HomeMy WebLinkAboutProject Information I
! r
DH CALCULATOR
STEP 1 STEP 2
POOL SPECIFICATIONS SELECT EQUIPMENT TOH CALCULATION
STEP 3 OF 3:TDH CALCULATION
i
Pao)Specifications
i
Pool Volume(gallons): 19443.00 gallons Suction Lift: 1.50 ft
Turn Over(hours): 6.00 hours
Filtration Flow Rate. 54.01 GPM Maximum 1 Rate 76 22 GPM
i
Selected Components k
K Ir,
SELECTION QUANTITY t MAXIMUM PIPE VELOCITY(FT/SEC) SUCTION OUTLET 8
[CONSULT YOUR LOCALCOCE] DISCHARGE S
ICHLOR 30
1 TOTAL PIPING LENGTHS(FT) INLET 136.00
DISCHARGE 56.00
SELECTION QUANTITY !
2"X 2.5"3 WAY VALVE 5 _._-----
90 DEGREE ELBOW, INLET 21
DISCHARGE 9
i
y MAIN DRAIN 1 — TEE BRANCH
INLET 1
I �niuwun
DISCHARGE O !
_ _ I
! r - CLEAN AND CLEAR RP 1 ! TEE THROUGH
INLET 0
1 k.
DISCHARGE 4
-
1 INCH RETURN 4
NO ti1AGE
--- ......._.. _. .. _...
i
SELECTION/MODEL QUANTITY 1
jar SUPERFLO VS 1
i
Results:Your TDH Calcvtation
In`et Piping:, 2.00 • Discharge Piping: 2.0'
PUMP RPM
Flow Rate at Selected Pump RPM: 76.22 Pump RPM: 3450 J
Head Loss at Selected Pump RPM: 45.74 `
I'
SYSTEM HEAD PRESSURE CURVE
BY PUMP SELECTION
80
I
I
70
x I
� I
I m
a I
60
I a �
y
u 50
ZI
j
i y I I
3 40 j
o C
a
30 o
m
v
I '
20 In
� I
I 2
10 1
0 -------- - - - - - --- --
0 10 20 30 40 50 60 70 BO 90 100
Volumetric Flow Rate(GPM) jI
f
—Clean System Curve —Pump Curve ® Desired Operation Point - Clean System ♦ Pump Operation Point
I
BACK �.' v P •o
V 11: 1
I
I
i
I
i
I
I
e The A iation of ll
v P Pool a Professionals` �J
ANSUAPSPACC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS
PROJECT NAME: DRAGMIER POOL CONTRACTOR NAME OASIS,POOLS&S PAS OF THE TREASURE COAST
,
AND ADDRESS AND ADDRESS:
10527 OAKBRIDGE CT 665 4TH STREET
VERO BEACH,FLORIDA VERO BEACH, FLORIDA 32962
OWNER: MARCELL DRAGMIER CONTRACTOR PHONE: 772-226-7196 DATE: 10-28-21
This information sheet was prepared by the APSP-15 Residential Swimming Pool and Spa Energy Efficiency Standard Writing Committee of the Association of Pool and Spa
Professionals(APSP). It is not part of the American National Standard ANSI/APSP/ICC-15 2011 but is included for information only.Contractors should acquire and comply
with the ANSI/APSP/ICC-15 2011 standard which can be purchased at www.apsp.org.
1. §5.2.1:Calculated pool volume
a. Gallons:19,443;or 1. 19,443 _
b. Calculated Gallons: (surface area)X (average depth)X 7.48 (ga1/ft^3) =!0
2.§5.2.1:Calculated maximum filtration flow rate 2. 36 qI3m
(Pool volume_360 or 36gpm whichever is larger) !
3.§5.2.2:Auxiliary Pool Load: Yes, ✓No?
(Enter the highest"auxiliary pool load"to be powered by the swimming pool filtration pump.Do not add auxilial y 3. gpm
pool load flow rates together,only the highest is used.)
4. Calculated maximum flow rate 4._ 36 gom
(Item 2 or item 3,whichever is larger.)
S.§5.5.1:Pipe sizing:
a.Minimum suction pipe diameter 5a. 1.5 inches _
(Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the same or more than item 4.)
b.Minimum suction branch pipe diameter 5b. 1.5 inches _
(Calculate:Item 4. 36 (oom)_Branch Pipes 1 (quantity)=branch flow rate 36 (aom).
Enter the smallest pipe size from Table 1 with a 6 fps flow capacity the same or more than the calculated
suction branch flow rate.)
c. Minimum return pipe diameter 5c. 1.5 inches _
(Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the some or more than item 4.)
d.Minimum return branch pipe diameter 5d. 1.5 inches _
(Calculate:Item 4. 36 (gpm)_Branch Pipes 1 (quantity)=branch flow rate 36 (gpm).
Enter the smallest pipe size from Table 1 with a 8 fps flow capacity the some or more than the calculated
return branch flow rate.)
6.§5.4.1:Filter type and size:
a.Filter type:(Cartridge, DE,Sand) •- _
b. Minimum filter area 6b. 96 sq.ft. -
(Calculate:item 4. 36 Loom)+filter(actor 0.375 )
Filter factors:Cartridge=0.375, Sand=15,Diatomaceous Earth=2
7. §5.4.2:Backwash valve: Yes, ✓ No? 7. 2.0 inches -
(When using a backwash valve,enter result of item 5c or 2 inches whichever is larger)
Table 1 Pipe Size: 1.5" 2" 2.5" 3" 3.5" ( 4" 5" i 6
Nominal GPM @ 6 fps 38 63 90 138 185 238 374 1 540
Nominal GPM @ 8 fps 51 84 119 184 247 317 499 1 720
8. Pump selection:
§5.3.2.1:Pools 17,000 gallons or less,select pump*from the database with a Curve-A gpm flow equal to item 2!or less.
§5.3.2.2:Pools 17,001 gallons or more,select pump*from the database with a Curve-C gpm flow equal to item 2 or less. *Multi-
speed pumps must have one speed listed that satisfies this requirement.
a.Pump model
b. Pump flow 8b. 98 gpm _
05.3.2.1,5.3.2.2:Applicable Curve A or C gpm flow listed in database)
I
4/5/12 ANSI/APSP/ICC-15 Standard Writing Committee Form 1 of 2
ANSI/APSP/ICC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS
Component Section Requirements Check
4.4.1.1 Heater has no pilot light
4.4.1.2 Readily accessible on-off switch mounted outside of the heater
Heaters No electric resistance heating unless for inground spa with tight fitting cover with R-6 insulation,
4.3.1.3 or for pool with 60%of documented pool heating from on-site solar or recovered energy.
4.3.2 Heater efficiency:gas/oil fired heater efficiency at least178%, heat pump COP at least 4.0 ✓
5.1.1 Pool filter pump listed in database 1
5.3.1 Pool filter pump with total horsepower 1.0 or more is multi-speed
Multi-speed pump controller programmed to default to the filtration flow rate when no auxiliary
5.3.3 pool loads are operating within 24 hours and programmed with temporary override capability for
servicing.
Pool systems 5.3.4 Single-speed pump controller capable of operating pump during off-peak electric demand.
5.5.2 Pipe before pump has at least 4 diameters of straight piIpe.
System installed with solar,or setup for the future addition of solar hleating equipment by
5.5.3 installing 18 inches of horizontal or vertical pipe after the filter and before a heater,or built-in or
built-up connections,or dedicated pipe to and from the pool. l
5.5.6 Directional inlets for mixing pool water.
I
i
I
I
I
I
4/5/12 ANSI/APSP/ICC-15 Standard Writing Committee Form 2 of 2
• •
19
Pump Performance Curves
SuperFloO VS Performance Curves for Preset Speeds
100 ...... ...............
--—----------..............
90
.......... ......... -----—i
...........i
...... ------
80
A
70
60
LL -------------
U
40
T-
30
jQuick uick Clean
(230V 1450RPMI
20 r-Q N: (230V nly)
A
Weed 1 3000 RPM 10/
(1 230-Y)
10
lck C1 ea� 0 RPM
Speed 2 1�4.09 RPM [!ed 3,2200 RPM /34
1110/23ov) '(110VOnt,
0
10 20 1 30 40 50 60 70 60 90 100 11,0 120
Volumetric Flow Rate In Gallons Per Minute
Pump Specifications Pump Dimensions
Overall Ratings
Iripuf Voltage. 115-230 Vrms nominal
lopul CU,rrent '13.21120-11;SA
-
'Input Frequency' :Sfoglo PK11Se,-5(),or6(3 Hz
18-30V AC(24V AC+/-20%)or IL I—'
9-30V DC,(12124V CC+)-20%)
Maximum Continuous Load .2.2 THP
WEF 5A THP 2,2
Speed Range 300-3450 RPM.
Environmental Rating NEMArType 3
Ambient ComiWoKs
Storage -401C[o--8VC1-40Tlo+105*) J-23.
Operating (I,c 10,5M(432'F to+='F).-.
Humidity 'Relative to 95 s5:66rkonoderming
10.07, 10.62, 12.52
-7.
14.26
[362.3]
7.
[195.9] 9.00
228.7--]
.73 8
2.21.7 7.F 612
196.G] [160.3] 11'
N,
i
�y
SECTION IV. TECHNICAL DATA
A. Filter Pressure Loss Chart B. Flow Rate Table
PRESSURE LOSS vs FLOW Residential Commercial
Maximum Cartridge Maximum Cartridge
Flow Rates Flow Rates
i
7 Product# sq.ft, GPM GPH 6 flourf00075
GPH 6 hour 8 hour
I
0_ — 160314 50 50 3,000 '18,000 1,140 6,840 9,120
y — 160315 75 75 4,500 27,000 1,680 10,080 13,440
o s
C ( 160316 100 100 6,000 36,000 2,280 13,680 18,240
s3
160317 150 150 9,600 j54,000 3,360 20,160 26,880
160318 200 150 9,000 154,000 4,500 27,000 1 36,000
(1) One GPM per sq.ft.shown,recommended flow rate for residential is.5 GPM per sq.ft.
(2) Commercial flow rate is a maximdm of 375 GPM per sq.ft.of filter area.
°a 20 40 60 so 100' 120 140' NOTE: Actual system flow will depend on plumbing size and other system components.
FLOW(9Pm)
2 ,
C. Replacement Parts
Item Part Number _ Descriptions 4
1 98209800 High Flow""manual air relief valve
2 190058 Pressure Gauge
3 178553 Lid,50, 100 sq.ft.filter
4 178561 Lid,75,150,200 sq.ft.filter
5 59052900 Locking Ring assy.
6 87300400 Body 0-ring 5.
7 59016200 Air Bleed Sock Kit
8 59053500 Center Core,50 sq.ft.filter
9 59053600 Center Core,75 sq.ft.filter _
10 59053700 Center Core, 100 sq.ft.filter
11 59053800 Center Core, 150, 200 sq.ft.filter
12 R173213 Cartridge Element, 50 sq.ft.filter
13 R173214 Cartridge Element,75 sq.ft.filter
14 R173215 Cartridge Element, 100 sq.ft.filter
15 R173216 Cartridge Element,150 sq.ft.filter I 12, 13, 14, 15, 16
16 R173217 Cartridge Element,200 sq.ft.filter
17 178562 Bottom,50 sq.ft.filter
18 178554 Bottom,.75 sq.ft.filter 17, 18, 19, 20;
19 178563 Bottom, 100 sq,ft.filter
20 178560 Bottom, 150,200 sq.ft.filter 21, 22,
21 86202000 Drain Cap Assy,
22 51005000 Drain Cap Gasket 25
23 39104500 Union Nut"C Clip 26
24 98212200 Union Nut
25 071426 Union 0-ring
26 79304600 Body,Swivel
2--
I 1