Loading...
HomeMy WebLinkAboutEnergy Efficiency CoderFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR'BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Standard Pacific RB Stamford Lot 32 Builder Name: Standard Pacific Homes Street: 15329 N,W 1' t Permit Office: St. Lucie City, State, Zip: Port St. Lucie , FL , Permit Number: Owner: Standard Pacific Homes Jurisdiction: Design Location: FL, Fort Pierce WT- 32 1. New construction or existing New (From Plans) 9. Wall Types (3971.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 3646.00 ft2 b. Frame - Wood, Adjacent R=11.0 325.43 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (3518.0 ,sgft.) Insulation Area a. Under Attic (Vented) R=38.0 3518.00 ft2 6. Conditioned floor area above grade (ft2) 3518 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(965.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AC 1 First Floor 6 640 a. U-Factor: Dbl, U=0.60 472.06 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.59 288.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a. Central Unit 57.0 SEER:15.00 c. U-Factor: Dbl, U=0.77 136.00 ft2 SHGC: SHGC=0.22 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 68.99 ft2 a. Electric Heat Pump 56.0 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 8.469 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (3518.0 sqft.) Insulation Area EF: 0.910 a. Slab -On -Grade Edge Insulation R=0.0 3518.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.274 Total Proposed Modified Loads: 47.48 PASS Total Standard Reference Loads: 65.81 I hereby certify that the plans and specifications covered by Review of the plans and Sr`fT6' this calculation are in compliance with the Florida Energy specifications covered by this 0ollE 1• Digitally signed by Chris Wildroudt Code. DN: cn=Chris Wildroudt, c=US, Chris o=Engineered Air, LLC, ou=New calculation indicates compliance p with the Florida Energy Code. `! '%fY "- nrru Construction Sales and PREPARED BY:-Enginerring-- Before construction is completed DATE: I �d �OUCI-t ccm�il=ch!isw �noineeredairuo. this building will be inspected for "wwr O Date: 2014.06.18 09:15:16-04'00'{ compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Cod COD WT~� OWNER/AGENT: -BUILDING OFFICIAL: DATE: rJZ-71 IYC DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Heat sys #1 may be undersized. Size of 56.0 was increased to 69.2 for simulation. Please review the Manual J8 report. 6/18/2014 9:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 __. .. ' .. PROJECT Title: Building Type: Owner: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Standard Pacific RB Stamford User Standard Pacific Homes 1 Standard Pacific Homes - St. Lucie Single-family New (From Plans) Bedrooms: 4 Conditioned Area: 3518 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: Whole House Fan: Address Type: Lot # Block/SubDivision: PlatBook: Street: County: City, State, Zip: Lot Information 32 Riverbend St. Lucie Port St. Lucie , FL, CLIMATE V Design Location TMY Site IECC Design Temp Zone 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Block1 3518 37710.1093 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 AC 1 First Floor 3518 37710.1104 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio AC 1 First Floor 372 ft 0 3518 ft2 __-_ 0 0 1 ROOF V # Type Materials Roof Gable Roof Area Area Color Solar Absor. SA Emitt Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Barrel tile 3934 ft2 - 0 ft2 Medium 0.65 No 0.9 No 0 26.6 ATTIC / r V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 3518 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) AC 1 First Floor 38 '3518 ft2 0.11 Wood 6/18/2014 9:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 ._..• WALLS Adjacent Wall lypeSpace: - Cavity _ P Width Height Ft �nFt In Area Sheathing Framing -Val-le Fraction Solar Below at,��r r� ° _ 1 E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 13 0 10.67 0 138.7100 0.4 0 0.4 0 2 E Exterior Concrete Block - Int InsAC 1 First Flo (4.1 10 0 10.67 0 106.6999 0.4 0 0.4 0 3 -'E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 13 0 10.67 0 138.7100 0.4 0 0.4 0 _ 4 E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 12 0 10.67 0 128.0400 0.4 0 0.4 0 5 S Exterior Concrete Block - Int InsAC 1 First Flo 4.1 80 0 10.67 0 853.5999 0.4 0 0.4 0 6 S Exterior Concrete Block - Int InsAC 1 First Flo 4.1 13.5 0 10.67 0 144.0449 0.4 0 0.4 0 _ 7 . W Exterior Concrete Block - Int InsAC 1 First Flo 4.1 34 0 10.67 0 362.7799 0.4 0 0.4 0 8 W Exterior Concrete Block - Int InsAC 1 First Flo 4.1 20 0 12.67 0 253.3999 0.4 0 0.4 0 9 N Exterior . ' Concrete Block - Int InsAC 1 First Flo 4.1 14 0 10.67 0 149.3800 0.4 0 0.4 0 10 N Exterior Concrete Block - Int InsAC 1 First Flo 4.1 24 0 10.67 0 256.0800 0.4 0 0.4 0 11 N Garage Frame - Wood AC 1 First Flo 11 8 0 10.67 0 85.36000 0.4 0.4 0 12 W Garage Frame - Wood AC 1 First Flo 11 6 0 10.67 0 64.02000 0.4 0.4 0 13 W Exterior Concrete Block - Int InsAC 1 First Flo 4.1 18 0 10.67 0 192.0599 0.4 0 0.4 0 _ 14 N Exterior Concrete Block - Int InsAC 1 First Flo 4.1 50 0 10.67 0 533.5 ft2 0.4 0 0.4 0 15 S Exterior Concrete Block - Int InsAC 1 First Flo 4.1 6 0 10.67 0,, 64.02000 0.4 0 0.4 0 16 E Garage Frame - Wood AC 1 First Flo 11 16.5 0 10.67 0 176.0550 0.4 0.4 0 17 S Exterior Concrete Block - Int InsAC 1 First Flo 4.1 12 0 10 0 120 ft2 0.4 0 0.4 0 18 E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 20.5 0 10 0 205 ft2 0.4 0 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated AC 1 First Flo None 0.6 2.67 0 8 0 21.36 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V/ # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Double Yes 0.77 0.22 48 ft2 23 ft 0 in 2 ft 0 in None None 2 E 1 Metal Low-E Double Yes 0.4 0.31 21.28000 23 ft 0 in 2 ft 0 in None None 3 E 2 Metal Low-E Double Yes 0.77 0.22 48 ft2 13 ft 0 in 2 ft 0 in None None 4 E 3 Metal Low-E Double Yes 0.6 0.31 16.17000 6 ft 0 in 2 ft 0 in None None 5 E 4 Metal Low-E Double Yes 0.77 0.22 40 ft2 8 ft 0 in 2 ft 0 in None None 6 S 5 Metal Low-E Double Yes 0.6 0.31 116.9783 1.33 ft 0 i 2 ft 0 in None None 7 S 5 Metal Low-E Double Yes 0.6 0.31 22.68000 1.33 ft 0 i 2 ft 0 in None None 8 S 5 Metal Low-E Double Yes 0.6 0.31 9.180000 1.33 ft 0 i 2 ft 0 in None None 9 S 6 Metal Low-E Double Yes 0.59 0.32 80 ft2 18 ft 0 in 2 ft 0 in None None 10 W 7 Metal Low-E Double Yes 0.6 0.31 116.9783 1.33 ft 0 i 2 ft 0 in None None 11 W 8 Metal Low-E Double Yes 0.59 0.32 128 ft2 12 ft 0 in 4.67 ft 0 i None None 12 W 8 Metal Low-E Double Yes 0.4 0.31 24.88439 12 ft 0 in 1 ft 0 in None None 13 N 9 Metal Low-E Double Yes 0.59 0.32 80 ft2 18 ft 0 in 2 ft 0 in None None 14 N 10 Metal Low-E Double Yes 0.6 0.31 22.68000 9 ft 0 in 2 ft 0 in None None 15 W 13 Metal Low-E Double Yes 0.6 0.31 58.48919 1.33 ft 0 i 2 ft 0 in None None 16 N 14 Metal Low-E Double Yes 0.6 0.31 27.34560 1.33 ft 0 i 2 ft 0 in None None 6/18/2014 9:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 :. WINDOWS Orientation shown is the entered, Proposed orientation. / V ' r # - Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Area Depth Separation Int Shade Screening 17 18 19 20 21 22 N '14 Metal N 14 Metal N " 14 Metal N 14 Metal S 15 Metal S 17 Metal Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes 0.6 0.31 38.99279 1.33 ft 0 i 2 ft 0 in None 0.6 0.31 9.180000 1.33 ft 0 i 2 ft 0 in None 0.4 0.31 16.17000 1.33 ft 0 i 2 ft 0 in None 0.4 0.31 6.652800 1.33 ft 0 i 2 ft 0 in None 0.6 0.31 13.67280 1.33 ft 0 i 2 ft 0 in None 0.6 0.31 19.71199 2 ft 0 in 1 ft 0 in None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 660 ftz 660 ftz 72 ft loft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess 0.000500 4613.8 253.29 476.36 0.3650 7.3410 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF: 8.5 56 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 57 kBtu/hr 1710 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.91 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS # --- Supply - --- Return -- Air Percent Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF HVAC # Heat Cool 1 Attic 6 640 ftz Attic 160 ft' Default Leakage AC 1 First F (Default) (Default) % 1 1 6/18/2014 9:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 -' :TEMPERATURES Programable Thermostat:'Y - ' - Ceiling Fans: Cooling Heatin[X] Jan r [ ] Feb': ` Jan [X] Feb, [ j Mar [X] Mar E Apr Appr May May [Xj Jun ] Jun X Jul f Jul Aug '' IXIAu Sepp rl Sep r.` Oct Oct W Nov W Nov' Dec XDec Ver [[ l] Jan [ ] Feb• [[�X]] Mar' [xl A r [ Ma E ].Jun [ Jul Aug Se Oct X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 .: PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH). AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 6/18/2014 9:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 Zlt - FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method . MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT -- SECTION.. SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope / leakage report or visually verify Table 402.4.2. v Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental l electric heat must prevent supplemental heat when compressor can L/ meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R 2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent V to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from IJIA site recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 5.03.2.3. Equipment efficiency verification required.. Special equipment occasion cooling or heating capacity requires separate system or V variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 6/18/2014 9:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6