Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Efficiency Code
l J ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge F1aCom v1.22 INPUT DATA REPORT Project Name: BUH PRIMA VISTA Project Title: BANK UNITED PRIMA VISTA Address: 7526 S. US 1 State: FL Zip: 34952 Owner: BANK UNITED Project Information Orientation: North Building Type: Office (Business) Building Classification: Renovation to existing building No.of Storeys: 1 GrossArea: 1838 Zones No Acronym Description Type Load Profile Area Multiplier Total Area [sf] [sf] 1 BANK BANK CONDITIONED Uses Building Load 1837.5 1 . 1837.5 El Profile 4/10/2005 EnergyGauge F1aCom FLCCSB v1.22 1 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] IN [ft] plier [sf] [cf] In Zone: BANK 1 FIRST FLR SHOWROOM/WARE Retail Establishments 75.00 24.50 9.00 1 1837.5 16537.5 HOUSE (Merchandising & Circulation Area) Applicable to all lighting, including accen Lighting No Type Power Control Type No.of [W] Ctrl pts In Zone: BANK In Space: FIRST FLR 1 Recessed Fluorescent - No vent 2976.00 Manual On/Off 15 El Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [h.sf.F/Btu] [Btu/sf.F] In Zone: BANK 1 NORTHEAST 5/8" stucco 24.50 15.00 1 367.5 /8"CMU/R-4.2 NorthEast 0.2395 5.7081 35.35 4.18 13TWN24"oc/.5" Gyp 2 SOUTHWEST WALL 5/8"stucco 24.50 15.00 1 367.5 /8"CMU/R-4.2 SouthWes 0.2395 t 5.7081 35.35 4.18 BTWN24"oc/.5" Gyp 4/10/2005 EnergyGauge FlaCom FLCCSB v1.22 Windows No Description Type Shaded UCen SC Vis.Tr W H (Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier [sf] In Zone: BANK In Wall: SOUTHWWEST WALL 1 PrOZo1Wa2Wil DOUBLE CLEAR Yes 0.6514 0.88 0.81 4.00 8.00 4 128.0 ❑ IG Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.F/Btu] In Zone: BANK In Wall: NORTHEAST WALL 1 PrOZo1Wa1Drl Aluminum door, No 3.00 6.66 1 20.0 0.1919 43.67 0.53 5.21 ❑ 1.25 in. polystyrene In Wall: SOUTHWWEST WALL 1 PrOZo1Wa2Dr1 Aluminum door, No 3.00 7.00 1 21.0 0.1919 43.67 0.53 5.21 ❑ 1.25 in. polystyrene Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] [ft] plier [sf] [deg] [Btu/hr. Sf. F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: BANK 1 ROOF BUILTUP 75.00 24.50 1 1837.5 0.00 0.0534 0.95 6.33 18.74 ❑ ROOF/R-19//Mtl Deck 4/10/2005 EnergyGauge F1aCom FLCCSB v1.22 Skylights No Description Type UCen Shading Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] Coeff [ft] IN [Sf] [Sf] In Zone: In Roof: Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value IN [ft] plier [sf] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf] [h.sf.F/Btu] In Zone: BANK 1 PrOZo1F11 Concrete floor, 75.00 24.50 1 1837.5. 0.5987 9.33 140.00 1.67 carpet and rubber pad Systems PrOSyl System 1 Constant Volume Packaged System No. Of Units 1 Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled 65000 to 135000 Btu/h Cooling Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 78800.00 2400.00 11.10 8.30 0.80 ❑ Plant Equipment Category Size Inst.No Eff. IPLV 4/10/2005 EnergyGauge FlaCom FLCCSB v1.22 S - Water Heaters W-Heater Description Capacit Cap.Unit VP Rt. Efficienc Loss 1 Instantaneous Water heaters - [Not Req] 2 [kW] [EF] [Not Req] ❑ Electric EA -Lighting Description Categories. Area/Len/No. of units [sf/ft/No] Wattage [W] Piping No Type Operating Insulation Temperature Conductivity [F] [ Btu-in/h.sf.F] Nomonal pipe Diameter [in] Insulation Is Runout? Thickness [in] 1 Heating System (Steam, Steam Condensate, & Hot Wat 105.00 0.28 0.37 0.75 Yes 0 Fenestration Used Glass Frame Frame Name Glass Type No. of SC VLT Panes Conductance Conductance Absorptance [Btu/h.sf.F] [Btu/h.sf.F] ApLbWnd6 DOUBLE CLEAR IG 2 0.6514 0.8800 0.8120 0.4340 0.7000 ❑ 4/10/2005 EnergyGauge F1aCom FLCCSB v1.22 5 Y Materials Used Mat No Acronym Description Only R-Value Used RValue [h.sf.FBtu] Thickness IN Conductivity [Btu/h.ft.F] Density [lb/cf] SpecificHeat [Btu/Ib.F] 18 Matl18 2 in. Wood No 2.3857 0.1670 0.0700 37.00 0.3900 ❑ 264 Mat1264 ALUMINUM, 1/16 IN No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 214 Mat1214 POLYSTYRENE, EXP., No 5.2100 0.1042 0.0200 1.80 0.2900 ❑ 1-1/4IN, 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 -50.00 0.2000 ❑ BOARD,1/2IN 206 Mat1206 CELLULOSE,FILL,5.5IN,R- No 20.8318 0.4583 0.0220 3.00 0.3300 ❑ 20 151 Matl15l CONC HW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 41N 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 123 Mat1123 CONC BLOCK No 1.7227 0.6667 0.3870 53.00 0.2000 ❑ MW,8IN,HOLLOW 159 Mat1159 CONC No 0.3202 0.3333 1.0410 140.00 0.2000 ❑ HW-UNDRD-140LB-4IN 57 Mat157 3/4 in. Plaster or gypsum No 0.1488 0.0625 0.4200 100.00 0.2000 ❑ 72 Mat172 AIR LAYER, 3/4IN OR .Yes 0.9000 ❑ LESS, VERT. WALLS 267 Mat1267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 ❑ 266 Mat1266 2x4@ 16" oc + RI 1 Batt No 8.3343 0.2917 0.0350 9.70 0.2000 ❑ 215 Mat1215 POLYSTYRENE, EXP., No 8.3350 0.1667 0.0200 1.80 0.2900 ❑ 2IN, 105 Mat1105 CONC BLK HW, 8IN, No 1.1002 0.6667 0.6060 69.00 0.2000 ❑ HOLLOW 256 Mat1256 WOOD, SOFT, 1-1/21N No 1.8939 0.1250 0.0660 32.00 0.3300 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 0 42 Mat142 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 86 Mat186 BRICK, COMMON, 4IN No 0.8012 0.3333 0.4160 120.00 0.2000 ❑ 4/10/2005 EnergyGauge FlaCom FLCCSB v1.22 6 211 Mat1211 POLYSTYRENE,EXP.,1/2I No 2.0850 0.0417 0.0200 1.80 0.2900 ❑ N, 12 Matl12 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 ❑ 218 Mat1218 POLYURETHANE,EXP.,1/2 No 3.2077 0.0417 0.0130 1.50 0.3800 ❑ IN, 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 4 Matl4 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 271 Mat1271 2x4@24" oc + R11 Batt No 10.4179 0.2917 0.0280 7.11 0.2000 0 272 Mat1272 Panel with 7/16" panels Yes 0.9044 ❑ 273 Mat1273 Hollow core flush (1.375") Yes 1.2777 ❑ 274 Mat1274 Solid core flush (1.375") Yes 1.7141 ❑ 275 Mat1275 Panel with 7/16" panels Yes 1.0019 ❑ (1.375") 276 Mat1276 Hollow core flush (1.75") Yes 1.3239 ❑ 277 Mat1277 Panel with 1-1/8" panels Yes 1.7141 ❑ (1.75") 278 Mat1278 Solid core flush (1.75") Yes 1.6500 ❑ 279 Mat1279 Solid core flush (2.25") Yes 2.8537 ❑ 280 Mat1280 Fiberglass/Mineral wool core Yes 0.8167 ❑ 281 Mat1281 Paper Honeycomb core Yes 0.9357 ❑ 282 Mat1282 Solid Urethane foam core Yes i.6500 ❑ 283 Mat1283 Solid mineral fiberboard core Yes 1.7816 ❑ 284 Mat1284 Polystyrene core (18 ga steel) Yes 2.007-1 ❑ 1 285 Mat1285 Polyurethane core (18 ga Yes 2.5983 ❑ steel) 2 286 Mat1286 Polyurethane core (24 ga Yes 2.5983 ❑ steel) 1 287 Mat1287 Polyurethane core (24 ga Yes 4.1500 ❑ steel) 2 288 Mat1288 Solid Urethane foam core Yes 4.1500 ❑ 81 Matl81 ASPHALT -ROOFING, Yes 0.1500 ❑ ROLL 244 Mat1244 PLYWOOD, 1/21N No 0..6318 0.0417 0.0660 34.00 0.2900 ❑ 185 Mat1185 CLAY TILE, PAVER, 3/81N No 0.0301 0.0313 1.0410 120.00 0.2000 ❑ 82 Mat182 ASPHALT -SHINGLE AND Yes 0.4400 ❑ SIDING 11 Matl11 2 in. Insulation No 6.6800 0.1670 0.0250 2.00 0.2000 ❑ 4/10/2005 EnergyGauge FlaCom FLCCSB v1.22 7 95 Mat195 CONC BLOCK No 0.7107 0.3333 0.4690 101.00 0.2000 ❑ HW-4IN-HOLLOW 248 Mat1248 ROOF GRAVEL OR No 0.0500 0.0417 0.8340 55.00 0.4000 ❑ SLAG1/21N 94 Mat194 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/81N Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1002 Aluminum door, 1.25 in. polystyrene No No 0.19 0.53 43.67 5.2104 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 264 ALUMINUM, 1/16IN 0.0050 0.00 ❑ 2 214 POLYSTYRENE, EXP., 1-1/41N, 0.1042 0.00 ❑ 3 264 ALUMINUM, 1/16IN 0.0050 0.00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.F/Btu] 1004 Concrete floor, carpet and rubber pad No No 0.60 9.33 140.00 1.6703 ❑ Layer Material Material Thickness Framing No. IN Factor 1 151 CONC HW, DRD, 140LB, 41N 0.3333 0.00 ❑ 2 178 CARPET W/RUBBER PAD 0.00 ❑ 4/10/2005 EnergyGauge FlaCom FLCCSB v1.22 9 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1011 5/8" stucco /8"CMU/R-4.2 BTWN24"oc/.5" No No 0.24 5.71 35.35 4.1761 ❑ Gyp Layer Material Material Thickness Framing No. IN Factor 1 268 0.625" stucco 0.0521 0.00 ❑ 2 42 8 in. Lightweight concrete block 0.6670 0.00 ❑ 3 269 .75" ISO BTWN24" oc 0.0440 0.00 ❑ 4 187 GYP OR PLAS BOARD,1/21N 0.0417 0.00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1043 BUILTUP ROOF/R-19//Mtl Deck No No 0.05 0.95 6.33 18.7366 ❑ Layer Material Material No. 1 94 BUILT-UP ROOFING, 3/81N 2 11 2 in. Insulation Thickness Framing [ft] Factor 0.0313 0.00 ❑ 0.4600 0.00 ❑ 4/10/2005 EnergyGauge MaCom FLCCSB 0.22 9