Loading...
HomeMy WebLinkAboutProject Information 9rrr j� , c.L�'l1i d0IS u v - T> -LUCRE ORKS a File Copy I ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET RECEIVED Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code-Building JAN 14 2022 i' INSTRUCTION PAGE St.Lucie County Permitting COMPLETE THE NECESSARY.SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS-NOTED BELOW: I i Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Slope Application A, B,C 1;2;3;4,567 II Prescriptive BUR-RAS 150 A, B,C 2,4,5,6,7 I Asphaltic Shingles A, B, D iZ4i5,g, Concrete or Clay Tile A, B, D, E 1,2,34,b;S7 Metal Roofs A,B, D 1,2,3;4, ,fiT fl Wood Shingles and A, B, D 1,2,40,617 Shakes ;I Other As Applicable 1,2,3,4,5;67 i I i ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings j 3. Design Calculations per Chapter 16,or if applicable,RA5127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations(Reroofing Only) i 7. Any Required Roof Testing/Calculation Documentation' Form RooflnfoFeb21 Rev Feb 18,2021 I Section A (General Information) Master Permit No. Process No. Contractors Name: Sunrise City CHDO Inc License# CM27208 JobAddress45D1 AVENUE Q Fort Pierce, FL 34947 ROOF CATEGORY Low Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles RAsphaltic Shingles Metal Panel/Shingles OWood Shingles/Shakes 0 Prescriptive BUR-RAS 150 ROOF ROOF TYPE 0-New roof 0 Repair ❑ Maintenance Fv(]Reroofing ❑Recovering ..ROOF SYSTEM INFORMATION I Low Slope Roof Area(SF) Steep Sloped Roof Area(SF) 2,336 Total (SF) 2,336 i Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and Location of parapets. � I I tit � 24 1 jl I t . I . i • j r i i \ISN n C(Low Slope Roof) Surfacing: pecific roof assembly components and identify Fastener Spacing for Anchor/Base,Sheet ttachment: cturer Zone 1':_"oc @ Lap,#Row' "op ' mponent is not used,identify as"NA") Zone 1: " oc @Lap,#Rows' �" "�Manufacturer: Zone 2:r."oc @ Lap,#RoZone 3:—" oc @Lap,#R s@. t roval No.:PNumber of Fasteners Per nsulation Board: Wind Pr sures,From RAS 128 Or Calculations: Zone 1': ZOn Zon 2: Zone 3: : Zone 1: Zone 2: Zone 3: IllustrateCompo nts Noted andDetails as Applicable: esign Pressure, om the specific product approval Woodblocking, Gutter, Edge Termination, Stripping, : Flashing, Co tinuous Cleat, Cant Strip, Base Flashing, Counterfla ing,Coping, Etc., i Deck: Indicate. can Roof Height, Parapet Height, Height of Base Type: Flashi Component Material,Material'Thickness,Fastener Typ ,Fastener Spacing or Submit Manufacturers Details that Gauge Thickness: ] C ply with RAS 111 and Chapter 16.. Slope: Anchor/Base Sheet&No.df Ply(s): I Anchor/Base Sheet Fastener/Bonding Material: i FT. Insulation Base Layer: N/A Base Insultation Size and Thickness: N/A Parapet Base Insulation Fastener/Bonding-Material: y Height N/A Top Insulation Layer: NIA N/A Top Insulation Size and Thickness: N/A SBS- Cap FT.- Top Insulation Fastener/Bonding M terial: SBS-SA Se N/A Mean Base Sheet(s)&No.of Ply(s): BS-SA Plywood Roof _ Base Sheet Fastener/Bond Height ' g Material: ' N/A 10, Ply Sheet(s)'&No.o ly(s): Ply Sheet Fasten /Bonding Material: Top Ply: S -SA i 4 Top PI astener/Bonding Material: i i 1 i j . � I T LUCIE Section D (Steep Slope Roof System) Roof system Manufacturer: Architectural Shingles Notice of Acceptance Number: FL17796 Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations): Zone 1: 47.8 Zone 2e: -47.8 Zone 2n:-76-0 Zone 2r:-76.0 Zone 3e:'81 7 Zone 3r: Deck Type;'. Plywodd Type Under.Eayment: Peel'N Stick Roof Slope: 3 : [2 Insulation: None Fire Barrier; None RidgeVenti[don?yes Fastener Type&;Spacing: 2 �/2"�.Ring Shank 4"OG I it Adhesive Type: N/A Type,' ap Sheet [NIA . Mean Rod Height $%. Roof Covering: Shingles �I Type&Size Drip 3"x 3 Aluminum Edge: I i T LUCIE, WORKSI \RequiredMomentof alculations) sed tile systems,choose either Method 1 or 2.Compare the values for Mr with the values fro Mr.Ifthe Mf values n or equal to the Mrvalues;for each area of the roof,then the tile attachment method is ceptable. Method 1'Moment Based Tile Calculations Per RAS 12T Zone 1: X: . _ M(. Product pproval M _ ._y- g (Zone 2e: x _� �M ProductApproval Mf one 2n: x$ = ,. Product'Approval Zone 2r: x� _ _)—Mg: =M,� Productpproval f one xX = _) MI =Mo- Product,Appro IMf ne 3r: x" _ ,-.�} Mgi ^M Product Appr val MfMethod 2"Simplified Tile Calculations Per Table Belnt of esistance(Mr)From Table Below Product Approval M Mr required Moment Resistance* it Mean Roof Height Roof ope 15' 20' 25' 30' 40' 2:12 34.4 . 36.5 38.2 139.7 :1 42.2 3:12 32.2, 34.4 36.0 1, 7.4 '1 39.8 4:12 30.4 32.2 33.8 135.1 37.3 5:12 28.4 30.1 31.6 132.8 j 34.9 6:12 .4 28.0 29 4 130.5 fl 32.4 7:12 24. 25.9 1 .1 128.2 l 30.0 *Must be used in conjunction with a list o Xos sed tile sy ems • For Uplift based tile systems use Method the valu s for F'with.the values for Fr If the'F'values are greater than or equal to the Fr values,for each area of thehe the ttachment method is acceptable. Methoase Tile Calculations Per RASI 12T (Zone 1: x L =x W:= )- s =Fri Product Approval F' (Zone 2e: x L =x W:= )- s r =Frze' ProductApproval F' (Zone 2n: x L =x W:= )- r =Frzn Product Approval F' (Zone 2r: x L =x W:= )- os =Frzr Product Approval F' (Zone 3e: x L =x W:= )- os r =Fr3e Product Approval F'(Zone 3r. x L =x W:= )- os r =Fr3r Product Approval F' Where to Obtain Infor ation Description Symbol l Where to find l Design Pressure Zo es 1,2e,2n,2r,3e,3r From apple ble table in RAS 127 or by an engineering analysis prepared by based on AI SCE 7 Mean Roof Height H Job Site l l Roof Slope B Job Site ( l Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravi Mg Product Approval l 1 Attachment Resistance Mf Product Approval l Required Moment Resista a Mg Calculated 1 1 Minimum Attachment sistance F' Product Approval l l Required Uplift Resis nce Fr Calculated ( l Average Tile WeigV W Product Approval l a Tile Dimensions L=length W=width Product Approval 1 'l All calculation/must be submitted to the building official at the time of permit application. i i i