Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type01432.0 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - lnt Insul, Exterior R=4.1 1224.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. is this a worst case? Yes 11. Ceiling Types (1783.0 sgft.) Insulation Area 6. Conditioned floor area above grade (ft') 1753 a. Under Attic (Vented) b. Knee Wall (Vented) R=30.0 1753.00 ftz R=19.0 30.00 ftz Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(151.4 sgft.) Description Area 12. Ducts R ft2 a. U-Factor: Sgl, U=1.02 111.36 fE2 a. Sup: Attic, Ret: Attic, AH: Attic 6 195 SHGC: SHGC=0.29 b. U-Factor: SgI, U=1.11 40.00 ft2 SHGC: SHGC=0.27 13. Cooling systems kBtu/hr Efficiency c- U-Factor. N/A ft2 a. Central Unit 34.8 SEER:15.00 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. 14. Heating systems k$tu/hr Efficiency Area Weighted Average SHGC: 0.285 a. Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor(AVG) NIA ft2 SHGC(AVG): NIA 15. Hot water systems 9. F1oorTypes (1753.0 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features EF: 0.970 b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.086 Total Proposed Modified Loads: 49.38 Total PASS Baseline Loads: 50.69 I hereby certify that the plans and specifications covered by this Review of the plans and -Stu calculation are in compliance with the Florida Energy specifications covered by this - Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: DATE: 1-12-2021 Before construction is completed r� this building will be inspected forr compliance with Section 553.908 I hereby certify that this building, as designed, is in ompliance with the Florida Energy Florida Statutes. .'j;0�, CodeWE OWNER/A BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6 Ft7RM Rdr15_9r19n IKIDI IT CI IMAA Aov i+u Cntll 1Qr r�Gvwml PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stones: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 5o 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft2 ___ 0 1 0 2Slab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 ___ 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH . 8 ft 0 56 ft2 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft- 0 1 0 _ 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 ft2 0 1 0 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6 rUKM K4Ub-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ___ 0 1 0 7SIab-On-Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN lift 0 209 ft2 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 it 0 50 ft' 0 1 0 10Slab-On-Grade Edge Insulatio HALL 1 it 0 25 ft2 0 ___ 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC / V Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area - Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 112 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood 13 Knee Wall (Vented) DINING/GREAT 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below u 1 NE=>SW Exterior Concrete Block- Int InSCIIASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.3 0 2 SW=>NE Exterior Concrete Block - Int InsUASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 3 NW=>SE Exterior Concrete Block - Int lnsdnASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 IKIPI IT RI IMMAPV rluGrld-1 ICT OCOnOT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 4 NE=>SW Exterior Concrete Block - Int Insd1IASTER BA 4.1 8 0 8 0 64.0 ft' 0 0 0.3 0 5 NE=>SW Exterior Concrete Block - Int Insul M. BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.3 0 6 NE=>SW Exterior Concrete Block - Int InsBEDROOM 2 4.1 12 0 8 0 96.0 ft' 0 0 0.3 0 7 SW=>NE Exterior Concrete Block- Int InsQINING/GRE 4.1 30 0 8 0 240.0 ft- 0 0 0.3 0 8 NW=>SE Exterior Concrete Block - Int InsGINING/GRE 4.1 20 0 8 0 160.0 ft' 0 0 0.3 0 9 SW=>NE Exterior Concrete Block- Int InsulKITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.3 0 _10 NE=>SW Exterior Concrete Black- Int Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.3 0 11 SE=>NW Exterior Concrete Block - Int Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.3 0 12 SW=>NE Exterior Concrete Block- Int Insul FOYER 4.1 1 0 8 0 8.0 ft` 0 0 0.3 0 _13 NE=>SW Exterior Concrete Block - Int InsBEDROOM 3 4.1 13 0 8 0 104.0 ft' 0 0 0.3 0 _14 SW=>NE Exterior Concrete Block- Int lnsBIEDROOM 3 4.1 1 0 8 0 8.0W 0 0 0.3 0 _15 N=>S Garage Frame - Wood BEDROOM 11 26 8 208.0 ft' 0.23 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated FOYER None .39 3 3 6 8 21.7ft- WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.02 0.29 Y 32A ft' 1 ft 0 in 1 it 4 in Drapes/blinds Exterior 5 2 NE= SW 5 Metal Low-E Single Yes 1.02 0.29 Y 6.9 T 1 ft 0 in 1 ft 4 in None None 3 NE=>SW 6 Metal Low-E Single Yes 1.02 0.29 Y 16.2 T 1 It 0 in 1 ft 4 in None None 4 SW=>NE 7 Metal Low-E Single Yes 1.02 0.29 Y 39.81E 1 ft 0 in 1 ft 4 in None None 5 NW=>SE 8 Metal Low-E Single Yes 1.11 0.27 Y 40.0 ft° 8 It 0 in 1 ft 4 in None None 6 NE=>SW 13 Metal Low-E Single Yes 1.02 029 Y 16.2 ft7 It 0 in 1 ft4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 fF 26 ft 8 It 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 64.12 120.37 .0902 5 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPART HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singi SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft= DUCTS / — Supply -- -- Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 195 ft- Attic 55 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl(e Ceiling Fans: �Thermostaf[t:lN Heat ng IXI Jan (X] Feb Venting 71 [X1 Mar 4 ti i„I Apr € May fJC1 Jun I 1 Jul fX1 T 1 Aug jX� [ ] Sep Oct Nov Nov Dec Dec [I 11 Jan ([ ]] Feb [[�X1] Mar 111^^^lll May Jun [ j Jul (] Aug [ j Sep Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 58 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft- 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 Ibs/sq.ft. ft' ft 0.3 MASTER BATH Default(8 lbs/sq.ft. ft' ft 0.3 M. BATH Default(8 lbs/sq.ft. ft' ft 0.3 LAUDRY Default(8 lbs/sq.ft. W ft 0.3 BEDROOM2 Default(8 lbs/sq.ft. ft' ft 0.3 DINING/GREAT R Default(814s/sq.ft. ft' ft 0.3 KITCHEN 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Softvrare Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(8 lbs/sq.ft. ft' ft 0.3 HALL Default(8 lbs/sq.ft. ft' ft 0.3 FOYER Default(8 lbsts.ft. ft' ft 0.3 BEDROOM 3 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. x Owner: Jurisdiction: w Design Location: FL, Fort Pierce = U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. Knee walls shall be with a material having a thermal resistance of R-3 sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors (including The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to above -garage maintain permanent contact with the underside of and cantilevered subfloor decking, or floor framing cavity insulation floors) shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind nininn and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. n avviuvii, hjspvtlu[j u4 lu, wens snail oe in aOCOr°ance win the provisions or VC huu. 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 208.00 fF c. N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? Yes 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area (ft2) 1753 b. Knee Wall (Vented) R=19.0 30.00 ft2 7. Windows" Description Area c. N/A R= ft= a. U-Factor: Sgl, U=1.02 111.36 W 12. Ducts, location & insulation level R 112 SHGC: SHGC=0.29 a. Sup: Attic, Rat: Attic, AH: Attic 6 195 b. U-Factor: Sgl, U=1.11 40.00 ft2 SHGC: SHGC=0.27 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor. N/A ft2 SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2.850 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.285 8. Skylights Description Area 15. Hot water systems a. U-FactogAVG): N/A ft= a. Electric Cap: 40 gallons SHGC(AVG): N/A EF: 0.97 9. Floor Types Insulation Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft= None b. N/A R= ft2 Credits (Performance method) None c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant futures. Builder Signature: Date: �\ Address of New Home: A \-.Ck City/FL Zip: �%t • `�( �� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 ® Project Summary Job: wrigi7tsof# Entire House By. QUICK CALCS, INC. 317 SL LUCE LN., Fr. PIERCE, FL 34946 Phone: 772-466-6799 Fax T72-466-6796 Email: OUICKCALCS@AOL.COM Proiect Information For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Notes: Design Information Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21542 Btuh Structure 16420 Btuh Duds 6191 Central vent (0 cfm) 0 Btuh Btuh Duds Central vent (0 cfm) 9337 0 Btuh Bluh none (none) Humidifigtion 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27734 Btuh Use manufacturer's data n Infiltration Rate/sw ngg multipplier Equip mentsensbleload 0.95 24470 Btuh Method Simplified Construction quality Average Latent Cooling Equipment Load Sizing Fireplaces 0 Structure 2495 Btuh Duds 2546 Bluh Central vent (0 cfim) 0 Btuh Heatingg Area Cool' ngg (none) (112) 1753 1753 Equipment latent load 5041 Btuh Volume(fla) 16478 16478 AirchanggesAlour 0.38 Equiv.AVF 104 0.20 Equipment Total Load (Sen+Lat) 29511 Btuh (din) 55 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536M030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Airflowfador Static pressure Space thermostat Capacity balance point = 36 OF 8.5 HSPF 34600 Btuh@47-F 1160 om 0.042 cfm/Btuh 0 in H2O Backup: Input=7kW, Output= 23009 Btuh, 100 AFUE Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Sensible cooling 24360 Btuh Latentcooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cirri Airflowfador 0.045 cfin/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.84 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrighlsoft° 2021-Jarv1213:18:18 RigN.Sdte@Uiwml20l9l9.021 RSL[08101 -.Doa rtslWdgHm@HVAQWYNNE-7HEWINDSORnp Calc=MJ8 FrortDoorfaces:N Pagei .4CCa F� wrightsoft Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE UN., Fr. PIERCE, FL 34W Pinne: 772-466-6799 Fax 772-466-6796 Emil: QUICKC4LCS ,AOL.COM 1 Roam name Entire House BEDROOM 2 Faposed wail 207.6 ft 41.0 ft 3 Room height 9.4 ft d 9.4 4 heaV=l 4 Room dimensions 14.0 x 20.0 ft 5 Room area 1753.0 ft 280.0 f Ty Construction U-value Or HTM Area s (fn Load number (BluladMF) (BtuW or perimeter (ft) (BWh) or perimeter (ft) (BWh) Heat Cool Grog WPS Heat Cool Grog NrPS Heat Cool 6 V[13A-4= 0.143 n 4.00 2.55649 596 2386 1517 66 66 263 - 167 IL -GC, tAclom 1270 In 3556 34.77 15 0 533 522 0 0 - 0 0 4A5-20m 0.770 n 2156 19.31 38 0 815 730 0 0 0 - 0 W 13A-0acs 0.143 ne 4.00 2.55 27 27 106 68 0 0 0 0 11 V�1 13A o s 0.143 a 4.00 2.55 141 100 400 255 0 0 0 0 �C 1Aa1om 1270 a 35.56 87.06 20 1 711 1741 0 0 0 0 �D 11D0 0.390 a 1052 11.31 21 21 229 238 0 0 0 0 W 13A4= 0.143 se 4.00 Z55 27 27 106 68 0 0 0 0 VI/ �C 13A4= 0.143 s 4.00 2.55 536 530 2121 1349 188 188 753 479 1Aclom 1270 s 3556 34.77 6 6 213 209 0 0 0- 0 13A4= 0.143 w 4.00 255 320 255 1022 649 132 108 432 275 1Ac1om 1270 w 35.56 54.53 12 1 415 636 12 1 415 636 1Actom 1270 w 35.56 54.53 12 1 427 654 12 1 427 654 4AS2om 0.770 w 2156 45.63 41 2 880 1862 0 0 0 0 P 12C-09M 0.091 - 255 128 254 254 647 326 0 0 0 0 C 16AJOmd 0.032 - 020 2.32 1753 1753 1571 4067 280 280 251 650 F 22A-tpl 0.989 27.69 0.00 1753 208 5748 0 280 41 1135 0 6 c)AEDexalrson 397 488 Envelope loWgain 18331 15285 3676 3349 12 a) Infiltration 3211 905 729 205 b) Room ventlaion 0 0 0 0 13 Internal gains: O=panls@ 230 1 230 0 0 Applanrn.9other 0 0 SubWW (Ilnes6 W 13) 21542 16420 4405 3554 Lmexfemalload 0 0 0 0 Leestransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subfofal 21542 16420 4405 3554 F.15 Dudloads 29% 57% 6191 9337 29^/ SPA 1266 2021 Total room load 27734 25757 5671 5575 Airrequired(dm) 1160 1160 231 251 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 'T w 2021-Ja 1213:18:18 RigHSute@Uriversal 201919.021 RSU08101 Page 1 ...Doamerts\WdgtfsoftHUAQWYNNE-THEWINDSORnp Calc=MJ8 FrorfDuorfaces:N p-wrightsoft° Right-J® Worksheet Job: Entire House per: QUICK CALCS, INC. By. 3175T. LUCIE LN.,Fr. PIERCE, FL 34946 Phone: 772-066-6799 Fax 772-466-6796 Ena7: QUICKCALCSCAOL.COM 1 Raxn WIC M4STERBATH 2 mall 0 ft 90 ft 3 Room height 9.4 ft heakod 9A ft heaGmd 4 Rcom tlimensaa 7A x 9D ft 7A x 90 ft 5 Roomarea 630 IF 63A T Ty Coratrurdon U-value Or HTM Area (IF) Load number (BWhW-n (Bbih" or peti fir (ft) (Bluh) or penmeW (it) (BWh) Heat Cool Gross WP5 Heat Cod Gros NIPS Heat Cool 6%r_l13A4acs 0.143 - n 4A0 255 - 0- - 0 0 0 0 0 - 0 0 1Ac1om 12M n - 3558 34.77 - 0 0 0 0 0 0 - 0 0 4A5-2om 0.770 n 21M 1931 0 0 0 0 0 0 0 0 W 1344as 0.143 m 400 255 0 0 0 0 0 0 0 0 11 13A4= - 0.143 e- 400 21% 0 0 0 0 0- 0 0 0 tAclam 12M a 3556 87A6 0 0 0 - 0- - 0 0 0. 0 11DO 0.390 a 1092 1131 0 0 - 0 0 0 -- 0 0 0 W 13AAcm 0.143 se 4A0 2.55 0 0 0 0 0 0 0 0 13A4= 0.143 - s 400 - 255 0 0 0 0 85 85 `- `339 215 1A- Icm 1270 s 35M 34.77 - .0 0 0 - 0 O- 0 0 0 13A4=0.143 w 4DO 255 0 0 0 0 0 0 0 0 1Aciom 1270 w 3556 54M 0 0 0 0 0 0 .0 0 1A.dw 1270 w 35M 5453 0 0 0 0 0 0 0 0 4A52om 0.770 w 2155 45.63 0 0 0 0 0 0 0 0 P 12C-Ow OA91 -- 12S5 128 0 0 0 -0 0 0 0 0. G 16-30md OA32 - 0.90 232 63 63 56 146 63 63 56 146 F - 22AV1 0989 - 2759 000 63 0 -0 0 63 9 249 - 0 6 c)AEpemusion -10 -28 Ernmlope losslgain 56 136 6" 334 12 a) Infiltration 0 0 160 45 b) Rcomverdation 0 0 0 0 13 Inlemal gains O=pants@ 230 0 0 0 0 Applia0osloftar 0 0 Subbtal(Iines6b13) 56 136 W4 379 Lesea&malload 0 0 0 0 Lestarder 0 0 0 0 Redistribution 0 0 14 Subtotal 56 136 804 370 15 Dudloads 29%. 57% 16 77 29% 57% 231 216 ToW room load 73 214 1035 595 Air required (dm) 3 10 43 27 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed Aa- 2021Ja 1213:18:18 l.C�A RigHSEWINDersalp Cale.= RSrortD Paget ...Dorurzrt;\Wn9�ftHVA(TWYNNE-THE WINDSOFLrp Calc=M18 FrortCowfa�s N wrightSoft° RighW@ Worksheet Job: Entire House Dale: QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE. FL 34946 Prone: 772466-6799 Fax A2466£796 Erred: QUICKCALCS@AOL.COM 1 Room name MBATH KITCHEN 2 Eposed wall 8.0 It 8A it 3 Room height 9.4 ft heaV=l 9.4 It hest4ccol 4 Room dimensions 7.0 x 8.0 It 1.0 x 172.0 it 5 Room area 56.0 fF 1720 IF Ty Construction U-value Or HTM Area number (a hdk*F) (BNh4F) or perime(it) (BNh) or�perimeter (ft) (B1uh) Heat Cool Gross N/P/S Heat Cool Gross NIPS Heat Cool 6 1344ocs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 T 1Ac1on 1270 In 3556 3477 0 0 0 0 0 0 0 0 11---CG 4AS-2om 0.770 n 2156 19.31 0 0 0 0 0 0 0 0 W 13A4os 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 yr 13A4a¢ 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 a 3556 87.06 0 0 0 0 0 0 0 0 II—DG 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W 13A4os 0.143 se 4A0 2.55 0 0 0 0 0 0 0 0 W im4oa 0.143 s 4.00 255 75 69 277 176 0 0 0 0 �G 10-clom 1270 a 3556 3477 6 6 213 209 0 0 0. 0 13A4os 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1A-clom 1270 w 35M 54.53 0 0 0 0 0 0 0 0 1Ac1om 1270 w 3556 6453 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 21M 45.63 0 0 0 0 0 0 0 0 P 12C-09m 0.091 2-95 1A 0 0 0 0 75 75 192 96 C 16A-3omd 0.032 - 020 2.32 56 56 50 130 172 172 154 399 F 22A-411 0.989 - 27.69 0.00 56 8 222 0 172 8 222 0 6 c)AEDeuursion -38 J4 Envelope loss/gain 762 477 567 462 12 a) InfIb-lion 142 40 0 0 b) Room tenllation 0 0 0 0 13 Intemal gains O=pants@ 230 0 0 0 0 Applianossiother 0 0 Subtotal(lines6to13) 904 517 567 462 I-MeADmalload 0 0 0 0 L.esstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 904 517 567 462 15 Dud loads 29% 570/c 260 294 29% 57% 163 263 Total room load 1164 811 730 725 Air required(cfrn) 49 37 31 33 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed , wrlg`htsofC- 2021-JaM213:18:18 RigttSute®lhiversa1201919.021 RS W8707 Page 3 ...Dow rlslWdghbDftHVAQWYNNE-TFIEWINDSORnp CaIc=MJ8 FrorlDoorfaces:N AL rpr wrightSoft RighWO Worksheet Boa. Entire House °abe1 QUICK CALCS, INC. By. 317 ST. LUCIE LN., FL PIERCE, FL 34946 Prow: 772-466-6799 Fax 772-46fi-6796 Emil: QUICKCALCS@ OL.COM 1 2 Room name BATH Bm.6 3 6pomwall Room height 5.0 It 425 ft it 4 Room dimensom 9.4 t heatlmol 9.0 x 5.0 It 9.4 itheatkool 5 Room area 95A T 1.0 x 204.0 it 204.0 fl' Ty Construction U-velue Or HTM Area Load Load number (BIuhMP-°F) (BWh#F) or perimeter (it) (BWh) o orperim� (ft) (Btuh) Heat CCcl Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VI! IL- 13AAa tAclom 0.143 n 4.00 2.55 47 47 188 120 132 132 527 335 1270 n 3556 34.n 0 0 0 0 0 0 0 0 4M2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 11 W V 134-4as 13A-4= 0.143 0.143 ne a 4.00 4.00 2.55 2.55 0 0 0 0 0 27 27 106 68 1Ac1om 1270 a 3556 87.06 0 0 0 0 0 0 0 85 20 65 259 1 164 I�DG 11D0 0.390 a 10.92 11.31 0 0 0 0 0 711 0 1741 W 13A-0a¢ 0.143 se 4.00 255 0 0 0 0 27 27 0 106 0 68 t-G im4ccs 0.143 s 4.00 2.55 0 0 0 0 132 132 527 335 1Ac1om 1270 s 35.56 3477 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 0 1Ac1om 1270 w 3556 5453 0 0 0 0 0 0 0 IA-c1om 1270 w 3556 5453 0 0 D 0 0 0 0 4A5-2om 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 0 P 12C4kw 0.091 255 128 0 0 0 0 0 0 0 C F 16A30md 22A-yl 0.032 0-%9 - 0.90 2.32 45 45 40 104 204 204 183 0 473 - 27.69 0.00 45 5 138 0 204 43 1179 0 6 C)AM e=raon -17 -99 Envelope loss/gain 367 207 3599 3085 12 a) Infiltrafion 89 25 758 214 b) Room venfilafion 0 0 0 0 13 Internal gairs: Ooypants@ 230 0 0 0 0 Applianoss/oftw 0 0 Subbial(firies6to 13) 456 232 4357 3299 Lesse)*mal load 0 0 0 0 Lesstran4er 0 0 Redistribution 0 0 0 0 14 Submlal 456 232 4357 3299 15 Ductloads 2911. 57% 131 132 29"/0 57% 1252 1876 Thal room load 587 364 5609 5175 Airrequimc](rim) 25 16 235 233 Calculadons approved byACCAto meet all requirements of Manual J 8th Ed .`_^W� ~� � .9A RigkSrite®llriversa1201919.022021-,1rv1213:1a:18 1 RSU08101 Page4 ...Doo &e W6ghtmtWAMWVNNE-THEWINDSORnp Calc=NW FrordDoorfaces:N +}� wrightsoft- Right-J® Worksheet Job: Entire House °fit QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE. FL 34946 Phore: 772-466-6799 Fax T72-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name ENTRY LAUNDRY 2 Exposed wall 18.0 ft 13.0 ft 3 Room height 9.4 ft heaVcDol 9.4 ft heaticnol 4 Room dimensons 1.0 x 92D ft 7.0 x 6.0 ft 5 Room area 92.0 W 42.0 W Ty Construction U-value Or HTM Area Load Area (ft� Load number (BWh4F-°F) (BWh4n or perimeter (ft) (BWh) or perimeter (ft) (SWh) Heat Cool Gross NIPS Heat Cool Gros NIPSS Heat Cool 6 yf 13A-4ors 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1Aciom 1270 n 3556 34.77 0 0 0 0 0 0 0 0 11--1C' 4A5-2om 0.770 n 21.66 1931 0 0 0 0 0 0 0 0 w 13A4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 11 `1�1 13A4o s 0.143 a 4.00 255 56 35 142 90 0 0 0 0 ---G tAclom 1270 a 35M 87.06 0 0 0 0 0 0 0 0 �D 11D0 0.390 a 1092 1131 21 21 229 238 0 0 0 0 w 13AAots 0.143 se 4A0 2.55 0 0 0 0 0 0 0 0 t—G 13A4o s 0.143 s 4.00 255 0 0 0 0 56 56 226 144 1Aciom 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13A4o s 0.143 w 4.00 255 0 0 0 0 0 0 0 0 1Aciom 1270 w 3556 54.53 0 0 0 0 0 0 0 0 1A-dom 1270 w 3&% 54.63 0 0 0 0 0 0 0 0 4AS2om 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 P 12C-0sN 0.091 - 255 128 113 113 287 145 66 66 168 84 C 16A-30md 0.032 - 090 232 92 92 82 213 42 42 38 97 F 22A-1PI 0.989 - 27.69 0.00 92 18 498 0 42 13 360 0 6 c)AEDe rson -49 -24 Envelope losV/Wn 1239 637 791 301 12 a) Inflradon 107 30 107 30 b) Roomventlation 0 0 0 0 13 internal gains: O=pants@ 23 00 0 0 0 Appliancesother 0 0 Subtotal(lines6m 13) 1346 667 898 331 Lesebemalload 0 0 0 0 Lestranser 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1346 667 898 331 15 Duct loads 29% 57% 387 379 29-A 57/6 258 188 Total room load 1733 1047 1156 520 Airreguired(dm) 72 47 48 23 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed 2021-Jarv1213:18:18 A LP. RigHSutsOUriv ml201919.021 RSU08101 Page s ...Doa rtAWdgftAHVAaWYNNE-THEWINDSORnp Calc=MlB Frord Doorfces:N wrightsoft' Right-J® Worksheet .lob: Entire House Date: QUICK CALCS, INC. By 317 ST. Ll10E LN, Fr. PIERCE, FL 34946 Plow 772466-6799 Fax772466-6796 Email: QUICKOALCS@AOL.COM 1 Room name GREATANNG Room7 2 Exposed%%Wl SOD 1 13.0 It 3 Rcom height 9.4 H heWood 9A 1t heaftol 4 Room dimensons 1.0 x 567.0 H 130 x 13.0 It 5 Room area 5670 f 169.0 1R TY ConsWrfion U-value Or HTM Area (ft2) Load Area Load number (BluhdK*19 (Bbift" or perimeter (R) (Bluh) or perimeter (la fth) Heat Cool Gros N/P/S Heat Cool Gros NrPIS Heat Cool 6 1Q/ 13A4= 0.143 n 4.00 255 282 244 978 622 122 107 429 - 273 1Aclonn 1270 n 35M 34.77 0 0 0 0 15 0 533 - 522 4AS2om (1770 n 21M 1931 38 - 0 815 730 0 0 0. 0 W 13A4o s 0.143 ne 4A0 2.55 0 0 0 0 0 0 0 0 11 VQ 13A-0as 0.143 a 4A0 2.55 0 0 0 0 0 0 0 - 0 I�DC 1ACNan 1270 -e 3556 97.06 0 0 0 0 0 0- - 0 0 11DO 03SO -e 1092 - 1131 _ 0 0 0 -0 0 0 0 - 0 w 13A4or5 0.143 w 4.OD 255 0 0 0 0 0 0 0 0 w 13A4= 0.143 s 4A0 2M 0 0 - 0 0 0 0 - 0: - - 0 LG 1AtMan 1270 s 3556 34.77 0 0 0 0 0- 0 ' 0- 0 13A4= 0.143 w 4110 255 188 147 MS 375 0 0 0 0 1Ac1om 1270 w 35S 5453 0 0 0 0 0 0 0 0 tActan 12M w 3556 54M 0 0 0 0 0 0 0 0 4AS-2om 0.770 w 2156 45M 41 2 8w 1852 0 0 0 0 P ` 12C-096v OD91 - - 2.55 128 0 0 0 - 0 0 - 0 0 .0 C 16A-30md OA32 090 232 567 567 508 1315 169 169 151 392 F - 2" 0.989 - 27.69 0.00 567 50 1385 0 169 13 �360 0 6 c)AEDe=rsion 307 -100 Envelope lossWn 5154 5210 1474 1086 12 a) hiltration 8w 251 231 65 b) Roomeentilabon 0 0 0 0 13 htenalgaim Ooaipants@ 230 0 0 1 230 Applianoes(other 0 0 Subbtal(lines6to13) 6043 5461 1705 1381 Les edemal load 0 0 0 0 Lestransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 6043 5461 1705 1381 15 Ductloads 29°A 57% 1737 3105 29% 57% 490 785 Total mom load 7780 8566 2195 2167 Airrequired(dm) 325 386 92 98 Calculations approved bvACCAto meet all reauirements of Manual J 8th Ed --%-wtieS m 2021-JaM213:18:18 RigRSute®lkiwrwl201919A21 RSU08101AM Page6 ...Dow rts\WdgHmRHVAQWYNNE-T-EWINDSORnp Cale=M18 FrortDoorfaw&N -�1- wrightsoft® Duct System Summary Job: Date: Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Pfnre:772-466-6799 Fax 772-466-6796 Emil: QUICKCALCS@AOL.COM Project• • For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply/return available pressure Lowestfriction rate Actual airflow Total effective length (TEL) Heating 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in/100ft 1160 c6n 0 ft Supply Branch Detail Table Cooling 0 in H2O 0 in H2O 0 in H2O 0.000/0.000 in H2O 0 in/100ft 1160 cflTl Name Design (Btuh) Htg (cfm) Clg (Clm) Design FIR Diam (in) H x W (in) Dud Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 364 25 16 0 0 OX0 ShMt 0 0 BEDROOM c 2788 119 126 0 0 OX0 ShMt 0 0 BEDROOM2 h 2587 117 117 0 0 OX0 ShMt 0 0 BEDROOM2-A h 2587 117 117 0 0 OX0 ShMt 0 0 BEDROOM -A C 2788 119 126 0 0 0x0 ShMt 0 0 ENTRY h 1047 72 47 0 0 OX0 ShMt 0 0 GREAVDINING C 2855 108 129 0 0 OX0 ShMt 0 0 GREATIDINING-A C 2855 108 129 0 0 OX0 ShMt 0 0 GREATDINING-B C 2855 108 129 0 0 OX0 ShMt 0 0 KITCHEN c 725 31 33 0 0 OX0 ShMt 0 0 LAUNDRY h 520 48 23 0 0 OX0 ShMt 0 0 M. BATH h 811 49 37 0 0 OX0 ShMt 0 0 MASTERBATH h 595 43 27 0 0 OX0 ShMt 0 0 ROOm7 C 2167 92 98 0 0 OX0 ShMt 0 0 WIC C 214 3 10 0 0 OX0 ShMt 0 0 Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (dm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W Qn) Stud/Joist Opening (in) Dud Mat Trunk rb1 OxO 1160 1160 0 0 0 0 Ox 0 ShMt -*- wrightsoft' 2021.1an1213:18:19 I—:_, •.�+-� .A,-..uno., RigF[-SufeSUnversa1201919.02t RSU08101 ACCk Pagel ...mo r61Wdgft-oftHVAQWYNNE-THE WINDSORn.P C%Ic=MX Frok Caorfare . N