Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Notice of Acceptance
i A0 H1,D File Copy MIAMI-DADE COUNTY .0 t PRODUCT CONTROL SECTION PRODUCT SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) I Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) 2767/2, iv-ww.miamidade.Uov/economy Mule-Hide Products Co.,Inc. REVIEW 1195 Prince Hall Drive CODE CO i ' PLIANCE Beloit,WI 53511 ST. L CBE C O O N TY SCOPE: BO0-C (1/4Z�, This NOA is being issued under the applicable rules and regulations governing he use of corI truction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade Cour y)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or,material fail to meet the requirements of the applicable building code. i This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. I DESCRIPTION: Mule-Hide Self-Adhered Roof System over Wood Decks I LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there his been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. I ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacture i or its distributors and shall be available for inspection at the job site at the request of the Building Offilcial. This NOA revises NOA#17-0824.11 and consists of pages 1 through 29. j The submitted documentation was reviewed by Hamley Pacheco,P.E. { A, I ray NOA No.: 19-0508.04 MIAMaDADE COUNTY t Imo, .w n Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 1 of 29 i i � I ROOFING ASSEMBLY APPROVAL Category Roofing Sub-Category: Modified Bitumen Materials SBS/APP/TPO Deck Type: Wood Maximum Design Pressure -112.5 psf I TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description i G2 Base Sheet 108' x 36" ASTM D 4601, Asphalt-coated fiberglass reinforced base sheet Type II Nail Base 65' 2"x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced base Type I sheet. SA Base Sheet 66' 8"x 3' 3 3/8" ASTM D 6163, Self-adhered, fiberglass reinforced, SBS modified Type I bitumen membrane with a self-adhering back face and a smooth top surface. SA Base Sheet FR 66' 8"x 3' 3-3/8" ASTM D 6163, Self-adhered,ifire-rated,fiberglass reinforced, SBS Type I modified bitumen membrane with a self-adhering back face and a smooth oth top surface. Nail Base P 65' 8"x 3' 3-3/8" ASTM D 6164, SBS modified asphalt coated polyester reinforced base Type I sheet. SA-SBS Cap Sheet 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered, fiberglass reinforced, SBS modified Type I bitumen membrane with a self-adhering back face and a granule top surface. SA-SBS Cap Sheet FR 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fire-rated,polyester reinforced, SBS Type I modified bitumen membrane with a self-adhering back face and a granule top surface. SA-SBS KoolCap® 32' 10"x 3' 3 3/R" ASTM D 6164, Self-adhered, fiberglass reinforced, SBS modified Type I bitumen membrane with a self-adhering back face and a granule top surface. SA-SBS KoolCap® 32' 10"x 3' 33/8" ASTM D 6164, Self-adhered,fire-rated,fiberglass reinforced, SBS FR Type I modified bitumen membrane with a self-adhering back face and a granule top surf ice. APP Torch S 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a bum off polyethylene back face and a smooth or sanded top surface. SA-APP Cap Sheet 32' 10"x 3' 33/8" ASTM D 6222, Self-adhered,polyester reinforced,APP modified Type I bitumen membrane with a i elf-adhering back face and a granule top surface. SA-APP Cap Sheet FR 32' 10"x 3' 33/8" ASTM D 6222, Self-adhered, fire-rated,p Iyester reinforced,APP Type I modified bitumen membrane with a self-adhering back face and a granule top surfi ce. I NOA No.: 19-0508.04 CMIAMMADEGOUNTY Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 2 of 29 II � I APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) Mule-Hide Poly ISO 1 Polyisocyanurate foam insulation Polyglass USA,Inc. Poly ISO 2 Polyisocyanurate foam insulation Polyglass USA,Inc. ACFoam-II Polyisocyanurate foam insulation Atlas Roofing Corp ACFoam-III Polyisocyanurate foam insulation Atlas Roofing Corp Structodek High Density Fiberboard Roof Wood fiber insulation board Blue Ridge Fiberboard,Inc. Insulation DensDeck,DensDeck Prime Gypsum insulation board Georgia-Pacific Gypsum LLC H-Shield Polyisocyanurate foam insulation Hunter Panels,LLC H-Shield CG Polyisocyanurate/perlite composite insulation Hunter Panels,LLC ENRGY-3 Polyisocyanurate foam insulation Johns Manville Corp. Fesco Board Expanded mineral fiber Johns Manville Corp. Multi-Max FA-3 Polyisocyanurate foam insulation Rinax Operating,,LLC. SECUROCK Gypsum-Fiber Roof Board Fiber reinforced coverboard United States Gypsum Corporation APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Dekfast DF-#12-PH3 Insulation fastener for wood,steel SFS Group USA,Inc. and concrete decks 2. Dekfast DF-#14-PH3 Insulation fastener for wood, steel Various SFS Group USA,Inc. and concrete decks 3. Dekfast DF-#15-PH3 Insulation fastener for wood,steel Various SFS Group USA,Inc. and concrete decks 4. Dekfast PLT-H-2-7/8 Galvalume hex stress plate. 2 7/8"x SFS Group USA,Inc. 3 1A 5. #14 Roofgrip Insulation and membrane fastener Various OMG,Inc. 6. Flat Bottom Metal Plate A2-SS aluminized steel plate 3" square OMG,Inc. 7. Mule-Hide HDP Fastener Insulation fastener for steel and Mule-Hide Products wood decks Co.,Inc. 8. Mule-Hide 3"Metal Insulation Round Galvalume AZ50 steel plate 3.23 round Mule-Hide Products Plate 3"round Co.,Inc. 9. #12 Standard Roofgrip Insulation fastener for wood,steel Various) OMG,Inc. and concrete decks NOA No.: 19-0508.04 MIAMFQAO;COUNYY Expiration Date: 10/11/22 Approval Date:08/08/19 Page 3 of 29 I i ' I I APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Descriution Dimensions (With Current NOA) 10. OMG 3 in.Ribbed Galvalume Galvalume stress plate. 3"round OMG,Inc. Plate(Flat) 11. OMG 3" Galvalume Steel Plate Galvalume stress plate. 3"round OMG,Inc. 12. Dekfast PLT-R-3 Galvalume stress plate. 3"round SFS Group USA,Inc. 13. Millennium One-Step A two component,low rise, H.B. Fuller Company Foamable Adhesive polyurethane foam adhesive 14. Millennium One Step Green A two component,low rise, I H.B.Fuller Company Foamable Insulation Adhesive polyurethane foam adhesive 15. Millennium PG-1 Pump Grade A two component,low rise, H.B. Fuller Company Adhesive, polyurethane foam adhesive 16. PG 100 A penetrating solution of solvent 1, 3,5,50,55 Polyglass USA,Inc. and a blend of selected asphalts used gal,tube or 17 to promote adhesion. oz. spray can 17. PG 350 A fibered rubberized adhesive i 1,3, 5, 50,55 Polyglass USA, Inc. designed for use with modified gal.or tube bitumen membranes. 18. PG 400 A thick,fibered,rubberized flashing) 1, 3, 5,50,55 Polyglass USA,Inc. cement for use in dry or damp gal. or tube conditions. 19. PG 425 A thick,fibered,rubberized flashing 1,3, 5,50,55 Polyglass USA,Inc. cement for use in dry or damp gal. or tube conditions. 20. PG 450 A thick, fibered,iubberized flashing' 1, 3, 5,50,55 Polyglass USA,Inc. cement. gal.or tube 21. PG 500 A thick,fibered,rubberized flashing 1,3, 5,50,55 Polyglass USA, Inc. cement for use with modified gal. or tube bitumen membranes. 22. POLYPLUS 35 A fibered rubberized adhesive 1, 3, 5,50,55 Polyglass USA, Inc. designed for use with modified gal. or tube bitumen membranes. 23. POLYPLUS 45 A thick,fibered,rubberized flashing 1,3, 5,50,55 Polyglass USA,Inc. cement. gal. or tube 24. POLYPLUS 50 A thick,fibered,rubberized flashing 1,3, 5,50,�55 Polyglass USA, Inc. cement for use with modified gal. or tube bitumen membranes. 25. XtraFlex 10 A penetrating solution of solvent 1, 3,5,50,55 Polyglass USA,Inc. and a blend of selected asphalts used gal,tube or 17 to promote adhesion. oz. spray can NOA No.: 19-0508.04 rauartaoaoeCOUNTY Expiration Date: 10/11/22 Approval Date:08/08/19 Page 4 of 29 I APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 26. XtraFlex 35 A fibered rubberized adhesive 1,3,5,50,55 Polyglass USA,Inc. designed for use with modified gal.or tube bitumen membranes. 27. XtraFlex 50 Premium Modified A thick,fibered,rubberized flashing 1, 3, 5, 50, 55 Polyglass USA,Inc. Wet/Dry Cement cement for use with modified gal.or tube bitumen membranes. 28. WB-3000 A low-VOC,water-based acrylic 5 gallon pail Polyglass USA,Inc. primer to enhance adhesion of self- adhered membranes. i i i i i NOA No.: 19-0508.04 MAW DBcoin Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 5 of 29 I I i APPROVED SURFACING: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Number Product Product Application Specification Manufacturer Name Description Rate 1. Gravel To be installed in a flood coat 400 lbs/sq N/A Generic of approved asphalt at 60 lbs/sq 2. Slag To be installed in a flood coat 300 lbs/sq N/A Generic of approved asphalt at 60 lbs/sq 3. KM Acryl 15 A premium white or tinted 1-1'/z gal/sq ASTM D6083 Polyglass USA, elastomeric acrylic based roof Inc. coating(water-based). A polyester fabric may be used for reinforcement with this coating. 4. KM Acryl 15 QS A premium white or tinted 1-1'/2 galUsq ASTM D6083 Polyglass USA, quick setting, elastomeric Inc. acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 5. KM Acry125 A premium white or tinted 1-1'h gal/sq ASTM D6083 Polyglass USA, elastomeric acrylic based roof Inc. coating(water-based). A polyester fabric may be used for reinforcement with this coating. 6. KM Acryl 25 QS A premium white or tinted 1-1'/Z gaUsq ASTM D6083 Polyglass USA, quick setting, elastomeric Inc. acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 7. KM-PS#220 A single component, solvent, 1.25 gal/sq ASTM D6694 Polyglass USA, white or tinted, silicone Inc. coating. 8. KM-PS#250 A premium grade high solids, 1.25 gaUsq ASTM D6694 Polyglass USA, white or tinted,single Inc. component,moisture cure, fluid applied silicone coating 9. PG 300 An asphalt cutback fibered roof 1'/2-2 gal/sq ASTM D4479 Polyglass USA, coating. May be applied by Inc. brush or spray equipment to rejuvenate aged BUR MIaMaAoe covrm NOA No.: 19-0508.04 - Expiration Date: 10/11/22 Approval Date:08/08/19 Page 6 of 29 I i APPROVED SURFACING: TABLE 4 Chosen components must be applied according to manufacturer's application instructions. Number Product Product Anplication Specification Manufacturer Name Description Rate 10. PG 600 Non-fibered aluminum roof %-1 gal/isq ASTM D2824 Polyglass USA, coating. Type I Inc. 11. PG 650 Fibered aluminum roof coating. 1%z-2 ga]/sq ASTM D2824 Polyglass USA, Type III Inc. I 12. PG 700 A premium white or tinted 1-1'/2 gaUsq ASTM D6083 Polyglass USA, elastomeric acrylic based roof Inc. coating(water-based). A polyester fabric may be used for reinforcement with this coating. 13. PG 700 S A premium white or tinted 1-1'/a gal s ASTM D6083 Polyglass USA Q p g q Yg quick setting, elastomeric Inc. acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 14. PG 800 An asphalt based,non-fibered 3 gal/sq in two ASTM D1227 Polyglass USA, clay emulsion coats Inc. I 15. PolyBrite 70 A premium white or tinted 1-1%2 gal/sq ASTM D6083 Polyglass USA, elastomeric acrylic based roof Inc. coating(water-based). A polyester fabric may be used for reinforcement with this coating. 16. PolyBrite 70 QS A premium white or tinted 1-1%z gal/sq ASTD D6083 Polyglass USA, quick setting, elastomeric Inc. acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 17. PolyBrite 90 A premium grade high solids,. 1.25 gaUsq ASTM D6694 Polyglass USA, white or tinted,single j Inc. component,moisture cure, fluid applied silicone coating 18. PolyBrite 95 A single component,white or 1.25 gal/sq ASTM D6694 Polyglass USA, tinted, solvent,moisture cure Inc. silicone coating. 19. POLYPLUS 60 Non-fibered aluminum roof %2-1 gal/sq ASTM D2824 Polyglass USA, coating. Type I Inc. MiAMMAOE COUNTY NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date:08/08/19 Page 7 of 29 APPROVED SURFACING: TABLE 4 Chosen components must be applied according to manufacturer's applicatioin instructions. Number Product Product Application Specification Manufacturer Name Description Rate 1 20. POLYPLUS 65 Fibered aluminum roof coating. 1'/2-2 gal/sq ASTM D2824 Polyglass USA, Type III Inc. 21. XtraFlex 60 Aluminum Non-fibered aluminum roof '/24 gal/sq ASTM D2824 Polyglass USA, Roof Coating coating. Type I Inc. 22. XtraFlex 65 Aluminum Fibered aluminum roof coating. 1%-2 gal/sq ASTM D2824 Polyglass USA, Roof Coating Fibered Type III Inc. 23. XtraFlex 70 Premium A premium white or tinted 1-1%gaUsq ASTM D6083 Polyglass USA, Acrylic FR Roof elastomeric acrylic based roof Inc. Coating coating(water-based). A polyester fabric may be used for reinforcement with this coating. 24. XtraFlex 80 Emulsion An asphalt based,non-fibered 3 gal/sq in two ASTM D1227 Polyglass USA, Roof Coating clay emulsion coats Inc. 25. XtraFlex 30 An asphalt cutback fibered roof 1'/Z-2 gal/sq ASTM D4479 Polyglass USA, Bituminous Roof coating. May be applied by Inc. Coating Fibered brush or spray equipment to rejuvenate aged BUR 26. XtraFlex SRC 8000 A single component,white or 1.25 gal/sq ASTM D6694 Polyglass USA, tinted, solvent,moisture cure Inc. silicone coating. 27. XtraFlex SRC 9600 A premium grade high solids, 1.25 ga I sq ASTM D6694 Polyglass USA, white or tinted,single Inc. component,moisture cure, fluid applied silicone coating I I i NOA No.: 19-0508.04 MLAMMADQ_COUNTY Expiration Date: 10/11/22 Approval Date:08/08/19 Page 8 of 29 I EVIDENCE SUBMITTED: Test Agency Test Name/Report Report No. Date Factory Mutual Research 4470 zWW AM 08.04.94 Corporation 4450 2D5A9.AM 06.22.99 4470 3000857 01.12.00 4470 3004091 01.12.00 4470 3001334 02.15.00 4470 3014692 08.05.03 4450 3014751 08.27.03 4450 3019317 06.30.04 4470 i 3024311 11.01.06 4470 3012321 07.29.07 4470 � 3036182 07.31.09 4470 RR202591 10.22.15 Trinity ERD TAS 114 11752.09.99-1 02.08.00 TAS 114 11751.05.03 05.30.03 TAS 117(B)-ASTM D903 020841.06.04 06.02.04 TAS 114 62762.03.05 03.30.05 TAS 114 02764.09.05 09.09.05 TAS 114 P1739.01.07 01.23.07 TAS 114 1`1734.07.06-R1 02.27.07 TAS 117(B)-ASTM D6862 C8500SC.11.07 11.30.07 TAS 114&FM 4470 P7860SC.11.07 11.30.07 TAS 114(D)—ASTM D 1876 P 10070.10.08- 10.09.08 TAS 114(H) P1 ,13760.09.09 09.10.09 FM 4470&TAS 114 P33970.03.11 03.15.11 ASTM D6163/ASTM D 4601 P33960.03.11 03.15.11 ASTM D6163 P37590.03.13-2-R1 02.05.13 ASTM D6164 P37590.03.13-3A 03.06.13 TAS 114 P1738.02.07-R2 04.29.13 TAS 114&TAS 117(B) 11757.04.01-1-R1 04.30.13 ASTM D6509 P37590.03.13-1-R1 06.26.13 ASTM D6222 P37590.03.13-5-R1 07.01.13 ASTM D6164 P317590.07.13-1 07.02.13 TAS 114&FM 4474 P41630.08.13 08.06.13 ASTM D4601 /TAS 117 P45940.09.13 09.04.13 ASTM D6222 P37590.09.13 09.12.13 ASTM D4601 /TAS 117 P45970.05.14. 05.12.14 ASTM D6162 SC5170.05.15 05.08.15 ASTM D6162 SC5170.12.15-1 12.29.15 TAS 114&FM 4474 PLYG-SC8905.05.16-1 05.17.16 TAS 114&TAS 117(B) 11757.12.00-1-R2 04.05.17 PRI Construction Materials ASTM D6222 PUSA-061-02-02 01.28.08 Technologies ASTM D6163 PUSA-064-02-02 02.27.08 ASTM D6222 PUSA-062-02-02 12.04.08 ASTM D6694 PUSA-134-02-01 05.16.14 ASTM D6694 PUSA-135-02-01 05.16.14 TAS 117(B) PUSA-202-02-01 05.08.17 FM 4470&TAS 114 PUSA-202-02-02 05.23.17 NOA No.: 19-0508.04 MtAMMAD1 COUNTY Expiration Date: 10/11/22 Approval Date:08/08/19 Page 9 of 29 I • I APPROVED ASSEMBLIES: Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank,fastened at 24" spans with#8 wood screws at 6"o.c.. System Type A(1): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently adhered to insulation. i All General and System Limitations apply. Anchor Sheet: One ply of Nail Base,APP Torch S* or G2 Base Sheet,fastened to the deck as described below: with OMG fasteners and Flat Bottom Metal Plates. i Fastening#1: Attach base sheet using 11 ga. annular ring shank and 1-5/8"diameter tin caps spaced 8"o.c.in a 4"lap and 8"o.c. in three equally spaced staggered rows in the center of the sheet. Fastening#2: Attach base sheet using OMG#14 Roofgrip fasteners and Flat Bottom Metal Plates,Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 plates or Mule-Hide HDP f Fasteners with Mule-Hide 3"Metal Insulation Plates,spaced 12"o.c.in a 4"lap and 12"o.c. in two equally spaced staggered rows in the center of the sheet. One or more of the following I Base Insulation Laver(Optional) Insulation Fasteners Fastener Table 3 Density/ft2 Poly ISO 2,Mule-Hide Poly ISO 1,ACFoam-H,ACFoam-III,H-Shield,M lti-Max FA-3,ENRGY-3 Minimum 1.5"thick N/A N/A I I Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hoot asphalt within the EVT range and at a rate of 2040 lbs/100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Top Insulation Laver Insulation Fasteners Fastener Table 3 I Density/ftz DensDeck,DensDeck Prime,SECUROCK Gypsum-Fiber Roof Board Minimum'/a"thick N/A i N/A Note: Apply to layer of insulation in a full mopping of an approved mopping asphalt within the EVT range and PP Y P Y z PP g Y PP PA g P � g at a rate of 20-40 lbs/100 ft . Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as Base Layer only shall be used only as base layers witli a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. i Primer: Apply WB-3000 at 1 gal.per 300 sq. ft. (Optional) Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered. i NOA No.: 19-0508.04 MtAMtDAb;CCU Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 10 of 29 I I I I i ' I Ply Sheet: One or more plies of SA Base Sheet,SA Base Sheet FR,self-adhered. (Optional) Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR,SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, self-adhered. Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or (Optional) required fire classification. Maximum Design Pressure: -52.5 psf; (See general limitation 47.) I i i I i I NOA No.: 19-0508.04 MIAMMADECOUNTYExpiration Date: 10/11/22 Approval Date: 08/08/19 Page 11 of 29 . I I Membrane Type: SBS/APP I Deck Type 1I: Wood,Insulated I Deck Description: "/32" or greater plywood or wood plank, fastened at 24"spans with#8 wood screws at 6"o.c. System Type A(2): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently adhered to insulation. I All General and System Limitations apply. I Anchor Sheet: One ply of Nail Base,Nail Base P,APP Torch S,G2 Base Sheet,fastened to the deck as described below: I Fastening: Attach base sheet using OMG#14 Roofgrip fasteners and Flat Bottom Metal Plates spaced 12" o.c. in a 4"lap and 12"o.c. in two equally spaced staggered rows in the center of the sheet. One or more of the following I Base Insulation Laver(Optional) Insulation Fasteners Fastener Table 3 Density/ft' Poly ISO 2,Mule-Hide Poly ISO 1,ACFoam-I1,ACFoam-III,H-Shield,Multi-Max FA-3,ENRGY-3 Minimum 1"thick N/A N/A Top Insulation Laver Insulation Fasteners Fastener Table 3 Density/ftz DensDeck,DensDeck Prime,SECUROCK Gypsum-Fiber Roof Board Minimum '/"thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved lot asphalt within the EVT range and at a rate of 20-40 lbs/100 ft'. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. I Primer: Apply WB-3000 at 1 gal.per 300 sq. ft. (Optional) Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered. I Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. (Optional) Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap©or SA-SBS KoolCap®I,FR, self-adhered. i I Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or (Optional) required fire classification. Maximum Design Pressure: -60 psf; (See general limitation#7.) . Mt�1MkQADE COUNTY NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date:08/08/19 Page 12 of 29 � I Membrane Type: SBS/APP Deck Type 1I: Wood,Insulated I Deck Description: "/32" or greater plywood or wood plank,fastened at 24";spans with 8;d common nails at 4"o.c. or#8 wood screws at 6"o.c. I System Type A(3): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently adhered to insulation. All General and System Limitations apply. Anchor Sheet: One ply of G2 Base Sheet fastened to the deck as described below: Fastening: Attach base sheet using 11 ga. Annular ring shank and 1-5/8"diameter tin caps spaced 8"o.c. in a 4"lap and 8"o.c. in three equally spaced staggered rows in the center of the sheet. One of more of the following: � I Base Insulation Laver(Optional) Insullation Fasteners Fastener Table 3 Density/ft2 Poly ISO 2,Mule-Hide Poly ISO 1,ACFoam-II,ACFoam-HI,H-Shield,Multi-Max FA 3,ENRGY-3 Minimum 1"thick N/A N/A I Note:All insulation shall be adhered to the anchor sheet in full mopping ofI approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 W. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with aisecond layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. I Top Insulation Laver Insulation Fasteners Fastener Table 3 i Density/ft2 Dens Deck,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board Minimum'/"thick N/A N/A Note:Apply top layer of insulation in a full mopping of any approved mopping asphalt within the EVT range and at a rate of 20-40 lbs/100 ft . Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as Base Layer only shall be used only as base layers with a second layer of approved top layer final insulation installed as the membrane substrate. Composite insulation panels mi y be used as a top layer placed with the polyisocyanurate side facing down. Primer: Apply WB-3000 at 1 gal.per 300 sq. ft. (Optional) j Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR,self-adhered. j Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR,self-adhered. (Optional) Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, self-adhered. Surfacing: Install one of the approved surfacing products listed in Table 4 to obltain desired coating or (Optional) required fire classification. Maximum Design Pressure: -52.5 psf, (See general limitation V.) I NOA No.: 19-0508.04 ijaj MtAMFp1f6E COUAITY Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 13 of 29 I I � i Membrane Type: SBS/APP Deck Type 1I: Wood,Insulated Deck Description: 19/32" or greater plywood or wood plank fastened at 24",spans with#8 wood screws at 6"o.c. System Type A(4): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently adhered to insulation. All General and System Limitations apply. I ' Anchor Sheet: One ply of Nail Base or Nail Base P,fastened as below: i Fastening: 12 ga.Annular ring shank nails and 1-5/8"tin-caps attached 6"o.c. in 4"lap and 6"o.c.in four equally spaced staggered rows. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' ACFoam-II,Poly ISO 2,ACFoam-III,H-Shield,Mule-Hide Poly ISO 1,H-Shield CG,Multi-Max FA-3,ENRGY 3 Minimum 1"thick N/A N/A Note: All insulation shall be adhered to the anchor sheet with Millennium One-Step Foamable Adhesive, Millennium One Step Green Foamable Insulation Adhesive or Millennium PG-1 Pump Grade Adhesive applied over rows of tin-caps in continuous rows 7"o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Col mposite insulation panels may be used as a top layer placed with the polyisocyanurate.side facing down. Primer: Apply WB-3000 at 1 gal.per 300 sq.ft. (Optional) Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR,self-adhered. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR,self-adhered. (Optional) Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR; SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, self-adhered. Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or (Optional) required fire classification. i Maximum Design Pressure: -60 psf; (See general limitation#7.) i i i i i MtAMFDADE C NOA No.: 19-0508.04 OL/NTY ;, Expiration Date: 10/11/22 Approval Date:08/08/19 Page 14 of 29 i I I Membrane Type: SBS/APP Deck Type 1I: Wood,Insulated I Deck Description: Min. 19/32"plywood(15/32"for re-roof)or wood plank,fastened at 24' spans with 8d common nails at 6"o.c. System Type C(1): All layers of insulation are mechanically attached to roof deck.Membranes subsequently adhered to insulation. All General and System Limitations apply. One or more of the following Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ftz Any approved Polyisocyanurate listed in Table 2 i Minimum 1.0"thick N/A i N/A Note:All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Top Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 SECUROCK Gypsum-Fiber Roof Board Minimum V4"thick 2 with I or 12; 5 with 6, 10 1:2 W Or 11; 7 with 8 DensDeck Prime Minimum'/4"thick 2 with 4; 5 with 6 or 11; 7 1:2 ftz with 8 Note.All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation panels listed are minimum size n dimensions; s and d ensions• if larger panels are used the number of fasteners shall be P � g increased maintaining the same fastener density. Please refer to Roofing Applicatiin Standard RAS 117 for insulation attachment. Primer: Apply WB-3000 at 1 gal.per 300 sq. ft. � I (Optional) Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR,self-adhered. (Optional) Membrane: One ply of SA-SBS Cap Sheet FR, SA-APP Cap SheetlFR or SA-SBS KoolCap®FR,self- adhered. Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or (Optional) required fire classification. i Maximum Design Pressure: -45 psf; (See General limitation V.) � I _ I i MIAMFpAOE COVAfrY NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date:08/08/19 Page 15 of 29 i j Membrane Type: SBS/APP Deck Type 1I: Wood,Insulated I Deck Description: "/32" or greater plywood or wood plank,fastened at 24"spans with 8d common nails or wood screws at 4"o.c. System Type C(2): All layers of insulation are mechanically attached to rol f deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. One or more of the following i Base Insulation Laver Ins lation Fastelners Fastener Table 3 Density/ft2 Any approved Polyisocyanurate listed in Table 2 Minimum 1.5"thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. _Top Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 Structodek High Density Fiberboard Roof Insulation Minimum'/Z"thick 2 with 4 I 1:1.33 ftz I I DensDeck Minimum'/4"thick 2 with 4 1:1.33 ff Note:All layers of insulation shall be mechanically attached using the fastener density 1 Isted above.The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Apply WB-3000 at 1 gal.per 300 sq.ft. to DensDeck prior to application of self-adhered base (Optional) sheets. Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. (Optional) I . Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FRI, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, self-adhel ed. Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or (Optional) required fire classification. i I Maximum Design Pressure: -67.5 psf, (See General limitation#7.) i i I i NOA No.: 19-0508.04 MIAMFDA,D'COUNTYExpiration Date: 10/11/22 4tll� Approval Date:08/08/19 I Page 16 of 29 I i I Membrane Type: SBS/APP i Deck Type 1I: Wood,Insulated Deck Description: "/32" or greater plywood or wood plank,fastened at 24"spans with 6d common nails at 4"o.c. System Type C(3): All layers of insulation are mechanically attached to roof deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. One or more layers of the following: Base Insulation Laver Insulation Fasteners Fastener Table 3 Densitv/ft2 Any approved Polyisocyanurate listed in Table 2 Minimum 1.5"thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Top Insulation La er Insulation Fasteners Fastener v Table 3 Density/ft' Structodek High Density Fiberboard Roof Insulation I Minimum'/"thick 2 with 4 1:1.33 ft' DensDeck Minimum%"thick 2 with 4 1:1.33 ft2 Note:All layers of insulation shall be mechanicallyattached usingthe fastener density listed above.The insulation tY I panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Apply WB-3000 at 1 gal.per 300 sq.ft.to DensDeck prior to application of self-adhered base (Optional) sheets. I Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered. I Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR,self-adhered. (Optional) Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP CaIp Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap@ or SA-SBS KoolCap®�R, self-adhered. Surfacing: Install one of the approved surfacing products listed in'Table 4 to obtain desired coating or (Optional) required fire classification. Maximum"Design Pressure: -67.5 psf; (See General limitation#7.) i NOA No.: 19-0508.04 CMIAMMADECOUNTY r, I Expiration Date: 10/11/22 Approval Date:08/08/19 Page 17 of 29 " I Membrane Type: SBS/APP Deck Type II: Wood,Insulated Deck Description: 19/32" or greater plywood or wood plank,fastened at 24 spans with wood screws at 6"o.c. System Type C(4): All layers of insulation are mechanically attached to roof deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more of the following: Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 ENRGY 3,H-Shield,Mule-Hide Poly ISO 1,ACFoam-II,Poly ISO 2 Minimum 1.51'thick 2 with 4; 7 with 8 1:1.33 ft2 Note:All layers of insulation shall be mechanically attached using the fastener density listed above.The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Apply WB-3000 at 1 gal.per 300 sq. ft. (Optional) Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR,self-adhered. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR,self-adhered. (Optional) Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, self-adhered. Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or (Optional) required fire classification. Maximum Design Pressure: -82.5 psf; (See General limitation#7.) NOA No.: 19-0508.04 MlAMMADE COUNTY Ex iration Date: 10/ 2 P 1 2 Approval Date:08/08/19 Page 18 of 29 I � ' I Membrane Type: SBS/APP i I Deck Type 1I: Wood,Insulated Deck Description: 19/32" or greater plywood or wood plank,fastened at 24,'spans with#8 wood screws at 6"o.c. System Type D(1): All insulation is loosed laid with preliminary attachment to deck. Base sheet is subsequently mechanically fastened through insulation to the roof deck. Membranes subsequently adhered. All General and System Limitations apply. One or more layers of the following: Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/fe Any approved Polyisocyanurate listed in Table 2 Minimum 1"thick N/A N/A Top Insulation Laver(Optional) Insulation Fasteners Fastener Table 3 Density/ft' Fesco Board Minimum'/"thick N/A I N/A Structodek High Density Fiberboard Roof Insulation Minimum%11 thick N/A N/A DensDeck,DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board Minimum 1/"thick N/A N/A Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. Base Sheet: One ply of Nail Base or Nail Base P,fastened to the deck as described below: Fastening: Attach base sheet using OMG#14 Roofgrip fasteners and Flat Bottom Metal Plates,Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 plates,or Mule-Hide HDP�asteners with Mule-Hide 3"Metal Insulation Plates,spaced 12"o.c.in a 4"lap and 12"o.c. in two equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FI2, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, self-adhered. Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or (Optional) required fire classification. Maximum Design Pressure: -52.5 psf; (See General limitation#7.) I I I , NOA No.: 19-0508.04 MIAMFDAU;Courary Expiration Date: 10/11/22 Approval Date:08/08/19 Page 19 of 29 i I j Membrane Type: SBS/APP Deck Type 1I: Wood,Insulated I Deck Description: 19/32" or greater plywood or wood plank,fastened at 241?spans with 48 wood screws at 6"o.c. System Type D(2): All insulation is loosed laid with preliminary attachment to deck. Base sheet is subsequently mechanically fastened through insulation to the roof deck. Membranes subsequently adhered. All General and System Limitations apply. One or more layers of the following: Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 Any approved Polyisocyanurate listed in Table 2 Minimum 1"thick N/A N/A Top Insulation Laver(Optional) Insulation Fasteners Fastener Table 3 Density/ft' Fesco Board Minimum 3/4"thick N/A ! N/A i Structodek High Density Fiberboard Roof Insulation Minimum'/2"thick N/A N/A DensDeck,DensDeck Prime,SECUROCK Gypsum-Fiber Roof Board Minimum'/4"thick N/A N/A Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. Base Sheet: One ply of Nail Base or Nail Base P,fastened to the deck as described below: Fastening: Attach base sheet using OMG#14 Roofgrip fasteners and Flat Bottom Metal Plates spaced 12" o.c. in a 4"lap and 12"o.c. in two equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, , self-ad ered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR; SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCapO or SA-SBS KoolCap©FR, self-adhered. Surfacing: Install one of the approved surfacing products listed in,Table 4 to obtain desired coating or (Optional) required fire classification. Maximum Design j Pressure: -60 psf; (See General limitation#7.) I I j I NOA 19- 508.04 MIAMMADE iY Expiration Date: 10/11/22 j I Approval Date: 08/08/19 j Page 20 of 29 I i I i Membrane Type: SBS/APP Deck Type 1: Wood,Non-Insulated Deck Description: 19/32" or greater plywood or wood plank,fastened at 24 spans with 8'd common nails at 4"o.c. or#8 wood screws at 6"o.c. System Type E(1): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered. All General and System Limitations apply. Base Sheet: One ply of Nail Base or Nail Base P,fastened to the deck as described below: Fastening: Attach base sheet using 11 ga. annular ring shank nails and 1-5/8"diameter tin caps spaced 8" o.c. in a 4"lap and 8"o.c. in three equally spaced staggered rows in the center of the sheet. I Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR,self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR; SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap®or SA-SBS KoolCap@ FR,self-adhered. Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or (Optional) required fire classification. Maximum Design Pressure: -52.5 psf; (See General limitation#7.). i ® NOA No.: 19-0508.04 MFDAd;=ouury Expiration Date: 10/11/22 Approval Date:08/08/19 Page 21 of 29 Membrane Type: SBS/APP Deck Type 1: Wood,Non-Insulated Deck Description: 19/32" or greater plywood or wood plank,fastened at 24"spans with 8d ring shank nails at 6"o.c. at edges and intermediate supports. System Type E(2): Base sheet is mechanically attached to roof deck.Membranes subsequently adhered. All General and System Limitations apply. Base Sheet: One ply of Nail Base,fastened to the deck as described below: Fastening: Attach base sheet using 11 ga. annular grooved shank and 1"diameter caps spaced 6"o.c.in a 3"la and 6"o.c. in four equally spaced staggered center rows. P q Y P gg Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap,Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, self;-adhered. I Surfacing: Install one of the approved surfacing products listed in able 4 to obtain desired coating or (Optional) required fire classification. Maximum Design Pressure: -52.5 psf; (See General Limitation#7) i NOA No.: 19-0508.04 MdAMI•DADE COUNTY � Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 22 of 29 I Membrane Type: SBS/APP Deck Type 1: Wood,Non-Insulated Deck Description: 19/32" or greater plywood or wood plank,fastened at 24"spans with 8d common nails at 4"o.c. or#8 wood screws at 6"o.c System Type E(3): Base sheet is mechanically attached to roof deck.Membranes subsequently adhered. All General and System Limitations apply. Base Sheet: One ply of Nail Base or Nail Base P,fastened to the deck as described below: Fastening: Attach base sheet using OMG#14 Roofgrip fasteners and Flat Bottom Metal Plates spaced 12" o.c. in a 4"lap and 12"o.c.in two equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of SA Base Sheet, SA Base Sheet FR,i self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, sel -adhered. Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or (Optional) required fire classification. Maximum Design Pressure: -52.5 psf; (See General Limitation#7) I NOA No.: 19-0508.04 MAD;°CNTY 0� I Expiration Date: 10/11/22 lk Approval Date: 08/08/19 Page 23 of 29 Membrane Type: SBS/APP Deck Type 1: Wood,Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24"spans with 8d common nails at 4"o.c. or#8 wood screws at 6"o.c. System Type E(4): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered. All General and System Limitations apply. Base Sheet: One ply of Nail Base or Nail Base P,fastened to the deck as described below: Fastening: Attach base sheet using 11 ga. annular ring shank nails and 1-5/8"diameter tin caps spaced 8" o.c. in a 4"lap and 8"o.c.in three equally spaced staggered rows in the center of the sheet. i Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet P self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet,SA-APP Cap Sheet FR, SA-SBS KoolCapO or SA-SBS KoolCapO FR,self-adhered. Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or (Optional) required fire classification. Maximum Design Pressure: -52.5 psf; (See General Limitation#7) NOA No.: 19-0508.04 CMIAMMADECOUNTY ,, Expiration Date: 10/11/22 Approval Date:08/08/19 Page 24 of 29 Membrane SBS/APP Type: Deck Type 1: Wood,Non-Insulated Deck Description: i9/32' or greater plywood or wood plank,fastened at 24"spans with#i8 wood screws at 6"o.c. System Type E(5): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered. All General and System Limitations apply. Base Sheet: One ply of Nail Base,fastened to the deck as described below: Fastening: Attach base sheet using OMG#14 Roofgrip fasteners and Flat Bottom Metal Plates, Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8, or Mule-Hide HDP Fasteners with Mule-Hide 3" Metal Insulation Plates, spaced 12"o.c. in a 4"lap and 12"o.c. in t io equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR,self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, self-adhered. Surfacing: install one of the approved surfacing products listed in Table 4 to obtain desired coating or (Optional) required fire classification. Maximum Design Pressure: -60 psf; (See General limitation V.). I I M�nr�ac2aoe COUNTY No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 25 of 29 I � Membrane Type: SBS/APP Deck Type 1: Wood,Non-Insulated Deck Description: 19/32" or greater plywood or wood plank,fastened to supports spaced 24"o.c. and to blocking members spaced 48"o.c.with TruFast TP#10x2-7/8"screws spaced 6"O.C. System Type E(6): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered. All General and System Limitations apply. Base Sheet: One ply of Nail Base or Nail Base P,fastened to the deck as described below: Fastening: Attach base sheet using 12 ga. annular ring shank nails and 1-5/8"diameter tin caps spaced 4" o.c. in a 4"lap and 4"o.c. in four equally spaced staggered rows in the center of the sheet. i Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR,self-adhered. Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or (Optional) required fire classification. Maximum Design Pressure: -97.5 psf; (See General Limitation#7) NOA No.: 19-0508.04 MIAMMADE COUNTY Expiration Date: 10/11/22 Approval Date:08/08/19 Page 26 of 29 I Membrane Type: SBS/APP Deck Type 1: Wood,Non-Insulated ti Deck Description: 19/32" or greater plywood or wood plank,fastened to supports spaced J4"o.c.and to blocking members spaced 48"o.c.with#100"wood screws spaced 6"o.c. System Type E(7): Base sheet is mechanically attached to roof deck. Membranes subsegi ently adhered. All General and System Limitations apply. I I Base Sheet: One ply of Nail Base or Nail Base P,fastened to the deck as described below: Fastening: Attach base sheet using 12 ga.ring shank nails and tin caps spaced 4'o.c. in a 4"lap and 4"o.c. in four equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR,self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR,�A-APP Cap Sheet,SA-APP Cap Sheet FR,SA-SBS KoolCap®or SA-SBS KoolCap®FR,self-adhered. Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or (Optional) required fire classification. Maximum Design -97.5 psf; With SA Base Sheet or SA Base Sheet FR(See General limitation#7.) Pressure: -112.5 psf;With all other base sheet options(See General limitation#7.) I I I' I I I I I i NOA No.: 19-0508.04 MwMaanDecovHry Expiration Date: 10/11/22 Approval Date:08/08/19 i Page 27 of 29 I I i Membrane Type: SBS/APP Deck Type 1: Wood,Non-Insulated Deck Description: 19/32" or greater plywood or wood plank,fastened to supports spaced 24"o.c. with#80"wood screws spaced 6"o.c. System Type E(8): Base sheet is mechanically attached to roof deck.Membranes subsequently adhered. All General and System Limitations apply. Base Sheet: One ply of Nail Base or Nail Base P,fastened to the deck as described below: Fastening: Attach base sheet using 12 ga. annular ring shanked nails and 1-5/8"tin-caps 6"o.c. in 4"lap and 6"o.c. in four equally spaced staggered rows. Tin-caps are primed with PG 100 or XtraFlex 10. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR,'§A-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap®or SA-SBS KoolCap®FR, self-adhered. Surfacing: Install one of the approved surfacing products listed in Table 4 to obtain desired coating or (Optional) required fire classification. Maximum Design -97.5 psf; With SA Base Sheet or SA Base Sheet FR(Sel e General limitation#7.) Pressure: -112.5 psf;With all other base sheet options(See General limitation#7.) i I I NOA No.: 19-0508.04 MAMMAD'.CoT Expiration Date: 10/11/22 it a Approval Date: 08/08/19 Page 28 of 29 4 i i WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq.,or mechanically attached using the Ifastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt,panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped.If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles,24" o.c.;or strip mopped 8"ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12'in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of-45'psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force!(F')value of 275 lbf.,as tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested,are below 275 lbf.insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value fisted within alspecifrc system. Should the fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing,prepared, signed and sealed by a Florida registered Professional Engineer,Registered Architect,or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105_and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional. Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. j 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field, perimeters,and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters,extended corners and corners). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. i END OF THIS ACCEPTANCE AMA®u NOA No.: 19-0508.04 Expiration Date: 10/11/22/11/22 Approval Date: 08/08/19 Page 29 of 29 I