Loading...
HomeMy WebLinkAboutENGINEERING CALCULATIONS Forensic Engineering Consultants, Inc. BASE SHEET/TAG &STICK ATTACHMENT CALCULATIONS Project Name Coastal Orthopaedics Sports Medicine Center Report No.: ATRT-BS-22.008 Project Address 7710 S. Federal Highway Port St. Lucie, FL- 34952 Deck Substrate Wood Non-Insulated Mean Roof Height 15.0 Feet Configuration Steep Slope Roof Area (Approx.) Sq.Ft. Category II Roof Width 74.0 Feet Exposure Condition C Perimeter Width 6.0 Feet Building Type Enclosed Parapet Height 0.0 Feet Base Wind Speed 170 mph Sloped Roof Type Slope V 4.0 Slope H 12.0 Slope Angle° 18.43 Uplift Pressures qZ = 0.00256 KZ KZt Kd Ke V2 P = qZ (GCp- GCpI) qz KZ Kzt Kd Ke V GCp GCp; 53.453 0.850 1.000 0.85 1.00 170 -2.00 0.18 Field -2.00 0.18 Eave Perimeter -3.00 0.18 End Perimeter -3.00 0.18 Ridge Perimeter -3.00 0.18 Eave Corner -3.60 0.18 Ridge Corner Field (1) P1 ult. -116.53 psf P1 asd -69.92 psf Eave Perimeter(2e) P2e ult. -116.53 psf Pee asd -69.92 psf End Perimeter(2n) P2n ult. -169.98 psf Pen asd -101.99 psf Ridge Perimeter(2r) P2r ult. -169.98 psf Per asd -101.99 psf Eave Corner(3e) P3e ult. -169.98 psf Pie asd -101.99 psf Ridge Corner(3r) P3r ult. -202.05 psf Par asd -121.23 psf Proposed System Base Sheet and Polyglass Polystick Underlayments Product Approval No. 21-0602.14 (Page 4 of 7) System Design Pressure psf Fasteners Approved Nails and Tin Caps Base Sheet Width 39 inches Side Lap 3 inches Net Width 36 inches Fastener Spacing in Lap of Base Sheet 12 inches # Rows 1 Fastener Spacing in Field of Base Sheet 12 inches # Rows 2 Min. Characteristic Resistance Force -70.00 Ibf(Estimate) Fastener Spacing {(MCRF/Pi)x 1441/Row Spacing No. of Rows of Fasteners 3 4 5 Field & Eave Perimeter Fastener Spacing 12.01 16.02 20.02 Ridge&End Perimeters Fastener Spacing 8.24 10.98 13.73 Ridge&Eave Corners Fastener Spacing 6.93 9.24 11.55 RECOMMENDED BASE SHEET ATTACHMENT PATTERN Field 1 row in the laps at 12 inches o.c. 2 rows in the center of the sheet at 12" o.c. Perimeter 1 row in the laps at 8 inches o.c. 2 rows in the center of the sheet at 8" o.c. Corner 1 row in the laps at 6 inches o.c. 2 rows in the center of the sheet at 6" o.c. These calculations have been done in accordance with ASCE 7-16, based on the information provided by the contractor. The roof system must be installed in accordance with the FBC & manufacturer's recommendations. Ensure that roof system meets insulation &fire rating requirements of the Florida Building Code, before installation. `t�tttt� �►,,,� Sincerely �P\LAPpq Forensic Engineering Consultants, Inc. �• "" Ravanasamudram N Digitally signed by V�GENSF '•• Ravanasamudram N Sailappan Q No.46696 Sailappan Date:2022.01.12 17:52:14-05'00' -* . •t, R. N. Sailappan, P.E. Florida Registration No. 46696 '. STATE OF �AZ Forensic Engineering Consultants, Inc. (CA#8265), �k• . 6 ,•B* I ton, FL-33497 Ph(561)901 8490 Fax(561)218 3830 /0NA r� �os` l`