Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Efficiency Code
Project.Name: WYNNE-THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT - Street: THE:STERLING Permit Office: :ST. LUCIE:000NTY ' City, State; Zip:. FT.:PIERCE , FL, Permit Number:. Owner: Jurisdiction: -Design Location:. FL, FortPierce Courity: St. Lucie (Florida Climate Zone 2) . 1.. New constructionorexisting. New(From.Plans), .:.. 9. Wall-Types(1442.0':sgft:) Insulation ...Area.• .. 2. Single family or multiple family- Single-family a.'Concrete Block -..Int Insul, Exterior. R=4.1 1250.00 ft2 .: b..Frame - Wood, Adjacent - R=11.0 .192.00 ft= . 3. • Number of units, if multiple family. 1 c. N/A R= ft2 4. Number of Bedrooms : 2: d N/A R= : ft2 5: Is this a worst, case? Yes 10..Ceiling. Types.(1504.0 sqft.) Insulation • :.Area.- - .. a. Under Attic (Vented) R=30.0. 1474.00 ft2 . 6. Conditioned floor area above grade (ft2) 1474 b.,Knee. Wall (Vented) .=R=19.0 30.0.0 ft2. _ Conditioned floor area below (ft2) 0 c. N/A R= ft2 -grade . .. .. 1.1. Ducts - .. . R .. ft2.. . . 7: Windows(141:3 sgft:) Description Area a: Sup: Attic, Ret: Attic, AH: Attic 6 175 . a. -U=Factor: Sgl, U=1:04 . 101.25 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2. 12. Cooling systems kBtu/hr ' Efficiency .. SHGC:. SHGC=0.27 a. Central Unit 34.8 .SEER: 15:00. c. U-Factor:. N/A ... ft2. :SHGC; : 13. Heating systems kBtu/hr . :Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump. 34.8. HSPF:8.50:. SHGC: Area Weighted Average -Overhang Depth: 3:832 ft.. - Area Weighted Average SHGC: 0.284 . • -14. Hot.water systems :. . a. Electric Cap: 40.gallons. 8. Floor Types (1473.5 .sgft.) Insulation . Area EF: 0.970 .a. Slab -On -Grade Ede Insulation R=0.0 1473:50 ft2' 9 b. Conservation'features ' b. N/A.: :R= ft2 .. .None , c. N/A.: -R - ft2. ... .. .. .15. Credits Pstat . Total Proposed, Modified Loads: 47.97 . Glass/Floor Area: ' 0.096 ' PASS Total Baseline Loads: 48.55 hereby certify that the plans and -specifications covered by Review of the plans and -this calculation are in compliance with the -Florida Energy specifications covered by this Code. calculation indicatescompliance with the Florida Energy Code.: FRE )ARED�BY: DATE: 1-9-20 . ' Before construction is oompleted this building will be inspected for compliance with Section 553.908. �' I �'- - A� hereby certify -that this building, as designed, is in compliance -Florida Statutes. with the Florida Energy. Code. ... ���. .. bwNER/AKENTX.BUILDING OFFICIAL: DAT DATE:. Compliance requires certification by the air handler unit manufacturer that tL111ftpVipfAies as certified factory -sealed in accordance with R403:3:2.1. Compliance requires an.Air Barrier and Insulation Inspection Checklist.i� 1 13i roject requires an envelope.leakage test report with envelope leakage no greater than 7.00 A ( ��_ UNT .... . ' sock 1/8/2020 4:48 PM � � EnergyGauge® USA 6.0.02. (Rev. 1) - FlaRes2017 FBC. 6th Edition. (2017) Compliant Software Page 1 of 5. FORM R405-2017 INPUT. SUMMARY' CHECKLIST REPORT PROJECT `r Title: WYNNE THE STERLING IMP Bedrooms-. 2 Address Type: Street Address : -Building Type: User Conditioned Area: 1474 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle:. 180 Street: THE STERLING . Permit Office: ST. LUCIE COUNT_ Y Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No - City, State, Zip:. FT, PIERCE.; . Family Type: Single-family: FL New/Existing: New (From Plans) Comment:. CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2:5 %o Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH _MUNI 39 90 70 75 299 62- tow BLOCKS Number- Name 'Area. :Volume .1 Entire House 1474 11792 SPACES .Number Name Area Volume Kitchen .Occupants. Bedrooms: Infil ID Finished - Cooled . Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes ' 2: WIC : " 63 504 No 0 1 No. Yes : ' Yes 3 M.BATH 56 448 No 0 1 Yes Yes " Yes 4 KITCHEN 192 1536 Yes 0 1 No . Yes Yes' 5. BATH. 45 360 No 0 1 Yes- Yes.. Yes 6 . BEDROOM 2 204 1632 No 0 1 1 Yes : Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 -Yes Yes Yes 9 GREAT/DINING. 488 3904 No 0 1_ Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile, Wood Carpet 1 Slab -On -Grade Edge Insulatio .BEDROOM 52 ft 0 329 ft2 '0 1 0 . 2.Slab-On-Grade Edge Insulatio WIC 1 ft -0 63 ft2 ____ 0- 1 0 3 Slab -On -Grade Edge Insulatio M. BATH .8 ft 0 56 ft2 0 1 0 4Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 192ft2 ____ 0 1 0 .5-Slab-On-Grade Edge. Insulatio BATH 5 ft 0 45 ft2 _ _ 0 1. 0 .6 Slab -On -Grade Edge Insulatio BEDROOM-2. 32.2 ft 0 203.5 ft2 0. 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 0 1 0. . .... . 1/8/2020 4:48 PM EnergyGaugeO USA 6.0.02:(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5. 0 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS . # Floor Type Space Perimeter Perimeter R-Value Area' Joist R-Value -Tile Wood Carpet: 8 Slab -On -Grade Edge_ Insulatio LAUNDRY 6 ft : 0 .42 ft2 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 0 1 0 ROOF_. Roof Gable Roof Rad Solar. SA Emitt Emitt ,Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested 'Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft2 246 ft2 Light N 0.6 No 0.9 . No 0 18.4 ATTIC. -(I ' V # Type Ventilation: Vent Ratio in) Area RBS IRCC. 1 Full attic Vented 150 1474 ft2' - N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft2 0.1 _ Wood; 2 Under Attic (Vented) WIC 30 Blown 63.ft2 0.1 Wood - 3 Under Attic (Vented) M.-BATH 30 Blown 56V 0.1 Wood 4 Under Attic (Vented) KITCHEN ' 30 Blown 192 ft2 0.1 Wood .5 Under Attic (Vented) BATH 30 Blown 45 ft2 .0.1 Wood 6 . Under Attic (Vented) BEDROOM 2 30 Blown. 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55:ft2 0.1 Wood 8. Under Attic (Vented) LAUNDRY 30 Blown .42 ft2. 0.1. Wood. 9 Under Attic (Vented) GREAT/DINING 30 Blown .488 ft2 '0.1 Wood 10. Knee Wall (Vented) BEDROOM 19 Blown 30 ft2 0.11. Wood WALLS Adjacent Space Cavity WidthPA/alue Et In Height Sheathing Fram;Icting Solar Below _To 1 NE=>SW Exterior Concrete Block - Int InsuBEDROOM.. 4.1 10 0. 8 0 80.0 ft2, 0 -: 0 0.4 0 2 SW=>NE Exterior :Concrete Block - Int InsLBEDROOM 4.1 28 0 8 0 224.0 ft2 0 0: 0.4 0 3 NW=>SE Exterior . Concrete Block = Int InsuBEDROOM 4.1 14 0 8- 0 112.0 ft2 0 '0 0.4 0' 4. SW=>NE. Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 . 8 0 64.0 ft2. .0 .- 0 OA 0 5 NE=>SW ,Exterior Concrete Block - Int Insul BATH 4.1 5 0 8 0 40.0 ft2' 0 0 0.4 0 6 ' NE=>SW Exterior Concrete Block - Int InsI3EDROOM 2 4.1 16 0 8 0- 128.0 ft2 0 0 0.4 -0 7. SE=>NW.Exterior. Concrete Block - Int InsBEDROOM 2 -4.1 10 0 8. 0 80.0 ft2 0 0. 6.4 0 8 S=>N Exterior Concrete Block- Int InsENEDROOM 2 4.1 4 3 8 0 -34.0 ft2 0 0 -0.4 0 9 SW=>NE Exterior Concrete Block - Int InsBIEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block - Int Insul ENTRY 4.1 6 0 8:. 0 : 48.0 ft2 0 0 0.4 0 11 SW=>NE Exterior Concrete Block - Int Insul ENTRY 4.1 V 0 8 0 8.0 ft2 0 0 0.4 0 12 SW=>NE Exterior Concrete Block - Int.InsuLAUNDRY 4.1 6 0 8 0 48.0 ft2 0 .0 0.4 0 13 NE=>SW Exterior Concrete Block - Int InsLOREAT/DINI 4.1 26 0 8 0 208.0 ft2 0- 0 0.4 •0 14 NW=>SE Exterior Concrete Block - Int InsLOREAT/DINI 4.1 20 0 8 0 160.0 ft2 0. -0 . 0.4 0 1/8/2020 4:48 PM . EnergyGauge® USA 6.0.02;(Rev..1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software; Page 3 of 5; FORM R405-2Q17 INPUT. SUMMARY: CHECKLIST REPORT - �. WALLS . . . . . . . . . . . . Adjacent Cavity Width Height Sheathing' Framing : Solar Below Spacerea Ahqor,Grade% 15 - N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft'-: 0.23 0.4 0- DOORS # Omt Door Type Space. Storms . U-Value Width Height ;' Ft In Ft. In. .Area 1 SE=>NW- Insulated' ENTRY - 'None . .39., 3 -• 1 6 -. 8 20.6 ft' WINDOWS. Orientation shown is the''entered orientation. _> chars ed to Worst Case.. / Wall. V # Ornt ID. Frame Panes: Overhang NFRC U-Factor: SHGC Imp. Area Depth Separation Int:Shade Screening: 1 ',NW=>SE 3 :Metal _•Low-E 2. SW=>NEA Metal .3 SE=>NW-7 Metal- 4 NE=>SW13.. Metal '5.:NW=>SE14.•. Metal. Single Low-E Single Low-E Single Low E Single. 'Low-E Single Yes :1.04 :0.29 N 32.9.ft2: 1 ft 0 in .1 ft 5 in; -.' Drapes/blinds Yes .1.04 0.29 N 6.9 ft'. 1 ft 0 in,- 1 ft 5. in None Yes 1.04 - 0:29. N - . 24..0 ft' 6 ft.0 in'- 1 ft 5. in ' None Yes 1.04 -0.29- :N 37.'5:ft' 1 ft 0 in 1 ft 5 in: None Yes 1.11 'U7 N : . 40.0 it? : 8 ft 0 in ..Aft5 in .:.Drapes/blinds .. Exterior 5 None - . None None Exterior 5 . GARAGE # - Floor.Area Ceiling Area Exposed Wall -Perimeter Avg. Wall Height : Exposed .Wall Insulation 1 315 ft'. 31512 24 ft 8 ft 11 INFILTRATION # Scope Method . . .SLA CFM 50 ELA EgLA ACH ACH 50 .. 1 , Wholehouse Proposed'ACH(50) .000356 • 1375.7 75.53 142.04 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity. .Block Ducts 1:, Electric.Heaf Pump/ Split Singl HSPF:8:5 34.8 kBtu/hr 1:- sys#1 COOLING SYSTEM # System Type Subtype. Subtype Efficiency Capacity Air Flow •SHR Block Ducts 1 CentralUnitU Split: Sing!. SEER:15 34.8-kBtu/hr cfm 0.851. 1 sys#1 HOT-WATER SYSTEM # System Type Sub Location EF Cap Use $etPnt Conservation: :1Electric : None : Garage 0.97 40 gal 60.9 gal 120 deg None FORM R405-2017 INPUT. SUMMARY: CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEG Collector Storage. Cert # . Company Name System Model #. Collector Model # . Area Volume. . FEF.- None None DUCTS . . / — Supply -- —= Return - - Air CFM 25 - CFM25: HVAC # V # . Location RWalue Area Location Area . Leakage Type Handler TOT OUT . QN RLF Heat Cool 1. - . Attic .. - .6 175 ftz. 'Attic .. 65 ft2 Default Leakage. Attic.. (Default) (Default). .... . ... .. .... .. .: TEMPERATURES Programable Thermostat: Y . Ceiling Fans: Cooling Jan Feb Mar Venting Jan Apr Apr : May May. X Jun X Jul Jun X Aug X Sep- : Oct:, :Nov. �X� Dec - Dec,c .Feb Mar : Jul - Aug Sep Oct . X Nov Thermostat Schedule: HERS 2006 Reference Hours. Schedule, Type 1 2 3 4 - 5 6. 7 8 . 9 - .• . 10 11 12 Cooling.(WD) AM78 78 78 78- '78. 78. 78 78 80 .. 80 .- 80 80 PM '80 80 . 78 78 78 78 -_78 -78 78 '78. 78- 78 Cooling (WEH) AM. 78 . 78 78 78 .78_ 78 78- 78 78 .78 78- 78 PM 78 -78 78 78 78 78 '78 78 , 78: 78 78 78 Heating (WD) AM. 66 66 -66 66 66- 68: 68 - 68 68 68' 68: 68 PM :. 68 ... :68 .. 68. 68 68. 68 :.. 68 .. 68,- ,:.. 68 - 68 .. 66 .. ' . 66. Heating (WEH) AM- 66 66 66 66- 66 68- -68, 68 68 -68 68 68 PM. .68 68 68 ' 68 . .68 68• 68' 68."'. 68 68 66- 66 MASS Mass Type Area . Thickness Furniture: Fraction Space. Default(8.lbs/sIft. 0 ft2 0 ft . 0.3 - - BEDROOM-' Default(8 Ibs/sq.ft. ft'• ft- 0.3 • WIC Default(8 lbs/sq:ft.. _ ft2 ft • 0.3 M: BATH . - Def6ult(8lbs/sq:ft. : ft? ft 0:3 KITCHEN Default(8 Ibs/sq.ft., _ft' ft 0.3 BATH Default(8 Ibslsq.ft. ; .. ft2-ft 0.3 ; .. BEDROOM-2 Default(8.Ibs/sq.ft: _ . ft2 -ft 0:3 : ENTRY..- Default(81bs)sq.ft. ft' ft- 0.3 LAUNDRY.:' Default(8 Ibs/s .ft. ft' ft 0.3_ GREAT/DINING