HomeMy WebLinkAboutNotice of Acceptance (2) I
.4
MI.AMI-DADS COUNTY
MIAM PRODUCT CONTROL SECTION
IN I 11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) ivww.►niamidade:eov/economy
ICP Adhesives and Sealants,Inc.
12505 NW 441h Street
Coral Springs,FL.33065
I
SCOPE:.
This,NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Daade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately evoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or mate rial fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply ,with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ICP Adhesives Polyset®AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's nam or logo, city, state and following
statement. Miami-Dade County Product Control Approved',unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of his product. J
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse o9his NOA as fan endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,.then it shall be done
in its entirety.
i
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages 1 through I I i
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 17-0322.03
MIAMI•DADE COUNTY
Expiration Date: 05/10/22 .
Approval Date: 04/27/17
Sd® all
i Page 1 of 11
i
I
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset®AH-160 as manufactured by ICP Adhesives) and Sealants,Inc. as described
in this Notice of Acceptance.For the locations where the design pressure requirements, as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP
Adhesives Polyset®AH-160..
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
ICP Adhesives N/A TAS 101 Two component polyurethane foam adhesive
Polyset®AH-160
ICP Adhesives Foam N/A Dispensing Equipment
Dispenser RTF1000
ICP Adhesives ProPack® N/A Dispensing Equipment
30& 100
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset® AH-160 roof file adhesive.
MANUFACTURING LOCATION:
1. Tomball,TX.
PHYSICAL PROPERTIES:
Proper Propertv Test Results
Density ASTM D 1622 1.6 lbs./ft.3
Compressive Strength ASTM D 1621 18 PSIOarallel to rile
12 PSI'lPerpendicular to rise
Tensile Strength ASTM D 1623 28 PSI'i Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Ft2
Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch
Dimensional Stability ASTM D 2126 +0.07%Volume Change_ @-400 F.,2 weeks
+6.0%,!Volume Change @158°F., 100%Humidity,2
weeks
Closed Cell Content ASTM D 2856 86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.: 17-0322.03
MIAMI•DADE COUNTY
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 2 of 11
i
I
EVIDENCE SUBMITTED:
Test Ageney Test Identifier Test Name/Report Date
Center for Applied Engineering #94-060 TAS 101 04/08/94-
257818-IPA TAS 101 12/16/96
25-7438-3 ! SSTD 11-93 10/25/95
25-7438-4
25-7438-7 SSTD 11-93 11/02/95
25-7492 SSTD 11-93 12/12/95
Miles Laboratories NB-589-631 ASTM D 11623 02/01/94
Polymers Division
Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93
Southwest Research Institute 01-6743-011 ASTM E 1,08 11/16/94
01-6739-062b[1] ASTM E 84 - 01/16/95
Trinity Engineering 7050.02.96-1 TAS 114 03/14/96
P36700.04.12 ASTM D 1623 04/18/12
P39740.02.12 TAS 101 02/21/12
TAS 123
Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
I
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset®AH-160 shall solely be used with flat, low, &high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset®AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in,accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
i
MIAMI•DADE COUNTYIE
j NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 3 of 11
I
' I
i
INSTALLATION:
1, ICP Adhesives Polyset®AH-110 may be used with any roof tile assembly having a current NOA that lists
11
attachment resistance values with the use of ICP Adhesives Polyset®AH-160.
2. ICP Adhesives Polyset®AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset®AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset®AH-160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by ICP Adhesives and
Sealants, Inc. ICP Adhesives and Sealants,Inc. shall supply a list'of approved applicators to the authority having
jurisdiction.
5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application
of any adhesive. The mix ratio between the "A" component and the"B" component shall be maintained between
1.0-1.15 (A): 1.0(B).
6. ICP Adhesives Polyset®AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP
Adhesives ProPack®30 & 100 dispensing equipment only.
7. ICP Adhesives Polyset®AH-160 shall not be exposed permanently to sunlight.
S. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives
Polyset®AH-160 has been dispensed.
9. ICP Adhesives P olyset AH-160 placement and minimum patty weight shall be in accordance with the
'Placement Details' herein. Each generic tile profile requires the specific placement noted herein.
I
I
I
I
I
MIAMI•DADE COUNTY
NOA No.: 17-0322.03
••••� � Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 4 of 11
I
I
d
i
I
I
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram
j Area Weight
Eave Course-Flat,Low,High All Eave Course 1723 23 sq. inches 45-65
Profiles
Flat,Low,High Profiles #1 17-23 sq. inches 45-65
Flat Profile #2 1012 sq. inches 30
Low Profile #2 12�'�14 sq. inches 30
High Profile #2 17i 19 sq. incheI 30
Flat,Low,High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy
head of the 9-11 sq. inches at
overlap
Two-Piece Barrel (Cap Tile) Two Piece 2 Beads(I each longitudinal 17 grams per bead
edge) 26-25 sq. inches each
bead
I
Two Piece Barrel (Pan Tile) Two Piece 65170 sq. inches 34 grams under pan
I
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami-
Dade County Product Control Seal as shown below.
�j
MiA�i!i!�•C=E COUNTY
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
1
I
i
I
I
I
I
j
I ;
MIAMI•DADE COUNTYZI
NOA No.: 17-0322.03
Expiration Date: 05/10/22
j Approval Date: 04/27/17
Page 5 of 11
I
I
i
i
ADHESIVE PLACEMENT DETAIL# 1
Ma d iPaddy[st auftT&O Flat/Low Profile Tile
***ft ufr,ssl``
MliilrrtsytnMnl ,1 �+n fi I� '
..4 � 1. Starting at the eave course, apply a minimum 2"
~ (5018 mm)x 10" (254 mm)x 1"(25.4 mm)foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the tile being set.
E.vetourrr.• �� X: r' 2. Continue in same manner. Insure approximately 17
f (109.7 cmZ)—231(148.4 cm-)square inch adhesive
a Via.
contact with the underside of the tile.
IC
f
El" Claduro
Nall tnroughpYastiscemerst Medium Profile/ Double Pan Tile
Iwhem required)
N-Wyip,.wh<ra t 1. Starting at the eave course, apply a minimum 2"
dI;ymMe x `. (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
t paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
10in.z•
tr ln.widar�r
�. .
F1 rffiatt ens opgloaal 2. Conapproximately tinue in same manner. Insure 17
`"•�_'°. ./ i
(109.7 cmZ)—23 (148.4 cmz)square inch adhesive
contact with the finderside of the tile.
Ewa Aclacwrfi
vr�taurse � Fascia
I
I 11*04C 6 p100041C n- High Profile/Single Pan Tile
(whanrrquiucdV �.. Pssldjrl�enri4Va�i141 I
1. Starting at the eave course, apply a minimum 2"
(50i8 min)x 10" (254 mm)x 1"(25.4 mm)foam
v -
�* ~�. paddy onto the underlayment positioned'as shown
2anndo under the pan portion of the the closest to the
4 - ; overlock of the the being set.
AR
2. Continue in same manner. Insure approximately 17
aprtsonaE
g� (109.7 cm')—23 (148.4 cmZ)square inch adhesive
`y IA3 contact with the underside of the tile.
Fascia
i►' (aYb Cburst_'_ y r
Weephate
G� t,
10 Irk• Emrifotum
brlpadym
NOA No.: 17-0322.03
MIAMI•DAD;COUNTY I Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 6 of 11
ADHESIVE PLACEMENT DETAIL##2
l4iilthro4ghpfaufcaymnnt PySdy(i3vi?►ihTli] Flat/Low Profile Tile
�`wh•wri�uiradati �-'''�'�--> .jr'1 i
o"d°&°"f°"• •, 1. Startinlg at the eave course, apply a minimum 2"(50.8
mm)xi 10"(254 mm)x 1"(25.4 mm)foam paddy
¢ onto the underlayment positioned as shown under the
strengthening rib of the the closest to the Overlock of
yrr ti
a.� .'` •.--� the the being set. Insure I approximately 17(109.7 cmZ)
3 (148.4 cm ) square inch adhesive contact with the
Eawtaursa ��'F .. �% underside of the tile.
2. At the second course' apply a minimum 2 (50.8mm)
l �
``. ►,, �•' ,'"*'• �,f�`rar�� x 7" (177.8 mm)x 1"(25.4 mm)foam paddy onto the
f t' underlayment positioned as shown under the
gave Closure strengthening rib cl{sest to the Overlock of the the
being set.
3. Continue in same manner. Insure approximately 10"
(64.5 11 - 12 (77 14 cmZ)square inch adhesive
contact with the underside of the tile.
I j
Naiilrthraugh plastic csmen±t Medium Profile/Double Pan Tile
4wher•riquiredl
f _� -ParWy�Banrash fllay 1. Startirig at the eave course, apply a minimum 2"(50.8
„a„lrym.nt �~'`•. mm) x 10"(254 mm)x-1"(25.4 mm)foam paddy
~� onto the underlayment positioned as shown under the
pan portion of the the closest to the overlock of the
tile being set. Insure approximately 17(109.7 cm')—
2 in. 23 (148.4 cm') square inch adhesive contact with the
v.
6atPeasaptianal , underside of the tile.
2. At the,lsecond course, apply a minimum 2"(50.8mm)
x 7"(177.8 mm)x 1"(25.4 mm) foam paddy onto the
'., LWO c0ours underlayment positioned as shown under the pan
eaw4cwtr•. a � F,r,«, portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2)- 14 (90,3 cmZ) square inch adhesive
contaci with the underside of the tile.
(Instructions continued on next page)
I
MIAMI•DADE COUNTY NOA No.: 17-0322.03
• Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 7 of 11
i
ADHESIVE PLACEMENT DETAIL#!2 (CONTINUED)
I
killtkmughpLudcca High Profile/Single an Tile
�.Nhan ragalred! {,� Puddp IBanwahTilit� g g
1. Startirig at the eavel course,apply a minimum 2" (50.8
mm) x 10"(254 mm)x 1"(25.4 mm) foam paddy
onto the underlaym�ent positioned as shown under the
pan portion of the tIi le closest to the overlock of the
-- � `� `� . tile being set. Insure approximately 17(109.7 cmZ)—
�'t' l� ' 23 (148.4 cm'
)square inch adhesive contact with the
d�ttansapeloaal s` •' underside of the tile.
2. At the second course, apply a minimum 2"(50.8mm)
x Eave Causm Fakia x 7"(;177.8 mm)x (25.4 mm)foam paddy onto the
Woapbaw underlayment positioned as shown under the pan
loin tam caw dolum portion of the tile closest to the overlock of the tile
being',set.
3. Continue in same manner. Insure approximately 17"
(109.7 cm-) - 19(122.6 cm 2)square inch adhesive
contact with the underside of the tile. .
I
i
i
I
NOA No.: 17-0322.03
MIAMI•DADE COUNTY
t Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 8 of 11
i
j
ADIIESWE PLACEMENT DETAIL I#3 '
Mail dunugh plasticcement(when requi Pared► T(between tiles) 1. On the eave course only, apply a minimum 2"
(50.8
Battensoptional mm)x 10" (254 mm)x 1" (25.4 mm) foam paddy
° Paddy iunderdlc) onto the underlayment positioned as shown, under
Yan top oft0e
the,strengthening rib for flat tile or under the pan
` portion of the tile'for low or high profile tile closest
4X4(n. to the overlock of the tile being set.Leave
� � approximately 4I' (101.6 mm)up from the eave
singlepaddy , edge free of foam to prevent the expanded adhesive
�,
onundeetlayment 2X4in. from blocking the weep holes. Insure
t approximately 1 -23 in (109.7-148.4 cm') of
101 " adhesive contact with the underside of the tile
2in. �
ra,reaosure. 2. Apply a 4" (101!6 mm)x 4" (101.6 mm)x 1" (25.4
NMI mm) foam paddy onto the underlayment just below
Flat/Low Profile Tile the'second course lirie positioned foam paddy
Nagunder the strengthening rib for flat tile, or under the
(WhenFeWltelasUcoemsnt 51ng)epaddyundertile an portion of the the closest to the underlock for
(when retlttUed) P p ,
Paddyibetwwntiles) the second course tile to be installed. Insure
approximately 8i 9 in'(51.6-58.1 cm')of adhesive
MUMS Paddcoo" ylundertilel contact with the underside of the tile.
Sinoe
on MapoFdule '` (Instructions continued on next page)
/J! x 41n. 2 x 4 ip:�
sin ylepaddyan
underhyrraent
t
�b
^h
10 `' 2 in.
Eave Qosure
Eave Coutse Fasda
Medium ProffieTlle
I
' I
I
I
•D®uNTr
NOA No.: 17-0322.03
MIAMI Expiration Date: 05/10/22
� t
Approval Date: 04/27/17
Page 9 of 11
I
i
e
I
I '
I
y
ADHESIVE PLACEMENT DETAIL#13 (CONTINUED)
Na through plastic Si 4e paddy under file
lw,enmqufretO 3. Also apply a 2" i50.8 mm)x 4" (101.6 mm)x 3/4"
Pamyibetwiemtilesl (191mm)paddy on top of the eave course tile
Bartem surface as shown,on top of the strengthening rib
optTanai Paddy fonder tile)
for flat the or on stop of the pan portion of the tile,
closest to the underlock of the first course of tile.
�� Install second course of tile. Insure approximately
on ullaefla r 9 (5�8.1 cm')- 11I(71cm2) square inch adhesive
4x4in. q
g * .
contact with the underside of the tile at the overlap
2:sin
andl7 (45.2 cm2) 9 (58.1 cmz)square inch
toptfe adhesive contact with the underside of the tile at
ti the head of the tile. Continue in same manner.
i
Pave Course Fascia ;!
Weephole j
toin. 2in.
Ewe closure
i Drip edge
High PraflleTtle j
I
I
i
i -
II
I
i
I -
j
i
i
NOA No.: 17-0322.03
MIAMI-DADE COUNTY Expiration Date: 05/10/22
' Approval Date: 04/27/17
I
Page 10 of 11
j
I
I
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
I
Two Piece Barrel(Cap and Pan)Tile
1. Starting at the gave course,apply a minimum 2"
t)Place enough adhesive to achieve 65 to 70 sq in. Steep pitch applications
In contact with the pan tile. (when required) (50.8 mm)x 10"(254 mm)x 1"(25.4 mm) foam
2)Turncovers upside down.Piace adhesive In paddy onto the underlayment positioned as
toe install
outside edgee20to of mile. shown under two adjacent pan tiles. Support eave
Then install the tile.Ensure 20to
25 sq.in.contact area. .o tiles from rocking until adhesive has a chance to
Underlayment �' ,�' cure.
�! P �r 2. Continue in same manner bringing two pan
d�f ✓A.z��£'� �.Ri.� r , c ' 1
courses up toward the ridge. Insure
approximately 65 (419.4 cm2)—70 (451.6 cm2)
square inch adhesive contact with the underside
r� of the an tile.
$ i yam' Sheathing p
Eave closure
(motarshown) 3. Turn covers upside down exposing the underside
weephole Fascia Board of the tile. Apply a minimum 1"(25.4 mm)x 10"
(254 mm)bead of adhesive directly on the inner
Remove top portion of the eave course cover tile.Abut to second course of edge of each side of the cover tile.Leave
pan tiles.,Ensure eave and of pan and cover tiles.are flush at eave line. I I
approximately 3/4"(19 mm)to 1"(25.4 mm)
Two Piece Barrel-High Profile Tile from the outside edge of the tile,inward,free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan Mile course. Insure a minimum of
20 (129 cm')-25 (161.3 cm')square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive.Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required,2"(50.8
mm)x 4"(1.01 16 mm)nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
I
i
NOA No.: 17-0322.03
MIAt�ti•DAne couNT�r Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 11 of 11
I