Loading...
HomeMy WebLinkAboutAPPROVED, New Duct Drawing UpdatedJob #: 1561 Performed by Chris Bateman for: Heath Residence TBD Kenwood Rd (Lot 11) Port St. Lucie, FL 34951 Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@aircalcs.com Scale: 1 : 120 Page 1 Right-Suite® Universal 2021 21.0.10 RSU29066 2021-Nov-30 16:50:00 ...Kenwood Rd (lot 11) PSL Prop.rup N Level 1 Garage Laundry Bed 2 Kitchen Hall Lin Bath Bed 3 Master Bed Wtr Clst His Hers Master Bath Family Room DR Foyer WIC 2 WIC 1 12 x 8 143 cfm 8 x 8 66 cfm 8 x 4 3 cfm8 x 4 19 cfm 10 x 10 141 cfm 8 x 8 96 cfm 8 x 8 96 cfm 10 x 10 155 cfm 10 x 10 155 cfm 8 x 4 27 cfm 10 x 6 55 cfm 10 x 10 119 cfm 10 x 10 119 cfm H/W 12 x 12 291 cfm 14 x 14 297 cfm 14 x 14 F F F 30 x 18 856 cfm 10 x 6 92 cfm 10 x 6 92 cfm 10 x 6 59 cfm 10 x 6 57 cfm 8 x 8 104 cfm 8 x 8 104 cfm 12 x 12 143 cfm DUCTS IN THE GARAGE AND H/W DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL, 1 INCH MINIMUM RIGID NONMETALLIC CLASS 0 OR CLASS 1 DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL HAVE NO 50 CFM 4"Duct 4"Exhaust Vent 120 CFM 6"Duct 6"Exhaust Vent 80 CFM 4"Duct 4"Exhaust Vent 10 "7 " 18 " 12 " 5 " 6 " 6 " 7 "12 " 7 " 12 " 6 " 6 " 4 " 5 "6 " 4 " 7 " 4 " 18 " 6 " 6 " 5 " 4 " 5 " 7 "