HomeMy WebLinkAboutEnergy Efficiency Codeh ,
FORM R405-2020
FLORIDA ENERGY EFFICIENCY
CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
A t CA4z 1 S ch
co -
Project Name: OCEANSIDE RESDIENCE
Builder Name:
DST -Street: 4566 N A1A
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
10. Wall Types(3980.0 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 3980.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
4
d. N/A
R= ft2
5. Is this a worst case?
No
11. Ceiling Types (4370.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=23.0 4370.00 ft2
6. Conditioned floor area above grade (ft2)
4370
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
7. Windows(847.0 sqft.) Description
Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ft2
6 120
a. U-Factor: Sgl, U=0.42
847.00 ft2
b. Sup: Attic, Ret: Attic, AH: Attic
6 180
SHGC: SHGC=0.42
b. U-Factor: N/A
ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
24.0 SEER:16.00
c. U-Factor: N/A
ft2
b. Central Unit
46.5 SEER:16.00
SHGC:
Area Weighted Average Overhang Depth:
3.204 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.420
a. Electric Strip Heat
1.0 COP:1.00
7
b. Electric Strip Heat
34.0 COP:1.00
8. Skylights
Area
c. U-Factor:(AVG) N/A
ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric Tankless
Cap: 1 gallons
9. Floor Types (4370.0 sqft.)
Insulation Area
EF:0.990
a. Raised Floor
R=19.0 4370.00 ft2
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
16. Credits
None
Glass/Floor Area: 0.194
Total Proposed Modified Loads: 146.54
PASS
Total Baseline Loads: 149.36
I hereby certify that the plans and specifications covered by
this
Review of the plans and
OT'1 ST?A
calculation are in compliance with
the Florida Energy
specifications covered by this
O
Code.
calculation indicates compliance,'
d,-with
the Florida Energy Code.
�" nrgr'f%:-U.
PREPARED BY: -
DATE: 6-29-2021
Before construction is completed
this building will be inspected for'�r
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
,5..
with the Florida Energ de.
OWNER/AG
BUILDING OFFICIAL:
DATE.
�- �
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (11402.4.1.2).
- Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house.
6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1-of 8
FORM R40572020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
OCEANSIDE RESDIENCE
Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 4370
Lot #
Owner Name:
Total Stories: 2
Block/SubdhAsion:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
4566 N Al
Permit Office:
ST LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FORT PIERCE,
Family Type:
Detached
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
v Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
AHU 1
1463
14630
2
AHU 2
2907
30280
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
MASTER BEDROO
587
5870 No
0
1
1
Yes
Yes
Yes
2
M TOILET 1
48
480 No
0
1
Yes
Yes
Yes
3
M BATH
197
1970 No
0
1
Yes
Yes
Yes
4
M TOILET 2
40
400 No
0
1
Yes
Yes
Yes
5
M WIC 1
165
1650 No
0
1
Yes
Yes
Yes
6
M WIC 2
63
630 No
0
1
Yes
Yes
Yes
7
BEDROOM 2
237
2370 No
0
1
1
Yes
Yes
Yes
8
CLST 2
18
180 No
0
1
No
Yes
Yes
9
BATH 2
108
1080 No
0
1
Yes
Yes
Yes
10
STAIRS
90
900 No
0
1
Yes
Yes
Yes
11
ELEVATOR
25
250 No
0
1
No
Yes
Yes
12
PANTRY
46
460 No
0
1
Yes
Yes
Yes
13
LAUNDRY RM
70
700 No
0
1
No
Yes
Yes
14
KITCHEN/DINING
768
7680 Yes
0
1
Yes
Yes
Yes
15
BEDROOM 3
244
2440 No
0
1
1
Yes
Yes
Yes
16
CLST
22
220 No
0
1
No
Yes
Yes
17
BATH 3
100
1000 No
0
1
Yes
Yes
Yes
18
WIC 3
70
700 No
0
1
Yes
Yes
Yes
19
BATH 4
100
1000 No
0
1
Yes
Yes
Yes
20
WIC 4
70
700 No
0
1
Yes
Yes
Yes
21
BEDROOM 4
290
2900 No
0
1
1
Yes
Yes
Yes
6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
SPACES
Number Name
Area Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
22 HALL 3
94 940
No 0
1 No
Yes
Yes
23 FAMILY RM
605 7260
No 0
1 Yes
Yes
Yes
24 HALL 2
313 3130
No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Raised Floor
MASTER BEDRO
587 ft2
19
1
0
0
2 Raised Floor
M TOILET 1
48 ft2
19
1
0
0
3 Raised Floor
M BATH
____ ____
197 ft2
19
1
0
0
4 Raised Floor
M TOILET 2
____ ____
40 ft2
19
1
0
0
5 Raised Floor
M W IC 1
____ ___-
165 ft2
19
1
0
0
6 Raised Floor
M W IC 2
____ ____
63 ft2
19
1
0
0
7 Raised Floor
BEDROOM 2
237 ft2
19
1
0
0
8 Raised Floor
CLST 2
____ -___
18 ft2
19
1
0
0
9 Raised Floor
BATH 2
____ ___-
108 ft2
19
1
0
0
10Raised Floor
STAIRS
-_-_ ____
90 ft2
19
1
0
0
11Raised Floor
ELEVATOR
-__ ____
25 ft2
19
1
0
0
12Raised Floor
PANTRY
_-__ ____
46 ft2
19
1
0
0
13Raised Floor
LAUNDRY RM
70 ft2
19
1
0
0
14Raised Floor
KITCHEN/DININ
768 ft2
19
1
0
0
15Raised Floor
BEDROOM 3
-__-
244 ft2
19
1
0
0
16Raised Floor
CLST
____ ____
22 ft2
19
1
0
0
17Raised Floor
BATH 3
____ ____
100 ft2
19
1
0
0
18Raised Floor
WIC 3
70 ft2
19
1
0
0
19Raised Floor
BATH 4
___-
100 ft2
19
1
0
0
20Raised Floor
WIC 4
_-__
70 ft2
19
1
0
0
21Raised Floor
BEDROOM 4
290 ft2
19
1
0
0
22Raised Floor
HALL 3
____ ____
94 ft2
19
1
0
0
23Raised Floor
FAMILY RM
____ _---
605 ft2
19
1
0
0
24Raised Floor
HALL 2
313 ft2
19
1
0
0
6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 8
FORM R405-2020 INPUT SUMMARY CHECKLI5T REPORT
ROOF
V
Roof
Gable
Roof Rad
Solar
SA Emitt
Emitt Deck
Pitch
#
Type
Materials Area
Area
Color Barr
Absor.
Tested Tested Insul.
(deg)
1
Hip
Barrel tile 4886 ft2
0 ft2 Medium N
0.1
No 0.9
No 23
26.57
ATTIC
#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Unvented
0
4370 ft2
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented)
MASTER BEDRO
0
Blown
587 ft2
0.1
Wood
2
Under Attic (Unvented)
M TOILET 1
0
Blown
48 ft2
0.1
Wood
3
Under Attic (Unvented)
M BATH
0
Blown
197 ft2
0.1
Wood
4
Under Attic (Unvented)
M TOILET 2
0
Blown
40 ft2
0.1
Wood
5
Under Attic (Unvented)
M W IC 1
0
Blown
165 ft2
0.1
Wood
6
Under Attic (Unvented)
M W IC 2
0
Blown
63 ft2
0.1
Wood
7
Under Attic (Unvented)
BEDROOM 2
0
Blown
237 ft2
0.1
Wood
8
Under Attic (Unvented)
CLST 2
0
Blown
18 ft2
0.1
Wood
9
Under Attic (Unvented)
BATH 2
0
Blown
108 ft2
0.1
Wood
10
Under Attic (Unvented)
STAIRS
0
Blown
90 ft2
0.1
Wood
11
Under Attic (Unvented)
ELEVATOR
0
Blown
25 ft2
0.1
Wood
12
Under Attic (Unvented)
PANTRY
0
Blown
46 ft2
0.1
Wood
13
Under Attic (Unvented)
LAUNDRY RM
0
Blown
70 ft2
0.1
Wood
14
Under Attic (Unvented)
KITCHEN/DININ
0
Blown
768 ft2
0.1
Wood
15
Under Attic (Unvented)
BEDROOM 3
0
Blown
244 ft2
0.1
Wood
16
Under Attic (Unvented)
CLST
0
Blown
22 ft2
0.1
Wood
17
Under Attic (Unvented)
BATH 3
0
Blown
100 ft2
0.1
Wood
18
Under Attic (Unvented)
WIC 3
0
Blown
70 ft2
0.1
Wood
19
Under Attic (Unvented)
BATH 4
0
Blown
100 ft2
0.1
Wood
20
Under Attic (Unvented)
WIC 4
0
Blown
70 ft2
0.1
Wood
21
Under Attic (Unvented)
BEDROOM 4
0
Blown
290 ft2
0.1
Wood
22
Under Attic (Unvented)
HALL 3
0
Blown
94 ft2
0.1
Wood
23
Under Attic (Unvented)
FAMILY RM
0
Blown
605 ft2
0.1
Wood
24
Under Attic (Unvented)
HALL 2
0
Blown
313 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
SpaceAh.4znre
Et
ran
1 NE
Exterior Concrete Block - Int InsuMASTER BE
4.1 24
0 10 0
240.0 ft2
0 0
0.1
0
2 SE
Exterior Concrete Block - Int InsuMASTER BE
4.1 20
0 10 0
200.0 ft2
0 0
0.1
0
3 NW
Exterior Concrete Block - Int InsuMASTER BE
4.1 20
0 10 0
200.0 ft2
0 0
0.1
0
4 SW
Exterior Concrete Block - Int InsulM TOILET 1
4.1 6
0 10 0
60.0 ft2
0 0
0.1
0
5 NW
Exterior Concrete Block - Int InsulM TOILET 1
4.1 8
0 10 0
80.0 ft2
0 0
0.1
0
6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 8
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
6
SW
Exterior
Concrete Block - Int Insul M BATH
4.1
8
0
10
0
80.0 ft2
0
0
0.1
0
7
NW
Exterior
Concrete Block - Int Insul M BATH
4.1
7
0
10
0
70.0 ft2
0
0
0.1
0
8
SW
Exterior
Concrete Block - Int InsulM TOILET 2
4.1
5
0
10
0
50.0 ft2
0
0
0.1
0
9
NW
Exterior
Concrete Block- Int Insul M W IC 1
4.1
15
0
10
0
150.0 ft2
0
0
0.1
0
10
SE
Exterior
Concrete Block- Int Insul M W IC 2
4.1
6
0
10
0
60.0 ft2
0
0
0.1
0
11
SE
Exterior
Concrete Block- Int InsuBEDROOM 2
4.1
3
0
10
0
30.0 ft2
0
0
0.1
0
12
SW
Exterior
Concrete Block - Int InsuBEDROOM 2
4.1
13
0
10
0
130.0 ft2
0
0
0.1
0
13
NW
Exterior
Concrete Block - Int InsuBEDROOM 2
4.1
3
0
10
0
30.0 ft2
0
0
0.1
0
14
SW
Exterior
Concrete Block - Int Insul BATH 2
4.1
6
0
10
0
60.0 ft2
0
0
0.1
0
15
SE
Exterior
Concrete Block - Int Insul STAIRS
4.1
3
0
10
0
30.0 ft2
0
0
0.1
0
16
SW
Exterior
Concrete Block - Int Insul STAIRS
4.1
14
0
10
0
140.0 ft2
0
0
0.1
0
17
NW
Exterior
Concrete Block - Int Insul STAIRS
4.1
3
0
10
0
30.0 ft2
0
0
0.1
0
18
SW
Exterior
Concrete Block - Int Insul PANTRY
4.1
3
0
10
0
30.0 ft2
0
0
0.1
0
19
NE
Exterior
Concrete Block - Int InsuKITCHEN/DI
4.1
18
0
10
0
180.0 ft2
0
0
0.1
0
20
SW
Exterior
Concrete Block - Int InsuKITCHEN/DI
4.1
32
0
10
0
320.0 ft2
0
0
0.1
0
21
SW
Exterior
Concrete Block - Int InsuBEDROOM 3
4.1
15
0
10
0
150.0 ft2
0
0
0.1
0
22
SE
Exterior
Concrete Block- Int Insul BATH 3
4.1
10
0
10
0
100.0 ft2
0
0
0.1
0
23
SW
Exterior
Concrete Block - Int Insul BATH 3
4.1
10
0
10
0
100.0 ft2
0
0
0.1
0
24
SE
Exterior
Concrete Block- Int Insul WIC 3
4.1
7
0
10
0
70.0 ft2
0
0
0.1
0
25
SE
Exterior
Concrete Block - Int Insul BATH 4
4.1
10
0
10
0
100.0 ft2
0
0
0.1
0
26
SE
Exterior
Concrete Block- Int Insul WIC 4
4.1
7
0
10
0
70.0 ft2
0
0
0.1
0
27
NE
Exterior
Concrete Block - Int InsuBEDROOM 4
4.1
15
0
10
0
150.0 ft2
0
0
0.1
0
28
SE
Exterior
Concrete Block - Int InsuBEDROOM 4
4.1
16
0
10
0
160.0 ft2
0
0
0.1
0
29
NE
Exterior
Concrete Block - Int InsulFAMILY RM
4.1
24
0
12
0
288.0 ft2
0
0
0.1
0
30
NW
Exterior
Concrete Block - Int InsuIFAMILY RM
4.1
26
0
12
0
312.0 ft2
0
0
0.1
0
31
NE
Exterior
Concrete Block - Int Insul HALL 2
4.1
31
0
10
0
310.0 ft2
0
0
0.1
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Omt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
NE 1
Metal Low-E Single Yes
0.42
0.42
Y
16.0 ft2
2 ft 0 in
1 ft 4 in
None
None
2
NE 1
Metal Low-E Single Yes
0.42
0.42
Y
48.0 ft2
8 ft 0 in
1 ft 4 in
None
None
3
SE 2
Metal Low-E Single Yes
0.42
0.42
Y
96.0 ft2
2 ft 0 in
1 ft 4 in
None
None
4
SW 4
Metal Low-E Single Yes
0.42
0.42
Y
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
5
SW 6
Metal Low-E Single Yes
0.42
0.42
Y
16.0 ft2
2 ft 0 in
1 ft 4 in
None
None
6
SW 8
Metal Low-E Single Yes
0.42
0.42
Y
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
7
SW 12
Metal Low-E Single Yes
0.42
0.42
Y
30.0 ft2
8 ft 0 in
1 ft 4 in
None
None
8
SW 14
Metal Low-E Single Yes
0.42
0.42
Y
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
9
SW 16
Metal Low-E Single Yes
0.42
0.42
Y
6.0 ft2
2 ft 0 in
1 ft 4 in
None
None
10
SW 16
Metal Low-E Single Yes
0.42
0.42
Y
40.0 ft2
2 ft 0 in
1 ft 4 in
None
None
11
NE 19
Metal Low-E Single Yes
0.42
0.42
Y
96.0 ft2
2 ft 0 in
1 ft 4 in
None
None
12
SW 20
Metal Low-E Single Yes
0.42
0.42
Y
16.0 ft2
2 ft 0 in
1 ft 4 in
None
None
13
SW 20
Metal Low-E Single Yes
0.42
0.42
Y
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
14
SW
21
Metal
Low-E Single
Yes
0.42
0.42
Y
20.0 ft2
8 ft 0 in
1 ft 4 in
None
None
15
SW
21
Metal
Low-E Single
Yes
0.42
0.42
Y
24.0 ft2
8 ft 0 in
1 ft 4 in
None
None
16
SE
22
Metal
Low-E Single
Yes
0.42
0.42
Y
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
17
SW
23
Metal
Low-E Single
Yes
0.42
0.42
Y
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
18
SE
25
Metal
Low-E Single
Yes
0.42
0.42
Y
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
19
NE
27
Metal
Low-E Single
Yes
0.42
0.42
Y
48.0 ft2
8 ft 0 in
1 ft 4 in
None
None
20
SE
28
Metal
Low-E Single
Yes
0.42
0.42
Y
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
21
NE
29
Metal
Low-E Single
Yes
0.42
0.42
Y
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
22
NE
29
Metal
Low-E Single
Yes
0.42
0.42
Y
16.0 ft2
2 ft 0 in
1 ft 4 in
None
None
23
NE
29
Metal
Low-E Single
Yes
0.42
0.42
Y
30.0 ft2
2 ft 0 in
1 ft 4 in
None
None
24
NW
30
Metal
Low-E Single
Yes
0.42
0.42
Y
128.0 ft2
2 ft 0 in
1 ft 4 in
None
None
25
NE
31
Metal
Low-E Single
Yes
0.42
0.42
Y
8.0 ft2
2 ft 0 in
1 ft 4 in
None
None
26
NE
31
Metal
Low-E Single
Yes
0.42
0.42
Y
96.0 ft2
2 ft 0 in
1 ft 4 in
None
None
INFILTRATION
# Scope
Method
SLA
CFM 50
ELA
EgLA
ACH
ACH 50
1 Wholehouse
ProposedACH(50)
.000326
3742.5
205.32
385.47
.1316
5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1
2
Electric Strip Heat/
Electric Strip Heat/
None
None
COPA 17 kBtu/hr
COP:1 34 kBtu/hr
1
2
sys#1
sys#2
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
2
Central Unit/
Central Unit/
Split
Split
Single SEER: 16 24 kBtu/hr 720 cfm
Single SEER: 16 46.5 kBtu/hr 1395 cfm
0.8 1
0.8 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt
Conservation
1
2
Electric Tankless
Electric Tankless
MASTER BEDR09M 1 gal 55.1 gal 120 deg
WIC 3 0.99 1 gal 55.1 gal 120 deg
None
None
6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 8
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
— Supply--
v
— Return —
Air
CFM 25
CFM25
HVAC #
# Location R-Value
Area Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat
Cool
1 Attic
6
120 ft2 Attic
12 ft2
Prop. Leak Free
Attic
— cfm
43.9 cfm 0.03
0.50
1
1
2 Attic
6
180 ft2 Attic
18 ft2
Prop. Leak Free
Attic
— cfm
87.2 cfm 0.03
0.50
2
2
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Cooling Jan Feb
ti Jan H
Mar Apr
Mar
May
Jun 1 Jul
Jun f ] Jul
Auge
f Aug
Sep
Oct
t
OctX
Nov
Nov
Dec
Dec
Venting Feb
Mar Ab pr
May
Jun [ ]Jul
[ Aug
Sep
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (W D) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
80
80
78 78
78
78
78 78
78
78
Cooling (W EH) AM
78
78
78
78
78 78
78
78
80 80
80
80
PM
80
80
80
80
78 78
78
78
78 78
78
78
Heating (W D) AM
65
65
65
65
65 65
65
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68
68
Heating (WEH) AM
65
65
65
65
65 65
65
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M TOILET 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M W IC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
STAIRS
Default(8 Ibs/sq.ft.
ft2
ft
0.3
ELEVATOR
Default(8 Ibs/sq.ft.
ft2
ft
0.3
PANTRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY RM
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN/DINING
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 4
6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 8
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALL 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
FAMILY RM
Default(8 Ibs/s .ft.
ft2
ft
0.3
HALL 2
6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 8 of 8