Loading...
HomeMy WebLinkAboutProduct Approval Metal Roofing s ' Y I ' �:�' BCIS Home j Log In` User Registration I Hot Topics { Submit Surcharge { Stats&Facts { Publicatlons { Contact Us BCIS Site Map Unks { 'Search 1.{ Honda Jk Product Approval r USER:Public User RECEIVED Product Approval Menu>Product or Aopllcation Search>AgApplicationtlon List>Application Detail i DEC E r zo21 X i e FL# FL27499-R4 1, Application Type Revision St,LuCle County, Perm1Copy Code Version 2020 Application Status Approved I _� 1 lam VIEWED FC Comments CODE COMPLIANCE Archived f�; T YProduct Manufacturer Dynamic Metals STe L CIE COUNTY ��� I /�� Address/Phone/Email 3201 SE Dominica Terace I `/ aZ Stuart,FL 34997 (772)872-8030 juan@dynamicmetal.net I i Authorized Signature Lara Jesus juan@dynamicmetal.net I Technical Representative Address/Phone/Email i Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing � I I Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ._;a Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Scott Wolters Evaluation Report Florida License PE-62354 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 12/06/2026 Validated By Lucas A.Turner,P.E., MBA "Z3 Validation Checklist Hardcopy Received Certificate of Independence FL27499 R4 COI Dyn COI.pdf Referenced Standard and Year(of Standard) Standard Year TAS 100 1995 TAS 110 2000 TAS 125 2003 I Equivalence of Product Standards Certified By I Sections from the Code i I i Product Approval Method Method 1 Option D 1 Date Submitted 04/18/2021 I Date Validated 04/30/2021 Date Pending FBC Approval 05/03/2021 Date Approved 06/08/2021 Summary of Products j i Go to Page Page i/2 f1� F Model,Number or Name Description 2749 .1 DM Class 1000 1"Nailstrip 26 Ga. galvalume coated stei i roof panel, 16"wide,with 1" snap fit seams. Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL27499 R4 II 4991 Dwo,pdf Approved for use outside HVHZ:Yes Verified By:I Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other: Please see Eval report for Limits of Use. FL27499 R4 AE 4991 Eval.lpdf Created by Independent Third Party:Yes 27499.2 DM Class 1000 1"Nailstrip, .032"Aluminum roof panel, 16"wide,with 1"snap fit seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 4992 Dwg,Rff Approved for use outside HVHZ:Yes Verified By:IScott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 4992 Eval.pm Created by Independent Third Party:Yes I I 27499.3 DM Class 1050 1 1/2"Nailstrip .032"Aluminum Roof Panel, 19"Wide,with 1 1/2"snap fit seams. 1 Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 4993 Dwg. f Approved for use outside HVHZ:Yes Verified By: Scott Wolters,P:E. FLPE#62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 4993 Eval.Rdf Created by Independent Third Party:Yes I I 27499.4 DM Class 1050 1 1/2"Nailstrip 24 Ga. Galvalume coated steel roof panel, 19"wide,with 1 1/2"snap fit seams Limits of Use Installationl Instructions 1 Approved for use in HVHZ:Yes FL27499 R4 II 4994 Dwg_p�d Approved for use outside HVHZ:Yes Verified By: Scott Wolters,P.E. FLPE#62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 4994 Eval.pd Created by Independent Third Party:Yes I I 27499.5 DM Class 1150 1"Mechanical Seam .032"Aluminum roof panel,21"wide,with 1"standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R41 II 4995 Dwg_pl f Approved for use outside HVHZ:Yes Verified By: Scott Wolters FLPE#62394 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other: Please see Eval Report for Limits of Use. FL27499 R41 AE 4995 1. I Idf Created by Independent Third Party:Yes ( I 27499.6 DM Class 1150 1"Mechanical Seam .032"Aluminum roof panel,21"wide,with 1"standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:No FL27499 R4 II 4996 DWg Pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters FLPE#62394 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Installation Drawings and Eval Report for FL27499 R41 AE 4996 Eval.p, Limits of Use. Created by Independent Third Party:Yes 27499.7 DM Class 1150 1"Mechanical Seam 26 Ga. Galvalume coated steel roof panel,21"wide,with 1" standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R41 II 4997 Dwg,pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters FLPE#62394 i I I Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Please see Installation Drawings and Eval Report for FL27499 R4 AE 4997 Eval.pdf Limits of Use. Created by Independent Third Party:Yes 27499.8 DM Class 1500 1 1/2"Mechanical .032"Aluminum roof panel,20"wide,with 1 1/2"standing Seam seams. Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL27499 R4 II 4998 Dwg_6jf Approved for use outside HVHZ:Yes Verified By:l Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Eva[report for Limits of Use. FL27499 R4 AE 4998 Eval.odf Created by Independent Third Party:Yes 27499.9 DM Class 1500 1 1/2"Mechanical 16 oz. Copper roof panel,16"wide,with 1 1/2"standing Seam seams. I Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 4999 Dwg&fff Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 4999 Eval.pdf Created by Independent Third Party:Yes 27499.10 DM Class 1500 1 1/2"Mechanical 26 Ga.galvalume coated steel roof panel, 16"wide,with 1 1/2" Seam standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49910 Dwg. df Approved for use outside HVHZ:Yes Verified By:IScott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Please see Eva[report for Limits of Use. FL27499 R4 AE 49910 Eval.pdf Created by Independent Third Party:Yes 27499.11 DM Class 1500 1 1/2"Mechanical .032"Aluminum roof panel,116"wide,with 1 1/2"standing Seam seams. Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL27499 R4 II 49911 Dwg.odf Approved for use outside HVHZ:Yes Verified By:(Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 49911 Ev4pd Created by Independent Third Party:Yes i 27499.12 DM Class 1500 1 1/2"Mechanical 24 Ga.galvalume coated steel roof panel, 16"wide,with 1 1/2" Seam standing seams. Limits of Use Installation)Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49912 Dwgpdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R41 AE 49912 Eval!pdf Created by Independent Third Party:Yes 27499.13 DM Class 1500 1 1/2"Mechanical 24 Ga. galvalume coated steel roof panel,20"wide,with 1 1/2" Seam, standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 114 II 49913 Dwg pdf Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R41 AE 49913 Eval Ipdf Created by Independent Third Party:Yes i 27499.14 DM Class 1750 1 3/4"Snaplock 24 Ga. Galvalume coated steel roof panel, 18"wide,with 1 3/4"Snaplock seams,attached to metal deck. Limits of Use Installation,Instructions Approved for use in HVHZ:Yes FL27499 R41 II 49914 Dwq.pd Approved for use outside HVHZ:Yes Verified By: Scott Wolters,P.E. FLPE#62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 49914 Eval Ipdf Created by Independent Third Party:Yes 27499.15 DM Class 1750 1 3/4"Snaplock 032"Aluminum roof panel,18"wide,with 1 3/4"Snaplock seams,attached to metal deck. Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL27499 R4 II 49915 DwaI Approved for use outside HVHZ:Yes Verified By;Scott Wolters 62354 Impact Resistant:N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation lReports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 49915 Eval.pd Created by Independent Third Party:Yes i 27499.16 DM Class 1750 1 3/4"Snaplock .032"aluminum roof panel, 18"wide,with 1 3/4"Snaplock seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 4991I Dwg pdf Approved for use outside HVHZ:Yes Verified By:I Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 49916 Eval.pdf Created by Independent Third Party:Yes 27499.17 DM Class 1750 1 3/4"Snaplock 24 Ga. galva�lume coated steel roof panel, 18"wide,with 1 3/4" Snaplock seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49917 dwaI& Approved for use outside HVHZ:Yes Verified By:(Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 49917 Eval.pdf Created by Independent Third Party:Yes i 27499.18 DM Class 2000 2"Mechanical Seam .032 Aluminum roof panel, 18"wide,with 2"standing seams. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4 II 49918 Dwg df Approved for use outside HVHZ:Yes Verified By:'Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4 AE 49918 Eval.pdf Created by Independent Third Party:Yes I 27499.19 DM Class 2000 2"Mechanical Seam 24 Ga. galvalume coated steel roof panel,18"wide,with 2" standing seams. Limits of Use Installation!Instructions Approved for-use-In HVHZ:Yes FL27499 114 II 49919 Dwg,pd Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R41 AE 49919 Evalipdf Created by Independent Third Party:Yes i 27499.20 DM Class 500 5V Crimp 26 Ga.galvall me coated steel roof panel,24"wide,with 5V crimp. Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL27499 R4I II 49920 Dwg,p Approved for use outside HVHZ:Yes Verified By: Scott Wolters 62354 Impact Resistant: N/A Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports Other:Please see Eval report for Limits of Use. FL27499 R4I AE 49920 Eval.pdf Created by Independent Third Party:Yes Go to Page ' Page 1/2 1� i Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida Is an AA/EEO employer.QpyNght 2007-2013 Slate of FloNda.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with anlemall address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determind'If you are a licensee-under Chapter 455,F.S.,please dick here. Product Approval Accepts: r„ "•r ?x'„ ® eCeecY Ewa I � I WOLTERS ENGINEERING ENGINEERING,`DRAFTING,CONSULTING 15211 97th Road,N West Palm:Beach,R .33412 Ph/Fx:(561)125-1982 PRODUCT EVALUATION RECEIVED (FOR HVHZ APPROVED PRODUCT) DEC 3 0 2021 St.Lucie County PRODUCT: DM.CLASS 1000.26',GA. GALVALUME V NAILSTRIP 116"WIDE Permitting ROOF PANEL fLPM 27499.1) MANUFACTURER: DYNAMIC METALS, LLC 3201:8E ROMINICATERRACE. STUART, FL 34997 To.all concerned, The.DM Class 1000SerLs 26 Ga, Galvalumo T Nailstrip 16"'Wi e Roof Panel, manufactured by Dynamic Metals LLC, is a.non-structural oalvadumb coated Flur000n painted steel.roof panel (50 ksi min)that meets the requirements of Sections 1507A and 1518..9 of 7th Edition,(420) Florida&ildlq Code. he panel.has been I iT - tested per TAS 100,TAS 125,,and ASTM E2140 by Intertek B&C with results shown in test re G3443.40450- 44,.G3443.14-460=44,.and MI607,01-450-44,. Ithas also been tested 0erTAS�110 by PRI Znos�truttion Materials Technologies,With iresults shown in test reports VLS-004-02-01 and VLS-'005-0,2_01. Technical Documentation: 1. Drawing*"N SS1 6=HZ dated 8M.6/1.9, signed and sealed by Scott Woltorsi PE. 2. Test Reports'listed-above b Architectural -Testing sealed u Abraham, PE,and . . . � y � - , I , Inc.signed and s by.Vir by PkI Construction M8ter.ials'T'echnologies,.�i.gned'and sealed by Zachary R Piiest, PE, 3. ,Supplemental Calculations to support NSS161HZ signed and sealed by Scott cott W)Iters, PE. I have reviewed this,submittal-per the requirements.of FAC Product Approval Rule Chapier,61 G20-'8.005 1 (4). Based on the,limitations.listed below and those provided in the documents above,ove, this product meets all the requirements of the 7th Edition (2020),Florida*Building Code general .and,C,hap,ter 15 specifically, including the .HVHZ provisions. Limitations: This-panel is�.alpproved for use inside and outside of the HVHZ. :Overall Limitations-- Maximum Pahel,.Width: 6"(nominal) Fastener Spacing across panel: 16"(at N.a'llstn'p) (Panels overlap withmale/female snap fit) Min. Slope: HVHZ: 1712" 15, �L IN .5FFCIALIZIN6 IN IMPAC�P,�515fANTCU�fAINWALL5,5fOMFPON VV roW5 Option#1 Option#2 Installation { Installation Max. Design Pressure: -116 psf -176 psf Fastener Spacing: 3" From Ends, 6" Max. O.C. l 3" From Ends, 6"Max. O.C. Min Panel Fasteners: #10xl" Panclip Fasteners #10x1" Panclip Fasteners Panel Sealant: Continuous bead of Geocell 2300 Continuous bead of Geocel 2300 or 2320 at Nailstrip side of seam or 2320 lat Nailstrip side of seam at roof slopes<3"/12"only) Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note#2 below) Note: Outside of the HVHZ in areas with windspeeds< 170 mph, 1"round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Underlayment: Minimum ASTM D 226 Type II, installed and anchored per FBC Section 1507.1.1.1 (min). (or) Any underlayment with a valid FLPA or Miami-Dade NOA Note: Outside of the HVHZ in areas with windspeeds< 170 mph, 1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Minimum Substrate: Y2' (15/32"min)4-ply CDX Plywood or%"solid wood planks(S.G.= .42 min) nailed to 2x rafters spaced 24"Max.on centeir with 8d ring-shank nails spaced 6"on center. Note: The%"wood planking must be installed as a solid deck and must be nailed or fastened in a manner equal!,to the deck albove, or as specified by a Florida licensed Arch itect/Engineer i Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. 5MCI&IZIN6A IN IMPACT r,�515MW CXfAINWALl.5, %OPVP'0N1'5, &WINXW15 I. I 1 4. All panel:system perimeters, penetrations, and transitions tote flashed and sealed per the requirements-of k.,4133. p 5. Rational analysis, provided by ia Florida licensed Architeet/Frngineer. per FAS 61G20.3.005(e), may be used for project specific approval by the Local authorities having ju��sdiction. 6.Where required by the Florida Builuing Code, panels shall be permanently.labeled with the manufacturer's,name and/or logo, and the following stafement, "Dynam'ie Me ais FL#27499.1, DM Class 1000°. Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines,per approval:of 3d party QA provider,.to'the dimensions shown on DraWing NS8'1644Z. S80-6800617 -SSQ-5150216 SSQ-6810617 8SQ-6690517 SSQ-45606I1I5 'SSQ2-2310920 5VC-0490718 _5VC 036051�6. `SSQ2-2320920 Re=Roofinq The OM Class 1000 Series 26 Ga.:Galvalume 1"Nail 'trip 16"Wide,Roof Panel may be.installed over:a single layer of existing asphalt hingles, provide the existing roof meets the requirements of.Section 1:511 of the;Florida Building Go de. If you:have any questions or;need more'informatiion concerning.this approval, please contact me. :5464ata s,r., Thank you, IN ,sPrt F �E No :62354 .71 :Scott Wolters FL PE#6235V r STATE -OF .APR 15 ZO�a 5MCI&OK16 IN IMPACt M5151ANT CUFUAINW&1,6, %OpMM 5,& WINn0W5 a OK CLASS 100 1 MAILS TRIP RIP 16co .91.YQDE.. 26 GA. G;ALIO��.�I�i � �� PANEL (H1�HZ): U m y W J'}i S17 Si111�`� ' F iNood:Deck I -My P�� t• LL 1 Integral`Snap Lock 'Geocet_230&or 2320`Sealant: cam= J e n E Pancake-Head Screw LsJ �o (See`Eval Report for' Fastener Spacing) U a Q >- z ON rv: pLL ry 31-T- m. Panel Profile S -IiZ. �i, 1./1