KSM JOB #:218243-1d/BS/ah
NUC #528
Nuc Model:MC-1DR-P
Nuc Serial #:MD049528
10417 Muller Road
Fort Pierce, Florida
DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE (P.C.F)
PERCENT
COMPACTION
1 N.W.0" - 12"45 109.8 111.6 98.4%
2 N.E."40 110.9 "99.4%
3 Center "40 109.2 "97.8%
4 S.E."45 109.3 "97.9%
5 S.W."45 109.9 "98.5%
Proctor Optimum Moisture:
Proctor Max. Dry Density: P.C.F.
@ Test Locations the Density &
Penetrometer readings indicate the
Degree of Compaction Meets
10/8/2021
Certified Women Owned Business - WBE
Minimum Requirement
for Unstaked Foundation
In Place Moisture:
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
October 7, 2021DATE TESTED:
9.5%
12.0%
Brown Gray Sand
Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting
Respectfully Submitted:
ITEM TESTED:
111.6
TEST LOCATION
OF SAMPLE
Proudly Serving Florida since 1990
Disclaimer:Contractor is responsible to maintain the tested area
in the condition that KSM completed the indicated passed
compaction test.KSM is not responsible if the tested area has
been altered from the approved inspected condition.
PERMIT #:
CONTRACTOR:B & D Grading
Julie E. Keller, P.E. President
Soil Description:
JOB LOCATION:
Main House Pad, Below Stripped Surface Testing - Native Ground
Email to: bdgrading@att.net
PE # 68366