Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL 2020 4/8/2021 Florida Building Code Online " a . / 4HK wt BCIS Home Login User Registration Hot Topics Submit Surcharge Stats&Facts I Publications Contact Us I BCIS Site Map Lirj{is' Seatift b 1� _ Product Ap proval r � �.USER:Public User d-, W Product Approval Menu>Product or Application Search>Application List Search Criteria Reflne Search - - - Code Ve►sion 2020-FL#- ALL -- - Application Type ALL Product Manufacturer Beacon Sales Acquisitions, Inc. c/o Owens Corning Roofing and Asphalt LLC Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results-Ap lications_ - - I;FL* Type Manufac carer, ,- _- .Validatedtus FL22259-R3. Revision 'Beacon Sales Acquisitions, Inc. c/o Owens Corning Roofing and Asphalt LLC Steven M. Urich, PE Approved Category: Roofing 9 (717) 317-8454 _ 'Subcategory: Underlayments FL29456-111 Revision Beacon Sales Acquisitions, Inc. c/o Owens Corning Roofing and Asphalt LLC Steven M. Urich PE Approved History Category: Roofing (717)317-8454 l -Subcategory: Roofing Accessories that are an Integral Part of the Roofing'System FL31963-111 Revision Beacon Sales Acquisitions, Inc. c/o Owens Corning Roofing and Asphalt LLC John W. Knezevich, PE Approved is Category: Roofing T(954) 772-6224 � Subcategory: Underlayments FL34539 New Beacon Sales Acquisitions, Inc. c/o Owens Corning Roofing and Asphalt LLC Steven M. Utich,PE !Approved 'Category: Roofing (717) 317-8454 Subcategory: Underlayments *Approved by DBPR:Approvals by DBPR shall be reviewed and ratified by the POC and/or the`Commission If necessary: Contact Us::2601-Blair Stone-Road;1allahassee.FL-32399 Phone:850-4_67-1824_ The State of Florida Is an AA/EEO employer.C�QlZy2ight.2007-2013-State af-Florida ::Privacv-Statement::Accessibll6v=Statement,::,Refu4Statement. Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact hfps://www.floridabuilding.org/pr/pr app Ist.aspx 1/2 4/8/2021 Florida Building Code Online ' the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under, Chapter 45S,F.S.must provide the Department with an email address if they have one.The emalis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an emall address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click bgM. Prodiuct`Apprdvil Accep � ® eCArsE Credit Card Safe https://www.floridabuilding.org/pr/pr app Ist.aspx tiz G RE Ff K c/o OWENS CORNING SALES ACQUISITIONS,INC. RNING ROOFING AND ASPHALT LLC TECHNICAL,SERvims,LLC TRI-BUILT Granular Underlayment LIMITATIONS_ 1) This evaluation)report is not for use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance in not within scope of this evaluation. 4) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturers published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) The underlayment may be used as described in other current FBC product approval documents. 7) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. 8) The underayment shall not be installed over existing roof coverings. 9) The underayment shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. The first layer shall cover the entire bottom edge of the deck. End laps shall be staggered a minimum of 24,inches from the preceding course. 10) The underlayment shall be exposed on the roof deck for a maximum duration of 30 days. 11) All products Listed in this report shall be manufactured under a quality-assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code,71h Edition(2020)as evidenced in the referenced documents submitted by the named manufacturer. %`,`��r<uu rilr�f��b PRY R: p % 2020.10.1 `"t' 15.45.22 No 74021 � _ •� - • 0400' STATE OF ::4l: 1 v, ���' Zachary R. Priest, P.E. �11i�t��;• R t Q••'(yN Florida Registration No.74021 Organization No.ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will It acquire,a financial interest in any company manufacturing or distributing products under this evaluation. I CREEK Technical Services,LLG is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does nit have,nor will acquire,a financial Interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT i OCR20001 EL34539 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC off any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty,installation,recommended use, or other product attributes that are not specifically addressed herein. CerttfrCafe of Authorization No. 29824 CR EEt 17520 Edinburgh Drive Tampa,FL 33647 TECHNICAL SERVICES, LLC (873)480-3421 EVALUATION REPORT FLORiDA BUILDING CODE,7T"EDITION(2020) Manufacturer: BEACON SALES ACQUISITIONS,INC. Issued October 14, 2020 c/o OWENS CORNING ROOFING AND ASPHALT LLC 1 Owens Coming Parkway Toledo,OH 43657 (800)438-7465 www.owenscomina:com Manufacturing Location: Houston;TX Brentwood,NH Quality Assurance: PRI Construction Materials Technologies,LLC(QUA9110) I SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1,i507.1.1.1 Properties: Physical properties REFERENCES i Entity i Report No.,• Standard Year PRI Construction Materials Technologies(TST6049) OCF=294--02-01 ICC-ES AC 188' 2012 1 ICC-ES AC 48 2012 PRI Construction Materials Technologies(TST6049) OCF-338-02-01 ASTM D 1970 2015a 'Determined to be equivalent to ASTM D 226-09,Type II PRODUCT DESCRIPTION TRI-BUILT Granular A self-adhered underlayment used as an alternative to ASTM D 226,Type II roofing felt. Underlayment The undehayment is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness I of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. See manufacturer's installation instructions for further detail. OCR20001 _ FL34539 . Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor,imply warranty,installation,recommended use,or other product attributes that are not specifically addressed herein. CREEKBEACON SALES ACQUISITIONS,INC. Lw i 1 c/o OWENS CORNING ROOFING AND ASPHALT LLC TECHNICAL SERVICES, LLC TRI-BUILT Granular Underlayment APPLICATION Roof Deck: The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8"gap at abutting joints. Min.slope: 2:12 or in accordance in with FBC Application: Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment installation shall comply with FBC Table 1507.1.1.1. The underlayment shall be installed with the roll length parallel to the eave,starting at the eave fold the underlayment away from eave onto Itself. The underlayment shall be installed direct-to-decking with the lower release backer removed and pressed firmly into place to ensure complete contact with the deck. Repeat with upper release backer. Overlap successive courses with minimum 3"side laps and minimum 6"staggered end laps. In steep-slope applications (>6:12), it is permissible to nail the underlayment 12- inches on-center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underayment). For valley applications, the roll shall be applied centered along the valley prior to installing the underlayment at the eave and overlapped a minimum of 6-inches. For eave protection, the underlayment should extend to a point 18-inches beyond the interior wall. Min.Application Temperature: 40°F;Contact the manufacturer when installing at temperatures below the minimum application temperature. Allowable roof coverings: Mechanical attachment of asphalt shingles and slate shingles shall be permitted in accordance with the FBC. OCR20001 FL34539 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. n