Loading...
HomeMy WebLinkAboutAPPROVED, Merge Result (54) Weiserma 1.12.2022 (1)GENERAL NOTES TO A/E FOR CORRECTIONS BEFORE SUBMISSION OF BID. A/E SHALL BE NOTIFIED PRIOR TO PROCEEDING WITH ANY WORK. CONDITIONS PRIOR TO SUBMISSION OF BID. OF HIS/HER RESPONSIBILITY. PROPERTIES. STRUCTURES. COMPENSATION INSURANCE ON ALL WORKMEN EMPLOYED ON THIS JOB. CRAFTSMANSHIP BY JOURNEYMEN OF THE REPECTIVE TRADES.8. INCLUDED IN THE RESPONSIBILITES OF ITEM 7 ARE THE FOLLOWING:9. ROOF TRUSS FABRICATOR TO PROVIDE DESIGN AND SHOP DRAWINGS FOR TRUSSES. ADDITIONAL EXPENSE TO THE OWNER. MODIFIED PROCTOR METHOD.10. SOIL SHALL BE COMPACTED TO A MINIMUM OF 9511. SOIL BEARING IS DETERMINED TO BE 2500 PSF. IF SITE CONDITIONS VARY,12. SOIL SHALL BE PRE-TREATED FOR SUBTERANEAN TERMITES CONTACT ENGINEER OF RECORD.1. GENERAL CONTRACTOR AND ALL SUB CONTRACTORS SHALL VISIT THE BUILDING SITE AND VERIFY ALL2. ANY ERRORS, AMBIGUITIES AND OMISSIONS IN THE DRAWINGS AND OR SPECIFICATIONS SHALL BE REPORTED3. UNLESS EXPRESSLY STIPULATED, NO ADDITIONAL ALLOWANCE WILL BE MADE IN THE CONTRACT AND/OR MANUFACTURES FAVOR OR BY VIRTURE OF ERRORS, AMBIGUITIES AND/OR OMISSIONS WHICH SHOULD HAVE BEEN DISCOVERED DURING THE PREPARATION OF BID ESTIMATE AND DIRECTED TO A/E ATTENTION IN A TIMELY MANNER.4. WRITTEN DIMIENSIONS GOVERN. CONTRACTOR SHALL VERIFY ALL DIMIENSIONS. IN THE EVENT OF CONFLICT, THE5. CONTRACTOR AND SUBCONTRACTORS DOING WORK ON THIS PROJECT SHALL FURNISH DAMAGE INSURANCE AGAINST ACCIDENTS OF ALL KINDS AND THE OWNER SHALL BE FURNISHED WITH A CERTIFICATE OF SAID INSURANCE. CONTRACTOR AND ALL SUBCONTRACTORS SHALL CARRY WORKER'S6. ALL WORK PERFORMED SHALL CONFORM TO THE LATEST EDITION OF THE 2010 FLORIDA BUILDING CODE AND ALL APPLICABLE COUNTY ORDINANCES, AND SHALL BE COMPLETED TO THE HIGHEST STANDARDS OF7. CONTRACTOR IS RESPONSIBLE FOR THE PROPER EXECUTION OF ALL WORKS, NOT WITHSTANDING THE APPROVAL OF SHOP DRAWINGS, DESIGN MIZED, LABORATORY INSPECTIONS AND REPORTS, ARCHITECTS AND/OR ENGINEER'S FIELD OBSERVATIONS, THE LIKE OF WHICH ARE INTENDED TO ASSIST BUT IN NO WAY RELIEVE THE CONTRACTOR A. EXECUTION OF ALL WORKS IN A PROPER AND SAFE MANNER FOR ALL PERSONS, EQUIPMENT AND B. DESIGN, ENGINEERING, CONSTRUCTION AND HANDLING OF AL FORM WORK AND TEMPORARY C. SPECIFIED STRENGTH AND PROPER PLACING OF CONCRETE. ALL CONCRETE AND RELATED WORK INPROPERLY PLACED AND/OR TESTING UNDER STRENGTH SHALL BE REPLACED WITHOUT ANY13. ALL PERMIT FEES SHALL BE PART OF THE BASE BID OR PROVIDED IN BASE BID AS AN ALLOWANCE.SUBMIT SHOP DWGS FOR WRITTEN APPROVAL BEFORE FABRICATING FIRST ANS SECOND FLOOR ELECTRICAL PLANS PLUMBING PLAN / RISER DIAGRAMFOUNDATION PLANROOF FRAMING PLANP-1TYPICAL WALL SECTIONSARCHITECTURALSITE PLAN / SITE DATA / DESIGN CERTIFICATIONA-7A-6A-5A-1A-3A-2A-4 FLOOR PLANSE-1 EXTERIOR ELEVATIONSBUILDING DEPARTMENT FORMSWINDOW AND DOOR SCHEDULESA-8STAIR SECTIONS & DETAILSA-9FIRST FLOOR AND SECOND FLOOR FRAMING PLANSA-1014. WEATHERING AND TERMITE PROBABILITY AREA TO ADHERE TO FLA RES 2010 TABLE 301.2-1A. WEATHERING IS "NEGLIGIBLE" FOR CONCRETE AS DETERMINED FROM THE WEATHERING PROBABILITY MAP [FIGURE R301.2(3)]. THE GRADE OF MASONRY UNITS SHALL BE DETERMINED FROM ASTM C 34, C 55, C 62, C 73, C 90, C 129, C 145, C 216 OR C 652. E-2ELECTRICAL SCHEDULESSECTIONS A, B , C.A-11 CONTRACTOR TO NOT DEVIATE IN ANY WAY FROM THE WORKING DRAWINGWITHOUT WRITTEN PERMISSION FROM THE ENGINEERMECHANICAL PLANM-1 MECHANICAL SCHEDULE AND NOTESM-2WEIRSEMA2024.0 ' NAVD4: 1210725 S OCEAN DR. LOT 387 FROM PROPERTY APPRAISERSJENSEN BEACH, FL. 34957NAX3'-0"170 mph- 10DN.A.551530XXRISK CATEGORY 11X± 0.18-45.8-69.6-117.6-54.2-63.3X+42.6 -46.9DAN AND MICHELLE WEIRSEMANAASPECT RATIO IS < 4 : 1A-1 DATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. ST. LUCIE COUNTY FLORIDA 34996 6-18-21 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 382 NETTLES ISLAND 1-11-22 BLDG DEPT. COMMENTS SITE CALCULATIONS LEGAL DESCRIPTIONLOT 160, NETTLES ISLAND, SECTION 2, ACCORDING TO THE PLATTHEREOF, AS RECORDED IN PLAT BOOK 16, PAGE(S) 1, 1A THROGH16J, PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA.SITE PLAN 18" =1'-0"PAVERS DETAIL 34" = 1'-0"A-2 DATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. ST. LUCIE COUNTY FLORIDA 34996 6-18-21 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 382 NETTLES ISLAND DATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. ST. LUCIE COUNTY FLORIDA 34996 6-18-21 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 382 NETTLES ISLAND 12-27-21 BLDG DEPT. COMMENTS FOUNDATION NOTES1) SLAB TO BE 6"THICK SUPPORTED ON SLAB BOOSTER @ 6'-0" O.C. ON6 MILL VAPOR BARRIER ONCOMPACTED FILL TO A MIN FOR ALL LAYERS IN ACCORDANCE WITH ASTM D 15572) TOP OF SLAB = TO BE AT 5.0' NAVD.3) OVERLAP ALL FOOTING STEEL AT ALL CORNERS & INTERSECTIONS FOR 30" ( MIN. BEND BARS4) CENTERLINE OF FOOTING AND WALLS, COLUMNS MUST LINE UP U.O.N.OF 95% OF MAX DRY DENSITY FOR ALL LAYERSMASONRY REINFORCINGALL CONCRETE BLOCK TO BE 8"x8"x16" WITH MIN. COMPREESSIVESTRENGTH OF F'm = 1900 P.S.I. RESULTING PRISM PROVIDE 1-No.5 IN FILL CELLS WITH CEMENT PUMP MIX CONCWET CELLS BEFORE PLACING GROUT PROVIDEHORIZONTAL REINFORCING #9 GAGE LADDER TYPE EVERY OTHER COURSE THRU-OUT ALL MASONRY WALLS.MASONRY AT A MAX SPACING OF 48" O.C. ( U.O.N. )TERMITE NOTEFOUNDATION PLAN 14"=1'-0"STL COL SECTION 34" =1'-0"DATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. ST. LUCIE COUNTY FLORIDA 34996 6-18-21 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 382 NETTLES ISLANDA-3 1-11-22 BLDG DEPT. COMMENTS BEDROOM # 3BEDROOM # 4MASTERBEDROOMBEDROOM # 2KITCHENMASTERBATHBATHLAUNDRYSTORAGESTAIRSSTAIRSW.I.CLOS.CLOS.W.I.CLOS.CLOS.OPEN TO FIRST FLOOR ROOFENTRYCLOS.BATHBATHFAMILY ROOMFOYERGENERAL NOTEALL MATERALS BELOW FLOOD LEVEL@ 8'-0" SHALL ADHERE TO R-322.1.8TO BE FLOOD RESISTANTKEYNOTESSECOND FLOOR PLAN 14"=1'-0"FIRST FLOOR PLAN 14"=1'-0"CONTRACTOR TO VERIFY ALL DIMENSIONS AND INCASE OFA DESCREPENCY SHALL NOTIFY ENGINEER BEFORE PROCEEDING W/ WORK11DATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. ST. LUCIE COUNTY FLORIDA 34996 6-18-21 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 382 NETTLES ISLANDA-4 12-27-21 BLDG DEPT. COMMENTS FRONT / SOUTH ELEVATION 14"=1'-0"LEFT SIDE / WEST ELEVATION 14"=1'-0"REAR / NORTH ELEVATION 14"=1'-0"RIGHT SIDE / EAST ELEVATION 14"=1'-0"14'-8 1/2"11DATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. ST. LUCIE COUNTY FLORIDA 34996 6-18-21 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 382 NETTLES ISLANDA-5 12-27-21 BLDG DEPT. COMMENTS ROOF PLAN 14"=1'-0"1345678291011131412AA-11AA-11SIMPSON CONNECTORSTC-1 HETA 16TC-2 FGTRTC-3 MGTTypical HGT-2 Installation into Concrete10,346 u.l.LENGTHALLOWEDAPPLIEDGRAVITY ( LBS / FT. )UPLIFT lBS / FT. )ALLOWEDAPPLIEDLINTELSPECIFICATION8F161B1T213456789101112131461134'-6"272461136'-6"348018803'-6"611335474'-6"272461134'-6"272461134'-6"2724611335473'-6"611335473'-6"611335473'-6"611335473'-6"6'-6"34801880460521924'-0"8F121B1T611335473'-6"4'-6"194043758F121B1T1516250250250250817633578385250550413550688250100100100100100638452495301430430323528100TDATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. ST. LUCIE COUNTY FLORIDA 34996 6-18-21 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 382 NETTLES ISLANDA-6 12-27-21 BLDG DEPT. COMMENTS SECOND FLOOR FRAMING PLAN 14"=1'-0"1516171819POST DETAIL SCALE 3/4=1'-0"LENGTHALLOWEDAPPLIEDGRAVITY ( LBS / FT. )UPLIFT lBS / FT. )ALLOWEDAPPLIEDLINTELSPECIFICATION8F161B1T21345678910111213148F121B1T15167'-6"19'-4"172947022210216'-6"171821771340460525243'-6"193'-6"46052524250372250OOOOOOOA-7 DATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. ST. LUCIE COUNTY FLORIDA 34996 6-18-21 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 382 NETTLES ISLAND TYPICAL TWO STORY SECTION SCALE 3/4"=1'-0"GALV. MTL ON P.T. 1x3 WD NAILERTYPICAL FIRST FLOOR SECTION SCALE 3/4"=1'-0"GALV. MTL ON P.T. 1x3 WD NAILERTRUSSES AT O PROPERTY LINE SCALE 3/4"=1'-0"DATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. ST. LUCIE COUNTY FLORIDA 34996 6-18-21 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 382 NETTLES ISLANDA-8 DETAIL # 1 1-12" =1'-0"DETAIL # 2 1-12" =1'-0"DETAIL # 3 1-12" =1'-0" STAIR SECTION" 34" =1'-0"STAIRS SHALL CONFORM TO THE FBC 2020 RES. SEC 311.7GUARD OPENING SHALL COMPLY W. FBC 2020 RES SEC 312.1.3A-9 DATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. ST. LUCIE COUNTY FLORIDA 34996 6-18-21 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 382 NETTLES ISLAND 12-27-21 BLDG DEPT. COMMENTS MULLION DETAIL " A " 1-12"=1'-0"MULLION PLAN VIEW " A " 1-12"=1'-0"S1/4"FRONT DOOR DETAIL 112"=1'-0"REMARKSSIZEDOOR SCHEDULETHK.TYPE & MAT.HWMARKMFG.DESCRIPTIONUNIT SIZEMARK W H RADIUSMANUF.REMARKSWINDOW SCHEDULEA-10 DATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. ST. LUCIE COUNTY FLORIDA 34996 6-18-21 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 382 NETTLES ISLAND 12-27-21 BLDG DEPT. COMMENTS MASTERBEDROOMKITCHENSECTION "A " 14"=1'-0"SECTION "A " 14"=1'-0"BEDROOM # 3HALLA-11 DATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. ST. LUCIE COUNTY FLORIDA 34996 6-18-21 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 160 NETTLES ISLAND TVEWNACJQUADRAPLEX RECEPTACLE OUTLETHALF SWITCHED RECEPTACLE OUTLETA/C THERMOSTATSPEAKERWIRELESS NETWORK ANTENASPECIAL RECEPTACLE OUTLET 240VDUPLEX RECEPTACLE OUTLETDEDICATED RECEPTACLE OUTLETWEATHERPROOF GROUND FAULT INTERRUPTER OUTLETGROUND-FAULT INTERRUPTER OUTLETWPGFIGFICEILING RECESSED LIGHT FIXTURE - VAPOR PROOFCEILING RECESSED LIGHT FIXTURE - DIRECTIONALFLUORESCENT LIGHTING FIXTURE - SURFACE MTD.FLOOD LIGHTCEILING MOUNTED LIGHTING FIXTUREWALL MOUNTED LIGHTING FIXTUREPADDLE FAN LIGHT COMBOSMOKE & CARBON MONOXIDE DETECTOR COMBOPUSHBUTTON SWITCHFUSE OR DISCONNECT SWITCHTELEVISION JACKTELEPHONE JACKELECTRICAL PANELCEILING RECESSED LIGHTING FIXTUREEXHAUST FANDUPLEX FLOOR RECEPTACLEVPSYMBOL LEGENDWALL SWITCHJUNCTION BOXCHIMESD & CMDCEILING RECESSED LIGHT FIXTURE UNDERCOUNTER LTSSD & CMDSD & CMDSD & CMDSD & CMDSD & CMDBEDROOM # 3BEDROOM # 4MASTERBEDROOMBEDROOM # 2KITCHENMASTERBATHBATHLAUNDRYSTORAGESTAIRSSTAIRSW.I.CLOS.CLOS.W.I.CLOS.CLOS.OPEN TO FIRST FLOOR ROOFENTRYCLOS.UNDER COUNTER LED LTSEEFAN AND LIGHTFAN & LIGHTFAN & LIGHTFAN & LIGHTFAN & LIGHTEESECOND FLOOR ELECTRICAL FLOOR PLAN 14"=1'-0"FIRST FLOOR ELECTRICAL FLOOR PLAN 14"=1'-0"SD & CMDSOFFIT LITS ON TIMERS.L.S.L.S.L.S.L.S.L.S.L.S.L.S.L.S.L.S.L.S.L.S.L.DATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA DON J. NUELLE , P.E. 34996 6-18-21 P.E. # 52046 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 382 NETTLES ISLANDE-1 *PANEL " A "********ELECTRICAL NOTESSMOKE DETECTOR SHALL BE 120 V. WITH BATTERYBACK-UP & ALL SMOKE DETECTORS MUST BEINTERCONNECTED.SWITCHSMOKE DETECTOR CONNECTION DETAIL nts* SIZE AS PEREQUIP. NAMEPLATEA/C CONNECTION DETAIL nts24 OV. 2 P. FUSE SWNEMA 3R. FOR COND.UNIT SIZE AS PER A/CNAMEPLATESUB-PNL W/ TWO 2P. BRKS. NEMA-1 INFAN-COIL CLOSET*ELECT.PNL**FAN-COILSWITCHLEGKITCHEN ORBATHROOM LIGHTSMOKE DETECTORLINE SIDE OFSWITCHPHASE CONDUCTOR120 V.SDNONMETALICPROTECTIVESLEEVEBOLTED-TYPE CONNECTION DEVICE OREXOTHERMIC WELDDIRECT CONTACT WITHEARTHNo. 4 AWG OR LARGER BARE COPPER CONDUCTOROR STEEL REINFORCING BAR OR ROD NOT LESSTHAN 1/2- INCH DIAMETERENCASED GROUNDING ELECTRODE DETAIL2 in.MIN.20 FTMIN.NOTE:NON METALIC - SHEATHEDCABLE(ROMEX CABLE) SHALLCOMPLYWITH NFPA-10 ARTICLE 336PARTICULARLY PARAGRAPH336-10-7 AND ALSO WITHCHAPTERS 250 300 AND 310.CONCRETEFOUNDATIONGROUNDINGELECTRODEGROUNDINGELECTRODECONDUCTORCONNECT TO A CONCRETE-ENCASED ELECTRODECONSISTING OF AT LEAST 20 FT OF ONE OR MOREBARE OR ZINC GALVANIZED STEEL REINFORCINGBARS OF NOT LESS THAN 1/2 INCH OR CONSISTINGOF AT LEAST 20 FT OF BARE COPPER CONDUCTORNOT SMALLER THAN No. 4AND LOCATED WITHINAND NEAR THE BOTTOM OF A CONCRETEFOUNDATION OR FOOTING THAT IS IN DIRECTCONTACT WITH EARTH.ELECTRICAL INSTALLATION BELOW FLOOD LEVELPROVIDE "AFCI" BREAKERSAT ALL BEDROOM OUTLETS TO COMPLY WITHNEC. 210.12 ( B )RISER DIAGRAMNTSE-2 DATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. ST. LUCIE COUNTY FLORIDA 34996 6-18-21 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 160 NETTLES ISLAND EEEBEDROOM # 3BEDROOM # 4MASTERBEDROOMBEDROOM # 2KITCHENMASTERBATHLAUNDRYSTAIRSSTAIRSW.I.CLOS.CLOS.W.I.CLOS.CLOS.OPEN TO FIRST FLOOR ROOFENTRYCLOS.BATH MECHANICAL FIRST FLOOR PLAN 1/4"=1'-0" MECHANICAL SECOND FLOOR PLAN 1/4"=1'-0"ESDDATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA DON J. NUELLE , P.E. 34996 6-18-21 P.E. # 52046 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 382 NETTLES ISLANDM-1 CONDENSING UNIT MOUNTING DETAIL ntsON PLANS, 1.5 SONES NOISE CRITERIAEXHAUST CEILING FAN, CFM AS NOTEDEAIR CONDITIONING SCHEDULE ( RHEEM UNITS )AC No CONDENSERMODEL NUMBERAIR HANDLERMODEL NUMBERCOOLING CAPACITYTOTALSENSIBLELATENTCFMSEERREFRIGERANT LINESSUCTIONLIQUIDA.H.UWEIGHTCONDA.H.U. HxWxDDIMENSIONSCOND. HxWxDHVAC DESIGN REQUIRESDUCT SMOKE DETECTORFIRE DAMPERSSMOKE DAMPERSFIRE RATED ROOF/ FLOORCEILING ASSEMBLYFIRE STOPPINGSMOKE CONTROLYESNOXXXXXXTONSMATERIALS AND LABOR FOR A COMPLETELY OPERATIONALDATE OF ACCEPTANCE.REFRIGERANT PIPING. SEAMLESS COPPER TYPE "L" ANDPROVIDE VOLUME EXTRACTORS BEHIND EACH SUPPLYPROVIDE DOUBLE THICKNESS TURNING VANES AT ALLWITH SMACNA'S LOW PRESURE DUCT MANUAL. ALLDESIGNED, CONSTRUCTED AND INSTALLED IN ACCORDANCEGENERAL. ALL DUCT SIZES SHOWN ARE CLEAR INSIDEPOUNDS DENSITY 1 1/2 " THICK GLASSFIBERAND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROMGUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALSJACKET. PAINT ALL EXPOSED INSULATION WITH TWOINSULATION, WITH AN APPROVED PIPE AND SMOKEINSULATE ALL REFRIGERANT SUCTION PIPING WITH 3/4"WROUGHT COPPER SOLDER JOINT FITTINGS, SOLDERHARD OR SOFT DRAWN ON ACR COPPER TUBING WITHCOATS OF WHITE LATEX PAINT.CLOSED CELL POLYETHYLENE PREMOLDEDSHALL BE 95/5 APPLIED WITH SUITABLE FLUX.INSTALL SINGLE THICKNESS INSTEAD.OUTLET AND AT EACH DUCT BRANCH.SQUARE ELBOWS. WHERE THE ELBOWS AREDUCT JOINTS SHALL BE SEALED AND TAPED.ASHRAE,PAY FOR ALL FEES, INSPECTIONS AND CONNECTIONAIR CONDITIONING UNITS WITH REFRIGERANT PIPINGAIR CONDITIONING, HEATING AND VENTILATING SYSTEM ASPROVIDE ( FURNISH AND INSTALL ) ALL NECESSARYSCOPE OF WORK :AND CONTROLS.EXHAUST SYSTEM FOR BATHROOMSSUPPLY AND RETURN DUCT SYSTEM.PROVIDE THE FOLLOWING COMPLETE SYSTEMS :SHOWN ON THE DRAWINGSINSTALL IN ACCORDANCE WITH THE FLORIDAVERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONSAND EQUIPMENT SIZES PRIOR TO DUCT FABRICATIONAPPROVAL BEFORE PROCEEDING WITH THE PURCHASE ORSUBMIT SHOP DRAWINGS FOR ARCHITECT / ENGINEERINSTALLATION. COORDINATE REQUIREMENTS TO AVOIDINTERFERENCE WITH OTHER TRADES.INSTALLATION OF EQUIPMENT AND MATERIALS.CHARGES REQUIRED1.21.51.31.4C.A.B.GENERALBUILDING CODE,ORDINANCES.1.01.1FIVE2.1.2MATERIAL.AND KITCHEN..OR2.32.1.42.22.1.3AND HEREIN SPECIFIEDNFPA, AND LOCALSMACNA,MATERIALSDIMENSIONS.DUCTWORK2.02.1.12.11.6OF ACCEPTANCE OF THE PROJECT.AIR DISTRIBUTION PRODUCTS :PROVIDE FINISHES AND TYPESBEHIND ALL AIR SUPPLY OUTLETS.PROVIDE OPPOSED BLADE,AS INDICATED ON THE DRAWINGS.SUB-BASE SWITCH, FURNISHED BY THE EQUIPMENTALL AIR CONDITIONING COMPRESSORS SHALLVOLTAGE HEAT-COOL THERMOSTATS WITH ON-OFF AUTOPROVIDE AIR CONDITIONING UNITS WITH MATCHING LOWPROVIDE SUPPLY AND RETURN GRILLES AND DIFFUSERSWARRANTED FOR A MINIMUM OF FIVE YEARS AFTER DATEPROVIDE EXTRUDED ALL ALUMINIUM AIR DISTRIBUTIONWITH THE CEILING TYPES AS SHOWN ON ARCHITECTURALFOR INSTALLATION, OPERATION AND SERVICE.PAYING SPECIAL ATTENTION TO REQUIREDAND BALANCE REPORT TO ARCHITECT / ENGINEER FORCAPACITIES. INDICATED ON DRAWINGS. SUBMIT FINALBALANCE ALL SYSTEMS TO PROVIDE AIR QUANTITIESINSTALL ALL EQUIPMENT IN ACCORDANCE TO THERECTANGULARPIPE3.13.2ACCEPTANCE.MANUFACTURER'SINSTALLATION2.7.43.02.7.22.7.12.7.3DRAWINGS.PRODUCTS.2.52.72.4MANUFACTURER.DAMPERSCOORDINATIONCLEARANCESMANUAL AND RECOMMENDATIONSKEYOFOPERATEDINMOUNT,ANDBEHVAC NOTESEXHAUST ROOF CAP DETAIL ntsBATHROOM, KITCHEN HOOD AND CLOTHS DRYER EXHAUST FANTYPICAL CEILING EXHAUST FAN DETAIL nts13.515.01500COOLINGTOTALRH1T4821STAN35.523.511.07/8"3/8"181 LBS50 1/2" x 21" x 21"35 3/8" x 31 5/8" x 31 5/8"RA1442BJ1150 LBSAHRI # 89534591ALUM FRAME ATTACHEDTO THE SIDE OF THE HOUSEDIAGONAL ALUM SUPPORTSEE SHT A-5 FOR DET'LSAND A.H.R.I. #8954591AIR HANDLER UNIT INSTALLATION DETAIL ntsFIN PLATFORM TO BE8'-0" NAVD FLOOD LEVELM-2 DATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. ST. LUCIE COUNTY FLORIDA 34996 6-18-21 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 160 NETTLES ISLAND BEDROOM # 3BEDROOM # 4MASTERBEDROOMBEDROOM # 2KITCHENMASTERBATHBATHLAUNDRYSTORAGESTAIRSSTAIRSW.I.CLOS.CLOS.W.I.CLOS.CLOS.OPEN TO FIRST FLOOR ROOFENTRYCLOS.BATHBATHFAMILY ROOMFOYERPLUMBING SECOND FLOOR PLAN 14"=1'-0"PLUMBING FIRST FLOOR PLAN 14"=1'-0"DATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA DON J. NUELLE , P.E. 34996 6-18-21 P.E. # 52046 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 382 NETTLES ISLANDP-1 PLUMBING NOTES- PROVIDE SHUT-OFF VALVE FOR EACH FIXTURE.- MATERIALS SHALL BE AS FOLLOWS: ALL PIPING THRU OUT HOUSE SHALL BE SCHEDULE 40 C.P.V.C. 3) STORM LINES INSIDE BUILDING SHALL BE C PVC SCHEDULE 40. 1) COLD WATER PIPING SCHEDULE 40 C. P.V.C. 2) SANITARY WASTE AND VENT 4" DIA. AND SMALLER SHALL BE C.PVC BUILDING SHALL BE PVC SCHEDULE 40. 4) IN COASTAL AREAS ALL SANITARY AND STORM PIPING OUTSIDE OF 5) CONDENSATE DRAIN PIPE SHALL BE C PVC SCHEDULE 40 PIPE AND FITTINGS. 6) WATER HEATER RELIEF AND DRAIN LINE SHALL BE C.P.V.C.STORM LINES OUTSIDE BUILDING SHALL BE C PVC SCHEDULE 80. 7) PROVIDE A DIRECT HOT WATER LINE FROM H.W.H. TO KITCHEN SINKWATER HEATER PIPING DIAGRAM ntsWATERHEATERPLUMBING RISER DIAGRAM NTSDATE OF SHEET REVISIONS A NEW RESIDENCE FOR MR. AND MRS WEIRSEMA STILTSVILLE 227 S.E. PELICAN DRIVE STUART FLORIDA TELEPHONE ; 772-221-1571 FAX# 772-678-6036 DON J. NUELLE , P.E. ST. LUCIE COUNTY FLORIDA 34996 6-18-21 P.E. # 52046 PH. # 561-629-6975 11634 S.W. ROWENA PORT ST LUCIE FL 34987LOT 160 NETTLES ISLANDP-2