick IR-Xe ASTM D1970 & FRSA/TRI April 2012 Polystick TU Plus ASTM D1970 & FRSA/TRI April 2012 Polystick TU Max Tuscaloosa, AL ASTM D4601, Type II Polyglass G2 Base Winter Haven, FL ASTM D226 (physicals) Elastobase, Elastobase P ASTM D6509 Polyglass APP Base FRSA/TRI April 2012 Polystick MTS, Polystick MTS PLUS FRSA/TRI April 2012 Polystick TU P FRSA/TRI April 2012 Polyflex SAP, Polyflex SA P FR ASTM D1970 Polystick Dual Pro ASTM D1970 & FRSA/TRI April 2012 Polystick Tile Pro ASTM D6164 Elastoflex S6, Elastoflex S6 G FR ASTM D6222 Polyflex G, Polyflex G FR 9. QUALITY ASSURANCE ENTITY: UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - NEMO ETC, U.C. Evaluation Report P12060.02.09-R24 Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R28 Polyglass Roof Underlayments; (954) 233-1230 Revision 24: 01/24/2018 Page 14 of 14 3� +V ♦� }. ; � � r. � �4. � � i'a$ - R�� 'wy �� y,.�, :{ r � _9 '� �.! , LF- b ne �.° ���rd�fess�ora�I�,R�giil�t�or�� ;} `�; ���� ` � �'��1��� �►�� '� BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications F13C Stff BCIS Site Map Links Search ba uER; Public User ir _,.IProduct Approval FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory FL9777-R11 Revision 2017 Approved Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Greg Keeler greg.keeler@owenscorning.com Roofing Underlayments RECEIVED DEC 13 2018 Permitting Department St. Lucie County, FL Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect,Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden tl Validation Checklist - Hardcopy Received, Certificate of Independence FL9777 R11 COI OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.odf Referenced Standard and Year (of Standard) Standard Year ASTM D 1970 2015 ASTM D 226 2009 ASTM G 155 2005 TAS 103 1995 UL1897 � � 2012 Equivalence of Product Standards Certified By _.lam Sections from the Code vii�v Product Approval Method Method 1 Option D Date Submitted 10/11/2017 Date Validated 10/11/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Summary of Products FL # Model, Number or Name Description 9777.1 Weatherlock G Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 Rll II OCR14002.8a 2017 FBC Evaluation Reoort Weatherlock Non-HVHZ.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 Rll AE OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Created by Independent Third Party: Yes 9777.2 WeatherLock G (High Tear) Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 Rli II OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 Rll AE OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Created by Independent Third Party: Yes 9777.3 Weatherlock MAT Waterproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL9777 R11 II OCR14002.8b 2017 FBC Evaluation Report Weatherlock HVHZ.odf Approved for use outside HVHZ: No Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE OCR14002.8b 2017 FBC Evaluation Report Weatherlock HVHZ.pdf Created by Independent Third Party: Yes 9777.4 Weatherlock MAT Waterproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 Rll I1 OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 Rll AE OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Created by Independent Third Party: Yes 9777.5 WeatherLock Metal Weatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL9777 R11 II OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL9777 R11 AE OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Created by Independent Third Party: Yes 9777.6 WeatherLock Metal Weatherproofing Underlayment Limits of Use Approved for use in HVHZ: Yes Installation Instructions FL9777 R11 II OCR14002.8b 2017 FBC Evaluation Report Weatherlock HVHZ.pdf Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: N/A Other: See evaluation report for limits of use. 9777.7 Weatherl-ock Specialty Tile & Metal Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-142.5 Other: See evaluation report for limits of use. Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R11 AE OCR14002.8b 2017 FBC Evaluation Report Weatherlock HVHZ.odf Created by Independent Third Party: Yes Weatherproofing Underlayment Installation Instructions FL9777 Ril II 0CR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Verified By: Zachary R. Priest 74021 Created by Independent Third Party: Yes Evaluation Reports FL9777 R11 AE OCR14002.8a 2017 FBC Evaluation Report Weatherlock Non-HVHZ.pdf Created by Independent Third Party: Yes eac{< Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emaiis provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card Safe Certificate of Authorization bur 29824 CREEK17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL SERVICES, LLC (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 6T" EDITION (2017) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued October 11, 2017 1 Owens Corning Parkway Toledo, OH 43657 (800)438-7465 www.owenscorning.com Manufacturing Location: Brentwood, NH Houston, TX Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1, 1507.1.1 Properties: Physical properties REFERENCES EaWy Report No. Standard Year PRI Construction Materials Technologies (TST5878) NEI-039-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) NEI-042-02-01 REV2 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) NEI-045-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) NEI-045-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) NEI-053-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) NEI-053-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) NEI-093-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-213-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies (TST5878) OCF-237-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST5878) OCF-252-02-01 ASTM D 4798 2001 PRI Construction Materials Technologies (TST5878) OCF-252-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-253-02-02 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-272-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST5878) OCF-296-02-02 ICC-ES AC 188' 2012 ICC-ES AC 48 2012 PRI Construction Materials Technologies (TST5878) OCF-297-02-01.1 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-318-02-01 ASTM D 1970 2015 PRI Construction Materials Technologies (TST5878) OCF-320-02-01 TAS 103. 1995 PRI Construction Materials Technologies (TST5878) OCF-320-02-01 ASTM G 155 2005a PRI Construction Materials Technologies (TST5878) OCF-321-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies (TST5878) OCF-322-02-01 UL 1897 2012 PRI Construction Materials Technologies (TST5878) OCF-355-02-01 UL 1897 2012 'Determined to be equivalent to ASTM D 226-09, Type I and II OCR14002.8a FL9777-R11 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. :1- CREEK TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION AND LIMITS OF USE OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock@) Self -Sealing Ice & Water Barriers WeatherLock@ G WeatherLock@ G is an ASTM D 1970 self-adhesive underayment constructed from SBS (Brentwood, NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ G is permitted to be used as prescribed in FBC Section 1507.1.1 for i mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@ Mat WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood, NH or SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- Houston, TX) sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@ Metal WeatherLock@ Metal is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood, NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock@ Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock@ WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment Specialty Tile & Metal constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric. (Brentwood, NH or The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft. Houston, TX) WeatherLock@ Specialty Tile & Metal is permitted to be used as prescribed in FBC Section 1507.1.1. WeatherLock@ Specialty Tile & Metal is permitted to be used with adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP Adhesives and Sealants, Inc.) or TILE BONDTm Roof Tile Adhesive (The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with clay or concrete the installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. WeatherLock@ G (High WeatherLock@ G (High Tear) is a self -adhered, underlayment used as an alternative to Tear) ASTM D 226, Type I or Type II roofing felt and ASTM D 1970 self -adhering polymer (Houston, TX) modified bitumen underlayment. The underlayment is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. WeatherLock@ G (High Tear) is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. OCR14002.8a FL9777-R11 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC PRODUCT APPLICATION OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing Ice & Water Barriers Min. Roof Slope: 2:12 in accordance with the FBC Application: All underlayments shall be- installed in accordance with the FBC. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3" side laps and minimum 6" end laps staggered min. 6-ft.from preceding course. Additionally, if applying WeatherLock® Specialty Tile & Metal, end laps shall be primed with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap. It is permissible to back nail the underlayment 12-inches on -center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed when installed on roof slopes greater than 3:12. Min. Application 40°F; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlavment Svstem No.1 — WeatherLock SDecialty Tile & Metal Only Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24" o.c. Underlayment: WeatherLock® Specialty Tile & Metal shall be applied in accordance with manufacturer's installation instructions to the fastened deck and backnailed along the selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied underlayment shall be rolled with a minimum 751b steel roller immediately following application. Maximum Design -142.5 psf Pressure: OCR14002.8a FL9777-Rl l Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC GENERAL LIMITATIONS OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing Ice & Water Barriers 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given underlayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 6t' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. `��u�unrrr�i %G�PFtY R..p�/�,��, No 74021 STATE OF i, �'•. O R t Q,.•' N CERTIFICATION OF INDEPENDENCE 2017.10.11 09:06:29 041001 Zachary R. Priest, P.E. Florida Registration No. 74021' Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14002.8a FL9777-R11 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. -1- _ _ Lullul116 VUUC VnIme i Page 1 of 3 - - Floridar W FULLS I Fuoucations j FBC Staff BCIS Site Map F L Product Approval USER: Public User Product Aooroval Menu > Product or Aoolication 1 Search > Application List de Version 2017 FL# �A plication Type ALL Product Manufacturer tegory ALL Subcategory plication Status ALL Compliance Method (' � ality Assurance Entity ALL Quality Assurance Entity Contract Expired duct Model, Number or Name ALL Product Description proved for use in HVHZ ALL Approved for use outside HVHZ Impact Resistant ALL Design Pressure Other ALL FL# V Min_Ufa CfiArer FL239-R25 Revision PGT Industries History Category: Windows Subcategory: Single Hung FL242-R2 ,a-N f - ALL PGT Industries ALL ALL ALL ALL ALL ALL �aledatde@ �' 2 Stagy Miami -Dade BCCO - VAL Approve. (786) 315-2590 PGT Industries „ T�'a� Histor :Cate Miami Dac gory 1Nindows 786 Subcategory :Horizontal Slider'( ) 3i5 IOW&n� http://www-floridabuilding.org/pr/pi app Ist.aspx BCCO VAL Approve i90 6/14/2018 Page 2 of 3 FL24FL24-- 3-R20 Revision PGT Industries Histor Category: Windows Miami -Dade BCCO - VAL Approve, Subcategory: Fixed (786) 315-2590 •`FL245 Rt2 H Revision '------ ,: PGT Industries History Category Windows< < Subcate.. o ry Miami -Dade' BCCQ (786)`315.2590 VAL A Ppr ;9 .Casement EL2— 5-0 Revision PGT Industries J History Category: Exterior Doors Miami -Dade BCCO - VAL Approve, Subcategory: 9 ry. Sliding Exterior Door Assemblies (786) 315-2590 i~L2518Revision ^4_ PGT InduS:tnes `v_ category Exterior Doors y"gam�=Dade BCCO` VAL ` Approve "" - s .,r ° Sub`category• SWIn m 315 2590 FL261-_R11 Revision g :g Exterior Door Assemblies (786) PGT Industries His- Category: Windows Miami -Dade BCCO - VAL Approve Subcategory Mullions 8 - 7 6) 315 2590 FL33-_6 Revision PGTY stries Mast°ryr Category :Windows S teven M Urich PE Subcategory Casement (717) 317 8454 APProye FL3— 3� Affirmation PGT Industries History Category: Exterior Doors Steven M. Urich, PE Approve, Subcategory Swinging Exterior Door Assemblies (717) 317-8454 FL14— 3— 5=R20 Revision PGt Industries Histor _ :Category :Windows Steven M Urich, PE . Approve -` � ;< .> _Subcategory Single Hung �; (717) 317 8454 - - =11844-R23 Revision PGT Industries -listory Category: Windows Steven M. Urich, PE Approve. Subcategory: Horizontal Slider (717) 317-8454 httP://www.floridabuilding.org/Pr/pl�-aPp-Ist.aspx 6/14/2018 Page 3 of 3 HIs— PGT Ind x ustrles = Cat V :Inflows ' , w Steven M: Urich, PE :,. - category - (717):"317.8454 - FL7058-R16 Revision PGT Industries History Category: Windows Steven M. Urich, PE Approve _ Subcategory: Double Hung (717) 317-8454 ;FL14705 R5 Revislon PGT Jndustries . Mis— tom Cate9orY Windows Miami -Dade :BCCO VAL ApproVe 5u category Hun (786)`315 2590 --Double FL17519-R3 Affirmation PGT Industries g Hist°ry Category: Windows Steven M. Urich, PE Approve, Subcategory: Mullions (717) 317-8454 FL21179 R2 Revision • PGT;;Industries Histo�}L CategoryS ;f t e `: Exterior Doors ev n M Urich, PE Subcate o (717) 3:17 8454 9. ry Sliding :Exterior Approve; Door Assemblies "Approved by DBPR. Approvals by DBP._ :. y , .•,.,: ::. 4 R shall be reviewed and ratified b the POC and/or the Commission • if necessary. Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Co ri ht 2007-2013 Stare �f Fi .+ ;; c Under Florida law, email addresses are public rPrivacy Statement :: Accessibility Statement :: Refund u do not want your e-mail address released in response to a public -records request, electronic mail to this entity. Instead, contact thecords. If yo e office by phone or by traditional mail. If you have an Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department withthey have one. The emails provided may be used for official communication with the licensee. However email addre addresses are public record. 1395. supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if YIf you You an e c Chapter 455, F.S., please click here . you are Product Approval Accepts: http://W�,floridabuilding.org/pr/pr app_lst.aspx 6/14/201 R