HomeMy WebLinkAboutEnergy Efficiency CoderFORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR'BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Standard Pacific RB Stamford Lot 32
Builder Name: Standard Pacific Homes
Street: 15329 N,W 1' t
Permit Office: St. Lucie
City, State, Zip: Port St. Lucie , FL ,
Permit Number:
Owner: Standard Pacific Homes
Jurisdiction:
Design Location: FL, Fort Pierce WT- 32
1. New construction or existing New (From Plans)
9. Wall Types (3971.5 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 3646.00 ft2
b. Frame - Wood, Adjacent
R=11.0 325.43 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (3518.0 ,sgft.)
Insulation Area
a. Under Attic (Vented)
R=38.0 3518.00 ft2
6. Conditioned floor area above grade (ft2) 3518
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(965.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AC 1 First
Floor 6 640
a. U-Factor: Dbl, U=0.60 472.06 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl, U=0.59 288.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.32
a. Central Unit
57.0 SEER:15.00
c. U-Factor: Dbl, U=0.77 136.00 ft2
SHGC: SHGC=0.22
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 68.99 ft2
a. Electric Heat Pump
56.0 HSPF:8.50
SHGC: other (see details)
Area Weighted Average Overhang Depth: 8.469 ft.
Area Weighted Average SHGC: 0.300
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (3518.0 sqft.) Insulation Area
EF: 0.910
a. Slab -On -Grade Edge Insulation R=0.0 3518.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.274 Total Proposed Modified Loads: 47.48
PASS
Total Standard Reference Loads: 65.81
I hereby certify that the plans and specifications covered by
Review of the plans and
Sr`fT6'
this calculation are in compliance with the Florida Energy
specifications covered by this
0ollE
1•
Digitally signed by Chris Wildroudt
Code. DN: cn=Chris Wildroudt, c=US,
Chris o=Engineered Air, LLC, ou=New
calculation indicates compliance
p
with the Florida Energy Code.
`! '%fY "-
nrru
Construction Sales
and
PREPARED BY:-Enginerring--
Before construction is completed
DATE: I �d �OUCI-t ccm�il=ch!isw �noineeredairuo.
this building will be inspected for
"wwr O
Date: 2014.06.18 09:15:16-04'00'{
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Cod
COD WT~�
OWNER/AGENT:
-BUILDING OFFICIAL:
DATE: rJZ-71 IYC
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with 403.2.2.1.1.
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
- Heat sys #1 may be undersized. Size of 56.0 was increased to 69.2 for simulation. Please review the Manual J8 report.
6/18/2014 9:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6
__. ..
' .. PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Standard Pacific RB Stamford
User
Standard Pacific Homes
1
Standard Pacific Homes -
St. Lucie
Single-family
New (From Plans)
Bedrooms: 4
Conditioned Area: 3518
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Lot Information
32
Riverbend
St. Lucie
Port St. Lucie ,
FL,
CLIMATE
V Design Location TMY Site
IECC Design Temp
Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90
70
75 722
62 Low
BLOCKS
Number
Name Area
Volume
1
Block1 3518
37710.1093
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
AC 1 First Floor 3518
37710.1104 No 5
4
1 Yes
Yes Yes
FLOORS
#
Floor Type Space
Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio AC 1 First Floor 372 ft 0
3518 ft2
__-_
0 0 1
ROOF
V #
Type Materials
Roof Gable Roof
Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip Barrel tile
3934 ft2 - 0 ft2 Medium
0.65
No 0.9
No 0 26.6
ATTIC
/
r V #
Type Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic Vented 300 3518 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Area
Framing Frac
Truss Type
1
Under Attic (Vented) AC 1 First Floor 38 '3518 ft2
0.11
Wood
6/18/2014 9:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6
._..•
WALLS
Adjacent
Wall lypeSpace: -
Cavity
_ P
Width Height
Ft �nFt In
Area
Sheathing Framing
-Val-le Fraction
Solar Below
at,��r r� °
_ 1 E
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
13
0 10.67 0
138.7100
0.4
0
0.4
0
2 E
Exterior
Concrete Block - Int InsAC 1 First Flo
(4.1
10
0 10.67 0
106.6999
0.4
0
0.4
0
3 -'E
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
13
0 10.67 0
138.7100
0.4
0
0.4
0
_ 4 E
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
12
0 10.67 0
128.0400
0.4
0
0.4
0
5 S
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
80
0 10.67 0
853.5999
0.4
0
0.4
0
6 S
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
13.5
0 10.67 0
144.0449
0.4
0
0.4
0
_ 7 . W
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
34
0 10.67 0
362.7799
0.4
0
0.4
0
8 W
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
20
0 12.67 0
253.3999
0.4
0
0.4
0
9 N
Exterior
. ' Concrete Block - Int InsAC 1 First Flo
4.1
14
0 10.67 0
149.3800
0.4
0
0.4
0
10 N
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
24
0 10.67 0
256.0800
0.4
0
0.4
0
11 N
Garage
Frame - Wood AC 1 First Flo
11
8
0 10.67 0
85.36000
0.4
0.4
0
12 W
Garage
Frame - Wood AC 1 First Flo
11
6
0 10.67 0
64.02000
0.4
0.4
0
13 W
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
18
0 10.67 0
192.0599
0.4
0
0.4
0
_ 14 N
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
50
0 10.67 0
533.5 ft2
0.4
0
0.4
0
15 S
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
6
0 10.67 0,,
64.02000
0.4
0
0.4
0
16 E
Garage
Frame - Wood AC 1 First Flo
11
16.5
0 10.67 0
176.0550
0.4
0.4
0
17 S
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
12
0 10 0
120 ft2
0.4
0
0.4
0
18 E
Exterior
Concrete Block - Int InsAC 1 First Flo
4.1
20.5
0 10 0
205 ft2
0.4
0
0.4
0
DOORS
#
Ornt
Door Type Space
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated AC 1 First Flo
None 0.6
2.67 0
8 0
21.36 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V/ #
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Area
Depth Separation
Int Shade
Screening
1
E 1
Metal Low-E Double Yes
0.77
0.22
48 ft2
23 ft 0 in
2 ft 0 in
None
None
2
E 1
Metal Low-E Double Yes
0.4
0.31
21.28000
23 ft 0 in
2 ft 0 in
None
None
3
E 2
Metal Low-E Double Yes
0.77
0.22
48 ft2
13 ft 0 in
2 ft 0 in
None
None
4
E 3
Metal Low-E Double Yes
0.6
0.31
16.17000
6 ft 0 in
2 ft 0 in
None
None
5
E 4
Metal Low-E Double Yes
0.77
0.22
40 ft2
8 ft 0 in
2 ft 0 in
None
None
6
S 5
Metal Low-E Double Yes
0.6
0.31
116.9783
1.33 ft 0 i
2 ft 0 in
None
None
7
S 5
Metal Low-E Double Yes
0.6
0.31
22.68000
1.33 ft 0 i
2 ft 0 in
None
None
8
S 5
Metal Low-E Double Yes
0.6
0.31
9.180000
1.33 ft 0 i
2 ft 0 in
None
None
9
S 6
Metal Low-E Double Yes
0.59
0.32
80 ft2
18 ft 0 in
2 ft 0 in
None
None
10
W 7
Metal Low-E Double Yes
0.6
0.31
116.9783
1.33 ft 0 i
2 ft 0 in
None
None
11
W 8
Metal Low-E Double Yes
0.59
0.32
128 ft2
12 ft 0 in 4.67 ft 0 i
None
None
12
W 8
Metal Low-E Double Yes
0.4
0.31
24.88439
12 ft 0 in
1 ft 0 in
None
None
13
N 9
Metal Low-E Double Yes
0.59
0.32
80 ft2
18 ft 0 in
2 ft 0 in
None
None
14
N 10
Metal Low-E Double Yes
0.6
0.31
22.68000
9 ft 0 in
2 ft 0 in
None
None
15
W 13
Metal Low-E Double Yes
0.6
0.31
58.48919
1.33 ft 0 i
2 ft 0 in
None
None
16
N 14
Metal Low-E Double Yes
0.6
0.31
27.34560
1.33 ft 0 i
2 ft 0 in
None
None
6/18/2014 9:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6
:.
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V ' r # -
Wall
Ornt ID Frame
Panes NFRC
Overhang
U-Factor SHGC Area Depth Separation Int Shade
Screening
17
18
19
20
21
22
N '14 Metal
N 14 Metal
N " 14 Metal
N 14 Metal
S 15 Metal
S 17 Metal
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
Low-E Double Yes
0.6 0.31 38.99279 1.33 ft 0 i 2 ft 0 in None
0.6 0.31 9.180000 1.33 ft 0 i 2 ft 0 in None
0.4 0.31 16.17000 1.33 ft 0 i 2 ft 0 in None
0.4 0.31 6.652800 1.33 ft 0 i 2 ft 0 in None
0.6 0.31 13.67280 1.33 ft 0 i 2 ft 0 in None
0.6 0.31 19.71199 2 ft 0 in 1 ft 0 in None
None
None
None
None
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
660 ftz
660 ftz
72 ft loft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Best Guess
0.000500
4613.8 253.29 476.36 0.3650 7.3410
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Heat Pump None
HSPF: 8.5 56 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit
Split
SEER: 15 57 kBtu/hr 1710 cfm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType Location
EF Cap Use SetPnt Conservation
1
Electric
None Garage
0.91 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
#
--- Supply - --- Return -- Air Percent
Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF
HVAC #
Heat Cool
1
Attic
6 640 ftz Attic
160 ft' Default Leakage AC 1 First F (Default) (Default) %
1 1
6/18/2014 9:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6
-'
:TEMPERATURES
Programable Thermostat:'Y - ' -
Ceiling Fans:
Cooling
Heatin[X]
Jan r [ ] Feb': `
Jan [X] Feb,
[ j Mar
[X] Mar
E
Apr
Appr
May
May
[Xj Jun
] Jun
X Jul
f Jul
Aug ''
IXIAu
Sepp
rl Sep
r.`
Oct
Oct
W
Nov
W Nov'
Dec
XDec
Ver [[ l]
Jan [ ] Feb•
[[�X]] Mar'
[xl
A r [
Ma
E ].Jun
[ Jul
Aug
Se
Oct
X Nov
[ Dec
Thermostat Schedule: HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
.:
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH).
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
6/18/2014 9:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6
Zlt
- FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method .
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT -- SECTION.. SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
/
leakage report or visually verify Table 402.4.2.
v
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
l
electric heat must prevent supplemental heat when compressor can
L/
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R 2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
V
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
IJIA
site recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 5.03.2.3. Equipment efficiency verification required.. Special
equipment
occasion cooling or heating capacity requires separate system or
V
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
6/18/2014 9:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6