HomeMy WebLinkAboutbuilding residentalINSULATION INSTALLATION CERTIFICATE
Oakmont
TO:
JOB#: 1 151 1 6 JOB NAME: Hribar Res
LOT BLOCK: SECTION:
JOB ADDRESS: 1 12 Island Dunes Cove
The undersigned hereby certifies that insulation has been installed at the.above described property as
follows:
1. Exterior CBS walls have been insulated with ............................Check one
()Spray on cellulose
to a thickness of N/A
inches, which thickness, according to the
( ) Fiberglass blankets
manufacturer,
CFI
( ) Aluminum Foil
Density N/A
will yield an "It" value of 9
00 block fill
Exterior Frame walls have been insulated with ............................Check one
() pray once u use
to a thickness of 6,25
inches, which thickness, according to the
( Fiberglass blankets
manufacturer,
Certainteed
( ) Aluminum Foil
Density N/A
will yield an "R" value of 19
( ) Other Spray Foam
2. Main Ceilings have
been insulated with .........................Check one
( ) Fiberglass blankets
to a thickness of 5,25
inches, which thickness, according to the
( ) Fiberglass loose fill
manufacturer,
ES Sucraseal
( ) Aluminum Foil
Density N/A
will yield an "R" value of 20
(X) Other Js
Ya foam
Ceilings Cathedral
have been insulated with .........................Check one
( ) Fiberglass blankets
to a thickness of
inches, which thickness, according to the
( ) Fiberglass loose fill
manufacturer,
( ) Aluminum Foil
Density N/A
will yield an "R" value of
( ) Other Cellulose
3. Interior knee walls have
been insulated with.................................Check one
( ) Fiberglass blankets
to a thickness of 5.25
inches, which thickness, according to the
( ) Polyurethane
manufacturer,
SES Sucraseal
( ) Spray on cellulose
Density N/A
will yield an "R" value of 20
(1) Other Spray Foam
4. Garage partition walls of conditioned living areas have been
insulated with................................................................................Check one ()Fiberglass blankets
to a thickness of inches, which thickness, according to the ( ) Spray on cellulose
manufacturer, ( ) Polyurethane
Density N/A will yield an "R" value of ( ) Other Aluminum Foil
MULTI FAMILY RESIDENTIAL CONSTRUCTION ONLY: The common (party) walls separating
different tenants shall be insulated asfollows -Frame/Metal stud walls R-I l (Min.); CBS or Concrete walls
A (Min.); by Energy Code requirements. See Energy Code Rev. I/87, paragraph 903.2(b), on page 9-17,
latest edition. These "minimums levels of insulation" are not included in the Energy Calculations, but shall
be installed in the field.
NOTE: Densities of sprayed on, loose fill, or any other composed -on site insulation shall be the P.C.F.
(Ib/ft3) average of three (3) "DRY SAMPLES" of actual installation.
Ins la '
1 1\ l
' KELLY LYOU\G
ri�%�'�`'�', \ofary Pvhlic-S�z:e of Florida
`ate Cemmissicr: CG f933a2
'�����:�'! My Gmm. Evciret lu11.3013
anrded thr®itch %a:w a \ctary Assr.