Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of -Business -and Professional Regulation - Residential Performance Method Project Name: ZEIGLER RESIDENCE Builder,Name: Street: 9807SANDIAN RIVER DRIVE Permit Office: City,,State, Zip: FT. PIERCE, FL, Permit Number: Owner: Juris diction: Design Location: FL, Fort Pierce 1. New construction or existing Existing'(Projecte 9, Wall Types (1616.0 sqft) Insulation Area 2. Single family or multiple family Single-family a;. Frame - Wood,.Exterior R=1 1,0 1616.00 ft". b. N/A R= ft2 3. Number of units, If multiple family 1 c. N/A. R= Itz 4. Number of Bedrooms 3 d. N/A R= ft2 0. Ceiling Types (1 644iO sqft.) Insulation Area 5. Is this a. worst. case? No a; Under Atfic. (Vented)' R=16.0 .1644.00 ft2 6. Conditioned floor area above grade (ftz) 1644 b. N/A R= ft2 c. N/A. R= ftz Conditioned.floor area below grade (ft) 0 11. -Ducts R ft'. 7. Window s(300.9 sqft.) Description Area a. Sup�, Attic,. Ret: Attic, AH: Main, 6 205 a.- U-Factor: Sql, U=0.60 300.89 W SHGC: SHGC=0.40 b. U-Factor: N/A ft2 12. Cooling systems- kBtu1hr Efficiency SHGC: a. Central Unit 35.0 SEER:16.00 0. U-Factor: N/A ftz SHGC: 13. Heating systems- kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat27.0 COP1.00 SHGC: Area Weidl-itedAveraige.Overhang Depth: 2.739 ft. Area Weighted Average - SHGC: ..0.400 14.. Hot water systems d. Floor Types (1644.0 'sqft.) Insulation Area a, Electric Cap: 40 gallons a.Raised Floor R=19.0 1644.00 ft' b. Conservation features EF: 0.920 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.183 Total Proposed Modified Loads: 37.67. DASS. Total. Standard Reference Loads: 46.96 I hereby certify that the plans and specifications covered by Review of the plans and SHE S this calculation are in compliance with the Florida Energy specifications covered by this V 0 Code, calculation indicates compliance PREPARED DATE: t 44- .with the FloridaEnergy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that. his. building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWN ER/AGENT: BUILDING OFFICIAL: ........... .. DATE: -- - ------ - --- 7 - - ----- DATE:' - - ---------- 11/17120149:57AM Energypauge@ USA - FlaRes201 0 section 405.4.1 Compliant Software Page 1 of 5 PROJECT Title: ZEIGLER RESIDENCE Bedrooms: 3 Address Type: Sireet.Address Building Type: User Conditioned Area: 1644 Lot # Owner: Total Stories: 1 BlocklSubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 9807 S. INDIAN RIVER Permit Office:. Cross Ventilation: No . County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: Yea City, State, Zip: FT. -PIERCE, Family Type: Single-family FL, New/Exisfing: Existing (Projected) Comment: CLIMATE / IECC Design Temp Int Design Temp. Heating Design .Daily Temp V Design Location TMY Site Zone 97'.5 % 2.5 % Winter Summer Degree Days Moisture Range _------- _--- - _. �.-------------— FL, Fort Pierce FL_ST LUCIE CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Block1. 1644 13152 SPACES Number Name Area Volume Kitchen Occupants Bedrooms infilID Finished Cooled Heated 1 Main 1644 13152 Yes 4 3 1 Yes Yes Yes FLOORS,. # Floor Type Space R-Value Area Tile .Wood Carpet 1 Raised Floor Main __ _ ____ 1644 ft2 19 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1781 ftT 0 ft2 Medium 0.96 No, . 0.9 No 0. 22.6 ATTIC Vent Ratio in) Area RBS IRCC V # Type Ventilation (1 1 Full attic Vented 300 1644 ft2 N N CEILING # Ceiling Type Space R-Value . Area Framing Frac Truss Type 1 Under Attic (Vented) Main 19 1644 ft2 .0.11 . Wood 11/1712014 9:57. AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software. Page 2 of 5 r WALLS Adjacent Space Cavity Width Height Sheathing- FramingSolar value- _ F�-,-In-•---F�...._1n__ Area-__:R:aLaloe-F�action._._..Nbsnr__ Below Grade"In _�/_# OmL_..__•_7 a_�__1l11alLTppe------------------,----------..-1� 11 65 8 520.0 W 0 0.75 0 1 N Exterior Frame Wood Main _ .2 E Exterior Frame - Wood Main 11 36 8 288.0 ft2. 0 0,75 0 3 S Exterior Frame - Wood Main 11 65 8 520.0 ft2 0 0:75 0 ^.4 W Exterior Frame - Wood Main 11 36 - 8 288.0 ftz 0 0.75. 0 WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Omt ID Frame Panes NFRC ---- U-Factor SHGC Area -- - --- -- -- - - _ - Overhang Depth.. Separation - - -- -- - Int Shade Screening _ - -- 1 ----- ... _-- -- -----------.-._._. N 1 Metal Single (Tinted) Yes 0.6 0.4 18:0 ft2 2 ft 0 ink 6 ft 0 in Drapesfblinds None - 2 N 1 Metal Single (Tinted) Yes 0..6 0.4 33.3 ft2 2 ft 0 in 6 ft 0 in Drapeslblinds None 3 E 2 Metal Single (Tinted) Yes 0.6 0.4 16.7 ft2 . 2 ft O.in 6 ft O.in Drapes/blinds None 4 E 2 Metal Single (Tinted) Yes 0.6 0.4 16.0 ft= 2 ft 0 in 6 ft 0 in Drapes/blinds None 5 5 3 Metal Single (Tinted) Yes 0.6 0.4 33.3 W2 ft 0 in 6 ft 0 in Drapeslblinds None 6 S 3 Metal Single (Tinted) Yes 016 GA 112.0 ftz 2 ft 0 in 6 ft 0 in Drapes/blinds None 7 S 3 Metal Single. (Tinted). Yes 0.6 0.4 26.0 ft2 6 ft 0 in 6 ft0.1n . brapes/blinds None .8 W 4 Metal Single (Tinted) Yes 0.6 0.4 16.0 ft2 2 ft.0 in 6 ft 0. in Drapes/blinds None 9 W 4 Metal Single (Tinted) Yes 0.6 0.4 35.6 ft2 6 ft 0 in 6.ft0 in. Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 EIA Eg1A ACH ACH 50 1 Wholehouss Best Guess -.0005 2156.1 118.37 222.61 .365 9.8363 HEATING SYSTEM # Type -- - Subtype _ --- � Efficiency _ Capacity - _ Block Ducts -- 1 _System Electric Strip Heat - -� None COP: 1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # . System Typ e Subtype Efficiency. Ca aci. Air Flow Y p ry - --- SHR Block . -= ----Ducts Ducts 1 Central Unit None SEER: 16 35 kBtulhr 1050 cfm 0:75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Pao. Use SetPnt Conservation 1 Electric None Main 0.92 40 gal 60 gal 120 deg None 11/17120.14 9:57 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software _ Page 3-of 5 SOLAR HOT WATER SYSTEM F-V Collector Storage. FSEC Cert # Company Name System Model # Collector Model # . Area Volume FEF None None DUCTS — Supply — -- Return-- Air CFM 25. CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF . Heat Cool 1 Attic 6 205 ft2 Attic 25 ft2 Default Leakage Main (Default (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans; Cooling Jan Heating Jan Feb Mar Feb Mar Apr Apr € May X Jun X Jul May Jun Jul I IJul Aug Aug rl Sep �Xj Sep Sep_ Oct Oct Oct Nov Nov Nov: Dec Dec Dec Venting Jan Feb XMar XApr _ — — May .Jun -- _ Aug - — _ _ Thermostat Schedule:— HERS 2006. Reference Hours 12 Schedule Type. 1 2 3 4 5 6 7 8 9 10 11 Cooling.(VVD) AM 78 PM 80 78 80 78 78 78 78 78 78 78. 78 78 78 78 78 80 - 78 80, 78 80 78 80 78 Cooling (WEH} PM 78 78 78 78 78 78 78 78 78 78 .78 78 Heating (WD) PM 68 68 66 68 66 68 68 68 68 .68 68 68 68 68 66 66 Heating(WEH) AM 66 PM 68 66. 68 66 68 66 66 68 68 68 68. 68 68 68 68 68 68 68 68 68 66 68 66 1111712014 9:57 AM EnergyGauge® USA - FlaRes2010. Section 405.4.1 Compliant Software Page 4 of 6 .n FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: ' 9807 S. INDIAN RIVER DRIVE PERMIT #: FT..PIERCE, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT i SECTION SUMMARY OF REQUIREMENT(S) Air leakage 1 402.4 i To be caulked, gasketed, weatherstripped orotherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and. Ij i doors = 0.30 cfm/sq.ft. Testing or visual. inspection required. Fireplaces: gasketed doors & outdoor combustion -air. Must complete ! envelope leakage repor( or visually verify Table 402.4.2. i Thermostat. 1 403.1 — At least one thermostat shall be provided for each separate heating.. controls i and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps. with. supplemental electric heat must prevent supplemental heat. when compressor can ! meet the load. Ducts ! 403.2.2 I All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall ! be considered ducts or plenum chambers, shall be constructed .and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 . Building framing cavities shall not be used as supply ducts. __---------------- Water heaters. 4.03.4 Heat trap required for vertical pipe risers. Comply.with efficiencies in Table 40.3;4.3.2. Provide switch or clearly marked circuit breaker (electric) or.shutoff (gas). Circulating system pipes insulated to = j R-2 + accessible manual OFF switch. Mechanical + 403.5 I Homes designed to operate at positivepressure or with mechanical ventilation ! ventilation systems shall not exceed the minimum ASHRAE 62 level. ! ! 'No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. i swimming Pools 403.9 - Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall. have the capability of operatirig at two or. more speeds. Spas and heated pools must have vapor -retardant covers. or a liquid cover or I other means proven to reduce .heat loss except if 70% of heat from site -recovered energy. Off/timer-switch required. Gas heaters minimum i I thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4:0. Cooling/heating 1403.E Sizing calculation performed &.attached. Minimum efficiencies. per I I Tables.503,2:3. Equipment efficiency verification required. Special j equipment j occasion cooling or beating capacity requires separate system or j 1 variable capacity system. Electric heat >1.OkW must be divided into two I i or more stages. Ceilings/knee walls 405:2.1 R-19 space permitting. I CHECK 11/17/2014 9:57 AM EnergyGauge@ USA - FlaRes2010.Section 405A.1 Compliant Software Page 5 of 5 v v D 9 P L YTCARD • ESTIMATED ENERGY PERFORMANCE INDEX* = 80 The lower the EnergyPerformance Index, the more efficient the home. 9807 S. INDIAN RIVER DRIVE, FT. PIERCE, FL, 1. New construction or existing Existing (Projecte 9: Wall Types Insulation Area a. Frame -Wood, Exterior R=11.0 1616.00 ft2 2. Single family or multiple family Single-family b. NIA R= ft 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. is this a worst case? No a. Under Attic (Vented) R=19.0 1644.00.ft' 6. Conditioned floor area (ft2) 1644 b. NIA R= ft2 c. N/Acts R= ft2 T. Windows" Description Area Du 11. Duucts R ft2 a. U-Factor: Sgl; U=6.60 300.89 ft2 a..Sup: Attic, Ret: Attic,, AR Main • 6 205 SHGC: SHGC=0.40 b. U-Factor. N/A ft2 SHGC: 12. Cooling systems kStu/hr.. Efficiency c. U-Factor: N/A ft2 a. Central Unit 35.0 SEER:16.00 SHGC: d. U-Factor: NIA ft2 13. Heating systems kbtu/hr . Efficiency SHGC:. a. Electric Strip Heat 27.0 COPA1 00 Area Weighted Average Overhang Depth: 2.739 ft. Area W.eighted Average SHGC: 0,400 8. Floor. Types. Insulation Area 14. Hot water systems Cap: 4.0 gallons a. Raised Floor R=19.0 1644.00 ft2 a. Electric EF: 0.92 b. NIA R= ft2 b. Conservation features c. N/A. R= ft2 None 15, Credits Pstat I certify that this home has complied with the: Florida Energy Efficiency Code. for Building; Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Cade compliant features. . Builder Signature: Address of New Home: Date: City/FL Zip: "Note: This is not a Building Energy Rating. If your Index is below,70, your home may qualify for energy efficient mortgage .(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638A4k or.see the EnergyGauge web.site at energygauge.com for information and a list of certified Raters. For information about the Florida Building'Code, Energy Conservation; contact the Florida Building Commission's support staff. *'Label required by Section 303.1.3 of the Florida Building, Code, Energy Conservation, if not DEFAULT. �1 EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software