Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEET � r 4 ST. LUCIE U10PIKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET FILE COPY Florida Building Code 7th Edition (2020) REV9IEWED FOR Based.on Section 1525 of the Florida Building Code-BuGGDEI COMPLIANCE NCE INSTRUCTION PAGE -ST. LUCIE COUNTY BOCC COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required -- - — - Roof System the Permit Application See List Below Form Low Slope Application A, B,C 1234-5 . Prescriptive BUR-RAS 150 A,B,C 2,4,5,6,7 Asphaltic Shingles A, B, D tq�r�ga7 l Concrete or Clay Tile A,B,D,E 123;4A6;7. Metal Roofs A, B, D 1,294, , T I Wood Shingles and A, B, D i ;467 Shakes Other As Applicable 1A.%4A4,7 l ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16,or if applicable,RAS 127 or RAS+128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations(Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18,2021 ST. LUCIE WORKS Section A (General Information) Master Permit No. Process No. i Contractors Name: C, Li LL License# Job Address 44QS VVVG►2C=QB2— 'R�P t'i 1c[?� ROOF CATEGORY Wow Slope 0 Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles Psphaltic Shingles El Metal Panel/Shingles OWood Shingles/Shakes 0 Prescriptive BUR-RAS 150 ROOF ROOF TYPE i 0 New roof 0 Repair 0 Maintenance 'Reroofing ❑IRecovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area(SF) ESQ Total(SF) 1 l00 i Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers land overflow drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. I AIL � r i (G t 6 i i ST. LUCIE WORKS Section C(Low Slope Roof) Surfacing: Lv"4rr. L waJ CLS Fastener Spacing for Anchor/Base S! heet Attachment:Fill in specific roof assembly components and identify manufacturer Zone 1':—." oc @ Lap,#Rowsl 'O ' (If a component is not used,identify as"NA") Zone 1:____" oc @ Lap,#Rows System Manufacturer: ��y4S (Lh,� Zone 2:—" oc @ Lap;#Rows I ' Zone 3:—" oc @ Lap;#Rows 0 '00 ' Product Approval No.: i Number of Fasteners Per Insulatioh Board: Design Wind Pressures,From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3: Zone 1'._Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Max. Design.Pressure,from the specific product approval Woodblocking, Gutter, Edge I Termination, Stripping, system: Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing,Coping, Etc.. Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base Type: 1 r e4t,4pS Flashing,Component Material,Material'Thickness, Fastener Type',Fastener Spacing or Submit Manufacturers Details that Gauge Thickness: f''f [is��F. Comply with RAS 111 and Chapter 16.. Slope: `f l Anchor/Base Sheet&No.df Ply(s): t+k5cci Anchor/Base Sheet Fastener/Bonding Material: FT. insulation Base Layer: Base insultation Size and Thickness: Parapet r Base Insulation Fastener/Bonding Material: Height Top Insulation Layer: Top Insulation Size and Thickness: FT. Top Insulation Fastener/Bonding Material: C� r Mean Base Sheet(s)&No.of Ply(s): Roof Base Sheet Fastener/Bonding Material: Height i Ply Sheet(s)'&No.of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: ; I i ST. LUCIE WORKS Section D(Steep Slope Roof System) Roof System Manufacturer: BLS` Gop.N .l I Notice of Acceptance Number: Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations): Zone 1: S Zone 2e:=Lo-LZone 2ri!:" O rZone 2r:��•7Zone 3e:L`t=3 Zone 3r: I DecEcTYpe` I Type Underint: Rolf Stope: Insulaffain I Ridgy ltent�a an7 fastener Type :Spacing: �. t` pus ��-� s uL I Adhesive'TYpe !) A. I I Type Cap Sheet N Mean Roof Height: f L Rolf Covering: i I Type&Sm Drip Ems: I i I I ST. LUCIE WORKS Section E(Tile Calculations) For Moment based tile systems;choose either Method 1 or 2.Compare the values for Mrwith the values from Mf.If the Mf values are greater than or equal to the Mrvalues,for each area of the roof,then the the attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: Product Approval.M - [f '. (Zone 2e: ]� a _�-11 Product'Approval Mf L (Zone 2n: Xx- _3-W;: Product.Approval Mf, (Zone 2r: X1, _ =MQ: =flie Product Approval Mr (Zone 3e: XX = LV =Mo.- Product lApproval Mf (Zone 3r: M-9, Product'Approval Mr Method 2"Simplified Tile Calculations Per Table Below" Required Moment of Resistance(Mr)From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' . 30' I 40' 2:12 34.4 36.5 38.2 39.7 + 42.2 3:12 32.2 34.4 36.0 37.4 I 39.8 4:12 30.4 32.2 33.8 '35.1 I _37.3 5:12 28.4 30.1 31.6 32.8 I 34.9 6:12 26.4 28.0 29.4 30.5 I 32.4 7:12 24.4 25.9 27.1 28.2 I 30.0 *Must be used in conjunction with a list of moment based tile systems • For Uplift based the systems use Method 3.Compare the values.for F'with the values for Fr If the F'values are greater than or equal to the Fr values,for each area of the roof,then the tile attachment method is:acceptable. Method 3"Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L =x W:=`_) -W: cos r =Fri Product Approval F' (Zone 2e: x L =x W:= )-W: cos r =Fr2e Product Approval F' (Zone 2n: x L =x W:= )-W: cos r =Fr2n Product Approval F' (Zone 2r: x L =x W:= )-W: cos r =Fr2r Product Approval F' (Zone 3e: x L =x W:= )-W: cos r =FBe Product Approval F' (Zone 3r: x L =x W:=`)-W: cos r =Frar ,Product Approval F' Where to Obtain Information Description Symbol Where to find) From applicable table in RAS 127 or by ani engineering analysis Design Pressure Zones 1,2e,2n,2r,3e,3r prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier z Product Approval Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L=length W=width Product Approval All calculations must be submitted to the building official at the time of permit application.