DESIGN PRESSURE CALCULATIONS
Property Information Owner:GELLER, DAVID / ANNE Address:6144 SANTA MARGARITO DR. FORT PIERCE, FL. 34951 Building Information Wind Zone:170 MPH. Exposure Category:C Minimum Building Dimension:48 ft. Mean Roof Height:20 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 51 72 7 37.7 -48.9 2 Int 72 61 7 37.2 -40.6 3 Int 72 35.5 7 38.7 -42.1 4 End 104.75 61 7 36.3 -46.0 5 End 24.75 61 7 40.0 -53.5 6 End 104.75 61 7 36.3 -46.0 7 End 35.25 49 7 39.7 -52.8 8 End 34 34 14 40.2 -53.8 9 End 35.25 56 14 39.3 -52.1 10 End 35.25 56 14 39.3 -52.1 11 End 51.25 61 14 38.1 -49.7 12 End 51.25 25.5 14 40.2 -53.8 13 End 72 46 14 38.0 -49.4 14 End 35.25 56 14 39.3 -52.1 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1