HomeMy WebLinkAboutTruss ( 9-20-2018 )11!__ 11�111111=y 11 ViN
BACK 3/4" FOR EXT.
SHEATHING.
(TYPICAL)
Manuf
Product
Qty
Simpson
HGUS210-2
2
Simpson
HHUS266-2
5
Simpson
HHUS48
4
Simpson
HUS26
28
Simpson
HUS28-2
8
RN39TA1111111M
RE111
I
EIVED
SAP 2 7 2018
-S _T. Lucie County
ENGINEERED TIMBER
TRUSS SYSTEMS —IMF PRODUCTS
0
EIT 'IT -
EAST COAST TRUSS (D
5285 ST. LUCIE BLVD. Fr. PIERCE, FL 34946
OFFICE: (772) 466-2480 FAX: (772)466-5336
•
SQ FT 180
DATE 09/20/18
61G15S-31.003 (3) (c), LAST COAST TRUSS is the
"Truss Design Engineer"
Trusses are designed in accordance with the
Florida Building Code
NOTE:
A
By approving this placement plan(s), signatured
anywhere on this sheet, the customer or his
representitive acknowledges that this placement plan
complies with the structural intent of the project.
The customer also acknowledges that this approval
authorizes EAST COAST TRUSS to manufacture these
trusses and deliver them to the project indicated on this
drawing.
The customer also acknowledges that he/she accepts
financial responsibility for any repair, engineering, and
labor required due to errors other than those of EAST
<k
COAST TRUSS.
Z
Signed: —Date:
LL
W1
ODE = FBC 2017ITP12014 ASCE 7-10
ESIGN CRITERIA =MWFRS
CCUPANCY CATEGORY=
KPOSURE = D
IWF SPEED = 180
UILDING TYPE =ENCLOSED
EAN HEIGHT: 2700
TM
GRAVITY LOADS I UPI
FLOOR: DUR FACTOR= 1.0
PSF=TCLL-TCDL-BCLL-BCDIL
,li-00,0-0,5.0
OOF: DUR FACTOR= 1.25
I)i!7=TCLL-TCDL-BCLL-BCDL-
20.0,15.0,0.0,10.0 J,
LOADS PER FBC & FRC
*NON -CONCURRENT BC ILL 10psf
CONCURRENT BC STORAGE LL 20 psf
-------------
MWF MAIN WIND FORCE
C&C COMPONENTS AND CLADDING
TOB TOP OF BEARING
TIC TOP CHORD
BC BOTT OM CHORD
LL LIVE LOAD
DL DEAD LOAD
psf POUNDS PER SQUARE FOOT
# POUNDS
ll,rPL-rFT-MUS7-BY--7r'-'ASS-FUGO R - TWO!
UNLESS SHOWN ON ENGINEERED TRUSS
DRAWING.
ALL GIRDER/COLUMN LOADS MUST
BY-PASS FLOOR TRUSS UNLESS SHOWN
ON ENGINEERED TRUSS DRAWING.
L
tX6- S IRONG BACK BRA-C ",u - 0. 1
RECOMMENDED ON FLOOR TRUSSES
SPANNING 20�-O" OR MORE
TION: SPANS GREATER rnXR 30 -
jUST BE SET WITH A SPREADER BAR. THE
PREADER BAR SHOULD BE AT LEAST 1/2
0
13 IN LENGTH AS THE SPAN OF THE TRUSS
EING SET.
0000
'EFER TO BCI-B1 FOR COMPLETE
RECTION AND SAFETY PROCEDURES.
ALL BEAMS BY BUILDER
1- V_
2- 4-
3- 0
4-
5-
6- (D)
7H - IS , IS , A I PLACEMENT PLAN FOR ENGfNEEREb_____
COMPONENTS AS DEFINED BY WTCA 1 - 1995.
DIAPHRAMS HAVE NOT BEEN ANALYZED BY
EAST CAOST TRUSS -
:OR ERECTION AND INSTALLATION OF TRUSSES
FOLLOW INSTRUCTIONS ON THE BCSI-131 SUMMARY
SHEETS AND SEALED ENGINEERED TRUSS DRAWINGS
- - ----- -------- ------------------ __
----------- --
,,RACING:
1) FOR THE ERECTION BRACING FOLLOW
4STRUCTIONS ON THE BCSI-131 SUMMARY SHEETS
2) PERMANENT BRACING FOR THE STRUCTURE IS HE
ESPONSIBILITY OF OTHERS.
3) INSTALL WEB BRACING AS STATED ON SEALED
NGiNEERIN%'-:; TRUSS DRAWINGS.
STRUCTURAL DATA, NUMBER OF GIRDER AND TRUSS
PLIES AND THE ��,'ONINECTIONI INFORMATION.
OUR DESIGN DEPARTMENT MUSTIAPPROVE
ALTERATIONS AND/OR REPAIRS TO TRUSSES IN
ADVANCE.
9 -0
9'-4" A. F.F.
16-0" A. F.F.
RECEIVED
SEP 2 7 2018
ST, woe county, "Ktinq
i tL.,N,(_A NEER W U TIM BER
WK.
- Iss -,fSTEWS P30DUCTS
0
LET
EAST COAST TRUS&;_zj
C*-:
5285 ST, LUCIE BLVD. FT. PIERCE FL. 349,16
M
C*.
OFFICE: (772)466-49.480 F&M (772)1-6f;-f-533r1
Odeh
[USTOMER:Anthony
OB NAME.- Odeh Residence
DDRESS-12461 Indian River Drive
W
ITY/'COUNTY-.Jensen Beach / Martin
U)
<
EOB # J36756
4S
OB #
!ODEL:Custom Re -Model
ARAGE
Q FT 398
ATE 09/20/18
IN ACCORDANCE WITH THE FWAIDA ADMINISTRATIVE CODE
61GISS-31.003 (3) (c), EAST COAST TRUSS is the
"Truss Design Engineer"
Trusses are designed in accordance with the
Florida Building Code 2007
By approving this placement plan(s),
ignatured anywhere on this sheet, the customer
r his representitive acknowledges that this
lacement plan complies with the structural intent
f the project.
The customer also acknowledges that this
pproval authorizes EAST COAST TRUSS to
ianufacture these trusses and deliver them to
,e project indicated on this drawing.
The customer also acknowledges that he/she
ccepts financial responsibility -for any repair,
ngineering, and labor required due to errors
then than those of EAST COAST TRUSS.
Date:
CODE: FBC 2007 w/ 09 SUPPLEMENT ASCE 7-05
_OADING:
MEAN HEIGHT:
MPORTANCE FACTOR=
_:XPOSURE CATAGORY=C
AWF SPEED- 140 M.P.H.
3UILDING TYPE.- ENCLOSED
FRUSS SPACING 24" O.C. EXCEPT AS NOTE
FLOOR: DUR FACTOR= 1.0
PSF=TCLL-TCDL-BCLL-BCDL
40.0,10.0,0.0,5.0
ROOF: DUR FACTOR= 1.25
PSF=TCLL-TCDL-BCLL-BCDL
20.0,15.0,0.0110.0
•N_ 9-
alm
ID Me
I
I
CONCURRENT BC STORAGE LL 20 psf
0
F_
DEFINITIONS
MWF = MAIN WIND FORCE
C&C = COMPONENTS AND CLADDING
F_
TOB = TOP OF BEARING
0
TC = TOP CHORD
Z
BC = BOTTOM CHORD
LL = LIVE LOAD
0
DL = DEAD LOAD
psf = POUNDS PER SQUARE FOOT
0
# =POUNDS
UNLESS SHOWN ON ENGINEERED TRUSS
DRAWING.
2X6_STRONG BACK BRACING, 10�-O" O.0 _f9__
:
RECOMMENDED ON FLOOR TRUSSES
SPANNING 20�-O" OR MORE
_rRANIX--oll -
-�A(MOKSRAKSGREATEk
0UST BE SET WITH A SPREADER BAR. THE�
T
F"PREADER BAR SHOULD BE AT LEAST 1/2
_0
t_/3 IN LENGTH AS THE SPAN OF THE TRUS
'W"EING SET.
'\"EFER TO BCI-B1 FOR COMPLETE
E-RECTION AND SAFETY PROCEDURES.
ALL BEAMS BY BUILDER
NOTE: TRUSSES DO NOT
SUPPORT ANY PLANT SHELVES
REVISIONS %+--
0
I
MIL
IRON ��i u
W1 a,
M,!Tek 0
RE: J36756
Odeh Residence
Site Information:
Project Customer: Anthony Odeh
Lot/Block:
Address: 12461 Indian River Drive
City: Jensen Beach
Project Name: J36756
Subdivision:
State: Florida
MiTek USA, Inc.
6904 Parke East Blvd.
Tampa, FL 33610-4115
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.2
Wind Code: ASCE 7-10 Wind Speed: 180 mph Design Method: Components/Cladding ASCE 7-10
Roof Load: 45.0 psf Floor Load: N/A psf
This package includes 14 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No. Seal# Truss Name Date
1
T15139592
e01 g
9/20/18
2
T15139593
v7
9/20/18
3
T15139594
v9
9/20/18
4
T15139595
v12
9/20/18
5
T15139596
v15
9/20/18
6
T15139597
v18
9/20/18
7
T15139598
v21
9/20/18
8
T15139599
zcj1a
9/20/18
9
T15139600
zcj1b
9/20/18
10
T15139601
z612
9/20/18
11
T15139602
zcj3a
9/20/18
12
T15139603
zc14
9/20/18
13
T15139604
zej5c
9/20/18
14
T15139605
zhj9
9/20/18
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc. under my direct supervision
based on the parameters provided by East Coast Truss.
Truss Design Engineer's Name: Velez, Joaquin
My license renewal date for the state of Florida is February 28, 2019.
Florida COA:6634
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the jurisdiction(s) identified and that the
designs comply with ANSI[TPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for 'MiTek
customers file reference purpose only, and was not taken into account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verify applicability of design parameters and properly incorporate these designs
into the overall building design per ANSIfrPI 1, Chapter 2.
1 of 1
,,11(111111111�1�
QU I N V F<
ON ' ........ Fly'.,
No 68182
;4:
STATE OF.
'4ss/0 N AL E� ;%%%�
11111111.10
Joaquin Velez PE N6.68182
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610 §eptgnbpr 20,2018
—note,
Velez J in
pk j'n
j Client: Anthony Odeh
S0 L I O STA RTeProject:
Date: 9/20/2018
Designer: Steve
Page 1 of 6
DESIGN SOFTWARE Address:
Job Name: Odeh Residence
Project #: J36756
LVL1 LP-LVL 2900Fb-2.OE 1.750" X 11.250"
2-Ply - PASSED
Level: Level
III(II
IILI(I
ILIIIIIII
II
(IIIIIIIILILII
I(I((II
(•(ILIL
IIIII:
IIII(I
I(L(IIILLI((I
.III
III
II
I
IIL
(I
(13
�14)
111/4e
1 SPF 2 SPF
3 SPF
6'1"
19,11"
' 3 1/2"
26'
Member Information
Reactions PATTERNED Ib (Uplift)
Type: Girder
Application: Floor
Brg Live Dead Snow Wind Const
Plies: 2
Design Method: ASD
1 60 (-118) (-633)
0 0 303 (-716)
Moisture Condition: Dry
Building Code: IBC/IRC 2015
2 419 3748
0 0 2384
Deflection LL: 240
Load Sharing: No
3 165 1440
0 0 918 (-5)
Deflection TL: 180
Deck: Not Checked
Importance: Normal
Temperature: Temp — 100eF
Bearings
General Load
Floor Live: 20 PSF
Bearing Length Cap. React D/L lb
Total Ld. Case Ld. Comb.
Dead: 15 PSF
1 _ SPF 3.500" 0% -675 / -741
-1416 _L D+C
Wind: 180 PSF
2 - SPF 4.500" 93% 3803 / 2418
3 - SPF 3.500" 45% 1428 / 910
(-1416)
6221 LL D+C
2338 —L D+C
Analysis Results
Analysis Actual Location Allowed Capacity Comb.
Case
Neg Moment -11400 ft-lb 6' 1" 22463 ft-lb 0.508 (51 %) D+C
LL
Pos Moment 9271 ft-lb I 22463ft-lb 0.413 (41%) D+C
_L
Shear 3504lb T 1/4" 9352 lb 0.375 (37%) D+C
LL
LL Defl inch 0.279 (U846) 16'9 15116" 0.984 (U240) 0.280 (28%) C
L
TL Defl inch 0.710 (U333) 16-10 1/4" 1.312 (U180) 0.540 (54%) D+C
L
Design Notes
1 Provide restraint at supports to ensure lateral stability.
2 Dead Load Deflection: Instant = 0.431", Long Term = 0.646"
3 Fasten all plies using 2 rows of 10d Box nails (.128x3") at 12" o.c. Maximum end distance not
to exceed 6".
4 Refer to last page of calculations for fasteners required for specked loads.
5 Girders are designed to be supported on the bottom edge only.
6 Top loads must be supported equally by all plies.
7 Tie -down connection required at bearing 1 for uplift 1416 Ill (Combination D+C, Load Case
8 Top must be laterally braced at a maximum of 9' 3/4" o.c.
9 Bottom must be laterally braced at a maximum of 6'11" o.c.
10 Lateral slenderness ratio based on single ply width.
ID Load Type Location Trib Width Side
Dead 0.9 Live 1 Snow 1.15 Wind 1.6 Const. 1.25 Comments
1 Uniform 1-0-0 Top
25 PSF 20 PSF 0 PSF 0 PSF
0 PSF
2 Point 1-0-0 Top
274lb 0lb 0lb 0lb
219Ib ZCJ1B
Bearing Length 0-3-0
Continued on page 2...
Notes
Manufacturer Info
East Coast Truss
Louisiana-Pacific Corp
This component analysis Is based on the loads,
geometry and other conditions as entered by the user
and listed In this report The user Is responsible to
414 Union Street, Suite 2000
ensure the accuracy of the Input and the applicability to
,he actual conditions of the structure for which this
Nashville, TN 37219
(888) 820-0325
component is intended This analysis is valid only for the
product listed
www.lpcorp.com
Copyright 2016 All rights reserved by Louisiana Pacific
Corp. 414 Union at Suite 2000, Nashville, TN 37219
This design is valid until
APA: PR-L280, ICGES: ESR-2403,
L+DBS: RR-25783, Florida: FL15228
10/31/2020
LP SolidStart Design Version 3.1.04 (Build 18.11.115) Powered by i5tructTM
Client:Date:
S.0 L ID START"""':
IN
9/20/2018
Designer: Steve
Page 2 of 6
Address:
Job Name: Odeh Residence
oESIGN soFTWARE
Project M J36756
LVL1 LP-LVL 290OFb-2.OE 1.750" X 11.250" 2-Ply - PASSED
Level: Level
II
1111111111111.111111
I111
11111I1
II
11111111111111II
F1111T11111
III
I1111111111111
\/ i \/
�J ( 0 L/ T
�.0 11� �2� 3�
�4
.0
1/4
1 SPF 2 SPF
3 SPF
6'1"
19,111,
' 3 1/2"
26'
Continued from page 1
ID Load Type
Location Trib Width
Side
Dead 0.9
Live 1 Snow 1.15 Wind 1.6 Const. 1.25 Comments
3 Point
34-0
Top
219lb
0lb 0lb 0lb
175lb ZCJ2
Bearing Length
0-3-0
4 Point
5-M
Top
250111
0lb 0lb 0lb
200lb ZCJ3A
Bearing Length
0-3-0
5 Point
7-0-0
Top
2961b
0lb 0lb 0lb
236 lb ZEJ5C
Bearing Length
0-3-0
6 Point
9-0-0
Top
296lb
0lb 0lb 0lb
236 lb ZEJSC
Bearing Length
0-3-0
7 Point
11-0-0
Top
296lb
0lb 0lb 0lb
236 lb ZEJSC
Bearing Length
0-3-0
8 Point
13-0-0
Top
296lb
0lb 0lb 0lb
236 lb ZEJSC
Bearing Length
0-3-0
9 Point
15-M
Top
296lb
0lb 0lb 0lb
236 lb ZEJSC
Bearing Length
0-3-0
10 Point
17-0-0
Top
296lb
0lb 0lb 0lb
236 lb ZEJSC
Bearing Length
0-3-0
11 Point
19-0-0
Top
296111
0lb 0lb 0lb
236 lb ZEJ5C
Bearing Length
0-3-0
12 Point
21-0-0
'Top
250lb
0lb 0lb 0lb
200lb ZCJ3A
Bearing Length
0-3-0
13 Point
23-0-0
Top
274lb
0lb 0lb 0lb
219lb ZCJ2
Bearing Length
0-3-0
14 Point
25-0-0
Top
274lb
0lb 0lb Olb
219lb ZCJ1B
Bearing Length
0-3-0
Self Weight
11 PLF
Notes
Manufacturer Info
East Coast Truss
Louisiana-Pacific Corp
This component analysis is based on the loads,
geometry and other conditions as entered by the user
and listed In this report The user is responsible to
414 Union Street, Suite 2000
ensure the accuracy of the Input and the appricabiuty to
Nashville, TN 37219
the actual conditions of the structure for which this
(888) 820-0325
component is intended. This analysis is valid only for the -
www.lpcorp.com
product listed.
Copyright 2016 All rights reserved by Louisiana Pacific
-
APA: PR-1_280, ]CC -ES: ESR-2403,
LADBS: RR-25783, Florida: FL15228
Corp. 414 Union St Suite 2000, Nashville, TN 37219
This design is valid until
10/31/2020
LP SolidStart Design Version 3.1.04 (Build 18.11.115) Powered by i5tructTM
Client: Anthony Odeh
91 a� S.Q L I D STA RT°Project:
91
Date: 9/2012018
Designer: Steve
Page 3 of 6
Address:
Job Name:
Odeh Residence
DESIGN SOFTWARE
Project#:
J36756
LVL1 LP-LVL 290OFb-2.OE 1.750" X 11.250"
2-Ply - PASSED
Level: Level
CV
1 SPF 2 SPF
3 SPF
6'1"
43
19,11"
1/2"
26'
Multi -Ply Analysis
Fasten all plies using 2 rows of 10d. Box nails (.128x3") at 12" o.c.. Maximum
end distance not
to exceed 6"
Capacity 0.0 %
Load 0.0 PLF
leld Limit per Foot 181.1 PLF
Ield Limit per Fastener 90.5lb.
leld Mode IV
Edge Distance 1 1/2"
Min. End Distance 3"
Load Combination
Duration Factor 1.00
I
Notes
Manufacturer Info
East Coast Truss
Louisiana-Pacific Corp
This component analysis is based on the loads,
geometry and other conditions as entered by the user
. and listed in this report The user is responsible to
414 Union Street, Suite 2000
ensure the accuracy of the input and the applicability tb
Nashville, TN 37219
the actual conditions of the structure, for which this
(888) 820-0325
component is Intended. This analysis is valid only for the
www.lpcorp.com
product Copyright 201
Copyright 2016 All fights reserved by Louisiana Pacfic
APA: PR-L280, ICC-ES: ESR-2403,
Corp. 414 Onion St suite 2000, Nashville, TN 37219
This design is valid until
LADBS: RR-25783, Florida: FL15228
10/31 /2020
LP SolidStart Design Version 3.1.04 (Build 18.11.115) Powered by iStructTM
Client: Anthony Ocleh Date: 9/2012018 Page 4 of 6
SOLIOSTART'Proje"': Designer. Steve
Address: Job Name: Odeh Residence
DESIGNsoicrWARE
Project #: J36756
LVL2 LP-LVL 290OFb-2.OE 1.750" X 11.250" 2-Ply PASSED
Level: Level�
d���G����9'21l�ill�8II�I���11 Ipl I1 IIIIIII����II�0�14
in
11 1/4'
I SPF 2 SPF
TT' 21 H31/2"
7-3"
Member Information Reactions PATTERNED lb (Uplift)
Type: Girder
Application: Floor
Brg Live Dead Snow Wind Const
Plies: 2
Design Method: ASD
1 73 927 0 0 636
Moisture Condition: Dry
Building Code: IBCIIRC 2015
2 73 1274 0 a 914
Deflection LL: , 240
Load Sharing: No
Deflection TL: ISO
Deck: Not Checked
Importance: Normal
Temperature: Temp <= 100*17
Bearings
General Load
Bearing Length Cap. React D/L lb Total Ld. Case Ld. Comb.
Floor Live: 20 PSF
Dead: 15PSF
I - SPF 3.500" 30% 927/636 1564 L D+C
Wind: 180 PSF
2 - SPF 3.500" 42% 1274/914 2188 L D+C
Analysis Results
Analysis Actual Location Allowed Capacity Comb. Case
Moment 4331 ft-lb 5' 22463 ft-lb 0.193(19%) D+C L
Shear 21461b 6'1" 9352 lb 0.229(23%) D+C L
LL Defi inch 0.021 (U3947) 4- 1/2" 0.340 (U240) 0.060(6%) C L
TL Defi inch 0.049 (L/1659) 4-1/8" 0.453 (L/180) 0.110(11%) D+C L
Design Notes
1 Provide restraint at supports to ensure lateral stability.
2 Dead Load Deflection: Instant = 0.028", Long Term = 0.043"
3 Fasten all plies using 2 rows of 10d Box nails (.128x3") at 12" o.c. Maximum end distance not
to exceed 6".
4 Refer to last page of calculations for fasteners required for specified loads.
5 Girders are designed to be supported an the bottom edge only.
6 Top loads must be supported equally by all plies.
7 Top braced at bearings.
8 Bottom braced at bearings.
9 Lateral slenderness ratio based an single ply width.
ID Load Type Location Trib Width Side Dead 0.9 Live 1 Snow 1.15 Wind 1.6 Const. 1.25 Comments
1 Uniform 1-0-0 Top 25 PSF 20 PSF 0 PSF 0 PSF 0 PSF
2 Point 1-0-0 Top 2371b 0 lb 0 lb 0 lb 189 lb ZCJ1 A
Bearing Length 0-3-0
3 Point 3-0-0 Top 2701b 0 lb 0 lb 0 lb 216 lb ZCJ4
Bearing Length 0-3-0
Continued on page 2...
Notes
Manufacturer Info
East Coast Truss
Louisiana-Pacific Corp
This component analysis Is based on the loads,
geometry and other conditions as entered by the user
414 Union Street, Suite 2000
and listed In this report. The user is responsible to
ensure the accuracy of the input and the applicability to
Nashville, TN 37219
.e actual conditions of the structure for which this
(888) 820-0325
component isntended. This analysis is valid only for the
www.lpcorp.com
product fisted.
APA: PR-1-280, [CC -ES: ESR-2403,
Copyright 2016 Ali rights reserved by Louisiana Pacific
Corp. 414 Union St Suite 2000, Nashville, TN 37219 This design is valid until
LADES: RR-25783, Florida: FL15228
10/31/2020
LP SolidStart Design Version 3.1.04 (Build 18.11.115) Powered by iStruct-
Client:
alSOLIOSTART°Project:
Anthony Odeh Date: 9/20/2018
Designer: Steve
Page 5 of 6
Address:
Job Name:
Odeh Residence
DESIGN SOFTWARE
Project #:
J36756
LVL2 LP-LVL 2900Fb-2.OE 1.750" X 11.250" 2-Ply - PASSED
Level: Level
II IIII IIIa2:1111l1111111111111I3e1lIIk1111111111111114a
lllll1111111I11 I1111!
11 1 /4"
1 SPF
2 SPF
TY
H3 1/2"
7r3"
Continued from page 1
ID Load Type Location
Trib Width Side Dead 0.9 Live 1 Snow 1.15 Wind 1.6 Const. 1.25 Comments'
4 Point 5-0-0
Top 14321b 0lb
0lb 0lb 11451b
E01G
Bearing Length 0-3-0
Self Weight
11 PLF
1
Notes
Manufacturer Info
East Coast Truss
Louisiana-Pacific Corp
This component analysis is based on the loads,
geometry and other conditions as entered by the user
414 Union Street, Suite 2000
and listed in this report. The user is responsible to
ensure the accuracy of the input and the applicability to
Nashville, TN 37219
the actual conditions of the structure for which this
(888) 820-0325
component is Intended. This analysis is valid only for the
www.lpcorp.com
produc[listed
APA: PR-L280, ICC-ES: ESR-2403,
Copyright 2018 All fights reserved by Louisiana Pedfic
Corp. 414 Union St Suite 2000, Nashville, TN37219
This design is valid until
LADES: RR-25783, Florida: FL15228
10/31/2020
LP SolidStart Design Version 3.1.04 (Build 18.11.115) Powered by iStruct-
Client: Anthony Odeh
�„ SOLIOSTART°Project:
Date: 9/20/2018
Designer: Steve
Page 6 of 6
-- Address:
Job Name:
Odeh Residence
DESIGN SOFTWARE
Project #:
J36756
LVL2 LP-LVL 290OFb-2.OE 1.750" X 11.250"
2-Ply - PASSED
Level: Level
r
11 114"
1 SPF
77'
2 SPF
H3 1/2"
7'3"
Multi -Ply Analysis
Fasten all plies using 2 rows of 10d Box nails (.1280") at 12" o.c.. Maximum end distance not
to exceed 6"
Capacity 0.0 %
Load 0.0 PLF
Yield Limit per Foot 181.1 PLF
laid Limit per Fastener 90.5 lb.
Yield Mode IV
Edge Distance 1 1/2"
Min. End Distance 3"
Load Combination
Duration Factor 1.00
Notes
Manufacturer Info
East Coast Truss
Louisiana-Pacific Corp
This component analysis is based on the loads,
geometry and other conditions as entered by the user
414 Union Street, Suite 2000
and listed in this report. The user Is responsible to
ensure the accuracy of the Input and the applicability to
Nashville, TN 37219
the actual conditions of the structure for which this
(888) 820-0325
component is Intended. This analysis Is valid only for the
www.lpcorp.com
productliCopyright 201 All fights reserved by Louisiana PeMie
Copyright
.APA: PR-L280, ICC-ES: ESR-2403,
Union
Corp. 414 Union St Suite 2000; Nashville, TN 37279
This design is Valid Until '
LADBS: RR-25783, Florida: FL15228
10/31/2020
LP SolidStart Design Version 3.1.04 (Build 18.11.115) Powered by iStructTM
Job
Truss
Truss Type
Qty
Ply
Odeh Residence
T15139592
J36756
E01G
Common Girder
1
Job Reference o tional
East Coast Truss, Ft. Pierce, FL 34946 6.22U a May 24 ZU16 MI I eKmausmes, Inc. I nu Sep ZU 1 Z:46:11 ZU1 U Page 1
I D:jxrRd W Yj5kOSOdeYh7gdBycnS U-cUrWuvrrBOc5oM6V6dXgOgBidb6tkSDm p51 GyUybklY
2-M 9-M 11-0-0 13-0-0 15-0-0 17-0-0 26-0-0 28 2'0
2-0-0 9.0-0 210 2-0-0 2-M 2-0-0 9-0-0 2-0-0
Scale = 1:50.0
TOP CHORD MUST BE BRACED BY END JACKS,
4x4 —_ ROOF DIAPHRAGM, OR PROPERLY CONNECTED
PURLINS AS SPECIFIED.
3x4 = 1x4 II 3x8 = 3x4 = 3x4 =
7-1 6 13-0-0 18-10-10
26-0-0
7-1.6 5-10-10 5-10-10
7-1-6
Plate Offsets (X.Y)—
13:0-5-2.0-1-121.1`14:0-5-2.0-1-121
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Udefl Ltd
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.57
Vert(LL) 0.17 19-20 >999 240
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.62
Vert(CT) -0.23 19-20 >999 180
BCLL 0.0 '
Rep Stress Incr NO
WB 0.21
Horz(CT) 0.08 15 n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -MS
Weight: 289 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied
or 7-8-7 oc bracing.
WEBS 2x4 SP No.3 JOINTS 1 Brace at Jt(s): 9, 7, 11
REACTIONS. (lb/size) 2=185410-3-8, 15=1854/0-3-8
Max Horz 2=73(LC 4)
Max Uplift 2=1826(LC 4), 15=1826(LC 5)
Max Grav 2=2571(LC 20), 15=2571(LC 19)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=5330/3146, 3-4=2353/1449, 4-6=2297/1460, 6-8=2302/1522, 8-10=2302/1521,
10-12=2298/1460, 12-14=2353/1449, 14-15=-5330/3146, 3-5=2001/1184,
5-7=2006/1189, 7-9=-2006/1189, 9-1 1=2006/1189,11-13=2006/1189,
13-14=2001/1185
BOT CHORD 2-20=2607/4799, 19-20=-2570/4722, 17-19=2642/4745, 15-17=2679/4823
WEBS 3-20=393/853, 14-17=393/853, 8-9=-855/1438, 9-19=597/1184, 3-19=857/664,
14-19=857/663
,
OTPIy "x3")
oU I N �
truss to be connected together with 10d (0.131 nails as follows:
.oO
.........
♦♦ pP <F ���
Top chords connected as follows: 2x4 -1 row at 0-9-0 oc.
♦♦ , E N * �
Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc.
�♦ .' �, `SF•'.•
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
i
2) All loads are considered equally applied to all plies, except If noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
No 6 818 2
•;
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
* ;•
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vuit=180mph (3-second gust) Vasd=139mpti; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; Cat. 11; Exp D; Encl.,
•�
V
GCpi=0.18; C-C Exterior(2)-2-0-11 to 0-7-13, Interior(1) 0-7-13 to 13-0-0, Exterior(2) 13-0-0 to 16-0-0, Interior(1) 16-0-0 to 28-0-11;
F
cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
5) Provide drainage to
••, �`
adequate prevent water ponding.
i�'� O P ,� \� ♦♦♦
,� 1
O
6) Plates checked for a plus or minus 0 degree rotation about its center.
7) This truss has been designed fora 10.0 bottom chord live load nonconcument with any other live loads.
. • R
ss • • • •'' • �� �♦
psf
.1
��,,
8) Thislive lad of 20.Opsfon the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
�O N A�
w Iit between the bottom chord and omembers
0,*
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Gt=lb)
Joaquin Velez PE No.68182
2=1826, 15=1826.
MiTek USA, Inc. FL Cert 6634
10) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
6904 Parke East Blvd. Tampa I'L 33610
Date:
September 20,2018
AWARN/NG - V.Hfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 111I1•7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, note
a truss system. Before use, the building designer must verity the applicability of design parameters and property Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
M iT@k'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke Fast Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty Ply
Residence
T15139592
J36756
E01G
Common Girder
1 n
L
�Odeh
Job Reference o tional
East Coast Truss, Ft. Pierce, FL 34946
8.220 s May24 2018 MiTek Industries, Inc. Thu Sep 20 12:48:11 2018 Page 2
I D.j)TRd W Yj5kOSOcleYh7gdBycnS U-cUrWuvf rBOc5 oM6V6dXgOg8idb6tkS Dmp51 GyUybklY
NOTES-
11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 332 lb down and 265 lb up at 7-4-14, and 332 lb down and 265 lb up
at 18-7-2 on top chord, and 639 Ib down and 458 lb up at 7-0-10, 87 lb down and 28 lb up at 9-1-6, 87 lb down and 28 lb up at 11-1-6, 87 lb down and 28 lb up at
13-0-0, 87 lb down and 28 lb up at 14-10-10, and 87 lb down and 28 lb up at 16-10-10, and 639 lb down and 458 lb up at 18-10-10 on bottom chord. The
design/selection of such connection device(s) is the responsibility of others.
12) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
LOAD CASE(S) Standard
1) Dead + Roof Live.(balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=70, 3-8=-70, 8-14=70, 14-16=70, 21-24=20
Concentrated Loads (lb)
Vert: 3=-73(F) 20=-361(F) 17=-361(F) 19=-42(F) 14=73(F) 29=-42(F) 30=-42(F) 31=42(F) 32=-42(F)
,&WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED M/7EK REFERENCE PAGE Mll-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
�^
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiT@k'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPI1.Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Residence
T15139593
J36756
V7
Valley
1
1
�Odeh
Job Reference (optional)
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Thu Sep 20 12:48:15 2018 Page 1
ID:jxrRdWYj5kOSOcleYh7gdBycnSU-VG41 kHi_Fd7XG_QGLSbcZWJQnDaOgJaLkjGT5FybklU
3-M 6-6-13
3-M 3-3-6
2x3 i
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.44
TCDL
15.0
Lumber DOL
1.25
BC 0.13
BCLL
0.0 '
Rep Stress Incr
YES
WB 0.06
BCDL
10.0
Code FBC2017rrP12014
Matrix-P
LUMBER -
TOP CHORD
2x4 SP No.3
BOT CHORD
2x4 SP No.3
OTHERS
2x4 SP No.3
REACTIONS.
(lb/size) 1=130/6-6-13, 3=130/6-6-13, 4=235/6-6-13
Max Uplift 1=168(1_C 4), 3=168(LC 4), 4=166(LC 4)
Max Grav 1=237(LC 9), 3=237(LC 9), 4=359(LC 9)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-4=-290/207
3x4 =
2x3
DEFL. in (loc) Udefl Ud
Vert(LL) n/a n/a 999
Vert(CT) n/a n/a 999
Horz(CT) 0.00 3 n/a n/a
Scale = 1:14.4
PLATES GRIP
MT20 244/190
Weight: 21 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied orb-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust) Vasd=139mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; Cat. II; Exp D; Encl.,
GCpi=0.18; C-C Exterior(2); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will rd between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb)
1=168, 3=168, 4=166.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
try
J . LENS•
�\ F • ��
No 68182
�:• S OF �/�
R,OP N1,1
�,�5'`S�OfV A ;
11111
Joaquin Velez PE No.68182
MiTek USA,.Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 20,2018
AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev. 1010312015 BEFORE USE.
°
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated is to prevent bucking of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfTPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa,FL 36610
Job
Truss
Truss Type
City
Ply
Odeh Residence
T15139594
J36756
V9
Valley
1
1
Job Reference (optional)
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Thu Sep 20 12:48:15 2018 Page 1
ID:jxrRd WYj5kOSOcleYh7gd8ycnSU-VG41 kHi_Fd7XG_QGLSbcZWJM2DYfgl7LkjGT5FybklU
4-8-9 9-5-1
4-8-9 4-8-9
44 = Scale = 1:19.3
4
2x4 i 1x4 II 2x4
9-5-1
9-&1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/deli L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.67
Vert(LL)
n/a n/a 999
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.31
Vert(CT)
n/a n/a 999
BCLL 0.0
Rep Stress incr YES
WB 0.09
Horz(CT),
0.00 3 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix-S
Weight: 32 lb FT = 0%
LUMBER-
BRACING-
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 1=178/9-5-1, 3=178/9-5-1, 4=396/9-5-1'
Max Uplift 1=198(LC 4), 3=-198(LC 5), 4=296(1_C 5)
Max Grav 1=311(LC 9), 3=311(LC 9), 4=626(LC 9)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-4=-467/305
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust) Vasd=139mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; Cat. II; Exp D; Encl.,
GCpi=0.18; C-C Exterior(2) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 4-8-9, Exterior(2) 4-8-9 to 778-9, Interior(1) 7-8-9 to 8-10-10; cantilever
left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) As requested, plates have not been designed'to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent•with any other live loads.
7) ' This truss has been designed for a live load of 20:00sf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will rd between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=198, 3=198, 4=296.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
F �
GENE.
No 68182
�-0• .XZ
OF : 41
It
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33010
Date:
September 20,2018
AWARNING - Verlry design parametea and READ NOTES ON THIS AND INCLUDED M/TEK REFERENCE PAGE M11.7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
�-
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
'required
MiTek`
Is always for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
Residence
T15139595
J36756
V12
Valley
1
1
�Ocleh
Job Reference o floral
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Thu Sep 2012:48:12 2018 Page 1
ID:jxrRdWYj5kOSOdeYh7gd8ycnSU-4hPu5Fg5yikyPWhhgK2vxuhvk?ZHTxsv211 pVwybklX
6-1-11 6-1-11
44 =
Scale = 1:23.2
8 7 6
3x4 i 1x4 II tx4 II 1x4 II 3x4 'Z�
LOADING (psf)
SPACING-
2-0-0
CS1.
DEFL.
in (loc)
Udefl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.42
Vert(LL)
n/a
n/a
999
TCDL 15.0
Lumber DOL
1.25
BC 0.16
Vert(CT)
n/a
n/a
999
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.12
Horz(CT)
0.00 5
n/a
n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix-S
PLATES GRIP
MT20 244/190
Weight: 47 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 12-3-6.
(lb) - Max Uplift All uplift 100 lb or less atjoint(s) 7 except 1=100(LC 4), 5=100(LC 5), 6=398(LC 4), 8=398(LC 5)
Max Grav All reactions 250 lb or less atjoint(s) 1, 5, 7 except 6=626(LC 6), 8=626(LC 6)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when showm.
WEBS ' 4-6=526/418, 2-8=526/418
NOTES-
1) Unbalanced roof live loads have been considered for this design:
2) Wind: ASCE 7-10; Vult=180mph (3-second gust) Vasd=139mph; TCDL=9:0psf; BCDL=6.Opsf; h=18ft; Cat. II; Exp D; Encl.,
GCpi=0.18; C-C Exterior(2) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 6-1-11, Exterior(2) 6-1-11 to 9-1-11, Interior(1) 9-1-11 to 11-8-14;
cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
4) Plates checked for a plus or minus O'degree rotation about its center.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7 except Qt=lb)
1=100, 5=100, 6=398, 8=398.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
���
`01011111/l"1
,�PQU 1N
No 68182
O: ST OF,
i 040,
nnl
Joaquin Velez PE No.68182
Mink USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 20,2018
A WARNING - Vedty design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1010312015 BEFORE USE.
Design valid for use only with Mrek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, note
a truss system. Before use, the building designer must verily the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
I always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing oftrusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandda, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Residence
�Odeh
T15139596
J36756
V15
Valley
1
1
Job Reference (optional)
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Thu Sep 2012:48:13 2018 Page 1
ID:jxrRdVvYj5kOSOcleYh7gdBycnSU-YtzGJbhNOtpl gGuE2Z8T5D2wPvACNx2HPnN1 MybklW
7-6-13 15-1-10 \
7-6-13 7-6-13
0
16
4
4x4 =
3x4 i ° r ° 3x4
1x4 11 1x4 11 1x4 11
Scale = 1:27.7
LOADING (pso
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.52
Vert(LL) n/a
- n/a 999
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.18
Vert(CT) n/a
- n/a 999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.14
Horz(CT) 0.00
5 n/a n/a
BCDL 10.0
Code FBC20171TP12014
Matrix-S
Weight: 58 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or oc pudins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 15-1-10.
(lb) - Max Uplift All uplift 100 lb or less atjoint(s) 1, 5 except 6=420(LC 5), 8=-420(LC 4)
Max Grav All reactions 250 lb or less at joints) 1, 5 except 7=268(LC 9), 6=705(LC 9). 8=705(LC 9)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-256/249, 3-4=256/249
WEBS 4-6=-608/454, 2-8=608/454
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vu@=180mph (3-second gust) Vasd=139mph; TCDL=9.Opsf; BCDL=6.Opsf; h=1Bft; Cat. 11; Exp D; Encl.,
GCpi=0.18; C-C Exterior(2) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 7-6-13, Exterior(2) 7-6-13 to 10-6-13, Interior(l) 10-6-13 to 14-7-3;
cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) Gable bottom bearing.
%%% QU�N
requires continuous chord
6)
• ���
This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for live load 20.Opsf the bottom in 3-6-0 by 2-0-0
•
C E N
' � SF••.• ��
a of on chord all areas where a rectangle tall wide
:
will rd between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except Gt=lb)
6=420, 8=420.
No 68182 S
* �•
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
�: S OFdo �/
Ec*%%.
Joaquin Velez PE N0.68182
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 20,2018
AWARNING • Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111•7473 rev. 1010312015 BEFORE USE.
Design valid for use only with Mrek® connectors. This design Is based only upon parameters shown, and is for an individual building component,, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, DSB-99 and SCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Odeh Residence
T15139597
J36756
V18
Valley
1
1
Job Reference o tional
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MTek Industries, Inc. Thu Sep 20 12:48:13 2018 Page 1
ID:jxrRdWYj5kOSOGeYh7gd8ycnSU-YtzGJbhkjOtpl gGuE2Z8T5D_fPtACNP2HPnN1 MybklW
8-11-15 17-11-15
8-11-15 8-11-15
4x6 11
Scale=1:33.1
3x4 G 8 7 F 3x4
1x4 11 1x4 11 1x4 11
17-11-15
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
Udefl
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.80
Vert(LL)
n/a
n/a
999
TCDL 15.0
Lumber DOL
1.25
BC 0.31
Vert(CT)
n/a
n/a
999
BCLL 0.0 '
Rep Stress Incr
YES
WB 0.17
Hore(CT)
0.00 5
n/a
n/a
BCDL 10.0
Code FBC2017rrPI2014
Matrix-S
PLATES GRIP
MT20 2441190
Weight: 68 lb FT = O%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 17-11-15.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7 except 6=-481(LC 5), 8=481(LC 4)
Max Grav All reactions 250 lb or less at joints) 1, 5 except 7=464(LC 9), 6=840(LC 9), 8=840(LC 9)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=302/280, 3-4=302/280
WEBS 3.7=-363/114, 4-6=738/527, 2-8=-738/527
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust) Vasd=139mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; Cat. 11; Exp D; Encl.,
GCpi=0.18; C-C Exterior(2) 0-6-8 to 3-6-8, Interior(1) 3-6-8 to 8-11-15, Exterior(2) 8-11-15 to 11-11-15, Interior(1) 11-11-15 to 17-5-7;
cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will rd between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7 except
0=1b) 6=481, 8=481.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
,`�1►1111II/ICI
�.�`�PQu N �F<F �.
.` GE N s .
No 68182
OF Z
to
SS�11 N A`I_
Joaquin Velez PE No.68182
MTTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 20,2018
AWARNING - Vad(y design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERENCE PAGE Mll•7473 rev. 1e/03/2015 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, note
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always requited for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
Odeh Residence
T'15139598
J36756
V21
Valley
1
1
Job Reference o tienal
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Thu Sep 20 12:48:14 2018 Page 1
ID:jxrRdWYj5kOSOcleYh7gd8ycnSU-13XeWxhMUJ?gfgr4ol4NOJmCppE1 xgKCV3 WwZpybklV
10-5-2 105-2
Scale=1:40.6
4x4 =
3x4 i 13 12 11 10 9 8 3x4
1x4 II 1x4 II 1x4 II 1x4 II 3x4 =
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft L/d
PLATESGRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.58
Vert(LL) n/a - n/a 999
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.20
Vert(CT) n/a - n/a 999
BCL' L 0.0
Rep Stress Incr YES
WB 0.19
Horz(CT) 0.60 7 n/a n/a
BCDL 10.0
Code FBC2017ITP12014
Matrix-S
Weight: 91 lb FT = 0%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 20-10-3.
(lb) - Max Uplift All uplift 100 lb or less at joint(s) 1, 7, 11 except 8=-421(LC 5), 10=345(LC 4). 13=421(LC 4),
12=-345(LC 5)
Max Grav All reactions 250 lb or less at joints) 1, 7, 11 except 8=721(LC 6), 10=610(LC 9), 13=721(LC 6),
12=610(LC 9)
FORCES. (lb) - Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 3-4=-361/358, 4-5=361/358
WEBS 6-8=-622/456, 5-10=514/390, 2-13=622/456, 3-12=514/390
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=180mph (3-second gust) Vasd=139mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; Cat. 11; Exp D; Encl.,
GCpi=0.18; C-C Exterior(2) 0-6-810 3=6-8, Interion1l) 3-6-8 to 10-5-2, Exterior(2) 10-5-2 to 13=5-2,'lnterior(1) 13-5-2 to 20-3-12;
cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60
3) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
4) Plates checked for a plus or minus 0 degree rotation about its center.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
-7) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any othermembers, with BCDL = 10.Opsf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 7, 11 except
at=lb) 8=421, 10=345, 13=421, 12=345.
9) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
,�.� PCIU IN V �.
10
No 68182
� t S OF :41
.4*0F
Joaquin Velez PE No.68182
Mrrek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 20,2018
�r
AWARNING. Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11111-7473 rev. 10/03/2015 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only,upon parameters shown, and Is for an individual building component, not .��•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see . ANSUTPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa,FL 36610
Job
Truss
Truss Type
Qty
Ply
Odeh Residence
'
T15139599
J36756
ZCJ1A
Jack -Open
2
1
Job Reference (optional)
East Coast Truss, Ft. Pierce, FL 34946 a.zzu s may z4 zula mi I eK mausmes, inc. I nu ziep zu i z:4a: i o zu i o rage i
ID:jxrRd WY5kOSDcleYh7gd8ycnSU-zSePxdjcOxFOuB?TvA6r5krWmcuHPmnVzN?l ehybklT
-2-M 1-4-9
2-0-0 1-4-9
Scale = 1:9.0
1-4-9
Plate Offsets (X.Y)-
r2:0-0-2.0-0-01
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.74
Vert(LL) -0.00
7 >999 240
MT20 244/190
TCDL 15.0
Lumber DOL - 1.25
BC 0.28
Vert(CT) 0.00
7 >999 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00
4 n/a n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MP
Weight: 8 lb FT = O%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 1-4-9 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=13/Mechanical, 2=314/0-3.8, 4=34/Mechanical
Max Horz 2=244(LC 4)
Max Uplift 3=13(1_C 1), 2=-763(LC 4), 4=-48(LC 10)
Max Grav 3=102(LC 4), 2=426(LC 10). 4=153(LC 4)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vuft=180mph (3-second gust) Vasd=139mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; Cat. II; Exp D; Encl.,
GCpi=0.18; C-C Extedor(2)-2-0-11 to 0-7-13, Interior(1) 0-7-13 to 1-4-7; cantilever left and right exposed ; Lumber DOL=1.60 plate
grip, DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
` t,�
will fit" between the bottom chord and any other members.
,,� •
6) Refer to girder(s) for truss to truss connections.
7) Provide bearing
,�, , Ci E N • •
S�•:•
mechanical connection (by others) of truss to plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except (jt=lb)
2=763.
8) Wanting: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
�� .•• �,�
i
No 68182
: 3 ' S OF : 44/:
'.
10 <v
.00..
0�,,n.�•
O R,�P.��=��•
%�
s,o N Ali- E�G
nn11,1.
Joaquin Velez PE No.68182
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd, Tampa FL 33610
Date:
September 20,2018
e WARNING - Venfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 10103/2015 BEFORE USE.
Design valid for use only with Meek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not•
a truss system. Before use, the building designer must verify the applicability, of design parameters and property incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent. bracing
MiTek°
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP11 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, V8 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
Odeh Residence
T15139600
J36756
ZCA B
Rafter
2
1
Job Reference (optional)
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MiTek Industries, Inc. Thu Sep 2012:48:17 2018 Page 1
ID:jxrRdWYj5kOSOcleYh7gd8ycnSU-ReCnBzkEnENFWHarrte4exOmaOHVBD1 eBOIaA8ybkIS
2-1-0
2-1-0
Scale: 1.5"=1'
2-1-0
0315�
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in
(loc) Udefi L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.42
Vert(LL) -0.00
5 >999 240
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.09
Vert(CT) 0.00
5 >999 180
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00
4 n/a n/a
BCDL 10.0
Code FBC2017frP12014
Matrix -MP
Weight: 5 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.2
TOP CHORD
Structural wood sheathing directly applied or 2-1-0 oc purlins.
BOT CHORD 2x4 SP No.2
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 2=270/0-3-8, 2=270/0-3-8, 4=113/Mechanical
Max Horz 2=195(LC 4)
Max Uplift 2=687(LC 4), 4=219(LC 10)
Max Grav 2=493(LC 10), 2=270(LC 1), 4=399(LC 4)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust) Vasd=139mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; Cat. II; Exp D; Encl.,
GCpi=0.18; C-C Exterior(2); cantilever left and right exposed.; Lumber DOL=1.60 plate grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections. ` u �,N �
7) Solid blocking is required on both sides of the truss at joint(s), 2. ,`� OPQ VF�� I
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) � , •,•; G ENS 0
2=687, 4=219. ; ••.•
9)Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required. i
No 68182
�: S OF :.40�/�
nnr,
Joaquin Velez PENo.68182
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 20,2018
AWARN/NG - Verify design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERENCE PAGE 11111.7473 rev. 10/0312015 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
��•
a truss system. Before use, the building designer must verity the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabdcation, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314.
Tampa, FL 36610
Jab
Truss
Truss Type
W
Ply
Odeh Residence
�ZCJ2
T15139601
J36756
Jack -Open
2
1
Job Reference (optional)
Last toast I cuss, 1-1. Pierce, rL 34946 8.22U s May 24 2U18 MI reK Industnes, Inc. Tnu Sep 20 12.48:17 2U18 Page 1
ID:jxrRd WYj5kOSOcleYh7gd8ycnSU-ReCnBzkEnENFWHafrte4exOi5OFx8D 1 eB01aABybklS
-15-9 2-0-9
15-9 2-0-9
LOADING (psf)
TCLL 20.0
TCDL 15.0
BCLL 0.0
BCDL 10.0
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
SPACING -
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code FBC2017frPl
2-0-9
2-0 0
CSI.
DEFL.
in
(loc)
Vdefl
Ud
1.25
TC 0.70
Vert(LL)
-0.00
7
>999
240
1.25
BC 0.25
Vert(CT)
-0.00
4-7
>999
180
REACTIONS. (lb/size) 3=39/Mechanical, 2=239/0-3-8, 4=9/Mechanical
Max Harz 2=300(LC 4)
Max Uplift 3=81(LC 5), 2=428(LC 4)
Max Grav 3=150(LC 6), 2=394(LC 10), 4=77(LC 6)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
0.00
n/a n/a
Scale = 1:12.4
PLATES GRIP
MT20 244/190
Weight: 9 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 2-0-9 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust) Vasd=139mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; Cat. II; Exp D; Encl.,
GCpi=0.18; C-C Extedor(2) -1-6-7 to 1-5-9, Interior(1) 1-5-9 to 1-11-13; cantilever left and right exposed ; Lumber DOL=1.60 plate
grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom. chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb)
2=428.
8) Waming: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
,`(4 `�111IIIIfit.
.%`' PQU IN
.`, N 'DENS'
No 68182
r
O:. S OF .:��
�O N A %%%%
Intl
Joaquin Velez PE No:68182
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 20,2018
AWARNING- Verl/y design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 10/e3/1015 BEFORE USE.
Design valid for use only with MTek®wnnectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
is always required for stability and to prevent collapse with possible peisonal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUfP11 duality Criteria, DSB-89 and BCSI Building Component
8904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job Truss
Truss Type
Qty
Ply
ResidenceT15139602
J36756 ZCJ3A
Jack -Open
2
1b
Eeh
Reference o tional
East Coast Truss, Ft. Pierce, FL 34946
6.zzu s May z4 zults MI I eK'maustnes, Inc. I nu Jep zU 1z:4u:l t1 zum rage i
ID:jxrRdWYj5kOSOcleYh7gd8ycnSU-vnn9MJIsYYV67R9rl b9JA9xtrQV6tgHnQgU7iaybklR
-1-5-9 3-5-11 i
1-5-9 3-5-11
Scale=1:16.5
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Vdefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.70
Vert(LL) -0.03 4-7 >999 240
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.58
Vert(CT) -0.03 4-7 >999, 180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00 3 n/a n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MP
Weight: 14 lb FT = 0%
LUMBER- BRACING-
TOP'CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 3-5-11 oc purlins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-D-0 oc bracing.
REACTIONS. (lb/size) 3=92/Mechanical, 2=285/0-3-8, 4=38/Mechanical
Max Harz 2=388(LC 4)
Max Uplift 3=188(LC 5), 2=-408(LC 4), 4=11(LC 5)
Max Grav 3=242(LC 6), 2=451(LC 10), 4=94(LC 6)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown:
NOTES-
1) Wind: ASCE 7-10; Vu@=180mph (3-second gust) Vasd=139mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; Cat. II; Exp D; Encl.,
GCpi=0.18; C-C Exterior(2) -1-6-7 to 1-5-9, Interior(1) 1-5-9 to 3-4-15; cantilever left and right exposed ; Lumber DOL=1.60 plate grip
DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will rd between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb)
3=188,2=408.
8)Warning: Additional permanent and stability bracing for truss system (not part of this component design) Is always required.
..........
0
No 68182
OF
Joaquin Velez PE No.68182
Mrrek,OSA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 20,2018
,&WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED M/TEK REFERENCE PAGE MI1-7473 rev. 1010312015 BEFORE USE.
'
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek-
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see . ANSUTPIt Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Infornatlon available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
I
Job
Truss
Truss Type
Qty
Ply
Odeh Residence
T75139603
J36756
ZCJ4
Jack -Open
2
1
Job Reference o tional
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 2018 MTek Industries, Inc. Thu Sep 20 12:48:18 2018 Page 1
ID:jxrRdWYj5kOSOcleYh7gd8ycnSU-vrm9MJIsYYV67R9r1 b9JA9xsGQWxtgHnOgU7iaybklR
�I
LOADING (psf)
TCLL 20.0
TCDL 15.0
BCLL 0.0
BCDL 10.0
LUMBER -
TOP CHORD 2x4 SP No.2
BOT CHORD 2x4 SP No.3
2-0-0 4-23
SPACING-
2-0-0
CSI.
Plate Grip DOL
1.25
TC 0.74
Lumber DOL
1.25
BC 0.52
Rep Stress Incr
YES
WB 0.00
Code FBC2017/TPI2014
Matrix -MP
REACTIONS. (lb/size) 3=108/Mechanical, 2=365/0-3-8, 4=42/Mechanical
Max Horz 2=360(LC 5)
Max Uplift 3=282(LC 5), 2=-623(LC 4), 4=28(LC 5)
Max Grav 3=195(LC 9), 2=486(LC 10), 4=78(LC 6)
FORCES. (lb) -Max. Comp:/Max. Ten. -All forces 250 (lb) or less except when shown.
4-23
DEFL. in (loc) I/deft Ud
Vert(LL) 0.04 4-7 >999 240
Vert(CT) -0.04 4-7 >999 180
Horz(CT) -0.00 3 n/a n/a
Scale=1:14.8
PLATES GRIP
MT20 244/190
Weight: 16 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-2-3 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES- 1
1) Wind: ASCE 7-10; Vu0=180mph (3-second gust) Vasd=139mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; Cat. II; Exp D; Encl.,
GCpi=0.18; C-C Exterior(2)-2-0-11 to 0-7-13, Interior(1) 0-7-13 to 4-1-7; cantilever left and right exposed ; Lumber DOL=1.60 plate
grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricatorto increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except at=lb)
3=282, 2=623.
8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
t1{1111Iiit.,
PQv I N vF�'�',.
E IN
No 68182
-13'. S OF .:��/
"111rinl
Joaquin Velez PE No.68182
Mrrek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 20,2018
AWARNINO - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7477 rev. 10/03M015 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek°
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUiPl1 Quality Criteria, OSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
6904 Parke East Blvd.
Tampa, FL 36610
r Y
Job
Truss
Truss Type
City
Ply
Odeh Residence
T15139604
J36756
ZEJ5C
Jack -Open
7
1
Jab Reference o tional
East Coast Truss, Ft. Pierce, FL 34946
a.2zu s may z4 zuiti ml I eK maustnes, Inc. I nu Smv Sep zu lz:4tzuitr rage 1
ID:jxrRdWYj5kOSOcleYh7gd8ycnSU-N1 KXZflUJsdylbj2algYjMTl lggLc7XxfKEhFOybklQ
-15-9 5-0-0
15-9 5-0-0
Scale = 1:20.9
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL,
in
(loc)
Udefl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.72
Vert(LL)
-0.08
4-7
>711
240
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.64
Vert(CT)
-0.12
4-7
>491
180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT)
0.01
3
n/a
n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MP
Weight: 19 lb FT = O%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD
BOT CHORD 2x4 SP No.2 BOT CHORD
REACTIONS. (lb/size) 3=143/Mechanical, 2=347/0-3-8, 4=62/Mechanical
Max Horz 2=482(LC 4)
Max Uplift 3=291(LC 5), 2=-418(LC 4), 4=25(LC 5)
Max Grav 3=346(LC 6), 2=533(LC 10), 4=120(LC 6)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Structural wood sheathing directly applied or 5-0-0 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10; Vult=180mph (3-second gust) Vasd=139mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; Cat. II; Exp D; Encl.,
GCpi=0.18; C-C Exterior(2) -1-6-7 to 1-5-9, Interior(1) 1-5-9 to 4-11-4; cantilever left and right exposed ; Lumber DOL=1.60 plate grip
DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will rd between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except Qt=lb)
3=291, 2=418.
8) Warning: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
,�411111//j�
POtU IN V ,
No 68182
1Z
9 S OF 4
P
i .. 0 R.I O,. ♦ �.
,
'fS;O N A� 0���
�
Joaquin Velez PE No.68182
MITek USA,.inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
September 20,2018
WARNING - verify design parameters end READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 1010312015 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
,��•
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
M iTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
y
Job
Truss
Truss Type
Qty
Ply
Residence
�Odeh
T15139605
J36756
ZHJ9
Diagonal Hip Girder
2
1
Job Reference o tional
East Coast Truss, Ft. Pierce, FL 34946 8.220 s May 24 ZU18 MiTek Industries, Inc. Thu Sep ZU 12:48:ZU 2016 Page 1
ID:jxrRd W YjSkOSOGeYh7gdBycnS U-rDuwn_m749lpNIIE80BnGaO CVE8JLVz4u_zEnTybklP
-2-6-4 4-5-10 8-6-3
2 6 4 4-5-10 4-0-9
Scale=1:21.7
2x3 11
4 5
0 8
4-5-10
8-6-3
0 8
45-2
4-0-9
Plate Offsets (X.Y)—
f2:Edge.0-1-81, r7:0-2-8.0-2-121
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.76
Vert(LL) -0.11
8-11 >903 240
MT20 244/190
TCDL 15.0
Lumber DOL 1.25
BC 0.79
Vert(CT) -0.11
8-11 >936 180
BCLL 0.0
Rep Stress Incr NO
WB 0.37
Horz(CT) 0.02
7 n/a n/a
BCDL 10.0
Code FBC2017lrP12014
Matrix -MP
Weight: 42 lb FT = O%
LUMBER-
BRACING -
TOP CHORD 2x4 SP 285OF-1.8E
TOP CHORD
Structural wood sheathing directly applied or 5-3-12 oc purlins,
BOT CHORD 2x4 SP No.2
except end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 6-6-3 oc bracing.
REACTIONS. (lb/size) 2=50710-5-0, 7=353/Mechanical
Max Horz 2=723(LC 14)
Max Uplift 2=1424(LC 4). 7=601(LC 5)
Max Grav 2=758(LC 19), 7=636(LC 16)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1502/542, 3-4=303/158, 4-7=205/270
BOT CHORD 2-8=-809/1063, 7-8=809/1063
WEBS 3-8=0/338, 3-7=1151/877
NOTES-
1) Wind: ASCE 7-10; Vuh=180mph (3-second gust) Vasd=139mph; TCDL=9.Opsf; BCDL=6.Opsf; h=18ft; Cat. 11; Exp D; Encl.,
GCpi=0.18; C-C Comer(3) -2-6-4 to 1-8-10,. Ezterior(2) 1-8-10 to 8-6-3; cantilever left and right exposed; Lumber DOL=1.60 plate
grip DOL=1.60
2) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is
the responsibility of the fabricator to increase plate sizes to account for these factors.
3) Plates checked for a plus or minus 0 degree rotation about its center.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=1b)
2=1424,7=601.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 382 III down and 161 lb up at
1-8-6, 278 lb down and 131 lb. up at 3-7-3, and 375 lb down and 312 lb up at 5-1-11, and 347 lb down and 216 lb up at 6-0-11 on
top chord, and 90 lb down and 72 lb up at 1-8-6, 45 lb down and 3 lb up at 3-7-3, and 45 Ib down and 35 lb up at 5-1-11, and 61 lb
down and 21 lb up at 6-0-11 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
9) Wanting: Additional permanent and stability bracing for truss system (not part of this component design) is always required.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=70, 4-5=-30, 6-9=20
I olki111111f#..
.0 PQU I N VFW ��..
% G EN g
No 68182
.0 S OF 41J•
•
•
•
41
11 N A 0*�`��
11111
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6634
6904Parke East Blvd. Tampa FL 33610
Date:
September 20,2018
AwARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 11411-7473 rev. 1010312015 BEFORE USE.
°
Design valid for use only with MiTek® connectors. This design is based only,upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. •Additional temporary and permanent. bracing
MiTek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314.
Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
Odeh Residence
T15139605
J36756
ZHJ9
Diagonal Hip Girder
2
1
Job Reference (optional)
East Coast Truss, Ft Pierce, FL 34946
LOAD CASE(S) Standard
Concentrated Loads (lb)
Vert: 12=55(B) 15=6(F) 16=43(B) 17=3(F) 18=7(B) 19=13(F)
8.220 s May 24 2018 MTek Industries, Inc. Thu Sep 20 12:48:20 2018 Page 2
I D:jxrRd W Yj5kOSOcleYh7gd8ycnSU-rDuwn_m749lpNIIE8OBnGaOCVE8JLVz4u_zEnTybklP
A WARNING • Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M I-7473 rev. 101031201S BEFORE USE.
^
Design valid for use only with MrrekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
WOW
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandra, VA 22314.
Tampa,.FL 36610
1
Symbols
PLATE LOCATION AND ORIENTATION
Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
For 4 x 2 orientation, locate
plates 0- 'lid' from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
Plate location details available in MiTek 20120
software or upon request.
PLATE SIZE
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
BEARING
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
ANSI/TPI1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
Numbering System
6-4-8 dimensions shown in ft-in-sixteenths
(Drawings not to scale)
2 3
TOP CHORDS
0
cr-2 c2-3
c 4
WEBS
O
T �'•�
U
A
D_
O
~
c -e Crcm
BOTTOM CHORDS
8 7 6 5
0
of
O
2
U
IL
O
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
]CC -ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
© 2012 MiTek® All Rights Reserved
MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015
A General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSVTPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or pudins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, If no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
is not sufficient.
20. Design assumes manufacture in accordance with
ANSIrrPI 1 Quality Criteria.