Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM 11DOA-08 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: JAKSCH RESIDENCE Builder Name: EMPORIUM HOMES Street; 4SU ARCADIA AVENUE Permit Of6ca: Sr- LUCE COUNIV Cit/, State, Zip: FT. PIERCE, FL Permit Number: Owner. Juribdation. Design Location: FL, FT. PIER= 1. New construction or existing New (From Plan) 0, Wall Typea (96.9.24 agft.) Inatilofan Ames 2. Sngfe family or muibple family Sn&-famly a. Concrete Gloek - Fact Insul. E4edor R=4.0 969.24 W b. Frome-INcod, Adjacent R= W 3. Number of units, if multiple family 1 c. IVA RE $_ 4. Number of Bearoorrs 2 d. WA Ft. fe S. Is this a worst case? Nn 10. Celina Types (1013A saft) koulatisn Area 6. Canditioned Roor area (110) 1013 a. Under Attic (Vented) R=30 L 101300 IF b. NIA R. � 7. Windows(65AB sqe.) Description Area c. MIA R= ft: a. U-Factor: Sgl,Ue1.30 GSA ip SHOO. SHGC=4.75 11' Ducts b. U-FtwW. NIA a. Sup: Attic Rot Atli AH: U1T.CL Sup. R= t3, 93 fta SHOO: 12. Cooling systems (combined) c. U-Factor. NIA na a, central U111 Cap: 80.5 t5tu1hr SHOO: SEER:14 d. ll-Factor: NIA ftz 13. Heating systems (combined) SHGC: Q. elcamo Heat Pump Cap: 80.6 k8bdhr e. Wactor NtA ft' HSPF:8.29 MCC: 14. Nat water cystemv 8. MoarTypres (1015.0 sgft.) Insulation Area a. EtactrL^ Cap:40 aalens a. Slab -On -Grade, Edge Insuldtlon R=0.0 1013.09 fl? EF: 0.9 b. NIA R= fFh. Conxerualron features e. NIA Re fe None 16. Credits CF, PrJat Total As -Built ModMed Loa : 76.74 GlasSIFloor Area: 0.065 PASS Tr�1al Rarcatina arlc 92 09 hereby certify that the plans speelficatio cove by Review of the flans wnrl 'C><ttr rqT this calculation are In com rice with the orgy Code, t3pOeifi .dtions �vered by thi:, calculation indicates comptance ti+0:" with the Florida Energy Cody. f PREPARED - BY: Before construction is completed I DATE: - thls building vill be Inspected fir compliance with Section 553.90E tz;o 1 hereby celiity that this buiI ' , as desaispl'ranoe Florida Statutes. witr, the Florida Energy. <WE OWNERIAGENT: BUILDING OFFICIAL: DATE:. DATE: f[ PROJECT Title: JAKSCH RES. Bedrooms: 2 Adress Type: Street Address Building Type: FLAsBuilt Conditioned Area: 1013 Lot # Owner: Total Stories: 1 Block/SubDMsion: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 4640 ARCADIA AVE Permit Office: Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, FLORIDA Family Type: Single-family New/ExIsting: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, FT. PIERCE FL WEST_PALM_BEAC 2 44 90 75 70 316 60 Medium FLOORS # Floor Type Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio 129.3 ft 0 1013 ft2 0 0 1 ROOF / Roof Gable Roof Solar Deck V # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 Hip Composition shingles 1068 ft2 0 ft2 Medium 0.9 N 0 18.4 deg ATTIC V # Type Ventilation Vent Ratio (1 in) Area FIBS IRCC 1 Full attic Vented 300 1013 ft2 N N CEILING # Ceiling Type R-Value Area Framing Frao Truss Type 1 Under Attic (Vented) 30 1013 ft2 0.1 Wood WALLS Cavity Sheathing Framing Solar # Ornt Adjacent To Wall Type R-Value Area R-Value Fraction Absor. 1 N Exterior Concrete Block - Ext Insul 4 213 ft2 0 0 0.8 2 E Exterior Concrete Block - Ext Insul 4 265 ft2 0 0 0.8 3 S Exterior Concrete Block - Ext Insul 4 183 ftz 0 0 0.8 4 W Exterior Concrete Block - Ext Insul 4 268 ft2 0 0 0.8 5 - - Frame - Wood - 0 ft2 0 0 0 Page 2 of 5 DOORS # Omt Door Type Storms U-Value Area 1 S Insulated None 0.39 20 ft2 WINDOWS Orientation shown is the entered, asBuilt orientation. / V # Omt Frame Panes NFRC U-Factor SHGC Storms Overhang Area Depth Separation. Int Shade Screening 1 2 3 4 S Metal E Metal E Metal W Metal Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes 1.3 0.75 N 1.3 0.75 N 1.3 0.75 N 1.3 0.75 N 10 ft2 8 ft 0 in 6 ft Sin 23 ft2 8 ft 0 in 6 ft Sin 16ft2 8 ft 0 in 6 ft 8 in 16 ft2 8 ft 0 in 6 ft Sin HERS 2006 HERS 2006 HERS 2006 HERS 2006 None None None None INFILTRATION & VENTING / V Method SLA CFM 50 ACH 50 ELA EgLA ---- Forced Ventilation -- Run Time Supply CFM Exhaust CFM Fraction Fan Watts Default 0.00036 3742 6.30 205.4 386.4 0 cfm 0 cfm 0 0 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 - 0ft2 Oft 0. ft 0 COOLING SYSTEM . # System Type Subtype Efficiency Capacity Air Flow SHR Ducts 1 Central Unit None SEER: 14 24 kBtu/hr cfm 0.7 sys#1 HEATING SYSTEM # System Type Subtype Efficiency Capacity Ducts 1 Electric Heat Pump None HSPF: 8.5 24 kBtu/hr sys#1 HOT WATER SYSTEM # System Type EF Cap Use SetPnt Conservation 1 Electric 0.9 40 gal 70 gal 120 deg None Page 3 of 5 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS / --- Supply--- ---- Return ---- Air Percent # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF 1 Attic 6 98 ft' Attic 20 ft2 Default Leakage Int. Closet (Default) (Default) % TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [X] Jan HeatinC1]C Jan [[XX]] Feb [XJ Feb [[XX]] [X] Mar Mar [[XXJJ [XJ Apr [[XX]] Ma [[XXJJ Jun [XJ Jul Apr [XJ May [XJ Jun [ jX Jul Au Au[XJ [[XXJJ Se S [[XX]] Oct [[XX]] pCJ Oct [X] Nov Nov Dec X Dec Venting[[�X]] Jan [[�X]] Feb [[�X]] Mar [[�X]] Apr [[XX]] May [[�X]] Jun LL�XJJ Jul Aug [[fix]] Sep Oct [[�X]] Nov [[�Xll Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Page 4 of 5 FORM 1100A-08 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: 4640 ARCADIA AVENUE PERMIT #: FT. PIERCE, FLORIDA INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHE Exterior Windows & Doors N1106.AB.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls N1106.AB.1.2 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors N1106.AB.1.2 Penetrations/openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, Penetrations and seams. Ceilings N1106.AB.1.2 Between walls & ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures N1106.AB.1.2 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC with <2.0 cfm from conditioned space, tested. Multi -story Houses N1106.AB.1.2 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters N1112.AB.3 Comply with efficiency requirements in Table N1112.ABC.3 Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. Swimming Pools & Spas N1112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems N1110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section N1110.AB. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for each s stem. Insulation N1104.AB.1 Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both N1102.13.1.1 sides. Common ceiling & floors R-11. Page 5 of 5