HomeMy WebLinkAboutLETTER ENGINEERINGArchitectonic Inc 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1 January 5, 2022 St. Lucie County Building Department Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982 RE: 5510 Killarney Avenue Fort Pierce, FL 34951 To Whom It May Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed Window is incompliance with the 2020 Florida Building Code, 160 mph wind zone, exposure “C”, risk category II. Exposure “C” Multiplier for 20’ mean roof height is 1.21 Wind Zone 4 28.7 x 1.21 = 34.7 Wind Zone 5 34.5 x 1.21= 41.7 Required Design Pressures: +/-41.7 Product: Series DS-300 Window, FL# 15963.2, Window Craftsman, Inc. Product Pressures: +/-50 Respectfully Submitted, _________________________________ Michael Seal, AIA AR96898 Architectonic, Inc.