Loading...
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSProperty Information Owner:COMFORT, BRIAN / ELIZABETH Address:8306 CITRUS PARK BLVD. FT. PIERCE, FL. 34951 Building Information Wind Zone:170 MPH. Exposure Category:C Minimum Building Dimension:55 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 24.75 61.25 7 37.7 -40.9 2 Int 72 61.25 7 35.0 -38.2 3 Int 24.75 61.25 7 37.7 -40.9 4 End 35.5 61.25 7 36.8 -48.6 5 End 35.25 48.75 7 37.4 -49.7 6 End 35.25 48.75 7 37.4 -49.7 7 End 35.25 48.75 7 37.4 -49.7 8 Int 17.5 48.75 7 37.8 -41.0 9 Int 35.25 48.75 7 37.4 -40.6 10 Int 17.5 48.75 7 37.8 -41.0 11 End 71.5 79.5 7 34.4 -43.9 12 Int 72 48.75 7 35.6 -38.8 13 End 72 48.75 7 35.6 -46.2 14 End 35.25 48.75 7 37.4 -49.7 15 End 24.75 24 7 37.8 -50.6 16 Int 35.25 48.75 7 37.4 -40.6 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1