HomeMy WebLinkAboutEnergy Calcs - Herd - REVISEDCalculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2022-Jan-12 11:21:49
Right-Suite® Universal 2021 21.0.11 RSU27054 Page 1
...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Load Short Form Dec 30, 2020Date:House Vicki Lynne NisaBy:
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
Project Information
Herd Residence, Air Conditioning Unlimited, LLCFor:
5194 Tree Top Trail, Port St Lucie, FL 34951
Design Information
InfiltrationClgHtg
Blower doorMethod9041Outside db (°F)
3 (partial) / 1Shielding / stories7570Inside db (°F)
50 Pa / 0 cfmPressure / AVF1529Design TD (°F)
L-Daily range
5030Inside humidity (%)
572Moisture difference (gr/lb)
HEATING EQUIPMENT COOLING EQUIPMENT
Make Make Lennox
Trade Trade LENNOX
Model Cond ML14XC1-041-230A**
AHRI ref Coil CBA27UHE-048-230*++TDR
AHRI ref 10259425
Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER
Heating input kW11.1 Sensible cooling Btuh26950
Heating output Btuh37834 Latent cooling Btuh11550
Temperature rise °F27 Total cooling Btuh38500
Actual air flow cfm1283 Actual air flow cfm1283
Air flow factor cfm/Btuh0.034 Air flow factor cfm/Btuh0.054
Static pressure in H2O0.70 Static pressure in H2O0.70
Space thermostat Load sensible heat ratio 0.71
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft²)(Btuh)(Btuh)(cfm)(cfm)
Bath 2 39 172 96 6 5
Bath 4 80 1603 719 55 39
Bed 2 218 5129 2184 176 117
Bed 3 156 1678 1498 58 80
Bed 4 254 5340 3759 183 201
DIning Room 102 1753 795 60 43
Great Room 436 6209 5013 213 269
Kitchen 217 1012 2982 35 160
Laundry 74 211 706 7 38
M Bath 126 1922 589 66 32
M Hall 54 0 0 0 0
Master Bedroom 230 4945 2519 170 135
Mud Room 62 1393 349 48 19
Pantry 38 1298 453 44 24
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2022-Jan-12 11:21:49
Right-Suite® Universal 2021 21.0.11 RSU27054 Page 2
...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
Hall 63 0 0 0 0
Sitting Room 138 1271 903 44 48
Storage 30 607 141 21 8
WC/Tub 39 667 393 23 21
WIC 60 680 266 23 14
WIC 3 36 66 50 2 3
WIC 4 48 853 307 29 16
Wtr Clst 27 624 218 21 12
House d 2525 37434 23939 1283 1283
Other equip loads 2000 1062
Equip. @ 0.95 RSM 23851
Latent cooling 10418
TOTALS 2525 39434 34269 1283 1283
2022-Jan-12 11:21:49
Right-Suite® Universal 2021 21.0.11 RSU27054 Page 1
...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Building Analysis Dec 30, 2020Date:House Vicki Lynne NisaBy:
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
Project Information
Herd Residence, Air Conditioning Unlimited, LLCFor:
5194 Tree Top Trail, Port St Lucie, FL 34951
Design Conditions
Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US
1529Design TD (°F)ft26Elevation:
5030Relative humidity (%)°N28Latitude:
Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating
Infiltration:9041Dry bulb (°F)
Blower doorMethod)L(15-Daily range (°F)
3 (partial) / 1Shielding / stories77-Wet bulb (°F)
50 Pa / 0 cfmPressure / AVF7.515.0Wind speed (mph)
Heating
Walls
Glazing
Ceilings
Floors
Infiltration
Ducts
Ventilation
% of loadBtuhBtuh/ft²Component
21.885803.1Walls
8.633728.6Glazing
000Doors
10.240061.6Ceilings
23.392073.63.6Floors
18.472392.6Infiltration
12.85030Ducts
00Piping
00Humidification
5.12000Ventilation0Adjustments
100.039434Total
Cooling
Walls
Glazing
Ceilings Infiltration
Ducts
Internal Gains
Ventilation
% of loadBtuhBtuh/ft²Component
20.852001.9Walls
15.639089.9Glazing
000Doors
12.330861.2Ceilings
000Floors
8.621560.8Infiltration
13.43339Ducts
4.21062Ventilation
25.06250Internal gains
00Blower
0Adjustments
100.025001Total
Latent Cooling Load = 10418 Btuh
Overall U-value = 0.214 Btuh/ft²-°F
Data entries checked.
2022-Jan-12 11:21:49
Right-Suite® Universal 2021 21.0.11 RSU27054 Page 1
...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Component Constructions Dec 30, 2020Date:House Vicki Lynne NisaBy:
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
Project Information
Herd Residence, Air Conditioning Unlimited, LLCFor:
5194 Tree Top Trail, Port St Lucie, FL 34951
Design Conditions
Location: CoolingHeatingIndoor:
7570Indoor temperature (°F)St Lucie Co Intl, FL, US
1529Design TD (°F)ft26Elevation:
5030Relative humidity (%)°N28Latitude:
Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating
Infiltration:9041Dry bulb (°F)
Blower doorMethod)L(15-Daily range (°F)
3 (partial) / 1Shielding / stories77-Wet bulb (°F)
50 Pa / 0 cfmPressure / AVF7.515.0Wind speed (mph)
Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr
BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft²
Walls
Blk Wall, Stuc Ext, R-4.1 Ext Bd Ins, 8" Thk, 1/2" Gyp Bd Int Fnsh 10773.155.10.109342n 6892.02
13832.0221623.155.10.109686e
11542.0218043.155.10.109573s
15742.0224613.155.10.109781w
47992.0275033.155.10.1092381all
Partitions
Frm Wall, 1/2" Gyp Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2"x4" Wd
Frm, 16" OC Stud
4011.0910772.9411.00.101367
Windows
Impact, Clear, Low-e: Impact, Clear, Low-e; NFRC rated (SHGC=0.21);
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 1.4 ft overhang (1.2 ft window ht, 1.5 ft sep.); 8 ft head ht
236.47267.2500.2504n
Impact, Clear, Low-e: Impact, Clear, Low-e; NFRC rated (SHGC=0.21);
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 10 ft overhang (1.2 ft window ht, 1.5 ft sep.); 8 ft head ht
396.47447.2500.2506n
Impact, Clear, Low-e: Impact, Clear, Low-e; NFRC rated (SHGC=0.19);
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 10 ft overhang (6 ft window ht, 1.5 ft sep.); 8 ft head ht
2026.742528.4100.29030n
Impact, Clear, Low-e: Impact, Clear, Low-e; NFRC rated (SHGC=0.19);
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 10 ft overhang (9 ft window ht, 1.5 ft sep.); 8 ft head ht
7587.029718.9900.310108n
Impact, Clear, Low-e: Impact, Clear, Low-e; NFRC rated (SHGC=0.19);
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 1.4 ft overhang (6.7 ft window ht, 1.5 ft sep.); 8 ft head ht
1417.021818.9900.31020n
2022-Jan-12 11:21:49
Right-Suite® Universal 2021 21.0.11 RSU27054 Page 2
...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
Impact, Clear, Low-e: Impact, Clear, Low-e; NFRC rated (SHGC=0.19);
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 1.4 ft overhang (6 ft window ht, 1.5 ft sep.); 8 ft head ht
30520.31268.4100.29015e
4728.744548.4100.29054s
61020.32528.4100.29030w
36620.31518.4100.29018w
175415.09848.4100.290117all
Impact, Clear, Low-e: Impact, Clear, Low-e; NFRC rated (SHGC=0.19);
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 9 ft overhang (6 ft window ht, 1.5 ft sep.); 8 ft head ht
1588.801518.4100.29018e
Impact, Clear, Low-e: Impact, Clear, Low-e; NFRC rated (SHGC=0.21);
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 10 ft overhang (2 ft window ht, 1.5 ft sep.); 8 ft head ht
1028.47877.2500.25012s
Impact, Clear, Low-e: Impact, Clear, Low-e; NFRC rated (SHGC=0.19);
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 5.3 ft overhang (6 ft window ht, 1.5 ft sep.); 8 ft head ht
2628.742528.4100.29030s
Impact, Clear, Low-e: Impact, Clear, Low-e; NFRC rated (SHGC=0.19);
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 10 ft overhang (6.7 ft window ht, 1.5 ft sep.); 8 ft head ht
2786.913618.9900.31040s
Impact, Clear, Low-e: Impact, Clear, Low-e; NFRC rated (SHGC=0.24);
50% blinds 45°, medium; 50% outdoor insect screen; foreground = green
grass (0.23); 1.4 ft overhang (1 ft window ht, 1.5 ft sep.); 8 ft head ht
19123.8637.8300.2708w
Doors
(none)
Ceilings
Attic, Shngl Roof , R-20 Roof Deck Ins, 1/2" Gyp Bd 0.4052525 30861.2240061.5921.0
Floors
DftFlor: On Grade Depth, Carpet 00327028.700.989114
DftFlor: On Grade Depth, Tile Flr Fnsh 00593728.700.989207
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2022-Jan-12 11:21:49
Right-Suite® Universal 2021 21.0.11 RSU27054 Page 1
...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Project Summary Dec 30, 2020Date:House Vicki Lynne NisaBy:
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
Project Information
Herd Residence, Air Conditioning Unlimited, LLCFor:5194 Tree Top Trail, Port St Lucie, FL 34951
Notes:
Design Information
St Lucie Co Intl, FL, USWeather:
Winter Design Conditions Summer Design Conditions
Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75
Design TD °F29 Design TD °F15Daily range L
Relative humidity %50Moisture difference gr/lb57
Heating Summary Sensible Cooling Equipment Load Sizing
Structure Btuh32404 Structure Btuh20600
Ducts Btuh5030 Ducts Btuh3339Central vent (63 cfm) 2000 Btuh Central vent (63 cfm) Btuh1062
Outside air Outside airHumidification Btuh0 Blower Btuh0
Piping Btuh0Equipment load Btuh39434 Use manufacturer's data n
Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh23851
Method Latent Cooling Equipment Load SizingBlower door
Shielding / stories 3 (partial) / 150 Pa / 0 cfmPressure / AVF Structure Btuh5922
Ducts Btuh2071Central vent (63 cfm) Btuh2425
CoolingHeating Outside air25252525Area (ft²) Equipment latent load Btuh10418
2569725697Volume (ft³)Air changes/hour 0.300.53 Equipment Total Load (Sen+Lat)Btuh34269
Equiv. AVF (cfm) 127227 Req. total capacity at 0.70 SHR ton2.8
Heating Equipment Summary Cooling Equipment Summary
Make Make LennoxTrade Trade LENNOX
Model Cond ML14XC1-041-230A**AHRI ref Coil CBA27UHE-048-230*++TDR
AHRI ref 10259425Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER
Heating input kW11.1 Sensible cooling Btuh26950Heating output Btuh37834 Latent cooling Btuh11550
Temperature rise °F27 Total cooling Btuh38500Actual air flow cfm1283 Actual air flow cfm1283
Air flow factor cfm/Btuh0.034 Air flow factor cfm/Btuh0.054Static pressure in H2O0.70 Static pressure in H2O0.70
Space thermostat Load sensible heat ratio 0.71
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2022-Jan-12 11:21:49Right-Suite® Universal 2021 21.0.11 RSU27054 Page 1...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Right-J® Worksheet Dec 30, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
1 Room name House Bath 2
2 Exposed wall 321.0 ft 0 ft
3 Room height 10.2 dft 9.4 heat/coolft
4 Room dimensions ft6.0x6.5
5 Room area 2524.8 ft²39.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 nn 3.153.15 2.022.02 509 342 1077 689 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 4 0 26 23 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 6 0 44 39 0 0 0 0
.GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 nn 8.418.41 6.746.74 30 0 252 202 0 0 0 0
11 GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 108 0 971 758 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 20 0 181 141 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ee 3.153.15 2.022.02 719 686 2162 1383 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 20.3420.34 15 0 126 305 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 8.808.80 18 18 151 158 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ss 3.153.15 2.022.02 709 572 1804 1154 0 0 0 0
GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 ss 7.257.25 8.478.47 12 12 87 102 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 54 54 454 472 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 30 30 252 262 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 ss 8.998.99 6.916.91 40 40 361 278 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ww 3.153.15 2.022.02 837 781 2461 1574 0 0 0 0
GG Impact, Clear, Low-e 0.270Impact, Clear, Low-e 0.270 ww 7.837.83 23.8423.84 8 0 63 191 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 30 0 252 610 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 18 0 151 366 0 0 0 0
PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 367 367 1077 401 0 0 0 0
CC Attic, Shngl Roof , 0.405Attic, Shngl Roof , 0.405 --1.591.59 1.221.22 2525 2525 4006 3086 39 39 62 48
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 851 114 3270 0 0 0 0 0
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 1674 207 5937 0 39 0 0 0
6 c) AED excursion 0 -1
Envelope loss/gain 25165 12194 62 47
12 a) Infiltration 7239 2156 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 5 1150 0 0
Appliances/other 5100 0
Subtotal (lines 6 to 13)32404 20600 62 47
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 87 35
14 Subtotal 32404 20600 149 82
15 Duct loads 16%16%5030 3339 16%16%23 13
Total room load 37434 23939 172 96
Air required (cfm)Air required (cfm)1283 1283 6 5
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2022-Jan-12 11:21:49Right-Suite® Universal 2021 21.0.11 RSU27054 Page 2...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Right-J® Worksheet Dec 30, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
1 Room name Bath 4 Bed 2
2 Exposed wall 15.0 ft 47.5 ft
3 Room height 9.4 heat/coolft 9.4 heat/coolft
4 Room dimensions ft79.5x1.0 ft217.5x1.0
5 Room area 79.5 ft²217.5 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 nn 3.153.15 2.022.02 14 14 44 28 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 nn 8.418.41 6.746.74 0 0 0 0 0 0 0 0
11 GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ee 3.153.15 2.022.02 0 0 0 0 141 141 444 284
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 8.808.80 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ss 3.153.15 2.022.02 14 14 44 28 164 146 462 295
GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 ss 7.257.25 8.478.47 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 18 18 151 157
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 ss 8.998.99 6.916.91 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ww 3.153.15 2.022.02 113 109 343 219 141 141 444 284
GG Impact, Clear, Low-e 0.270Impact, Clear, Low-e 0.270 ww 7.837.83 23.8423.84 4 0 31 95 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 0 0 0 0 0 0 0 0
CC Attic, Shngl Roof , 0.405Attic, Shngl Roof , 0.405 --1.591.59 1.221.22 80 80 126 97 218 218 345 266
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 0 0 0 0 218 48 1362 0
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 80 15 430 0 0 0 0 0
6 c) AED excursion 41 -31
Envelope loss/gain 1019 509 3209 1256
12 a) Infiltration 368 110 1165 347
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 0 0 0 0
Appliances/other 0 250
Subtotal (lines 6 to 13)1387 619 4374 1853
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 65 27
14 Subtotal 1387 619 4440 1879
15 Duct loads 16%16%215 100 16%16%689 305
Total room load 1603 719 5129 2184
Air required (cfm)Air required (cfm)55 39 176 117
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2022-Jan-12 11:21:49Right-Suite® Universal 2021 21.0.11 RSU27054 Page 3...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Right-J® Worksheet Dec 30, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
1 Room name Bed 3 Bed 4
2 Exposed wall 12.0 ft 46.5 ft
3 Room height 9.4 heat/coolft 9.4 heat/coolft
4 Room dimensions ft12.0x13.0 ft14.5x17.5
5 Room area 156.0 ft²253.8 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 nn 3.153.15 2.022.02 0 0 0 0 164 141 444 284
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 4 0 26 23
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 nn 8.418.41 6.746.74 0 0 0 0 0 0 0 0
11 GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 20 0 181 141
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ee 3.153.15 2.022.02 0 0 0 0 136 121 382 244
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 20.3420.34 0 0 0 0 15 0 126 305
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 8.808.80 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ss 3.153.15 2.022.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 ss 7.257.25 8.478.47 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 ss 8.998.99 6.916.91 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ww 3.153.15 2.022.02 113 95 299 191 136 106 335 214
GG Impact, Clear, Low-e 0.270Impact, Clear, Low-e 0.270 ww 7.837.83 23.8423.84 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 30 0 252 610
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 18 0 151 366 0 0 0 0
PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 0 0 0 0 0 0 0 0
CC Attic, Shngl Roof , 0.405Attic, Shngl Roof , 0.405 --1.591.59 1.221.22 156 156 247 191 254 254 403 310
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 156 12 344 0 0 0 0 0
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 0 0 0 0 254 47 1334 0
6 c) AED excursion 156 12
Envelope loss/gain 1042 904 3482 2145
12 a) Infiltration 294 88 1141 340
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 0 0 0 0
Appliances/other 250 750
Subtotal (lines 6 to 13)1336 1242 4623 3234
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 116 47 0 0
14 Subtotal 1452 1289 4623 3234
15 Duct loads 16%16%225 209 16%16%718 524
Total room load 1678 1498 5340 3759
Air required (cfm)Air required (cfm)58 80 183 201
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2022-Jan-12 11:21:49Right-Suite® Universal 2021 21.0.11 RSU27054 Page 4...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Right-J® Worksheet Dec 30, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
1 Room name DIning Room Great Room
2 Exposed wall 12.0 ft 35.5 ft
3 Room height 12.0 heat/coolft 12.0 heat/coolft
4 Room dimensions ft8.5x12.0 ft436.3x1.0
5 Room area 102.0 ft²436.3 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 nn 3.153.15 2.022.02 144 108 340 218 168 60 189 121
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 6 0 44 39 0 0 0 0
.GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 nn 8.418.41 6.746.74 30 0 252 202 0 0 0 0
11 GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 108 0 971 758
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 8.808.80 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ss 3.153.15 2.022.02 0 0 0 0 234 152 478 306
GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 ss 7.257.25 8.478.47 0 0 0 0 12 12 87 102
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 30 30 252 262
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 ss 8.998.99 6.916.91 0 0 0 0 40 40 361 278
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ww 3.153.15 2.022.02 0 0 0 0 24 24 76 48
GG Impact, Clear, Low-e 0.270Impact, Clear, Low-e 0.270 ww 7.837.83 23.8423.84 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 0 0 0 0 0 0 0 0
CC Attic, Shngl Roof , 0.405Attic, Shngl Roof , 0.405 --1.591.59 1.221.22 102 102 162 125 436 436 692 533
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 0 0 0 0 0 0 0 0
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 102 12 344 0 436 36 1018 0
6 c) AED excursion -11 -71
Envelope loss/gain 1142 572 4125 2337
12 a) Infiltration 376 112 1112 331
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 0 0 3 690
Appliances/other 0 900
Subtotal (lines 6 to 13)1518 684 5237 4258
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 138 56
14 Subtotal 1518 684 5375 4314
15 Duct loads 16%16%236 111 16%16%834 699
Total room load 1753 795 6209 5013
Air required (cfm)Air required (cfm)60 43 213 269
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2022-Jan-12 11:21:49Right-Suite® Universal 2021 21.0.11 RSU27054 Page 5...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Right-J® Worksheet Dec 30, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
1 Room name Kitchen Laundry
2 Exposed wall 0 ft 0 ft
3 Room height 12.0 heat/coolft 9.4 heat/coolft
4 Room dimensions ft217.3x1.0 ft74.0x1.0
5 Room area 217.3 ft²74.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 nn 8.418.41 6.746.74 0 0 0 0 0 0 0 0
11 GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 8.808.80 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ss 3.153.15 2.022.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 ss 7.257.25 8.478.47 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 ss 8.998.99 6.916.91 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ww 3.153.15 2.022.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.270Impact, Clear, Low-e 0.270 ww 7.837.83 23.8423.84 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 0 0 0 0 0 0 0 0
CC Attic, Shngl Roof , 0.405Attic, Shngl Roof , 0.405 --1.591.59 1.221.22 217 217 345 266 74 74 117 90
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 0 0 0 0 74 0 0 0
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 217 0 0 0 0 0 0 0
6 c) AED excursion -40 -10
Envelope loss/gain 345 226 117 81
12 a) Infiltration 0 0 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 2 460 0 0
Appliances/other 1700 500
Subtotal (lines 6 to 13)345 2386 117 581
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 531 181 65 27
14 Subtotal 876 2566 183 607
15 Duct loads 16%16%136 416 16%16%28 98
Total room load 1012 2982 211 706
Air required (cfm)Air required (cfm)35 160 7 38
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2022-Jan-12 11:21:49Right-Suite® Universal 2021 21.0.11 RSU27054 Page 6...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Right-J® Worksheet Dec 30, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
1 Room name M Bath M Hall
2 Exposed wall 22.0 ft 15.0 ft
3 Room height 9.4 heat/coolft 9.4 heat/coolft
4 Room dimensions ft125.8x1.0 ft9.0x6.0
5 Room area 125.8 ft²54.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 nn 8.418.41 6.746.74 0 0 0 0 0 0 0 0
11 GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ee 3.153.15 2.022.02 80 80 252 161 47 47 148 95
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 8.808.80 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ss 3.153.15 2.022.02 0 0 0 0 56 56 178 114
GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 ss 7.257.25 8.478.47 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 ss 8.998.99 6.916.91 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ww 3.153.15 2.022.02 0 0 0 0 38 38 118 76
GG Impact, Clear, Low-e 0.270Impact, Clear, Low-e 0.270 ww 7.837.83 23.8423.84 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 127 127 373 139 0 0 0 0
CC Attic, Shngl Roof , 0.405Attic, Shngl Roof , 0.405 --1.591.59 1.221.22 126 126 200 154 54 54 86 66
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 0 0 0 0 0 0 0 0
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 126 22 631 0 54 15 430 0
6 c) AED excursion -9 -8
Envelope loss/gain 1455 445 960 343
12 a) Infiltration 208 62 368 110
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)1664 507 1328 452
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 -1328 -452
14 Subtotal 1664 507 0 0
15 Duct loads 16%16%258 82 16%16%0 0
Total room load 1922 589 0 0
Air required (cfm)Air required (cfm)66 32 0 0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2022-Jan-12 11:21:49Right-Suite® Universal 2021 21.0.11 RSU27054 Page 7...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Right-J® Worksheet Dec 30, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
1 Room name Master Bedroom Mud Room
2 Exposed wall 45.0 ft 18.5 ft
3 Room height 9.4 heat/coolft 9.4 heat/coolft
4 Room dimensions ft13.5x17.0 ft61.8x1.0
5 Room area 229.5 ft²61.8 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 nn 3.153.15 2.022.02 9 9 30 19 9 9 30 19
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 nn 8.418.41 6.746.74 0 0 0 0 0 0 0 0
11 GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ee 3.153.15 2.022.02 127 127 400 256 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 8.808.80 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ss 3.153.15 2.022.02 160 124 390 250 0 0 0 0
GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 ss 7.257.25 8.478.47 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 36 36 303 315 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 ss 8.998.99 6.916.91 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ww 3.153.15 2.022.02 127 127 400 256 14 14 44 28
GG Impact, Clear, Low-e 0.270Impact, Clear, Low-e 0.270 ww 7.837.83 23.8423.84 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 0 0 0 0 150 150 442 165
CC Attic, Shngl Roof , 0.405Attic, Shngl Roof , 0.405 --1.591.59 1.221.22 230 230 364 280 62 62 98 75
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 230 45 1291 0 0 0 0 0
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 0 0 0 0 62 19 531 0
6 c) AED excursion -36 -5
Envelope loss/gain 3177 1339 1144 282
12 a) Infiltration 1104 329 61 18
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 0 0 0 0
Appliances/other 500 0
Subtotal (lines 6 to 13)4281 2167 1206 301
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 4281 2167 1206 301
15 Duct loads 16%16%664 351 16%16%187 49
Total room load 4945 2519 1393 349
Air required (cfm)Air required (cfm)170 135 48 19
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2022-Jan-12 11:21:49Right-Suite® Universal 2021 21.0.11 RSU27054 Page 8...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Right-J® Worksheet Dec 30, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
1 Room name Pantry Hall
2 Exposed wall 7.5 ft 4.5 ft
3 Room height 9.4 heat/coolft 9.4 heat/coolft
4 Room dimensions ft5.0x7.5 ft14.0x4.5
5 Room area 37.5 ft²63.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 nn 8.418.41 6.746.74 0 0 0 0 0 0 0 0
11 GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ee 3.153.15 2.022.02 0 0 0 0 42 42 133 85
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 8.808.80 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ss 3.153.15 2.022.02 70 70 222 142 0 0 0 0
GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 ss 7.257.25 8.478.47 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 ss 8.998.99 6.916.91 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ww 3.153.15 2.022.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.270Impact, Clear, Low-e 0.270 ww 7.837.83 23.8423.84 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 0 0 0 0 0 0 0 0
CC Attic, Shngl Roof , 0.405Attic, Shngl Roof , 0.405 --1.591.59 1.221.22 38 38 59 46 63 63 100 77
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 0 0 0 0 0 0 0 0
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 38 8 215 0 63 5 129 0
6 c) AED excursion -4 -3
Envelope loss/gain 497 184 362 159
12 a) Infiltration 184 55 110 33
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)681 239 473 192
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 443 151 -473 -192
14 Subtotal 1123 389 0 0
15 Duct loads 16%16%174 63 16%16%0 0
Total room load 1298 453 0 0
Air required (cfm)Air required (cfm)44 24 0 0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2022-Jan-12 11:21:49Right-Suite® Universal 2021 21.0.11 RSU27054 Page 9...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Right-J® Worksheet Dec 30, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
1 Room name Sitting Room Storage
2 Exposed wall 9.5 ft 8.5 ft
3 Room height 9.4 heat/coolft 9.4 heat/coolft
4 Room dimensions ft12.0x11.5 ft8.5x3.5
5 Room area 138.0 ft²29.8 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 nn 8.418.41 6.746.74 0 0 0 0 0 0 0 0
11 GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ee 3.153.15 2.022.02 89 71 225 144 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 8.808.80 18 18 151 158 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ss 3.153.15 2.022.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 ss 7.257.25 8.478.47 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 ss 8.998.99 6.916.91 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ww 3.153.15 2.022.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.270Impact, Clear, Low-e 0.270 ww 7.837.83 23.8423.84 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 0 0 0 0 80 80 235 87
CC Attic, Shngl Roof , 0.405Attic, Shngl Roof , 0.405 --1.591.59 1.221.22 138 138 219 169 30 30 47 36
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 138 10 272 0 0 0 0 0
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 0 0 0 0 30 9 244 0
6 c) AED excursion -13 -2
Envelope loss/gain 867 458 526 122
12 a) Infiltration 233 69 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 0 0 0 0
Appliances/other 250 0
Subtotal (lines 6 to 13)1100 777 526 122
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 1100 777 526 122
15 Duct loads 16%16%171 126 16%16%82 20
Total room load 1271 903 607 141
Air required (cfm)Air required (cfm)44 48 21 8
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2022-Jan-12 11:21:49Right-Suite® Universal 2021 21.0.11 RSU27054 Page 10...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Right-J® Worksheet Dec 30, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
1 Room name WC/Tub WIC
2 Exposed wall 6.0 ft 2.0 ft
3 Room height 9.4 heat/coolft 9.4 heat/coolft
4 Room dimensions ft6.0x6.5 ft60.3x1.0
5 Room area 39.0 ft²60.3 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 nn 8.418.41 6.746.74 0 0 0 0 0 0 0 0
11 GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 8.808.80 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ss 3.153.15 2.022.02 0 0 0 0 9 9 30 19
GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 ss 7.257.25 8.478.47 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 ss 8.998.99 6.916.91 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ww 3.153.15 2.022.02 56 52 165 106 0 0 0 0
GG Impact, Clear, Low-e 0.270Impact, Clear, Low-e 0.270 ww 7.837.83 23.8423.84 4 0 31 95 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 0 0 0 0 9 9 28 10
CC Attic, Shngl Roof , 0.405Attic, Shngl Roof , 0.405 --1.591.59 1.221.22 39 39 62 48 60 60 96 74
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 0 0 0 0 0 0 0 0
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 39 6 172 0 60 2 57 0
6 c) AED excursion 45 -2
Envelope loss/gain 430 294 210 101
12 a) Infiltration 147 44 25 7
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)578 338 235 108
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 354 121
14 Subtotal 578 338 589 229
15 Duct loads 16%16%90 55 16%16%91 37
Total room load 667 393 680 266
Air required (cfm)Air required (cfm)23 21 23 14
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2022-Jan-12 11:21:49Right-Suite® Universal 2021 21.0.11 RSU27054 Page 11...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Right-J® Worksheet Dec 30, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
1 Room name WIC 3 WIC 4
2 Exposed wall 0 ft 8.0 ft
3 Room height 9.4 heat/coolft 9.4 heat/coolft
4 Room dimensions ft8.0x4.5 ft8.0x6.0
5 Room area 36.0 ft²48.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 nn 7.257.25 6.476.47 0 0 0 0 0 0 0 0
.GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 nn 8.418.41 6.746.74 0 0 0 0 0 0 0 0
11 GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 nn 8.998.99 7.027.02 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ee 8.418.41 8.808.80 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ss 3.153.15 2.022.02 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.250Impact, Clear, Low-e 0.250 ss 7.257.25 8.478.47 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ss 8.418.41 8.748.74 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.310Impact, Clear, Low-e 0.310 ss 8.998.99 6.916.91 0 0 0 0 0 0 0 0
WW Blk Wall, Stuc Ext, 0.109Blk Wall, Stuc Ext, 0.109 ww 3.153.15 2.022.02 0 0 0 0 75 75 237 152
GG Impact, Clear, Low-e 0.270Impact, Clear, Low-e 0.270 ww 7.837.83 23.8423.84 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
GG Impact, Clear, Low-e 0.290Impact, Clear, Low-e 0.290 ww 8.418.41 20.3420.34 0 0 0 0 0 0 0 0
PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.091.09 0 0 0 0 0 0 0 0
CC Attic, Shngl Roof , 0.405Attic, Shngl Roof , 0.405 --1.591.59 1.221.22 36 36 57 44 48 48 76 59
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 36 0 0 0 0 0 0 0
FF DftFlorDftFlor 0.9890.989 --28.6828.68 0.000.00 0 0 0 0 48 8 229 0
6 c) AED excursion -1 -4
Envelope loss/gain 57 43 543 206
12 a) Infiltration 0 0 196 58
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)57 43 739 264
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 57 43 739 264
15 Duct loads 16%16%9 7 16%16%115 43
Total room load 66 50 853 307
Air required (cfm)Air required (cfm)2 3 29 16
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2022-Jan-12 11:21:49Right-Suite® Universal 2021 21.0.11 RSU27054 Page 12...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Right-J® Worksheet Dec 30, 2020Date:House Vicki Lynne NisaBy:Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
1 Room name Wtr Clst
2 Exposed wall 6.0 ft
3 Room height 9.4 heat/coolft
4 Room dimensions ft6.0x4.5
5 Room area 27.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area Load
number (Btuh/ft²-°F)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 W Blk Wall, Stuc Ext, 0.109 n 3.15 2.02 0 0 0 0
.G Impact, Clear, Low-e 0.250 n 7.25 6.47 0 0 0 0
.G Impact, Clear, Low-e 0.250 n 7.25 6.47 0 0 0 0
.G Impact, Clear, Low-e 0.290 n 8.41 6.74 0 0 0 0
11 G Impact, Clear, Low-e 0.310 n 8.99 7.02 0 0 0 0
G Impact, Clear, Low-e 0.310 n 8.99 7.02 0 0 0 0
W Blk Wall, Stuc Ext, 0.109 e 3.15 2.02 56 56 178 114
G Impact, Clear, Low-e 0.290 e 8.41 20.34 0 0 0 0
G Impact, Clear, Low-e 0.290 e 8.41 8.80 0 0 0 0
W Blk Wall, Stuc Ext, 0.109 s 3.15 2.02 0 0 0 0
G Impact, Clear, Low-e 0.250 s 7.25 8.47 0 0 0 0
G Impact, Clear, Low-e 0.290 s 8.41 8.74 0 0 0 0
G Impact, Clear, Low-e 0.290 s 8.41 8.74 0 0 0 0
G Impact, Clear, Low-e 0.310 s 8.99 6.91 0 0 0 0
W Blk Wall, Stuc Ext, 0.109 w 3.15 2.02 0 0 0 0
G Impact, Clear, Low-e 0.270 w 7.83 23.84 0 0 0 0
G Impact, Clear, Low-e 0.290 w 8.41 20.34 0 0 0 0
G Impact, Clear, Low-e 0.290 w 8.41 20.34 0 0 0 0
P Frm Wall, 1/2" Gyp B 0.101 -2.94 1.09 0 0 0 0
C Attic, Shngl Roof , 0.405 -1.59 1.22 27 27 43 33
F DftFlor 0.989 -28.68 0.00 0 0 0 0
F DftFlor 0.989 -28.68 0.00 27 6 172 0
6 c) AED excursion -3
Envelope loss/gain 393 144
12 a) Infiltration 147 44
b) Room ventilation 0 0
13 Internal gains: Occupants @ 230 0 0
Appliances/other 0
Subtotal (lines 6 to 13)540 187
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 540 187
15 Duct loads 16%16%84 30
Total room load 624 218
Air required (cfm)21 12
2022-Jan-12 11:21:51
Right-Suite® Universal 2021 21.0.11 RSU27054 Page 1
...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Duct System Summary Dec 30, 2020Date:House Vicki Lynne NisaBy:
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
Project Information
Herd Residence, Air Conditioning Unlimited, LLCFor:
5194 Tree Top Trail, Port St Lucie, FL 34951
CoolingHeating
External static pressure in H2O0.70in H2O0.70
Pressure losses in H2O0in H2O0
Available static pressure in H2O0.70in H2O0.70
Supply / return available pressure 0.535 / 0.165 in H2O in H2O0.535 / 0.165
Lowest friction rate in/100ft0.092in/100ft0.092
Actual air flow cfm1283cfm1283
Total effective length (TEL) ft757
Supply Branch Detail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv
Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk
st6500.064.4VlFx0x04.00.09567172hBath 2
st5500.062.9VlFx0x05.00.09546661603hBath 4
st6500.075.8VlFx0x09.00.0931402115129hBed 2
st6500.062.9VlFx0x06.00.09596691498cBed 3
st5500.078.7VlFx0x010.00.0922422203759cBed 4
st1200.026.4VlFx0x05.00.23651721753hDIning Room
st3300.037.2VlFx0x08.00.1591611282507cGreat Room
st3300.036.7VlFx0x08.00.1591611282507cGreat Room-A
st1200.017.5VlFx0x06.00.24696211491cKitchen
st1200.016.2VlFx0x06.00.24796211491cKitchen-A
st4400.048.2VlFx0x04.00.119459706cLaundry
st2205.016.2VlFx0x06.00.24238791922hM Bath
00VlFx0x000811021259hMaster Bedroom
00VlFx0x000811021259hMaster Bedroom-A
st1200.024.6VlFx0x05.00.23822571393hMud Room
st1200.021.5VlFx0x04.00.24129531298hPantry
st5500.065.4VlFx0x05.00.0955852903cSitting Room
st1200.024.1VlFx0x04.00.239925607hStorage
st6500.065.7VlFx0x04.00.0952527667hWC/Tub
st2205.014.3VlFx0x04.00.2441728680hWIC
st4400.048.8VlFx0x04.00.1193350cWIC 3
st5500.067.8VlFx0x04.00.0942035853hWIC 4
st2205.020.5VlFx0x04.00.2371426624hWtr Clst
2022-Jan-12 11:21:51
Right-Suite® Universal 2021 21.0.11 RSU27054 Page 2
...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
Supply Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk
st5 Peak AVF 373 366 0.092 475 12.0 0x0 VinlFlx st4
st6 Peak AVF 315 268 0.093 401 12.0 0x0 VinlFlx st4
st4 Peak AVF 699 683 0.092 501 16.0 0x0 VinlFlx st3
st3 Peak AVF 954 1005 0.092 569 18.0 0x0 VinlFlx st1
st1 Peak AVF 1204 1309 0.092 741 18.0 0x0 VinlFlx
st2 Peak AVF 133 69 0.237 497 7.0 0x0 VinlFlx
Return Branch Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk
rb2 0x 7190 801 178.7 0.092 574 16.0 x0 0 VlFx rt1
rb1 0x 2310 179 0 0 0 0 x0 0 VlFx
rb6 0x 2550 262 0 0 0 0 x0 0 VlFx
rb5 0x 520 58 0 0 0 0 x0 0 VlFx
rb4 0x 720 100 0 0 0 0 x0 0 VlFx
rb3 0x 2110 140 0 0 0 0 x0 0 VlFx
Return Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk
rt1 Peak AVF 719 801 0.092 574 16.0 0x0 VinlFlx
2022-Jan-12 11:21:51
Right-Suite® Universal 2021 21.0.11 RSU27054 Page 1
...Wrightsoft HVAC\5194 Tree Top Trail Revised.rup Calc = MJ8 Front Door faces: S
1403Job:Manual S Compliance Report Dec 30, 2020Date:House Vicki Lynne NisaBy:
Air Calcs, LLC
7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com
Project Information
Herd Residence, Air Conditioning Unlimited, LLCFor:
5194 Tree Top Trail, Port St Lucie, FL 34951
Cooling Equipment
Design Conditions
°F75.9Entering coil DB:Btuh25001Sensible gain:°F90.4Outdoor design DB:
°F63.8Entering coil WB:Btuh10418Latent gain:°F77.4Outdoor design WB:
Btuh35419Total gain:°F75.0Indoor design DB:
cfm1283Estimated airflow:%50Indoor RH:
Manufacturer's Performance Data at Actual Design Conditions
Split ACEquipment type:
ML14XC1-041-230A**+CBA27UHE-048-230*++TDRModel:LennoxManufacturer:
cfm1283Actual airflow:
% of load108Btuh26950Sensible capacity:
% of load111Btuh11550Latent capacity:
%70SHR:% of load109Btuh38500Total capacity:
Heating Equipment
Design Conditions
°F68.4Entering coil DB:Btuh39434Heat loss:°F41.0Outdoor design DB:
°F70.0Indoor design DB:
Manufacturer's Performance Data at Actual Design Conditions
Elec stripEquipment type:
Model:Manufacturer:
cfm1283Actual airflow:
°F50Temp. rise:% of load96kW11.1Output capacity:
Meets all requirements of ACCA Manual S.