Product Approval
IUI-f 7�79'1
d Florida
@ USER Public User
Product Approval Menu>Product or Aplilicatian Search>Anolication Usk>Application Detail
RECEN ED
FL# FL10626-1122
Application Type Revision
Code Version nr-, I le Copy 2020 J A N 1 -93 2,1'-,'2
Application Status Approved St.LUClo County
Permitting
Comments
Archived
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany,NJ 07054
(800)766-3411
mstieh@gaEcom
Authorized Signature Robert Nieminen
lreith@nemoetc.com
Technical Representative William Broussard
Address/Phone/Email I.Campus Drive
Parsippany,NJ 07054
(800)766-3411
Tech n icalQuestionsGAF@ gaE com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report 7 Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nleminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/17/2021
Validated By John W. Knezevich,PE;
Validation Checklist Hardcopy Received
Certificate of Independence FL10626 R22 COI 2021 01 COI NIEMINEN.0—f
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D4533(tear) 2015
ASTM D4798(weathering) 2011
ASTM D4869(water transmission) 'i 2016
ASTM D5035(tensile) 2011
ASTM D6164 2011
ASTM D6757 2016
FM 4474 2011
FRSA[TRI,6th Edition 2018
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 06/09/2021
Date Validated 06/11/2021
Date Pending FBC Approval 06/17/2021
Date Approved 08/10/2021
Date Revised 12/16/2021
Summa of Products
FL# Model,Number or Name Description
10626.1 GAF Roof Underlayments for Roofing Underlayments for use in sloped roof systems
use in FBC non-HVHZ
jurisdictions
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10626 R22 II 2021 06 09 FINAL ER GAF UNDERLAYMENTS FL10626-
Approved for use outside HVHZ:Yes R22.pdf
Impact Resistant:N/A Verified By: Robert Niemien 59166
Design Pressure:+N/A/-442.5 Created by Independent Third Party:Yes
Other:1.)The design pressure noted in this Evaluation Reports
application relates to one particular FL10626 R22 AE 2.021 06 09 FINAL ER GAF UNDERLAYMENTS FL10626-
underlayment system.Refer to ER Section 5.8.3 R22.pdf
for details.2.)Refer to ER Section 5 for other Created by Independent Third Party:Yes
Limits of Use.
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.if you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455,F.S.,please dick here.
Product Approval Accepts:
_rM: Kew-11 MAR E::h_c:1 E -
Credit Card
Safe
I
NEMO etc.
Certificate of Authorization#32455
i
353 Christian Street,Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
.O.
GAF Evaluation Report 01506.04.08-1122
1Campus Drive FL10626-R22
Parsippany, NJ 07054 Date of Issuance:04/25/2008
(800)766-3411 Revision 22:06/09/2021
SCOPE: j
This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
I .
P.E.for use of the product underthe Florida Building Code and Florida Buildin Code Residential Volume. The products
p g g� I
described herein have been evaluated for compliance with the 7to Edition(2020) Florida Building Code sections noted
herein.
i
DESCRIPTION: GAF Roof Underlayments for use in FBC non-HVHZ jurisdictions . I
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation,Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
i
Prepared by: _
Robert J.M.Nieminen,P.E. 7
,J' �,:..�,,�r%?:: �The facsimile seal appearing was authorized by Robert
Nieminen,P.E.on d6/09/2021.This does not serve as an
Florida Registration No.59166,.Florida DCAANE1983
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,lthe Designer of Record for any
project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2019 NEMO ETC,LLC
ONEMOletc.
ROOFING COMPONENT EVALUATION:
®•
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: GAF Roof Underlayments,as produced by GAF, have demonstrated compliance with the
following sections of the 71h Edition(2020)Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth
herein.
2. STANDARDS'
Section PropertV Standard Year
1504.3.1 Wind resistance FM 4474 2011
1507.1.1,1507.2.4,1507.2.9.2/ Material standard ASTM D1970 2015
R905.1.1,R905.2.8.2
1507.1.1.1(2&3,Exception), Tear Strength ASTM D4533 2015
1507.1.1.1(5)/R905.1.1.1(2&3,
Exception),R905.1.1.1(5)
1507.1.1.1(2&3,Exception), Tensile strength ASTM D5035 2011
1507.1.1.1(5)/R905.1.1.1(2&3,
Exception),R905.1.1.1(5)
1507.1.1.1(5)/R905.1.1.1(5) Liquid water transmission ASTM D4869 2016
1507.1.1/R905.1.1 Material standard ASTM D6757 2016
1507.3.3,R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
1507.11.2 Material standard ASTM D6164 2011
TAS 110 Accelerated Weathering ASTM D4798 2011
Enti Examination Reference Date
ERD(TST 6049) ASTM D1623&FRSA/TRI(Slippage) G34150.08.11 11/14/2011
ERD(TST 6049) ASTM D6164(GA) G40630.01.14-2B 01/07/2014
ERD(TST 6049) ASTM D6164(GA) G46160.09.14-3A 09/09/2014
ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-3 03/01/2017
ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-4 03/01/2017
ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-1 03/08/2017
ERD(TST6049) ASTM D1970(IN) GAF-SC16440.12.17 12/31/2017
Intertek(TST 1558) ASTM D4869(Dadra,India) F8549.02-106-18 11/08/2016
NEMO(TST 6049) Physical Properties(ON) 4q-GAF-I9-SSMBB-03.A 05/13/2019
NEMO(TST6049) ASTM D1970 4j-FTS-20-SSUDL-01.A 12/01/2020
NEMO(TST 6049) ASTM D4798,TAS 103 4j-GAF-20-SSUDL-02.A 03/15/2021
NEMO(TST6049) ASTM D4798 4j-FTS-2I-SSUDL-02.A 06/09/2021
PRI(TST 5878) ASTM D1970(IN) GAF-324-02-01 11/30/2011
PRI(TST 5878) ASTM D226(OK) GAF-339-02-01 03/13/2012
PRI(TST 5878) ASTM D4798(NC) GAF-349-02-01 07/03/2012
PRI(TST 5878) Wind Uplift GAF-434-02-01 09/16/2013
PRI(TST 5878) Wind Uplift GAF-434-02-03 09/16/2013
PRI(TST 5878) Wind Uplift GAF-434-02-04 09/16/2013
PRI(TST 5878) ASTM D4533(various) GAF-818-02-01 12/05/2017
PRI(TST 5878) ASTM D1970(AL) MSA-047-02-01 04/11/2018
PRI(TST 5878) ASTM D4533(LA) GAF-826-02-01 06/4/2018
PRI(TST 5878) ASTM D4533(Dadra,India) GAF-847-02-01 06/4/2018
PRI(TST 5878) ASTM D4533(Dadra,India) GAF-914-02-01 04/10/2019
PRI(TST5878) ASTM D4533,D5035(VA) 376T0012 07/15/2019
PRI(TST 5878) ASTM D4533(Umerkui Kilvani,India) 376T0018 07/31/2019
PRI(TST 5878) ASTM D4533(Parzai,India) 376T0018 07/31/2019
MEMO ETC,LLC Evaluation Report 01506.04.08-R22
Certificate of Authorization N32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22:06/09/2021
Page 2 of 9
I
n ' I
i
I
I NNEMOletc.
Enti Examination Reference .Date
PRI(TST 5878) ASTM D1970(AR) 37010032 10/22/2019
PRI(TST 5878) ASTM D226(S-CA) 376TOO54 02/18/2020
PRI(TST 5878) ASTM D4533(Gujarat,India) 376TOO58 02/18/2020
PRI(TST 5878) ASTM D5035(various) 376TO103 09/11/2020
PRI(TST 5878) ASTM D4533,D5035(Rajasthan,India) 376T0111 j 12/22/2020
PRI(TST 5878) ASTM D4533,D5035(Gujarat,India) 376TO113 J 12/22/2020
UL(TST 1740) ASTM D6757(TX) 02NK22569 06/04/2002
PRI(TST 5878) ASTM D5035(Gujarat,India) 376TO146 03/11/2021
PRI(TST 5878) ASTM D4533,D5035(Rajasthan,India) 376TO161 05/07/2021
UL(TST 1740) ASTM D6757(NC) 1ONK11990 05/18/2011
NEMO ETC Traceability FBC Cross-Listing 1 04/22/2020
NEMO Traceability FBC Cross-Listing 04/08/2021
UL,LLC(QUA 9625) Quality Control Service Confirmation 03/23/2021
UL,LLC(QUA 9625) Quality Control Service Confirmation(AL) 05/04/2020
UL,LLC(QUA 9625) Quality Control Florida BCIS Current
I I
PRODUCT ! •
Product Material Standard Plant(s)
4.1 GAF Extended Dry-In Membrane ASTM D1970 Langley,BC Canada
Liberty'SBS Self-Adhering Base/Ply Mt.Vernon,IN
4.2 Sheet ASTM D1970 Savannah,GA
4.3 StormGuard®Film-Surfaced Leak Barrier ASTM D1970 Mt.Vernon,INSavannah,GA
Arkadelphia,AR
4.4 WeatherWatch®Mineral-Surfaced Leak ASTM D1970 Mt.Vernon,IN
Barrier Savannah,GA
Tuscaloosa,AL
4.5 Deck-Armor""Premium Breathable Roof 1507.1.1.1(2&3,Exception)/ Dadra,India
Deck Protection R905.1.1.1(2&3,Exception)
Dadra,India
„
FeltBusterm Synthetic Roofing Felt 1507.1.1.1(2&3,Exception), j Gujarat,India(CPP)Rajasthan,India
4.6 (formerly FeltBuster—High-Traction synthetic 1507.1.1.1(5)/R905.1.1.1(2&3, (MIP)Rajasthan,India
Roofing Felt) Exception),R905.1.1.1(5)
Richmond,VA
Spartanburg,SC
4.7 Shingle-Mate®Roof Deck Protection ASTM D226,Type II(Table 1) Pryor,OK
Shafter,CA
I
4.8 StormSafeTM Anchor Sheet 1507.1.1.1(2&3,Exception)/ ! North Bay,ON
R905.1.1.1(2&3,Exception)
Tiger PawTM Premium Roof Deck Dadra India
2&3,Exception)1507.1.1.1 /
4.9 Protection(formerly Tiger Pow-Roof Deck ( Gujarat,India
Protection) R905.1.1.1(2&3,Exception) Parzai,India
Umerkui Kilvani,India
4.10 VersaShield®Fire-Resistant Roof Deck ASTM D6757 Conover,NC
Protection
4.11 Ruberoid®Mop Granule ASTM D6164 I Savannah,GA
FRSA/TRI09-18
4.12 Ruberoid®Mop Granule FR ASTM D6164 Savannah,GA
FRSA/TRI09-18 I
1
I
NEMO ETC,LLC Evaluation Report 01506.04.08-1122
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-1122
GAF Roof Underlayments Revision 22:06/09/2021
Page 3 of 9
I
I
I
I
I
N.NEM01 etc.
s
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
.FBC Section: 1507.2 1507.3 1507.4 and 1507.5 1507.7 1507.8 and 1507.9
Clay and Concrete Tile Metal Slate or Wood
ment Underla Asphalt
Y Mechanical Adhesive- Slate-Type
Shingles Panels Shingles Shingles Shakes
Attach Set Shingles
Yes Yes
GAF Extended Dry-In Membrane Yes No No Yes Yes Yes Goint strips, Goint strips,
1507.1.1.3/ 1507.1.1.3/
R905.1.1.3) R905.1.1.3)
Liberty—SBS Self-Adhering Yes Yes
Yes No No No No No Goint strips, (joint strips,
Base/Ply Sheet 1507.1.13/ 1507.1.1.3/
R905.1.1.3) R905.1.1.3)
Yes Yes
StormGuard®Film-Surfaced Leak
Barrier Yes No No Yes Yes Yes 1507.1..1.3/ 1507.1.13/
R905.1.13) R905.1.1.3)
WeatherWatch®Mineral-Surfaced Yes Yes
Yes No No No No No Goint strips, Goint strips,
Leak Barrier 1507.1.1.3/ 1507.1.1.3/
R905.1.1.3) R905.1.1.3)
Deck-Armor'"Premium Breathable Yes No No Yes Yes Yes No No
Roof Deck Protection
FeltBuster—Synthetic Roofing Felt Yes No No No No No No No
Shingle-Mate®Roof Deck
Yes No No No No No No No
Protection
Tiger Paw-Premium Roof Deck Yes No No Yes Yes Yes No No
Protection
VersaShield®Fire-Resistant Roof
Yes No No No No No No No
Deck Protection
Yes Yes
Ruberoid®Mo Granule No (Cap Sheet in
P (Cap Sheet in 2-ply system) No No No No No
2-ply system)
See 5.6.1
Yes Yes
Ruberoid®Mop Granule FR No (Cap Sheet in (Cap Sheet in No No No No No
2-ply system)
2-ply system)
See 5.6.1
MEMO ETC,LLC Evaluation Report 01506.04.08-1122
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-1122
GAF Roof Underlayments Revision 22:06/09/2021
Page 4 of 9
ONEMOjetc.
5.6.1 Adhesive-set is limited to use of following underlayment/tile-adhesive combinations.
TABLE 1A:ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE CO(VIBINATIONS1
Underlayment Adhesive Florida Product Approval
Ruberoid®Mop Granule;Ruberoid®Mop Granule FR Dupont`Tile Bond—Roof Tile Adhesive" FL22525
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Prime' Substrates
GAF Extended Dry-In Membrane self-adhering None j plywood
Liberty—SBS Self-Adhering Base/Ply Sheet
StormGuard®Film-Surfaced Leak Barrier self-adhering (Optional) plywood
ASTM D41
Weather Watch®Mineral-Surfaced Leak Barrier I
Liberty—SBS Self-Adhering Base/Ply Sheet
StormGuard®Film-Surfaced Leak Barrier self-adhering None ASTM D2I 6 felt,Type II
Weather Watch®Mineral-Surfaced Leak Barrier
LibertyTM'SBS Self-Adhering Base/Ply Sheet
StormGuard®Film-Surfaced Leak Barrier self-adhering ASTM D41 metal{fl�shing metal,valley metal,
etc.)
Weather Watch®Mineral-Surfaced Leak Barrier
Ruberoid®Mop Granule
hot asphalt ASTM D41 structural concrete
Ruberoid®Mop Granule FR I 1
Ruberoid®Mop Granule GAFGLAS®#80 Ultima—Base Sheet
hot asphalt None I
Ruberoid®Mop Granule FR or Ruberloid 20 Smooth
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlay l ents or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but—for mechanically attached base sheets-not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein-(for other underlayment systems).
� I
I
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Dieect-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,Appendix A,Table 1A or the
11
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
I
Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report 01506.04.08-1122
Certificate ofAuthorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.10626-1122
GAF Roof Underlayments Revision 22:06/09/2021
Page 5 of 9
I
I
I I
ONEMOletc.
#1 Maximum Design Pressure=-442.5 psf.
Deck: Min.21500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction
Base Sheet: GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Sheet,GAFGLAS#80 Ultima Base Sheet,GAFGLAS Ply 4,
Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312,Type IV hot asphalt at 20
to 25 Ibs/square.
Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
5.8.3.2 Mechanically-Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,Appendix A,Table 1A or the"
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section
2.2.10.1 of FM Loss Prevention Data Sheet 1-29(February 2020)for enhancements.
#2 Maximum Design Pressure=-45.psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 UltimaT" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga.,
min.1.25-inch long ring shank nails through 32 ga.,1-5/8-inch diameter tin caps spaced 9-inch o.c.
at the min.4-inch wide side laps and 9-inch o.c. at two(2),equally spaced,staggered center rows
in the field of the sheet.
Cap Sheet: Ruberoid®Mop Granule or Ruberoid°Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
#3 Maximum Design Pressure=-75 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 UltimaT" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga.,
min.1.25-inch long ring shank nails through 32 ga.,1-5/8-inch diameter tin caps spaced 8-inch o.c.
at the min.4-inch wide side laps and 8-inch o.c.at three(3),equally spaced,staggered center rows
in the field of the sheet.
Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25 Ibs/square.
#4 Maximum Design Pressure=-97.5 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 Ultimal Base Sheet or Ruberoid® 20 Smooth mechanically attached with 11 ga.,
min.1.25-inch long ring shank nails through 32 ga.,1-5/8-inch diameter tin caps spaced 4-inch o.c.
at the min.2-inch wide side laps and 4-inch o.c.at four(4),equally spaced center rows in the field
of the sheet.
Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type
IV hot asphalt at 20 to 25.lbs/square.
NEMO ETC,LLC Evaluation Report 01506.04.08-1122
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22:06/09/2021
Page 6 of 9
IRNEMO etc.
5.9 Exposure Limitations: j
TABLE 3: EXPOSURE LIMITATIONS
I Maximum
Underlayment Prepared Roof Cover Exposure
Installation Type (days)
s)
Deck-Armor—Premium Breathable Roof Deck Protection,FeltBuster—Synthetic
Roofing Felt,Shingle-Mate®Roof Deck Protection,StormSafe' Anchor Sheet,Tiger
Pawl Premium Roof Deck Protection,VersaShield®Fire-Resistant Roof Deck Mechanically attached 30
Protection,Liberty'°"SBS Self-Adhering Base/Ply Sheet,StormGuard®Film-Surfaced
Leak Barrier and WeatherWatch®Mineral-Surfaced Leak Barrier
GAF Extended Dry-In Membrane Mechanically attached 180
Ruberoid®Mop Granule and Ruberoid®Mop Granule FR Adhesive-set tile roof system 180
Mechanically attached UNLIMITED
5.10 Tile Slippage Limitations:When loading roof tiles on the underlayment, in direct-deck tile roof assemblies,the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4:TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE I STALLATIONS
Underlayment Tile Profile Staging Method Maximum Staging Slope
Flat Max.10-tile stack 4:12
Ruberoid®Mop Granule Flat Max.6-tile stack(4 over 2) 5:12
Lugged Max.10-tile stack 5:12
Ruberoid®Mop Granule FR Flat or Lugged Max.6-tile stack�4 over 2) 5:12
Lugged Max.10-tile stack 4:12
6. INSTALLATION:
6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below. 1
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application and prime the substrate(if applicable).1
6.3 Deck-Armor m Premium Breathable Roof Deck Protection or Tiger Paw'" Premium Roof Deck Protection:
6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBd 1507.1.1.1(2,Exception)
or 1507.1.1.1(3,Exception)or FBC Residential R905.1.1.1(2,Exception)or R905.1.1.1(3,Exception)for the type
of prepared roof covering to be installed,and the manufacturer's installatIion instructions. FBC requirements take
precedence over the manufacturer's installation instructions. {
� I
6.4 FeltBusterm Synthetic Roofing Felt:
6.4.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC11507.1.1.1(2,Exception),
1507.1.1.1(3,Exception) or 1507.1.1.1(5)or FBC Residential R905.1.1.1(2,Exception),i R905.1.1.1(3,Exception)
or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation
instructions. FBC requirements take precedence over the manufacturer's installation instructions.
I
NEMO ETC,LLC Evaluation Report 01506.04.08-RZ2
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22:06/09/2021
Page 7 of 9
I
I
i
I
IRMEMO i etc.
6.5 StormSafeTm Anchor Sheet: i.
6.5.1 StormSafell Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems.
6.5.2 Shall be installed in compliance with requirements for a synthetic underlayment in FBCI1507.1.1.1(2,Exception)
or 1507.1.1.1(3,Exception)or FBC Residential R905.1.1.1(2,Exception)or R905.1.1.1(3,Exception)for the type
of prepared roof covering to be installed,and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation instructions.
6.5.3 One the same day, install LibertyTM' SBS Self-Adhering Base/Ply; StormGuard® Film-Surfaced Leak Barrier or
WeatherWatch®Mineral-Surfaced Leak Barrier over the StormSaferm Anchor Sheet.
6.6 Shingle-Mate®Roof Deck Protection: j
6.6.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment(ASTM
D226,Type II)in FBC Table 1507.1.1.1 or FBC Residential Table 11905.1.1 it for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions. FBC ri quirements take precedence over the
manufacturer's installation instructions.
6.7 VersaShield®Fire-Resistant Roof Deck Protection:
6.7.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment(ASTM
D6757)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be
installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
6.8 GAF Extended Dry-In Membrane, Libertym SBS Self-Adhering Base/Ply Sheet,StormGuard®Film-Surfaced Leak
Barrier or WeatherWatch®Mineral-Surfaced Leak Barrier:
6.8.1 Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
6.8.2 Back-nailing is required. Back-nailing shall consist of Approved cap nails spaced 18-inch'o.c.,encapsulated within
min.4-inch side laps.
6.8.3 When installed over a mechanically attached, FBC Approved ASTM 1)226I Type II felt,inie felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
6.8.4 GAF Extended Dry-In Membrane,Liberty'SBS Self-Adhering Base/Ply Sheet,StormGuard®Film-Surfaced Leak
Barrier or WeatherWatch® Mineral-Surfaced Leak Barrier may be installed as a secondary water barrier using
minimum 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system.
6.9 Ruberoid®Mop Granule;Ruberoid®Mop Granule FR:
6.9.1 Shall be installed in compliance with requirements as an alternate to the"Hot Asphalt Applied Cap Sheet"in the
"Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth
Edition,and the manufacturer's installation instructions.
6.9.2 Refer to Section 5.8 herein for attachment limitations. j
6.9.3 Refer to Table 4 for the staging limitations.
i
I
{
NEMO ETC,LLC 1
Evaluation Report 01506.04.08-1122
Certificate opAuthorization✓t32455 7m EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22:06/09/2021
Page 8 of 9
I
ONEMOjetc.
7. -BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 611320-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
QUALITY
UL,LLC.—QUA9625;(414)248-6409;karen.buchmann@ul.com
-END OF EVALUATION REPORT-
I
I
I ,
I
I
I
i
I
I
I
d
I
I
I
NEMO ETC,LLC
Evaluation Report 01506.04.08-1122
Certificate of Authorization N32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-1122
GAF Roof Underlayments Revision 22:06/09/2021
I Page 9 of 9
i
I
FeltBuster° Synthetic Roofing Felt Specs
i
ABOUT SPECS DOCS VIDEOS
(HTTPS://WWW.GAF.COM/EN- (HTTPS://WWW.GAFCOM/EN- (HTrPS://WWW.OAF.COM/EN- (HTTPS://WWW.GAF.COM/EN-
US/PRODUCTS/,FELTBUSTER) US/PRODUCTS/FELT US/PRODUCTS/FELT " US/PRODUCTS/FELT
BUSTER/SPECIFICATIONS) BUSTER/DOCUMENTS) BUSTER/VIDEOS)
SPECIFICATIONS (ALL DIMENSIONS ARE NOMINAL)
ROLL LENGTH 250' (76.2 m)
ROLL WIDTH 48" (1.23 m)
ROLL WEIGHT 23 lb. (10.4 kg) j
APPROX.ROLL 10 squares/roll-1,000 sq.ft. (92.9 m2)
COVERAGE- (excludes laps)
EXPOSURE Up to 90 days
CONSTRUCTION Spunbound polypropylene
COATING ON BACK SIDE Slip-resistant
I
ROLL LENGTH:250'(76.2 m)
ROLL WIDTH:48" (1.23 m)
--------_ ---- —-—---_----_ ..__..----- — _ - - --- -- --- ----------
ROLL WEIGHT:23 lb. (10.4 kg)
APPROX.ROLL COVERAGE:10 squares/roll-1,000 sq.ft. (92.9 m2)
(excludes laps)
i
EXPOSURE:Up to 90 days
CONSTRUCTION:Spunbound polypropylene
COATING ON BACK SIDE:Slip-resistant
I
i
CODES � -- - ---- ---------------
FBC State of Florida Approved
MIAMI-0@R&4;6NPjT%operat IT2%*9"1%PwPwCdR6w0Ana1yze site Cooki Preferences
usage,and assist in our r dfforts.By clicking"Accept Cookies."you agree
.___to-this_use._For-rnore_informafion-please_visit our_Cookie.Notice__—_—
Accept Cookies
l,
I
r ,
I g
. ...
WeafherWa#ch® �
Mineral-Surfaced! Leak Barrier �
1
Benefits: Produ�t Details:
m Excellent protection at the eaves s Traditional mineral surfacing for use Nominal Specifi tions:
and rakes, in valleys,and around with-asphalt shingle roof systems For use wit asphalt shingles
chimneys and skylights,which guards 1.5 square roll:'
against leaks caused by wind-driven is Split-back release film peels off in ■ 150 ft7(113.94 sq.m)per roll'
rain,ice dams,backed-up gutters, layers for fast installation ■ Roll width:36°(.914 m)
and roof settling s Eligible for up to a Lifetime limited or Rol length:50'(15.24 m)
warranty when used on Lifetime 2.0 square1roll:*
a Self-seals around fasteners to help Shingle roofs and it's an eligible 200 W(18.58 sq.m)per roll'
Roll width:avoid leaks component of GAF residential h:36"(.914 m)
1
■ Roll length:66.7'(20.33 m)
® Durable fiberglass-reinforced enhanced warranties ■ UV exposure:Up to 60 days.if necessary
construction ■ Shelf life:Best if used within 1 year from
date of manufacture
'Excludeslaps
Code p
rovals:
■ Meets of exceeds the performance
In the N®rth,99 most building a®des require criteria of ASTM D1970
it
■ Miami-Dade County Product
the use of leaf( barriers at the eawes:3 Control Approved
o Protection against ice dams is in Ice dams can still occur in areas ` z State of Florida approved
. Compo�ent of a UL Listed ANSI/UL
required by most building codes'at where the average temperature is 790 Class A system when used with
the eaves where the January average above 25'F(4°C) UL ClasslA shingles'
temperature is 25°F(-4'C)or lower ■ ]CC-Es Evaluation Report(ESR-1322)
or where there is a possibility of ice
® In warmer/Southern climates,leak Chactiaaal6�0_1,,cad rs esio: aureme:asinycurare",
,
barriers provide critical protection �Lifetime refers to the length otrmrranlyccrefogepra•ided and means
forming in the eaves—i.e.,areas as long as Tie anginal individual srrer(s)ofasingk-familydelached
labeled"North"s(see map). against wind-driven rain 1 fa ideacalarecgihw,acondaima(s)lavrsthepraptly�,n ethe
1 quarrying GAF products cra installed Far ather ownersls!ruciuies.
lifetime��r?=aaeisno'.oppl•;cehtatiier•re:.uti=rogeanshingles
Meets or exceeds the following requirements of ASTM D1970 ( requires the tiseof GAF Lifetime Shingles only.Lifettme coverage on
shingiw and cccessnres f2quiras the use of arr/GAF lifetime Shingle
Property Method Requirement (M any 3 quolit7ing GAF Acc?sso:ie<_.See B f f7Gfng Sy„am l maed
YJamonlyfca COmclete coverage and restrictions.Ve get com/LRs
Thickness ) D5147 Min.
.40
orqucfi'ying��C-.AFpoducts.Far instalalions not t'gtfUe for the CA,
t
Tensile strength MD(ibf/in) D2523 Min.25 RcaringS,stemunleaV✓mronty.see the 6AF Shingle&Accessory
Tensile strength CMD Ibf/in limilad t;arxnrf
g C ) D2523 Min.
Elongation at break.modified bitumen Portion-MD and CMD 9� saurne:toterna,anac Buad ag Cade peC;and G ematierat
9 O D2523 Min. � ResidentsalCcdepRCj
Adhesion to plywood at 75°F(24°C)(Ibf/ft-width) D903 Min.12 Rate.,to'LOjfneCeitiricalion.n to gforactualassemblies
Adhesion to plywood at 40°F(4°C)•(Ibf/ft width) D903 Min.2
Thermal stability(mm) D1204 Max.3
Low temperature flexibility-20'F(29°C) D1970 Pass 3
Tear resistance MD(Ibf) D4073 Min.20
Tear resistance CMD(Ibf) D4073 Min.20 43. o
Moisture vapor permeance(U.S.Perms) E96 A Max 0.1
I i
Sealability around nail D1970 Pass 8 }
waterproof integrity after low temperature flexibility D1970 Pass
Waterproof integrity of lap seam DI970 Pass
$
To learn more about the Lifetime Roofing
System visit gafcom/Lifetime
'i