Loading...
HomeMy WebLinkAboutfire department #3SAINT LUCIE COUNTY FIRE DISTRICT PLAN REVIEW FORM 5160 N.W. Milner Drive Port Saint Lucie, FL 34983 Telephone: 772-621-3322 Fax: 772-621-3604 Web Address: www.slcfd.com Building Dept. SLC FMO Permit # B-22-12 Project Name Contenders Boats BLDG Permit # 2107-0115 Address 5701 Environmental Drive City Ft Pierce Contractor Paul Jacquin & Sons Address 7348 Commercial Circle City I Ft Pierce State FL Zip 34951 Telephone (772)465-2475 Architect/Engineer Donadio Architects Telephone (772)794-2929 Occupancy Type Industrial Construction Type IIB Square Feet 103,480 Occupant Load 1035 per plans7 Number of Stories Access Box Required Access Key Switch AFSPermit Required FA Permit Required FFP Permit General Notes 1. An electronic copy of the construction documents submitted on a CD is required. The file format shall be .pdf only. 2. All revisions, including the electronic copy must be received prior to permitting. 3. The Fire Marshal requires 24 hour notice on all inspections. 4. A Radio coverage Pre -Survey Signal Strength inspection is required before any final inspection is scheduled. 5. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 6. Failed inspections require payment of fee prior to rescheduling of further inspections. 7. Penetrations through rated assemblies shall be of the proper LIL design. Design criteria shall be submitted with the construction plans. 8. Fire alarm panels shall be located indoors within air conditioned space. 9. Plans and construction are subject to corrections in the field to maintain code compliance. 10. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity. 11. The Installation or Alterafion of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit. THE CURRENTLY ADOPTED VERSION OF THE FLORIDA FIRE PREVENTION CODE IS ENFORCED. BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. See General Notes Above and Required Revisions Below 1. A separate review and permit is required for the installation or alteration of the fire alarm and fire sprinkler systems 2. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity. Provide a remote test and inspect appliance equipped with an audible/visual indicator for each HVAC duct smoke detector. HVAC duct smoke detector(s) shall be tied into the fire alarm system. 3. Spray booths shall be protected with an U.L. approved Fire Suppression System Page 1❑ of 117, Reviewed by Tony Jerger Date 01 12-2022