Loading...
HomeMy WebLinkAboutENGINEERING SCOPE OF WORK PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W.Biltmore St. Suite#114 Port Saint Lucie,FL 34984 Phone(772) 785 - 9888 Fax(772) 785-9933 December 3,2021 Re: RE-ROOF 1066 NETTLES BLVD JENSEN BEACH, FL. SCOPE OF WORK: -Remove existing roofing on sun-deck J �� -Renail existing deck w/#10 wood screws at 6" o.c. max `v -Install new roofing per plan DESIGN CRITERIA: GOP FBC 2020 ASCE7-16 PROJECT DATA: Building Height(R)= 12 A (ft)= 5 Mean Roof Height(R)= 12 Roof Pitch= 0.3 /12 Shape= FLAT/MONO Adjustment Factor= 1.00 Improtance Factor= 1.00 Wind Velocity= 170 mph (3 see gust) Exposure= D Enclosure Class= PARTIALY ENCLOSED Inter.Press. Coef = - 0.18 APPLIED UPLIFT_ DESIGN PRESSURES ON ROOF (ASCE 6-3) : Zone 1 (Field)= 73.10 ( - PSF) Zone 2(Perimeter/Ridge) = 96.40 ( - PSF) Zone 3 (Corners)= 131.40 ( - PSF) DEC 0 3 2021 = = PAu WELCH MC. MECH= LECT-CIVIL EPlG. - 9984 BILTMORE ST.#114 - : PgRT SAINT LUCII~,FL 349 PAUL W&CH P.E. FLA IIEG NO.26945 ROOF DATA: Manufacturer: polyglass usa Type: mod bit NOA#: 17-0825.01 System Type: E(10)INSULATED &B(3)NON-INSULATED Design Pressure: -90 (-PSF) Membrane Type: ELASTOFLEX S6 G TORCH APPLIED Deck: 19/32 "Plywood Base Sheet: XTRAFLEX SBS GLASS BASE Fasteners: INSULATION FASTENED WITH 3" ROUND OMG GALVALUME STEEL PLATES AND OMG HEAVY DUTY FASTNERS (spacing per base sheet attachment requirements) , BASE SHEET ATTACIEMNT REOUIREMENTS: ZONE 1 : Base sheet attached to deck with Fasteners as specified above (Field) at 6 "O.C. in ( 4 )rows. One row is in the side lap. The other rows are equally spaced approximately # " O.C. in the field of the sheet. (METHOD PER NOA) Design Pressure(-PSF): -90 ZONE 2 : Base sheet attached to deck with Fasteners as specified.above (Perimeter/Ridge) at 5 "O.C. in ( 4 )rows. One row is in the side lap. The other rows are equally spaced approximately # "O.C. in the field of the sheet. (ENHANCED FASTENERS) Design Pressure(-PSF): -97.03 ZONE 3 : Base sheet attached to deck with Fasteners as specified;above (Corners) at 3 "O.C. in ( 4 )rows. One row is in the side lap.; The other rows are equally spaced approximately # " O.C. in the field of the sheet. (ENHANCED FASTENERS) Design Pressure(-PSF): -161.71 NOTE:AN 18" STRIP OF ISO BOARD TO BE INSTALLED ADJACENT TO RESIDENCE TO PROVIDE PITCH AWAY FROM THE RESIDENCE AND INSTALLED WITH OMG 3" GALVALUME STEEL PLATES AND OMG HEAVY DUTY FASTNERS AT A 2:1 FT SQ RATIO AND THE ELASTOFLEX SBS GLASS BASE SHALL BE TORCH APPLIED UNDER THE INSULATION DEC 0 3 2021 IaAu_ WELCH INC. - = MECH• LECT-CIVIL ENO. - 1084 BILTMORE ST.#114 / PORT SAINT LUCIE,FL 34984 PAUL WELCH R.E. FL4 REG NO.29945 r- • ATTACHMENT CALCULATIONS FOR ENHANCED FASTENERS FOR ZONE 2: PER RAS 117 FS= ,.ff X 114 (P)X(RS) FS=fastener spacing(in) fy =DPX(sq.ft. lfastener) _ -33.16 (lb /fastener) P =(design pressure req'd for zone 2) = 96.4 (Ib /ft2) RS=row spacing = 9.84375 (in) r -33.16 X 144 FS= ------------------- _ -5.0326 (in /fastener) fasteners @ 5 "O.C. 96.4 X 9.84375 ATTACHMENT CALCULATIONS FOR ENHANCED FASTENERS FOR ZONE 3: PER RAS 117 FS= , X 114 (P)X(RS) FS=fastener spacing(in) fy =DPX(sq.ft. /fastener) _ -33.16 (Ib/fastener) P =(design pressure req'd for zone 3) = 131.4 (lb /ft2) RS=row spacing= 9.84375 (in) -33.16 X 144 FS= ------------------- _ -3.69211 (in /fastener) —>fasteners @ 3 "O.C. 131.4 X 9.84375 DECK INSTALLATION: EXISTING DECK TO BE SCREWED WITH#10 WOOD SCREWS AT 6" O.C. All work to be in compliance with product approval, manufacturer's specifications, and the Florida Building Code 2020. Submitted by: PAUL WELCH INC. Paul Welch,P.E. DEC 0 3 2021 Reg.No 29945 PAUX WFMCM INC. PW:NS MECH-ELECT-CIVIL ENO. 1984 BILTMORE ST.#114 PORT SAINT LUC:IE,FL PAUL WELCH 3498�F P E / PLA REG NO.29946