HomeMy WebLinkAboutEnergy Performance Display CardFORM R405-2020
JUL V ?1
ST.
ENERGY PERFORMANCE LEVEL (EPL) DIS
ESTIMATED ENERGY PERFORMANCE INDEX' = 98
The lower the EnergyPerformance Index, the more efficient the home.
4566 N A1A, FORT PIERCE, FL,
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
3980.00 ft2
b. NA
R=
ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Roof Deck (Unvented)
R=23.0
4370.00 ft2
6. Conditioned floor area (W)
4370
b. N/A
R=
ft2
7. Windows" Description
Area
_
R
z
t2
a. U-Factor: Sgl, U=0.42
847.00 ft2
.
12Ducts, location &insulation level
R
a. Sup: Attic, Ret: Attic, AH: Attic
6 120
SHGC: SHGC=0.42
b. Sup: Attic, Ret: Attic, AH: Attic
6 180
b. U-Factor: N/A
ft2
SHGC:
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
24.0 SEER:16.00
SHGC:
b. Central Unit
46.5 SEER:16.00
d. U-Factor: N/A
ft2
SHGC:
14. Heating systems
kBtu/hr
Efficiency
a. Electric Strip Heat
17.0
COP:1.00
Area Weighted Average Overhang Depth:
3.204 ft.
b. Electric Strip Heat
34.0
COP:1.00
Area Weighted Average SHGC:
0.420
8. Skylights Description
Area
15. Hot water systems
Cap:
1 gallons
a. U-Factor(AVG): N/A
ft2
a. Electric
EF:0.99
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Raised Floor
R=19.0
4370.00 ftz
Credits (Performance method)
None
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date: -1'Le I a� -2 1
Address of New Home: "AST(et'.Q n Ir 14
City/FL Zip: -9� RAN,-R al.
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/29/2021 4:14 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1