Loading...
HomeMy WebLinkAboutRoofing Felt Installation Recomendations r� I i •p x(„ i File COPY WARRIORe ROOFING MANUFACTURING P.O.BOX 40185+TUSCALOOSA.AL 35M+PHONE(205)553.1 34+FAX(205)5W 755 f 193 LEROY ANDERSON ROAD+MONROE,GA 30655+PHONE(770)207-0695+FAX(770)207-0775 . qq Q4 323 DEVELOPMENT AVENUE+CHAMBERSBURG,PA 17201+PHONE(717)709.0323 i rrFF��,i FRXYAR709-0027 JA N 1 4I 2022 9f Perr"i.�€ll�rjt�r r i fiiiia Roofing Felt Installation Recommendations Be aware that roofing felt should not be walked upon prior to fastening into position. Proper safety equipment is recommended for all installations. Also,the roof decking should be clear of debris and moisture prior to installation of the roofing felt. Roofing felt should be installed from the bottom of the roof in horizontal layers to increase the water shedding ability of the felt. The initial layer of felt should be installed to cover the bottom edge of the decking,from edge to edge. Overhang is not required. i Anchor the top corner of the felt after it has been properly positioned and roll the felt out across the roof. Pay careful attention to roll the felt out smoothly, avoiding'iwrinkles as you move across the roof. The top edge of the felt should be fastened no less than every eight inches. The middle and bottom edge should also be fastened no less than every - eight inches. Fasteners should be applied no less than every eight inches along the eaves. I The next.course of felt should also be aligned with the roof edge and should overlap the previous course two inches(sometimes referred to as head lap). In the event you get to the end of a roll prior to getting to the opposite edge of the roof,-begin a new roll with a four inch overlap over the end of the prior roll(sometimes referred to as end lap). The same fastening pattern used on the middle and bottom of the initial course should be used for each subsequent course. For the top of each subsequent course,fasten intermittently to hold the top edge in place until the next course is applied. The fasteners in the bottom of the next course will hold the top of the previous course securely. Continue up the roof in this manner. Be sure to firmly fasten the top of the final course if it terminates at the top edge of the roof. Otherwise,overlap the felt over the ridge and secure then begin at the bottom of the other side of the ridge and repeat the process. In valleys,lay a vertical section of roofing felt the length of the valley prior to the installation of the horizontal runs of roofing felt. If you use more than one section of roofing felt in a valley,be certain to start at the bottom and overlap;each,subsequent length a minimum of two inches as you move up the valley jLo,nsue Pate- shedding• 5W"Cx Yl en • �VA f } �Mt i i I I In the event some wrinkles are created while fastening down a course of felt,slice the wrinkles and fasten them flat to the deck. Then seal the cuts with waterproofing cement. Installation of the primary roof covering(ex. Shingles)is recommended immediately after felt installation. i i NOTE: LOCAL BUILDING CODES MAY REQUIRE A DIFFERENT FASTENING PATTERN AND/OR SPECIFIC FASTENER TYPES THAN RECOMMENDED BY THESE INSTRUCTIONS. PLEASE CONTACT YOUR LOCAL BUILDING CODE ADMINISTRATOR FOR THE EXISTENCE OF REGIONALLY SPECIFIC FASTENING REQUIREMENTS. { i ' 1 j i I . i i I j I , • j j I r_a, yn"V.Yr.dt5�ir14 e^}� $+1 a Af'47j•'iY'h'z'1��.,t.d tila trn. '`,?;Z + t•' i,... 9z ` 3 lJ. t u`i4 � .�aoA L�t 6 r: ...` � j 1 I r 'r BCIS Home E Log In User Registration Hot Topics E Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search + C1i1t a 1111 'Product Approval %USER:Public User E .4' I P'' Product pproval Menu>Product or Application Search>eBplication List>Application Detail l FL# FL2346 R8 Application Type Revision j Code Version 2020 Application Status Approved 1 Comments d Archived I i Product Manufacturer Warrior Roofing Manufacturing Address/Phone/Email 3050 Warrior Road i Tuscaloosa,AL 35404 1 (205) 553-1734 Ext 115 1 Steven@WarriorRoof!n'g'.net i i Authorized Signature Steven Crew Steven@WarriorRoofing.net I i Technical Representative Steven Crew Address/Phone/Email 3050 Warrior Road j Tuscaloosa,AL 35404 1 (205) 553-1734 Ext1024 i Steven@WarriorRoofing.net I I Quality Assurance Representative Steven Crew SS Address/Phone/Email 3050 Warrior Road 1 Tuscaloosa,AL 35404 (205) 553-1734 Ext 1'024 I Steven@WarriorRoofing.net i Category Roofing Subcategory Underlayments I i Compliance Method Test Report 1 Testing Lab PRI Construction Materials Technologies, LLC Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/31/2024 Validated By Jesus Gonzalez, P.E. Validation Checklist-Hardcopy Received i Certificate of Independence FL2346 R8 COI PRI CMT Cert of Indeoendence.g_df I I Referenced Standard and Year(of Standard) Standard ; Year ASTM D226 j 2009 ASTM D4869 2016 Equivalence of Product Standards Certified By Approved Testing Lab FL2346 R8 Equiv FBC'2020 Standards Equivalency_pdf i { ! a ` { Product Approval Method Method 1 Option B I 1 I Date Submitted 07/02/2020 Date Validated 08/11/2020 Date Pending FBC Approval 08/12/2020 Date Approved 10/13/2020 I i Summary of Products FL# Model,Number or Name Description ! 2346.1 #15 and #30 roofing.felt ASTM D 226 Tested Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL2346 Rd II InstallationInstructions.pdf Approved for use outside HVHZ:Yes Verified Byi PRI Construction Materials Technologies, LLC Impact Resistant: N/A Test Reports Design Pressure: N/A FL2346 R8, TR 15A Test keport.pdf Other: Primary roof covering should be installed immediately FL2346 R8, TR 30A Test iteport pdf after felt. Roofing felt is not intended to be an unprotected I weathering surface. 2346.2 15w and 30w roofing felt ASTM D 4869 Tested Limits of Use Installation Instructions Approved for use in HVHZ: No FL2346 118' II Installation Instructions.pdf Approved for use outside HVHZ:Yes Verified Byt PRI Construction Materials Technologies, LLC Impact Resistant:N/A Test Reports iI Design Pressure: N/A FL2346 R8 TR 15w Test Report.pdf Other: Primary roof covering should be installed Immediately FL2346 118' TR 30w Test Report pdf after felt. Roofing felt is not intended to be an unprotected weathering surface. i d Back Nexk I Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487 11824 The State of Florida is an AA/EEO employer.Cop)_right 2007-2013 State of Florida.::Privaty Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to la public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455 F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are polblic record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: { 'GI`et11�5.+ 1`V j f' safe 1 i I I I Y l 1 a 1 i I i i u i i