HomeMy WebLinkAboutPRODUCT APPROVAL - ASPHALT SHINGLES i IyY •°�
I Ric
7"
7,1
BCIS Home Log In User Registration Hat Topics SubmitSufcbatge Stats&Facts ftbllcatlons Contact Us BM Site Map Links Search
Florida
�Yc'rl Product Approval RECEIVED
° USER:Public User
Product Approval Menu_>Product or Application Search>Application List>AppBotion Doj A N 2 2022
[ _ l FL39780 St.Luce County
Application Type New Permittinr
Code Version File Copy 2020
Approved Application Status �7•�
*Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary".
Comments
Archived
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany,NJ 07054
(800)766-3411
mstieh@gaf.com
Authorized Signature Michael Stieh
mstieh@gaf.com
Technical Representative Michael Stieh
° Address/Phone/Email 1 Campus Drive
Parsippany,NJ 07054
(973)628-3000
mstieh@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Product Evaluation Entity
Evaluation Entity Miami-Dade BCCO-EVL
Quality Assurance Entity Miami-Dade BCCO-CER
Quality Assurance Contract Expiration Date 02/21/2022
Validated By Miami-Dade BCCO-VAL
Certificate of Independence
Referenced Standard and Year(of Standard) Standard Year
ASTM D3462 2010
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option C
http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtRCXRA8XX... 10/11/2021
Date Submitted 09/16/2021
Date Validated 10/06/2021
Date Pending FBC Approval
Date Approved 10/11/2021
Summary of Products
FL# Model,Number or Name Description
39780.1 Timberline HD@,Timberline@ Fiberglass reinforced asphalt roof shingle with a laminate
Natural Shadowe,Timberline profile.
NS@,Timberline American@
Harvest@,Timberline AH@,
Timberline@ HDZ—,Timberline
CS@ and Fortitude—
Limits of Use Installation Instructions
Approved for use in 14VHZ:Yes FL39780 RO iI 19-0312 04 Ddf
Approved for use outside HVHZ:No Verified By:Miami-Dade BCCO-EVL
Impact Resistant.No Created by Independent Third Party:
Design Pressure:N/A Evaluation Reports
Other. FL39780 RO AE 19-0312 04 Ddf
Back Next -
Contact Us::2601 Blair Stone Road.Tallahassee Fl.32399 Phone:8S0-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida ::Privacy S tement::Accessfbirfty Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic -
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.139S.'Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
dirk here
Product Approval Accepts:
� Lr_
Credit Card
Safe
I
http://www,floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgtRcxRA8XX... 10/11/2021
i
I
NIIANII-DADE COUNTY
MIA_ MI•DADE PRODUCT CONTROL SECTION
° M �11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) owww.miamidade.sov/economy
GAF
1 Campus Drive
Parsippany,NJ 07054
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami(Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur- the expense of such testing and the AHJ may immediately
revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
i
This product is approved as described herein,and has been designed to comply with the Florida.Building Code
including the High Velocity Hurricane Zone of the Florida Building Code. i
DESCRIPTION: GAF Timberline HD®,Timberline®Natural Shadow®,Timberline®NS,Timberline®American
Harvest®,Timberline®AH,Timberline®HDZTM,Timberline®CS and Fortitude®Shingles
9
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise rioted herein.
i
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales,advertising or any other purposes shall automatically terminate this NOA."Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of thejNOA is displayed,then it shall be done
in its entirety.
i
INSPECTION:A copy of this entire NOA shall be provided to the user by the(manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Ofcial. '
This NOA renews and revises NOA# 16-0811.11 and consists of pages 1 through 7.
The submitted documentation was reviewed by Freddy Semino
NOA No.: 19-0312.04
Mi•ruw�coutvTr Expiration Date:02/21/22
Approval Date:01/09/20
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category Roofing
Sub-Category: Asphalt Shingles
Materials: Laminate
Deck Type: Wood
SCOPE
This approves GAF Timberline HD®,Timberline®Natural Shadow',Timberline NS®,Timberline American®
Harvest®,Timberline AH®,Timberline®HDZTM,Timberline CS®and Fortitud6m Shingles as manufactured by
GAF as described in this Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
Specifications
GAF Timberline HD® 13 1/4"x 39 3/8' TAS 110 Fiberglass reinforced heavy weight asphalt roof
Manufacturing shingle,with a laminate profile
Locations#1,2,3,4,5,6,7
GAF Timberline®Natural 13 1/a'x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof
Shadow®and Timberline®NS shingle,with a laminate profile
Manufacturing
Locations#1,2,3;4,5,6,7
GAF Timberline®American 13 1/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof
Harvest® shingle,with a laminate profile
Manufacturing
Locations#2,4,6,9
GAF Timberline®AH 13 1/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof
Manufacturing shingle,with a laminate profile
Locations#2, 4, 6, 9
GAF Timberline®HDZ7 13 1/4"x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof
Manufacturing shingle,with a laminate profile
Locations#1,2,3,4,5,6,7,8,9
GAF Fortitude® 13 1/a'x 39 3/8" TAS 110 Fiberglass reinforced heavy weight asphalt roof
Manufacturing shingle,with a laminate profile
Location#4
GAF Timberline®CS 13 1/4,x 39 3/8' TAS 110 Fiberglass reinforced heavy weight asphalt roof
Manufacturing shingle,with a laminate profile
Location#9
MIAMI•DADE COUNTY
NOA No.: 19-0312.04
.... , Expiration Date: 02/21/22
Approval Date: 01/09/20
Page 2 of 7
MANUFACTURING LOCATION
1. Tampa,FL
2. Michigan City,IN
3. Baltimore,MD
4. Myerstown,PA
5. Ennis,TX
6. Tuscaloosa,AL
7. Dallas,TX
S. Shafter,CA
9. Fontana,CA
I i
� 1
i
i
i
I
I
I
I
MIAMI•DADE COUNTY NOA No.: 19-0312.04
Expiration Date:02/21/22
Approval Date: 01/09/20
Page 3 of 7
EVIDENCE SUBMITTED
Test Agency Test-Identifier.._ Test Name/Report Date
Underwriters Laboratories,LLC ASTM D3462 4788932264 12/13/19
Underwriters Laboratories,LLC ASTM D3462 4788717529 01/31/19
Underwriters Laboratories,LLC ASTM D3462 4787344101 07/25/16
Underwriters Laboratories,Inc. ASTM D3462 11CA48924 10/22/11
Underwriters Laboratories,Inc ASTM D3462 IOCA21994 04/22/11
Underwriters Laboratories,Inc ASTM D3462 IOCA28717 07/26/11
Underwriters Laboratories,Inc. ASTM D3462 05CA47541 11/10/06
Underwriters Laboratories,Inc. ASTM D3462 06CA31580 11/30/06
PRI Asphalt Technologies,Inc. ASTM D3462 GAF-101-02-02 11/02/05
Underwriters Laboratories,Inc. ASTM D3462 06NK05159 08/09/06
PRI Asphalt Technologies,Inc. ASTM D3462 GAF-098-02-02 I 1/08/05
Underwriters Laboratories,Inc. ASTM D3462 02NK41809 08/11/02
Underwriters Laboratories,Inc.Center for ASTM D3462ASTM 03NK26444257989 10/17/03
Applied Engineering. . D3462 05/13/97
Underwriters Laboratories,LLC TAS 107 4789225984 11/1/19
Underwriters Laboratories,LLC TAS 107 4788717529 01/31/19
Underwriters Laboratories,Inc. TAS 107 01NK45803 04/13/94
Underwriters Laboratories,Inc. TAS 107 06NK05159 08/09/06
Underwriters Laboratories,Inc. TAS 107 04NK04273 02/20/04
Underwriters Laboratories,Inc. TAS 107 05CA42840 11/11/05
Underwriters Laboratories,Inc. TAS 107 02NK41811 11/11/02
Underwriters Laboratories,Inc. TAS 107 03CA35209 10/17/03
Underwriters Laboratories,Inc. TAS 107 04CA13850 08/30/04
Center for Applied Engineering TAS 100 257989 04/01/97
PRI Asphalt Technologies,Inc. TAS 100 GAF-912-02-01 12/17/18
PRI Asphalt Technologies,Inc.- TAS 100 GAF-044-02=01 01/13/04
PRI Asphalt Technologies,Inc. TAS 100 GAF-098-02-01 11/08/05
PRI Asphalt Technologies,Inc. TAS 100 GAF-101-02-01 11/09/05
PRI Asphalt Technologies,Inc. TAS 100 GAF-116-02-02 03/23/06
PRI Asphalt Technologies,Inc. TAS-100 ELK-083-02-01 10/16/02
ELK-0 84-02-01 10/15/02
ELK-085-02-01- 10/14/02
ELK-086-02-01 10/24/02
ELK-087-02-01 10/21/02
ELK 088-02-01 10/16/02
ELK-107-02-01 10/09/03
ELK-108-02-01 10/09/03
ELK-109-02-01 10/09/03
NOA No.: 19-0312.04
MIAMIuuum C OUNTY Expiration Date: 02/21/22
Approval Date: O1/09/20
Page 4 of 7
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
i
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail'A', attached.
5. Nailing shall be in compliance with Detail'B',attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade
County Product Control Seal as shown below.
MIAMI-DADE COUNTY
a
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
i
i
i
i
i
NOA No.: 19-0312.04
MIAMI-DADECOUNTY Expiration Date:02/21/22
Approval Date: 01/09/20
Page 5 of 7
DETAIL A
COURSE LAYOUT
DECK
-" FULL
I
5th
i
17"OFF 4th
j
11"OFF 3rd
6"OFF 2nd
I j
FULL ' 1st i
5-5/8"Exposure
NOA No.: 19-0312.04
MIAMI•DADE COUNTY
Expiration Date: 02/21/22
Approval Date: 01/09/20
Page 6 of 7
DETAIL.B
OVERALL DIMENSIONS AND NAILING PATTERN
FOR TIMBERLINE HD® TIMBERLINE® NATURAL SHADOW® AND TIMBERLINE®NS
1
39-3/811
(t m)
14-1/2"-17-1/2" 14-1/2"-17;:1/2"
(368-445mm) (368-445rtim) 81I guide line
13-1/4" 9-1/2" 6-1/2"-9-1/2"
(163.241mm) (1ss-zslmm) J 53/4"-6-1/4"
(146mm-159mm)
(337mm) 1n"-2-1/2' -� _♦ ~ from bottom of shingle
(13-64
elf seal
adhesive
on back
ENHANCED NAILING PATTERN - six nails per. hingle*
required by some local codes and required for enhanced wind coverage on certain products.
See limited warranty for details.
These shingles MUST be nailed a nominal 6" (152mm)from bottom of
of shingle, above the cut outs, as shown. Nails must not tie exposed.
i
OVERALL DIMENSIONS AND NAILING PATTERN
FOR TIMBERLINE®HDZTm,TEwBERLINE®CS,TIMBERLINE®AH,AND
FORTITUDE®
39-3/8" (1 m) l
I 1
14-1/2"-17-1/2 368 mm-445 mm) 14-12"-17-1/2"(368 rnm-445 mm)
6-1/2"-9-if1"(165 mm-241 mm) 6-1/2'-9-1/2'(165 mm-241 mm)
V?-2-1/2'(13 mm-64 mm) 1/2'-2-1J2'(13 m-64 mm)
13-1/4"
337mm
( )
TARGET
...... ......... ..................
NAIL ZONE
5-13/16"-6-1/4" 5-13/16"-7-5/8"
(148 mm-159 mm) (148 mm-194 mm)
For Mansard Roofs
1
END OF THIS ACCEPTANCE
NOA No.: 19-0312.04
Mlaru nA�e couNrr Expiration Date:02/21/22
Approval Date:01/09/20
Page 7 of 7
i
© 2
� � e
•
Timberline®HDr Shingles
Benefits: Product details:
■ LayerLocr Technology—Proprietary durability,strength, and exceptional Product/System Specifics
technology mechanically fuses the wind uplift performance. ■ Fiberglass asphalt construction
■ Dimensions(approx.):13'A x 39 3/e"
common bond between overlapping ■ StainGuard®Algae Protection— ( )
shingle layers. ■ Exposure:5 am(143 mm)
Helps protect the beauty of your ■ Bundles%Square:3
■ Up to 99.9%nailing accuracy— roof against unsightly blue-green ■ Pieces/square:64
The StrikeZone'"nailing area is so algae discoloration. ■ StainGuard'Algae Protection'
■ Hip/Ridge:TimberTex";TimberCrest ;
easy to hit that a roofer placed 999 1 ■ High Performance—Designed Seal-A-R;dgel:ZaRidge;Rldglass"
out of 1,000 nails correctly in our test. with Advanced Protection)Shingle ■ starter:Pro-Start":Quickstart'l;
"'
■ WindProven'"Limited Wind Technology. WeatherBlocker
Warranty—When installed with Applicable Standards&Protocols:
■ Seamless compatibility—The new ■ UL Listed to ANSI/UL 790 Class A
the required combination of GAF ■ State of Florida approved
Accessories,Timberline®HDZ"' Timberline"'HDZn Shingles are com- x Classified by UL in accordance with
Shingles are eligible for an industry patible with traditional Timberline HDe [CC-ES AC438
Shingles for the same look and feel ■ Meets ASTM D7158,Class H
first: a wind warranty with no ■ Meets ASTM D3161,Class F
maximum wind speed limitation.2 homeowners and contractors Qely . Meets ASTM D3018,Type 1
on for beauty and endurance. ■ Meets ASTM D34625
■ Our legendary Dura Grip'sealant ■ ICC-ES Evaluation Reports
■ Perfect Finishing Touch—For the ESR-1475 and ESR-3267
pairs with the smooth microgranule best look, use TimberTex5 Premium ■ Meets Texas Department of Insurance
surface of the StrikeZone'"'nailing Ridge Cap Shingles or TimberCrest"" Requirements
area for fast tack.Then,an asphalt-to- ■ ENERGYISTAR£Certified(White Only)
asphalt monolithic bond cures for Premium SBS-Modified Ridge (U.S.Only);Rated by the CRRC:Can
Cap Shingles. be used,to comply with Title 24 cool
Availability:
requirements
Colors �e Availability: Results based on study conducted by Home Innovation Research Labs,
an independent research lob,comparing installation of Timberline HD°
Shingles ro Timberlines HDZ"Shingles on a 16-square roof deck using
standard 4-nail�nailing pattern under controlled laboratory conditions.
Actual results may vary.
°15-year WindPrpven"limited wind warranty on Timberlinev HDZ"
Shingles requires the use of GAF starter strips,roof deck protection,
ridge cap shingles.and leak border or attic ventilation.See GAF Roofing
rIT
.e i •, e e e_ System Lf'miledlWmrontyfor complete coverage and restrictions.Visit
. _ .' - ^# .` gaf.com/LRS for qualifying GAF products.
StoinGuorO algae protection is available only on shingles sold in
P packages bearing the StainGuard"logo.Products with S1ainGuord°
d'
algae protection are covered by a 10-year limited warranty against
blue-green algae discoloration.See GAF Shingle&Accessory limited
Warmntyfor complete coverage and restrictions.
'To be mixed on one roof,Timberline°HDZ'Shingles and Timberline HD*
o ... ,. e j�,. e: ! e 'GreenShingles must have matching 6-digit codes found on the end of the bundle.
-- -— - --!""���'■� When mixed,always use Timberline HP'installation instructions.
'Periodically tested by independent and internal labs to ensure
compliance with ASTM 03462 at time of manufacture.
. °Lifetime refers to the length of warranty coverage provided and means
., as long as the original individual owner(s)of a single-family detached
residence[or eligible second ownei(s)]owns the property where the
. v Patriot . .e qualifying GAF products are installed.For other owners/structures,Lifetime
coverage is not applicable.lifetime coverage on shingles requires use of
- - - - - GAF Lifetime shingles only.See GM Shingle&Accessory Limited Warranty o
a for complete average and restrictions.Lifetime coverage an shingles and
accessories requires use of any GAF Lifetime Shingle and any 3 qualifying
GAF accessories.See GAF Roofing System Limited Wmrontyfor complete o
- coverage and estrictions.Visit gal.coMLRS for qualifying GAF products.
Note:It is difgculi to reproduce the color clardy and actual color blends N
of these products.Before selecting our color, lease ask to see several
dr P Y P
-
-- - - lull-size shingles.
Wu.M W'sana{c$Awnan' o
�m,v wonn,+uewnn..usrn We protect what matters most-
ItIXHInI'.IT1ttXlT5
I