Loading...
HomeMy WebLinkAboutInspectionsCode Compliance Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1148 httD://stlucieco.aov/ce r r , spections �`�?c C 1t4 AMP ,e�o 0608-0462 lob Address 17907 S INDIAN RIVER DR 'I/ it TysidenY(S r \pplication Type Master Permit w/subs Other Issued Activity Type New Stories 2 spection Area C Job Description CONSTRUCTION OF A NEW SINGLE FAMILY RESIDENCE Contractor Name CHESS WILLIAM K . Phone (772) 283 0452 Property Owner Business Name WC CUSTOM HOMES Inspection Notes CAN'T POUR hd UN L FORMBOARD SURVEY IS TURNED IN SHOWING Max Expiration Date 06/10/2008 ALL PORTIONE FORM OARD TO INCLUDE THE GARAGE AND PORCHES. WA SON ED A NEW SURVEY SHOWING THE HOUSE Inspector (Code)] Date Schedu Priority Sta�� In ector Date Inspected /6-4 Form Board Survey 7 Gas Piping 0 800 Address Final 6 Gary Scheigner 01/08/2008 810 Health Dept - Septic 7 820 Driveway/Culvert 7 105 Form Board Survey 7 493 Final Gas I 996 Final Termite Treatment 8 999 Final Inspection 8 821 Solid Waste 8 261 30 Day Expired 8 804 Driveway Bldg 8 808 Landscaping/Trees 8 Barbara Counsellor 11/16/2007 425 Sewer Connect 0 Approved Gary Scheigner 11/16/2007 02/16/2007 105 Form Board Survey 1 Accepted As Noted Lydia Galbraith 02/21/2007 IVR Access 01/03/2007 110 Footer/Foundation 1 Approved Gary Scheigner 01/03/2007 IVR Access 01/09/2007 119 Stem wall 1 Approved Gary Scheigner 01/09/2007 Shannon Boone 12/20/2006 104 Compaction Test 1 Approved Shannon Boone 12/20/2006 12/27/2006 105 Form Board Survey 1 Partial Approval Jodee Vorreyer 01/02/2007 IVR Access 02/06/2007 420 Plumbing Rough 1 Approved Greg Smyth 02/06/2007 Barbara Counsellor 02/22/2007 427 Temp.Toilet/Temp Culvert 2 Approved Gary Scheigner 02/22/2007 Barbara Counsellor 02/22/2007 103 Eufer Ground 2 Approved Gary Scheigner 02/22/2007 Barbara Counsellor 02/22/2007 115 Slab 2 Approved Gary Scheigner 02/22/2007 Barbara Counsellor 02/22/2007 121 Termite Spray 2 Approved Gary Scheigner 02/22/2007 IVR Access 03/14/2007 125 Tie Beam 3 Approved Gary Scheigner 03/14/2007 Audrey Humphrey 04/11/2007 133 Window/Door Bucks 4 Disapproved Gary Scheigner 04/11/2007 Audrey Humphrey 04/11/2007 134 Roof Sheathing 4 Approved Gary Scheigner 04/11/2007 Audrey Humphrey 04/11/2007 132 Floor Strapping/Joists 4 Approved Gary Scheigner 04/11/2007 Audrey Humphrey 04/11/2007 120 Kneewall 4 Not Required Gary Scheigner 04/11/2007 Audrey Humphrey 04/11/2007 137 Strapping 4 Approved Gary Scheigner 04/11/2007 Audrey Humphrey 04/11/2007 145 Truss Drwg 4 Approved Gary Scheigner 04/11/2007 08/15/2007 127 Mullion 5 Approved Gary Scheigner 08/15/2007 Barbara Counsellor 08/15/2007 135 Wall Sheathing 5 Approved Gary Scheigner 08/15/2007 08/15/2007 148 Window/Door Attachment 5 Approved Gary Scheigner 08/15/2007 Barbara Counsellor 08/15/2007 650 Frame -all 5 Cancelled by Building Dep Barbara Counsello 08/15/2007 Barbara Counsellor 08/15/2007 500 Smoke Draft Stop 5 Approved Gary Scheigner 08/15/2007 Barbara Counsellor 08/15/2007 178 Fireplace 5 Approved Gary Scheigner 08/15/2007 Barbara Counsellor 08/15/2007 136 Roof Dry-in/Tin Tab 5 Approved Gary Scheigner 08/15/2007 IVR Access 08/15/2007 133 Window/Door Bucks 5 Approved Gary Scheigner 08/15/2007 Barbara Counsellor 08/15/2007 351 Mechanical Rough-In(ducts) 5 Approved Gary Scheigner 08/15/2007 Barbara Counsellor 08/15/2007 238 Electric Rough 5 Approved Gary Scheigner 118115/2007 Barbara Counsellor 08/15/2007 423 Plumbing Top Out 5 Approved Gary Scheigner 08/15/2007 .f Code Compliance Division 2300 Virginia Avenue Inspections Ft. Pierce, FL 34982 Phone: (772) 462-1553 Fax: (772) 48 -htto://stlu iuciec cieco, aovlce Inspector Comments Re -inspection 2, 2/23 TALKED TO KEN ARNOLD, FOR THE SIDE PORCH THE COLOMS NEED TO GO UP BEFORE THE ROOF, SO THERE NEED TO BE FOOTERS. NEXT FORMBOARD NEEDS TO BE, CAN'T WAIT TILL THE DRIVEWAY GOES IN. L.GALBRAITH