HomeMy WebLinkAboutReport Foundation Pad CompactionleZAM,:0 °'' IVED' A. M. ENGINEERING AND TESTII I.Ir . 3504 INDUSTRIAL 33RD STREET DEC 2 Q 2006 FT. PIERCE, FLORIDA 34946 LOCALOFFICE: (772)461-7508 FAx: (772)461-8880 Pijbft Works 51. County, FL REPORT OF FOUNDATION PAD COMPACTION Client: WC Custom Homes 2740 SW Martin Downs Boulevard, Ste. 144 Palm City, Florida 34990 Site: 7907 S. Indian River Drive Ft. Pierce, St. Lucie County, Florida Foundation Pad Report Date: 12/20/06 Project No: Report No: 11257 Permit No: 0608-0462 Density tests and Hand Cone Penetrometer (HCP) readings were made at a minimum of three locations in the building pad. The density tests were performed in general compliance with ASTM D 2922. Density Test No. Date Tested Location Elevation (feet) Dry Densitv (i)sh Percent Compaction In Place Proctor 11257 12/13/06 NE Corner 0-1 101.8 105.0 97.0 Center 0-1 103.1 105.0 98.2 SW Comer 1 0-1 1 102.5 105.0 97.6 * All elevations are below slab grade (stripped surface). 14 There was no fill. At the time of our testing no information was available regarding the foundation pad setbacks. In the locations and depths that were tested, the soil has been compacted to a minimum of 95 percent of the modified Proctor maximum dry density (ASTM D 1557). No soil borings were performed below the recently placed fill. Distribution: Client - 2 Client (Fax) - 1 772-221-0544 Bldg. Dept. - 1 Submitted by: A. M. NGIIN�I'; D TESTING`INC. Paul C. Mirtin, P.V,. -- Florida Registration -No. 65051 r, IISERVER-AMEICompanylFort Pierce OfflceWeMppsILI7TLE LOG BOOKIHouse JobslMisc. House JobslSaint Lucie CountylWC Custom Homes(I1?57)7907 S.Indian River Dr. -StripSurf doc