Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR, Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41442.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1250.00 ft2 b_ Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 2 d. NIA R= ft2 5. Is this a worst case? Yes 11, Ceiling Types (1476.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft2 6. Conditioned floor area above grade (ft2) 1446 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 7. Windows(141.3 sqft.) Description Area 12. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor: SgE, U=1.04 101.25 ft2 SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 ft2 13. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. 14. Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 0.284 a. Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap: 50 gallons 9. Floor Types (1445.5 sqft.) Insulation Area EF:0.970 a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 b. Conservation features b. WA R= ft2 None c. NIA R= ft2 16. Credits None Total Proposed Modified Loads: 44.57 GlasslFloor Area: 0.098 PASS Total Baseline Loads: 45.19 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this 1� n Code. calculation indicates compliance of ''' a• r with the Florida Energy Code. =,-ate:. •. PREPAR D Y' Before construction is completed DATE: '1'�02 this building will be inspected for compliance with Section 553.908 _} g 0 , I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Co �'flg,W OWNEW�F4N. ' BUILDING OFFICIAL: DATE. \ DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/12/2021 12:02 PM EnergyGaugei� USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INYU 1 5UMMAK7 l HLUKLI, I KtYUK I PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 It 0 301 ft2 ____ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 __ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 IF -_ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft2 ___ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft2 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 _- 0 1 0 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ____ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC / tr # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood 10 Knee Wall (Vented) GREAT/DINING 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>SW Exterior Concrete Block - Int InsuBEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 _2 SW=>NE Exterior Concrete Block - Int InsuBEDROOM 4.1 28 0 8 0 224.0 ft 0 0 0.4 0 3 NW=>SE Exterior Concrete Block- Int InsuBEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 5 NE=>SW Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _ 6 NE=>SW Exterior Concrete Block- Int Ins@EDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 7 SE=>NW Exterior Concrete Block - Int InsOEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 8 S=>N Exterior Concrete Block - Int InsBEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 9 SW=>NE Exterior Concrete Black - Int Ins8lEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block - Int Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 _11 SW=>NE Exterior Concrete Block- Int Insul ENTRY 4.1 1 0 8 0 8.0 11:2 0 0 0.4 0 12 SW=>NE Exterior Concrete Block - Int InsULAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 13 NE=>SW Exterior Concrete Block- Int InsLSREAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 _14 NW=>SE Exterior Concrete Block- Int InstOREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.4 0 DOORS # Omt Door Type Space Storms U-Value Width Height Ft In Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => chanced to Worst Case. Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 1.04 0.29 Y 32.9 ft' 1 ft 0 in 1 It 5 in Drapes/blinds 1.04 0.29 Y 6.9 ft' 1 It 0 in 1 ft 5 in None 1.04 0.29 Y 24.0 ft' 6 ft 0 in 1 ft 5 in None 1.04 0.29 Y 37.5 ft' 1 ft 0 in 1 ft 5 in None 1.11 0.27 Y 40.0 ft' 8 ft 0 in 1 ft.5 in Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.04 139.01 .1263 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None 1/12/2021 12:02 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply -- -- Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 175 ft2 Attic 65 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablr[e ThermostatJan: Ceiling Fans:Cooling ��N Heating Feb Jan Mar Apr rXI Jun [ ] Jul X] 4 ] Aug ICI f ] Sep [ j 0 ct 1 J Oct Nov Dec Vent [ j [ ] [ May Jun [ 1 Jul 11 Aug 11 Sep lxJ Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 ft 03 WIC Default(8 lbs/sq.ft. ft2 ft 0.3 M. BATH Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8lbs/sq.ft. ft2 ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 ENTRY Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default 81bs/s .ft. ft' ft 0.3 GREAT/DINING 1/12/2021 12:02 PM EnergyGauge& USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. - Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall re requirements q The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit Y 9 /soffit the insulation and any gaps in the air bon barrier shall be sealed. air shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage sepamflon Air sealing shall be provided between the garage and conditioned spac Ds. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids n In addition incnnMinn of In.. ...rill.. ..L..11 i- ., .._a.# .. •"V— .... ...tee —1— aria uc ui uewwauw rvluI OIV i/I VVIwVIIJ OI I Vu. 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. FT. PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192,00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 5. Is this a worst case? Yes 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1446.00 ft2 6. Conditioned floor area (ft2) 1446 b. Knee Wall (Vented) R=19.0 30.00 ft2 c. N/A R= ft' 7. Windows" Description Area a. SH U=0.2 101.25 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 175 SHGC::U-Fact SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 ft2 SHGC: SHGC=0.27 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ft2 SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.832 ft. a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.284 B. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric Cap: 50 gallons SHGC(AVG): N/A EF: 0.97 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2 Credits (Performance method) None b. N/A R= f[2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code coMpliant features. Builder Signature:-� Date: Address of New Home: 0,-Z,�"1 City/FL Zip: 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 12:02 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 Job: wrightsoft° Project Summary. Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Ptore: 772466-6799 Fax 772466-6796 Eceil: QUICKCALCS@lOL.COM Project Information For. WYNNE DEVELOPMENT CARLTON III, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grflb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19691 Ducts Btuh Structure 16785 Btuh 5900 Central vent (0 cfm) 0 Btuh Btuh Ducats Central vent (0 cfm) 8919 0 Bluh Btuh none Humidification 0 Btuh Blower e) 0 Btuh Piping Equipmentload 255911 Btuh Use manufacturers data n Infiltration Ratelswingg multiplier Equipment load 0.95 sensible 24418 Btuh Method Simplified Construction quality Average Latent Cooling Equipment Load Sizing Fireplaces 0 Structure 2065 Btuh Duds 2429 Bluh Central vent (0 cfm) 0 Btuh g Area (iF) He 60g 2 Coolin (none) Volume (fta) 14827 2 14827 Equipment latent load 4493 Btuh Airchanges/hour 0.38 Equiv.AVF (cfm) 94 020 49 Equipment Total Load (Sen+Lat) 28912 Bluh Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536A 030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 34 OF 8.5 HSPF 34600 Btuh @ 47-F 27 OF 1160 cm 0.045 CfmBtuh 0 in H2O Backup: Input=7kW, Output= 230G9 Btuh, 100 AFUE Make Carrier Trade CARRIERAIRCONDITIONING Cond 25HBC536A'030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Sensiblecooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160 dm Airflowfactor 0.045 cfTvBWh Static pressure 0 in H2O Load sensible heat ratio 0.85 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. �„ .w�..� 2o21Ja 1212U4'.36 .R.E.46 NE E GRAND CA LTON 1201919.=IV RS ro 1D Page 1 ...r6lWngtLsoRHUAgWYNNE-TFIE GRAND C4RLTON�1 CaIc=MIB FrorKDwrfaces: N wrightso r Right-JO Worksheet Job: Entire House Dab: QUICK CALCS, INC. BY. $17 ST. LUCIE LN.,FT.PIERCE, FL 34946 Phone: 772466-6799 Fa%772466-6796 Emil: QUICKCALCS5—AOL.COM i Room name Entm Houma BEDROOM 2 E 1762 ft 41.0 ft 3 heig Room height 93 ft d 8.0 ft heallo�ol 4 Room tlimensons 14.0 x 18.0 ft 5 Room area 1601.5 ft 252.0 1R Ty Consbuclion U-value Or HTM Area OF) Load Area(� Load number (BWh4R°F) (BWhdg or perimeter (ft) (Btuh) or perimeter (8) (BWh) Heat Cool Gros N/P5 Heat Cool Gras NIPS Heat Cool 61-3 13AA= 0.143 re 4A0 2.55 551 513 2055 130E 72 72 288 183 1Actam - 1270 re 35.56 70.43 38 0 1344 2662 0 0 - 0 0 v� 13A4ors 0.143 se 4.00 2.55 128 87 348 221 0 0 0 0 L—f 1A-c1w 1270 se 35.56 70.96 20 0 711 1419 0 0 0 0 71 �D 11DO 0.390 ce 10.92 11.31 21 21 229 238 0 0 0 0 w 13AA= 0.143 5 4.00 255 34 34 136 86 0 0 0 0 13A4ocs 0.143 sN 4.00 2.55 416 39D 1562 993 144 144 577 367 tAclom 1270 sv 3556 70.95 6 0 213 426 0 0 0 0 1Actom 1270 sv 355E 7D.95 20 0 711 1419 0 0 0 0 13A4as 0.143 nw 4.00 255 352 288 1151 732 112 88 354 225 1Ao1on- 1270 nw 3556 4524 12 0 415 528 12 0 415 528 1A-dorn 1270 rw 35.56 4524 12 0 427 543 12 0 427 543 4A5-2omd 0.770 nw 215E 36.90 41 0 a 1505 0 0 0 0 P 12C-Ow 0.091 2.55 128 120 120 306 154 0 0 0 0 C 16AWmd 0.032 - 0.90 2.32 1602 1602 1435 3715 252 252 226 585 F 22A-tpl 0989 27.69 0.00 1602 176 4878 0 252 41 1135 0 6 c)Amexarsion 23 197 Envelope loss/gain 16802 15970 3421 2627 12 a) IMtltrafion 2890 815 640 180 b) Roomeentilaticn 0 0 0 0 13 Intemalow.. Omlpants@ 230 0 0 p Appliances(other p 0 0 Subbtal(lines6to13) 19691 16785 4067 2807 Less e>demal load 0 0 0 0 Lesbarder 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 19691 16785 4061 2807 75 DUCloads 30% 53% 59M 8919 30% 53% 1217 1491 Total room load Air required (dm) 25591 2571 5278 4298 1160 7160 239 194 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed • wr✓fght3ofit- RigkSufe®Um2rsa1201919.021 RSU08101 2021-Jan121294:36 A ...r6lwngliwft HVAC1WYNNE-THE GRAND CARLION.np Calc=M18 Fror¢Caorfaces:N Page 1 -FI- wrightssoft, Right -A) Worksheet Date: Entire House By. QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 PMm: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS a@AOL.COM 1 Room name WIC MASTER BATH 2 IzVosrdwall 0 It 17.0 ft 3 Rcom height 8.0 ft heat/000l 8.0 ft heai/000l 4 Room dimensons 7.0 x 9D It 7.0 x 17.0 ft 5 Room area 63.0 IF 119D IF Ty Construction U-value Or HTM Area (fF) Load number (BWhAF--g (BWh&2) or penm�eler (ft) (BWh) or�perimeeW (ft) (BWh) Heat Cool Gros N/P/S Heat Cool Gross NIPS Heat Cool 6 VL 13A-0as 0.143 ne 4.00 255 0 0 0 0 0 0 0 0 1Ac1on 1270 ne 35.56 70.43 0 0 0 0 0 0 0 0 V)/ 13A-0as 0.143 se 4.00 255 0 0 0 0 0 0 0 0 1Aclom 1270 se 35.56 70.95 0 0 0 0 0 0 0 0 11 ��DC 1100 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W 13A-0os 0.143 s 4.00 255 0 0 0 0 0 0 0 0 13AA= 0.143 w 4.00 2.55 0 0 0 0 136 130 521 331 7A7clom 1270 sw 3556 70.95 0 0 0 0 6 0 213 426 1Ac1om 1270 sw 3556 70.95 0 0 0 0 0 0 0 0 13AAocs 0.143 nw 4.00 255 0 0 0 0 0 0 0- 0 1Acion 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 1Aclon 1270 nw 3556 4524 0 0 0 0 0 0 0 0 4A5-2omd 0.770 rm 21.56 X90 0 0 0 0 0 0 0 0 P 12C-0m 0.091 - 255 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 63 63 56 w 119 119 107 276. F 22A-yl 0.989 - 27.69 0.00 63 0 0 0 119 17 471 0 6 c)AED Branson -13 55 Envelope losslgain 56 133 13fl 1087 12 a) Infiltration 0 0 265 75 b) Roomvenfiladon 0 0 0 0 13 InIamalgains Ooarpants@ 230 0 0 0 Appiimossofher 0 0 0 Subtotal (lines6 to 13) 56 133 1577 1162 Lessexamallcad 0 0 0 0 Lessbansler 0 0 0 0 Redistribuffon 0 0 0 0 14 15 Subtohal Duct loads 56 133 577 1162 30% 53% 17 71 30% 53% 472 618 Total room load Air required(rfm) 73 204 2049 17 3 9 93 8D go Calculations approved bvACCAto meet all requirements of Manual J 8th Ed c- wrrll9Fv1't� RigItSute®Un2021.1ant21294:36 versa1201919.021 RSU08107 Paget ...rtAWd9Woft HMALYWYNNE-THE GRANDCARL7ONAp Calc=MJ6 Frond DoorfaMS:N t wright5l Right-M) Worksheet °yDat Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., FF.. PIERCE, FL 34946 Ptore:772.4666799 Fax 772-4666796 Email: QUICKCALCS@4OL.COM 1 Room name KrrCHEN BATH 2 E1posedwsll 0 It 5.0 it 3 Room height 8.0 ft heakool 9.4 It heatlmol 4 Room dimensom 1.0 x 192A It 9.0 x 5.0 It 5 Room area 192.0 IF 45.0 IF Ty Construction U-value Or HTM Area Load �(� Load number (BLhFF-°F) (EMJW or perimeter (ft) (BWh) or pen (ft) (Btuh) Heat Cool Gross WPIS Heat Cool Gros NIPS Heat Cool 6 VI—(' 13A-4o s 0.143 ne 4.00 2.55 0 0 0 0 47 47 186 120 1AcI= 1270 ne 3556 70.43 0 0 0 0 0 0 0 0 13A-4= 0.143 se 4.00 2S5 0 0 0 0 0 0 0 0 tAclom 1270 se 3556 70.95 0 0 0 0 0 0 0 0 11 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W 13A-4= 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 13A-4= 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 w 3556 70.95 0 0 0 0 0 0 0 0 tAclorn 1270 w 3556 7095 0 0 0 0 0 0 0 0 13A4= 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 13 1A lom 1270 nw 3556 4524 0 0 0 0 0 0 0 0 lhclan 1270 my 3556 4524 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 2156. 36.90 0 0 0 0 0 0 0 0 P 12C-0s 0.097 2.55 128 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 090 232 192 192 172 445 45 45 40 104 F 22A-G11 0.989 - 27.69 0.00 192 0 0 0 45 5 138 0 6 c)AED exarson -39 -22 Ernelope loss'gain 172 406 367 202 12 a) In41tralion 0 0 92 26 b) Room eenfilabon 0 0 0 0 13 Internal gains Oovpants@ 230 0 0 0 0 Applianoasiother 0 0 Subtrllal(lines6t013) 172 406 459 228 Lesexlemal load 0 0 0 0 Lestransfer 0 0 0 0 Redistributon 0 0 0 0 14 15 Subbial DuctloaCloads 30% 539/. 12 52 406 216 300/6 530/6 459 737 228 121 Total room load ry24 622 526 316 Air required(dm) 70 28 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed u191RSW8101 2021Jan1212:04:6 ..rlsWngFlsoflHVACWYNNE-iHEGRA,NDCARLIONrLp Ca1 c=IvL8 FrontDooriaresN Page wrightsoft° Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Plnre: 772466-6799 Fax 772466.6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM2 ENTRY 2 EVosedwall 302 It 6.0 It 3 Room height 8.0 ft heat/000l 8.0 it heaNmol 4 Room dimensoos t0 x 1905 ft 6.0 x 10.0 It 5 Room area 1905 IF 60A fe Ty Consbvcbon U-value Or HTM Area Load Area number I (BWh/R-`F) (BWhAf'0 or perimeter (ft) (BWh) or perimeter (ft) (BNh) Heat Cool Gros N/P5 Heat Cool Gross N/P5 Heat Cool 6 V}/ 13A4ocs 0.143 ne 4.00 2S5 120 120 480 305 0 0 0 0 �C 1Ac1om 1270 ne 3556 70.43 0 0 0 0 0 0 0 0 13A4ocs 0.143 se 4.D0 2.55 80 60 240 153 48 27 108 69 1Ac1om 1270 se 3556 70.95 20 0 711 1419 0 0 0 0 11 11DO 0390 se 1092 1121 0 0 0 0 21 21 229 238 w 13A4ocs 0.143 s 4.00 255 34 34 136 86 0 0 0 0 13A-4= 0.143 sw 4.00 2.55 8 8 32 20 0 0 0 0 T --GG 1Ac1om 1270 sx 3556 70.95 0 0 0 0 0 0 0 0 1Ac1om 1270 sw 3556 70.95 0 0 0 0 0 0 0 0 13A4= 0.143 nw 4A0 2S5 0 0 0 0 0 0 0 0 1Ac1om 1270 nw 3556 4524 0 0 0 0 0 0 0 0 1Ac1om 1270 nw 35.56 4524 0 0 0 0 0 0 0 0 4AS2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P 12C-OSN 0.091 - 255 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 0,90 2.32 191 191 171 442 60 60 54 139 F 22A-yl DM - 27.69 0.00 191 30 835 0 60 6 165 0 6 c)AEDexivrsion 20.0 41 Envelope loss/gain 2606 2635 557 404 12 a) Irifiltation 472 133 b) Roomsentilaion 0 0 0 0 13 Interrialgains O—panSQ 230 0 0 0 ApplianoeYotllcv 0 0 0 Subtotal(lirIes6to13) 3078 2768 651 430 Lesexdemalload 0 0 Lestrarsfer 0 0 0 0 0 0 Redistribulon 0 0 0 0 14 Subtotal 3078 2768 1 65430 15 DUC110ads 30% 53% 922 1471 30% 53% 195 229 229 Total room load 4000 4239 846 630 Air required(cfm) 181 191 3 308 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed Rlg 1Sute@ Uriversa1201919.021 RSUD8101 202t-Jant2 t294:36 A ...rMWngft oftWAQWYNNE-THE GRAND CARLTONny Caic=M18 Frort Doorfaces N Page �}Fwrightsofr Right-J®Worksheet Jae Entire House °atD: QUICK CALCS, INC. By. 317ST. LlCIE LN.,Fr..PIERCE, FL34946 Pfore:772-466-6799R=772466-6796 EreiI:QUIOKCALCS@AOL.COM 1 Room name LAUNDRY GREATAP4WG 2 E1posedxell 6D It 46D ft 3 Room height 8.0 It heaNmol 12D It heatlmol 4 Room dimensions 7.0 x 6D It 11) x 488.0 It 5 Room area 42.0 M 488D ft' Ty Construction U-value Or HTM Area Load Am number I (BWhIH'-°F) (BWM� or perimeter (to(BWh) or perimeteter (ft) OW) Hit Cod G o M S Heat Cool Gross M S Heat Cool 6 Wl - 13A4= 0.143 ne 4.00 - 2.55 0 0 - 0 0 312 274 1098 698 �C 1Ac1am IZM ne 3556 70A3 0 0 0 0 ...38. 0 1344 -' 2662 4y 13A4as 0.143 se 4M 255 0 0 0 0 0 0 0 0 L�DC 1Adw 1270 se 35M 70.95 0 0 0 0 0 0 0 0 11 11DO 0390 se 10.92 1131 0 0 0 0 0 0 0 0 W 13A4ocs - Q143 a 4.00 255 0 0 0 0 0 0- 0 - 0 y/ 13A4= 0-143 w 4D0 255 48 48 192 122 0 0 0 0 1ACIom 1270 six 3556 70.95 0 0 0 0 0 0 0 0 `ACC 1A-dom 1270 s.Y 3556 70.95 0 0 0 0 0 0 0 0 13A4= - - 0.143 nw 4.00 255 0 0 0 0 240 199 - 798 - 507 1Ac1= 1270 = 3556 4524 0 0-. 0 -. 0 0 0 0 - 0 1Aa1an 1270 rw 3556 4524 0 0 0 0 - - - 0 0 0 -D 4A5-20md 0.770 my 2156 36.90 - 0 0 0 0 41 0 880 1505 P 12C-Ow 0D91 - 255 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 232 42 42 38 97 488 488 437 - 1132 F 22A401 0289 - 2759 Om 42 6 166 0 488 46 1274 0 6 c)AED emersion -22 Envelope lam'gain 396 198 5830 5908 12 a) IntiPoation 94 26 1077 304 b) Roomuentilation 1 0 0 0 0 13 trrtemalgairts Oaarpan6@ 230 0 0 0 0 Applianoeabd er 0 0 Subtotal(lines6to13) 490 224 6907 6212 Lesselamalload 0 0 0 0 L.ess9anskr 0 0 0 0 Redlstilbu5on 0 01 0 0 14 Subtotal 490 2241 6907 6212 15 Dudbads 301% 53% 147 119 30% 531/6 2070 3301 Total room bad 636 95112 Air requimd (dm)4071 Calculations aooroved bvACCAto meet all requirements of Manual J 8th Ed 2021Jan121294:36 �# RigltSuR!Lhuaraa1201919.021 RSU08101 Page 5 -.rbAWdgrtscd HVAQWYNNE-THEGRANDCA;U-10Nnp Calc=M18 Front Doorfac.N wrightsofr Right -A) Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LIJCIE LN., Fr.. PIERCE, FL 34946 Prone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS AOL.COM 1 Room name BEDROOM3 2 E1Qwsdwall 25.0 ft 3 Room height 8.0 It heatlmol 4 Room dimensions 15.0 x 10.0 ft 5 Room area 150.0 IF Ty Construction U-value Or HTM Area (fe) Load Area Load number (BWh@'-q or perimeter (ft) (Btih) or perimeter Hea[ Cool Gros NIPS Heat Cool Gross NIPS Heat Cool 6 V+/ 13A4os 0.143 ne 4.00 255 0 0 0 0 L—C 1AcIom 1270 ne 3556 70.43 0 0 0 0 13A-4= 0.143 se 4.00 2.55 0 0 0 0 �C IA-dom 1270 se 3556 70.95 0 0 0 0 11 L--D 11D0 0.390 se 10.92 11.31 0 0 0 0 W 13A-4ors 0.143 s 4.00 2,55 0 0 0 0 W, 13A-0ors 0.143 sx 4.00 255 60 60 240 153 1A-dom 1270 sv 3556 70.95 0 0 0 0 T=CG IA-dom 1270 six 35.56 7095 20 0 711 1419 13A4ocs 0.143 nw 4.00 255 0 0 0 0 1AClom 1270 nw 3556 4524 0 0 0 A 1A-dom 1270 nw 3556 4524 0 0 0 0 4A5-2omd 0.770 my 2156 36.90 0 0 0 0 P 12C-Ow 0.091 - 2.55 128 120 120 306 154 C 16A-30md 0.032 - 0.90 2.32 150 150 134 348 F 22A-tol 0989 - 27.69 0.00 150 25 692 0 6 c)AEDemnson 296 Envelope losslgain 2084 2369 12 a) Inrilbation 156 44 b) Roomvenblabon 0 0 13 Intemalgaim Oolpants@ 230 0 0 Appliances/ottrer 0 Subtotal(lines6trr 13) 2240 2413 LesexrYmalload 0 0 Lestran4er 0 0 RedLstribuGon 0 0 14 Subh>ml 2240 2413 15 Dud loads 30°% 53% 671 1282 Total mom load 2911 3695 Air required (dm) 132 167 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed a a Ura9021 RSU08101 2021-Jan1212:04:36 -.r6Wrgfsoft HVAQWYNNE-THE GRANDCMLTONnLp Clc=MB FrorYOoortaces: N Page