Loading...
HomeMy WebLinkAboutEnergy Efficiency Codeh , FORM R405-2020 FLORIDA ENERGY EFFICIENCY CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method A t CA4z 1 S ch co - Project Name: OCEANSIDE RESDIENCE Builder Name: DST -Street: 4566 N A1A Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Types(3980.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 3980.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (4370.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=23.0 4370.00 ft2 6. Conditioned floor area above grade (ft2) 4370 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(847.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 120 a. U-Factor: Sgl, U=0.42 847.00 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 180 SHGC: SHGC=0.42 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 24.0 SEER:16.00 c. U-Factor: N/A ft2 b. Central Unit 46.5 SEER:16.00 SHGC: Area Weighted Average Overhang Depth: 3.204 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.420 a. Electric Strip Heat 1.0 COP:1.00 7 b. Electric Strip Heat 34.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Tankless Cap: 1 gallons 9. Floor Types (4370.0 sqft.) Insulation Area EF:0.990 a. Raised Floor R=19.0 4370.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.194 Total Proposed Modified Loads: 146.54 PASS Total Baseline Loads: 149.36 I hereby certify that the plans and specifications covered by this Review of the plans and OT'1 ST?A calculation are in compliance with the Florida Energy specifications covered by this O Code. calculation indicates compliance,' d,-with the Florida Energy Code. �" nrgr'f%:-U. PREPARED BY: - DATE: 6-29-2021 Before construction is completed this building will be inspected for'�r compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. ,5.. with the Florida Energ de. OWNER/AG BUILDING OFFICIAL: DATE. �- � DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (11402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 On for whole house. 6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1-of 8 FORM R40572020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: OCEANSIDE RESDIENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 4370 Lot # Owner Name: Total Stories: 2 Block/SubdhAsion: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 4566 N Al Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 1463 14630 2 AHU 2 2907 30280 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 587 5870 No 0 1 1 Yes Yes Yes 2 M TOILET 1 48 480 No 0 1 Yes Yes Yes 3 M BATH 197 1970 No 0 1 Yes Yes Yes 4 M TOILET 2 40 400 No 0 1 Yes Yes Yes 5 M WIC 1 165 1650 No 0 1 Yes Yes Yes 6 M WIC 2 63 630 No 0 1 Yes Yes Yes 7 BEDROOM 2 237 2370 No 0 1 1 Yes Yes Yes 8 CLST 2 18 180 No 0 1 No Yes Yes 9 BATH 2 108 1080 No 0 1 Yes Yes Yes 10 STAIRS 90 900 No 0 1 Yes Yes Yes 11 ELEVATOR 25 250 No 0 1 No Yes Yes 12 PANTRY 46 460 No 0 1 Yes Yes Yes 13 LAUNDRY RM 70 700 No 0 1 No Yes Yes 14 KITCHEN/DINING 768 7680 Yes 0 1 Yes Yes Yes 15 BEDROOM 3 244 2440 No 0 1 1 Yes Yes Yes 16 CLST 22 220 No 0 1 No Yes Yes 17 BATH 3 100 1000 No 0 1 Yes Yes Yes 18 WIC 3 70 700 No 0 1 Yes Yes Yes 19 BATH 4 100 1000 No 0 1 Yes Yes Yes 20 WIC 4 70 700 No 0 1 Yes Yes Yes 21 BEDROOM 4 290 2900 No 0 1 1 Yes Yes Yes 6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 22 HALL 3 94 940 No 0 1 No Yes Yes 23 FAMILY RM 605 7260 No 0 1 Yes Yes Yes 24 HALL 2 313 3130 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor MASTER BEDRO 587 ft2 19 1 0 0 2 Raised Floor M TOILET 1 48 ft2 19 1 0 0 3 Raised Floor M BATH ____ ____ 197 ft2 19 1 0 0 4 Raised Floor M TOILET 2 ____ ____ 40 ft2 19 1 0 0 5 Raised Floor M W IC 1 ____ ___- 165 ft2 19 1 0 0 6 Raised Floor M W IC 2 ____ ____ 63 ft2 19 1 0 0 7 Raised Floor BEDROOM 2 237 ft2 19 1 0 0 8 Raised Floor CLST 2 ____ -___ 18 ft2 19 1 0 0 9 Raised Floor BATH 2 ____ ___- 108 ft2 19 1 0 0 10Raised Floor STAIRS -_-_ ____ 90 ft2 19 1 0 0 11Raised Floor ELEVATOR -__ ____ 25 ft2 19 1 0 0 12Raised Floor PANTRY _-__ ____ 46 ft2 19 1 0 0 13Raised Floor LAUNDRY RM 70 ft2 19 1 0 0 14Raised Floor KITCHEN/DININ 768 ft2 19 1 0 0 15Raised Floor BEDROOM 3 -__- 244 ft2 19 1 0 0 16Raised Floor CLST ____ ____ 22 ft2 19 1 0 0 17Raised Floor BATH 3 ____ ____ 100 ft2 19 1 0 0 18Raised Floor WIC 3 70 ft2 19 1 0 0 19Raised Floor BATH 4 ___- 100 ft2 19 1 0 0 20Raised Floor WIC 4 _-__ 70 ft2 19 1 0 0 21Raised Floor BEDROOM 4 290 ft2 19 1 0 0 22Raised Floor HALL 3 ____ ____ 94 ft2 19 1 0 0 23Raised Floor FAMILY RM ____ _--- 605 ft2 19 1 0 0 24Raised Floor HALL 2 313 ft2 19 1 0 0 6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 8 FORM R405-2020 INPUT SUMMARY CHECKLI5T REPORT ROOF V Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 4886 ft2 0 ft2 Medium N 0.1 No 0.9 No 23 26.57 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 4370 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MASTER BEDRO 0 Blown 587 ft2 0.1 Wood 2 Under Attic (Unvented) M TOILET 1 0 Blown 48 ft2 0.1 Wood 3 Under Attic (Unvented) M BATH 0 Blown 197 ft2 0.1 Wood 4 Under Attic (Unvented) M TOILET 2 0 Blown 40 ft2 0.1 Wood 5 Under Attic (Unvented) M W IC 1 0 Blown 165 ft2 0.1 Wood 6 Under Attic (Unvented) M W IC 2 0 Blown 63 ft2 0.1 Wood 7 Under Attic (Unvented) BEDROOM 2 0 Blown 237 ft2 0.1 Wood 8 Under Attic (Unvented) CLST 2 0 Blown 18 ft2 0.1 Wood 9 Under Attic (Unvented) BATH 2 0 Blown 108 ft2 0.1 Wood 10 Under Attic (Unvented) STAIRS 0 Blown 90 ft2 0.1 Wood 11 Under Attic (Unvented) ELEVATOR 0 Blown 25 ft2 0.1 Wood 12 Under Attic (Unvented) PANTRY 0 Blown 46 ft2 0.1 Wood 13 Under Attic (Unvented) LAUNDRY RM 0 Blown 70 ft2 0.1 Wood 14 Under Attic (Unvented) KITCHEN/DININ 0 Blown 768 ft2 0.1 Wood 15 Under Attic (Unvented) BEDROOM 3 0 Blown 244 ft2 0.1 Wood 16 Under Attic (Unvented) CLST 0 Blown 22 ft2 0.1 Wood 17 Under Attic (Unvented) BATH 3 0 Blown 100 ft2 0.1 Wood 18 Under Attic (Unvented) WIC 3 0 Blown 70 ft2 0.1 Wood 19 Under Attic (Unvented) BATH 4 0 Blown 100 ft2 0.1 Wood 20 Under Attic (Unvented) WIC 4 0 Blown 70 ft2 0.1 Wood 21 Under Attic (Unvented) BEDROOM 4 0 Blown 290 ft2 0.1 Wood 22 Under Attic (Unvented) HALL 3 0 Blown 94 ft2 0.1 Wood 23 Under Attic (Unvented) FAMILY RM 0 Blown 605 ft2 0.1 Wood 24 Under Attic (Unvented) HALL 2 0 Blown 313 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below SpaceAh.4znre Et ran 1 NE Exterior Concrete Block - Int InsuMASTER BE 4.1 24 0 10 0 240.0 ft2 0 0 0.1 0 2 SE Exterior Concrete Block - Int InsuMASTER BE 4.1 20 0 10 0 200.0 ft2 0 0 0.1 0 3 NW Exterior Concrete Block - Int InsuMASTER BE 4.1 20 0 10 0 200.0 ft2 0 0 0.1 0 4 SW Exterior Concrete Block - Int InsulM TOILET 1 4.1 6 0 10 0 60.0 ft2 0 0 0.1 0 5 NW Exterior Concrete Block - Int InsulM TOILET 1 4.1 8 0 10 0 80.0 ft2 0 0 0.1 0 6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 6 SW Exterior Concrete Block - Int Insul M BATH 4.1 8 0 10 0 80.0 ft2 0 0 0.1 0 7 NW Exterior Concrete Block - Int Insul M BATH 4.1 7 0 10 0 70.0 ft2 0 0 0.1 0 8 SW Exterior Concrete Block - Int InsulM TOILET 2 4.1 5 0 10 0 50.0 ft2 0 0 0.1 0 9 NW Exterior Concrete Block- Int Insul M W IC 1 4.1 15 0 10 0 150.0 ft2 0 0 0.1 0 10 SE Exterior Concrete Block- Int Insul M W IC 2 4.1 6 0 10 0 60.0 ft2 0 0 0.1 0 11 SE Exterior Concrete Block- Int InsuBEDROOM 2 4.1 3 0 10 0 30.0 ft2 0 0 0.1 0 12 SW Exterior Concrete Block - Int InsuBEDROOM 2 4.1 13 0 10 0 130.0 ft2 0 0 0.1 0 13 NW Exterior Concrete Block - Int InsuBEDROOM 2 4.1 3 0 10 0 30.0 ft2 0 0 0.1 0 14 SW Exterior Concrete Block - Int Insul BATH 2 4.1 6 0 10 0 60.0 ft2 0 0 0.1 0 15 SE Exterior Concrete Block - Int Insul STAIRS 4.1 3 0 10 0 30.0 ft2 0 0 0.1 0 16 SW Exterior Concrete Block - Int Insul STAIRS 4.1 14 0 10 0 140.0 ft2 0 0 0.1 0 17 NW Exterior Concrete Block - Int Insul STAIRS 4.1 3 0 10 0 30.0 ft2 0 0 0.1 0 18 SW Exterior Concrete Block - Int Insul PANTRY 4.1 3 0 10 0 30.0 ft2 0 0 0.1 0 19 NE Exterior Concrete Block - Int InsuKITCHEN/DI 4.1 18 0 10 0 180.0 ft2 0 0 0.1 0 20 SW Exterior Concrete Block - Int InsuKITCHEN/DI 4.1 32 0 10 0 320.0 ft2 0 0 0.1 0 21 SW Exterior Concrete Block - Int InsuBEDROOM 3 4.1 15 0 10 0 150.0 ft2 0 0 0.1 0 22 SE Exterior Concrete Block- Int Insul BATH 3 4.1 10 0 10 0 100.0 ft2 0 0 0.1 0 23 SW Exterior Concrete Block - Int Insul BATH 3 4.1 10 0 10 0 100.0 ft2 0 0 0.1 0 24 SE Exterior Concrete Block- Int Insul WIC 3 4.1 7 0 10 0 70.0 ft2 0 0 0.1 0 25 SE Exterior Concrete Block - Int Insul BATH 4 4.1 10 0 10 0 100.0 ft2 0 0 0.1 0 26 SE Exterior Concrete Block- Int Insul WIC 4 4.1 7 0 10 0 70.0 ft2 0 0 0.1 0 27 NE Exterior Concrete Block - Int InsuBEDROOM 4 4.1 15 0 10 0 150.0 ft2 0 0 0.1 0 28 SE Exterior Concrete Block - Int InsuBEDROOM 4 4.1 16 0 10 0 160.0 ft2 0 0 0.1 0 29 NE Exterior Concrete Block - Int InsulFAMILY RM 4.1 24 0 12 0 288.0 ft2 0 0 0.1 0 30 NW Exterior Concrete Block - Int InsuIFAMILY RM 4.1 26 0 12 0 312.0 ft2 0 0 0.1 0 31 NE Exterior Concrete Block - Int Insul HALL 2 4.1 31 0 10 0 310.0 ft2 0 0 0.1 0 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 1 Metal Low-E Single Yes 0.42 0.42 Y 16.0 ft2 2 ft 0 in 1 ft 4 in None None 2 NE 1 Metal Low-E Single Yes 0.42 0.42 Y 48.0 ft2 8 ft 0 in 1 ft 4 in None None 3 SE 2 Metal Low-E Single Yes 0.42 0.42 Y 96.0 ft2 2 ft 0 in 1 ft 4 in None None 4 SW 4 Metal Low-E Single Yes 0.42 0.42 Y 8.0 ft2 2 ft 0 in 1 ft 4 in None None 5 SW 6 Metal Low-E Single Yes 0.42 0.42 Y 16.0 ft2 2 ft 0 in 1 ft 4 in None None 6 SW 8 Metal Low-E Single Yes 0.42 0.42 Y 8.0 ft2 2 ft 0 in 1 ft 4 in None None 7 SW 12 Metal Low-E Single Yes 0.42 0.42 Y 30.0 ft2 8 ft 0 in 1 ft 4 in None None 8 SW 14 Metal Low-E Single Yes 0.42 0.42 Y 8.0 ft2 2 ft 0 in 1 ft 4 in None None 9 SW 16 Metal Low-E Single Yes 0.42 0.42 Y 6.0 ft2 2 ft 0 in 1 ft 4 in None None 10 SW 16 Metal Low-E Single Yes 0.42 0.42 Y 40.0 ft2 2 ft 0 in 1 ft 4 in None None 11 NE 19 Metal Low-E Single Yes 0.42 0.42 Y 96.0 ft2 2 ft 0 in 1 ft 4 in None None 12 SW 20 Metal Low-E Single Yes 0.42 0.42 Y 16.0 ft2 2 ft 0 in 1 ft 4 in None None 13 SW 20 Metal Low-E Single Yes 0.42 0.42 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 14 SW 21 Metal Low-E Single Yes 0.42 0.42 Y 20.0 ft2 8 ft 0 in 1 ft 4 in None None 15 SW 21 Metal Low-E Single Yes 0.42 0.42 Y 24.0 ft2 8 ft 0 in 1 ft 4 in None None 16 SE 22 Metal Low-E Single Yes 0.42 0.42 Y 8.0 ft2 2 ft 0 in 1 ft 4 in None None 17 SW 23 Metal Low-E Single Yes 0.42 0.42 Y 8.0 ft2 2 ft 0 in 1 ft 4 in None None 18 SE 25 Metal Low-E Single Yes 0.42 0.42 Y 8.0 ft2 2 ft 0 in 1 ft 4 in None None 19 NE 27 Metal Low-E Single Yes 0.42 0.42 Y 48.0 ft2 8 ft 0 in 1 ft 4 in None None 20 SE 28 Metal Low-E Single Yes 0.42 0.42 Y 20.0 ft2 2 ft 0 in 1 ft 4 in None None 21 NE 29 Metal Low-E Single Yes 0.42 0.42 Y 15.0 ft2 2 ft 0 in 1 ft 4 in None None 22 NE 29 Metal Low-E Single Yes 0.42 0.42 Y 16.0 ft2 2 ft 0 in 1 ft 4 in None None 23 NE 29 Metal Low-E Single Yes 0.42 0.42 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 24 NW 30 Metal Low-E Single Yes 0.42 0.42 Y 128.0 ft2 2 ft 0 in 1 ft 4 in None None 25 NE 31 Metal Low-E Single Yes 0.42 0.42 Y 8.0 ft2 2 ft 0 in 1 ft 4 in None None 26 NE 31 Metal Low-E Single Yes 0.42 0.42 Y 96.0 ft2 2 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000326 3742.5 205.32 385.47 .1316 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ Electric Strip Heat/ None None COPA 17 kBtu/hr COP:1 34 kBtu/hr 1 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Central Unit/ Split Split Single SEER: 16 24 kBtu/hr 720 cfm Single SEER: 16 46.5 kBtu/hr 1395 cfm 0.8 1 0.8 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 2 Electric Tankless Electric Tankless MASTER BEDR09M 1 gal 55.1 gal 120 deg WIC 3 0.99 1 gal 55.1 gal 120 deg None None 6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply-- v — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 120 ft2 Attic 12 ft2 Prop. Leak Free Attic — cfm 43.9 cfm 0.03 0.50 1 1 2 Attic 6 180 ft2 Attic 18 ft2 Prop. Leak Free Attic — cfm 87.2 cfm 0.03 0.50 2 2 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan Feb ti Jan H Mar Apr Mar May Jun 1 Jul Jun f ] Jul Auge f Aug Sep Oct t OctX Nov Nov Dec Dec Venting Feb Mar Ab pr May Jun [ ]Jul [ Aug Sep Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 Ibs/sq.ft. ft2 ft 0.3 M TOILET 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 STAIRS Default(8 Ibs/sq.ft. ft2 ft 0.3 ELEVATOR Default(8 Ibs/sq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY RM Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN/DINING Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 4 6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 8 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 FAMILY RM Default(8 Ibs/s .ft. ft2 ft 0.3 HALL 2 6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 8 of 8