ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
EnergyGauge F1aCom v1.22
INPUT DATA REPORT
Project Name: BUH PRIMA VISTA
Project Title: BANK UNITED PRIMA VISTA
Address: 7526 S. US 1
State: FL
Zip: 34952
Owner: BANK UNITED
Project Information
Orientation: North
Building Type: Office (Business)
Building Classification: Renovation to existing building
No.of Storeys: 1
GrossArea: 1838
Zones
No Acronym Description Type Load Profile Area Multiplier Total Area
[sf] [sf]
1 BANK BANK CONDITIONED Uses Building Load 1837.5 1 . 1837.5 El
Profile
4/10/2005 EnergyGauge F1aCom FLCCSB v1.22 1
Spaces
No Acronym Description
Type Depth Width
Height Multi Total Area
Total Volume
[ft] IN
[ft] plier
[sf]
[cf]
In Zone: BANK
1 FIRST FLR SHOWROOM/WARE Retail Establishments 75.00 24.50
9.00 1
1837.5
16537.5
HOUSE
(Merchandising &
Circulation Area) Applicable
to all lighting, including
accen
Lighting
No Type
Power
Control Type
No.of
[W]
Ctrl pts
In Zone: BANK
In Space: FIRST FLR
1 Recessed Fluorescent - No vent 2976.00
Manual On/Off
15 El
Walls
No Description
Type Width H (Effec) Multi Area
DirectionConductance
Heat
Dens. R-Value
[ft] [ft] plier [sf]
[Btu/hr. sf. F]
Capacity
[lb/cf] [h.sf.F/Btu]
[Btu/sf.F]
In Zone: BANK
1 NORTHEAST
5/8" stucco 24.50 15.00 1 367.5
/8"CMU/R-4.2
NorthEast 0.2395
5.7081
35.35 4.18
13TWN24"oc/.5"
Gyp
2 SOUTHWEST WALL
5/8"stucco 24.50 15.00 1 367.5
/8"CMU/R-4.2
SouthWes 0.2395
t
5.7081
35.35 4.18
BTWN24"oc/.5"
Gyp
4/10/2005 EnergyGauge FlaCom FLCCSB v1.22
Windows
No Description Type
Shaded
UCen SC
Vis.Tr
W H (Effec) Multi Total Area
[Btu/hr sf F]
IN [ft]
plier [sf]
In Zone: BANK
In Wall: SOUTHWWEST WALL
1 PrOZo1Wa2Wil DOUBLE CLEAR Yes
0.6514 0.88
0.81
4.00 8.00
4 128.0
❑
IG
Doors
No Description Type
Shaded? Width H (Effec) Multi
Area
Cond.
Dens. Heat Cap. R-Value
[ft] [ft]
plier
[sf]
[Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.F/Btu]
In Zone: BANK
In Wall: NORTHEAST WALL
1 PrOZo1Wa1Drl Aluminum door,
No
3.00 6.66
1
20.0 0.1919
43.67 0.53 5.21
❑
1.25 in.
polystyrene
In Wall: SOUTHWWEST WALL
1 PrOZo1Wa2Dr1 Aluminum door,
No
3.00 7.00
1
21.0 0.1919
43.67 0.53 5.21
❑
1.25 in.
polystyrene
Roofs
No Description Type
Width
H (Effec) Multi
Area
Tilt
Cond.
Heat Cap Dens. R-Value
[ft]
[ft] plier
[sf]
[deg]
[Btu/hr. Sf. F]
[Btu/sf. F] [lb/cf] [h.sf.F/Btu]
In Zone: BANK
1 ROOF BUILTUP
75.00
24.50 1
1837.5
0.00
0.0534
0.95 6.33 18.74
❑
ROOF/R-19//Mtl
Deck
4/10/2005 EnergyGauge F1aCom FLCCSB v1.22
Skylights
No Description Type
UCen Shading Vis.Trans W H (Effec) Multiplier
Area Total Area
[Btu/hr sf F] Coeff
[ft] IN
[Sf] [Sf]
In Zone:
In Roof:
Floors
No Description Type
Width H (Effec) Multi
Area Cond. Heat Cap. Dens.
R-Value
IN [ft] plier
[sf] [Btu/hr. sf. F] [Btu/sf. F] [lb/cf]
[h.sf.F/Btu]
In Zone: BANK
1 PrOZo1F11 Concrete floor,
75.00 24.50 1
1837.5. 0.5987 9.33 140.00
1.67
carpet and rubber
pad
Systems
PrOSyl System 1
Constant Volume Packaged System No. Of Units 1
Component Category
Capacity
Efficiency IPLV
1 Cooling System (Air Cooled 65000 to 135000 Btu/h
Cooling Capacity)
2 Air Handling System -Supply (Air Handler (Supply) -
Constant Volume)
78800.00
2400.00
11.10 8.30
0.80 ❑
Plant
Equipment Category
Size
Inst.No Eff. IPLV
4/10/2005 EnergyGauge FlaCom FLCCSB v1.22
S -
Water Heaters
W-Heater Description Capacit Cap.Unit VP Rt. Efficienc Loss
1 Instantaneous Water heaters - [Not Req] 2 [kW] [EF] [Not Req] ❑
Electric
EA -Lighting
Description
Categories.
Area/Len/No. of units
[sf/ft/No]
Wattage
[W]
Piping
No Type
Operating Insulation
Temperature Conductivity
[F] [ Btu-in/h.sf.F]
Nomonal pipe
Diameter
[in]
Insulation Is Runout?
Thickness
[in]
1 Heating System (Steam, Steam Condensate, &
Hot Wat
105.00 0.28
0.37
0.75 Yes 0
Fenestration Used
Glass Frame Frame
Name Glass Type No. of SC VLT
Panes Conductance Conductance Absorptance
[Btu/h.sf.F] [Btu/h.sf.F]
ApLbWnd6 DOUBLE CLEAR IG 2 0.6514 0.8800 0.8120 0.4340 0.7000 ❑
4/10/2005 EnergyGauge F1aCom FLCCSB v1.22 5
Y
Materials Used
Mat No
Acronym
Description
Only R-Value
Used
RValue
[h.sf.FBtu]
Thickness
IN
Conductivity
[Btu/h.ft.F]
Density
[lb/cf]
SpecificHeat
[Btu/Ib.F]
18
Matl18
2 in. Wood
No
2.3857
0.1670
0.0700
37.00
0.3900
❑
264
Mat1264
ALUMINUM, 1/16 IN
No
0.0002
0.0050
26.0000
480.00
0.1000
❑
214
Mat1214
POLYSTYRENE, EXP.,
No
5.2100
0.1042
0.0200
1.80
0.2900
❑
1-1/4IN,
187
Mat1187
GYP OR PLAS
No
0.4533
0.0417
0.0920
-50.00
0.2000
❑
BOARD,1/2IN
206
Mat1206
CELLULOSE,FILL,5.5IN,R-
No
20.8318
0.4583
0.0220
3.00
0.3300
❑
20
151
Matl15l
CONC HW, DRD, 140LB,
No
0.4403
0.3333
0.7570
140.00
0.2000
❑
41N
178
Mat1178
CARPET W/RUBBER PAD
Yes
1.2300
❑
265
Mat1265
Soil, 1 ft
No
2.0000
1.0000
0.5000
100.00
0.2000
❑
48
Mat148
6 in. Heavyweight concrete
No
0.5000
0.5000
1.0000
140.00
0.2000
❑
123
Mat1123
CONC BLOCK
No
1.7227
0.6667
0.3870
53.00
0.2000
❑
MW,8IN,HOLLOW
159
Mat1159
CONC
No
0.3202
0.3333
1.0410
140.00
0.2000
❑
HW-UNDRD-140LB-4IN
57
Mat157
3/4 in. Plaster or gypsum
No
0.1488
0.0625
0.4200
100.00
0.2000
❑
72
Mat172
AIR LAYER, 3/4IN OR
.Yes
0.9000
❑
LESS, VERT. WALLS
267
Mat1267
0.75" stucco
No
0.1563
0.0625
0.4000
16.00
0.2000
❑
266
Mat1266
2x4@ 16" oc + RI 1 Batt
No
8.3343
0.2917
0.0350
9.70
0.2000
❑
215
Mat1215
POLYSTYRENE, EXP.,
No
8.3350
0.1667
0.0200
1.80
0.2900
❑
2IN,
105
Mat1105
CONC BLK HW, 8IN,
No
1.1002
0.6667
0.6060
69.00
0.2000
❑
HOLLOW
256
Mat1256
WOOD, SOFT, 1-1/21N
No
1.8939
0.1250
0.0660
32.00
0.3300
❑
268
Mat1268
0.625" stucco
No
0.1302
0.0521
0.4000
16.00
0.2000
0
42
Mat142
8 in. Lightweight concrete
No
2.0212
0.6670
0.3300
38.00
0.2000
❑
block
269
Mat1269
.75" ISO BTWN24" oc
No
2.2321
0.0625
0.0280
4.19
0.3000
❑
86
Mat186
BRICK, COMMON, 4IN
No
0.8012
0.3333
0.4160
120.00
0.2000
❑
4/10/2005 EnergyGauge FlaCom FLCCSB v1.22 6
211
Mat1211
POLYSTYRENE,EXP.,1/2I
No
2.0850
0.0417
0.0200
1.80
0.2900
❑
N,
12
Matl12
3 in. Insulation
No
10.0000
0.2500
0.0250
2.00
0.2000
❑
218
Mat1218
POLYURETHANE,EXP.,1/2
No
3.2077
0.0417
0.0130
1.50
0.3800
❑
IN,
23
Mat123
6 in. Insulation
No
20.0000
0.5000
0.0250
5.70
0.2000
❑
4
Matl4
Steel siding
No
0.0002
0.0050
26.0000
480.00
0.1000
❑
271
Mat1271
2x4@24" oc + R11 Batt
No
10.4179
0.2917
0.0280
7.11
0.2000
0
272
Mat1272
Panel with 7/16" panels
Yes
0.9044
❑
273
Mat1273
Hollow core flush (1.375")
Yes
1.2777
❑
274
Mat1274
Solid core flush (1.375")
Yes
1.7141
❑
275
Mat1275
Panel with 7/16" panels
Yes
1.0019
❑
(1.375")
276
Mat1276
Hollow core flush (1.75")
Yes
1.3239
❑
277
Mat1277
Panel with 1-1/8" panels
Yes
1.7141
❑
(1.75")
278
Mat1278
Solid core flush (1.75")
Yes
1.6500
❑
279
Mat1279
Solid core flush (2.25")
Yes
2.8537
❑
280
Mat1280
Fiberglass/Mineral wool core
Yes
0.8167
❑
281
Mat1281
Paper Honeycomb core
Yes
0.9357
❑
282
Mat1282
Solid Urethane foam core
Yes
i.6500
❑
283
Mat1283
Solid mineral fiberboard core
Yes
1.7816
❑
284
Mat1284
Polystyrene core (18 ga steel)
Yes
2.007-1
❑
1
285
Mat1285
Polyurethane core (18 ga
Yes
2.5983
❑
steel) 2
286
Mat1286
Polyurethane core (24 ga
Yes
2.5983
❑
steel) 1
287
Mat1287
Polyurethane core (24 ga
Yes
4.1500
❑
steel) 2
288
Mat1288
Solid Urethane foam core
Yes
4.1500
❑
81
Matl81
ASPHALT -ROOFING,
Yes
0.1500
❑
ROLL
244
Mat1244
PLYWOOD, 1/21N
No
0..6318
0.0417
0.0660
34.00
0.2900
❑
185
Mat1185
CLAY TILE, PAVER, 3/81N
No
0.0301
0.0313
1.0410
120.00
0.2000
❑
82
Mat182
ASPHALT -SHINGLE AND
Yes
0.4400
❑
SIDING
11
Matl11
2 in. Insulation
No
6.6800
0.1670
0.0250
2.00
0.2000
❑
4/10/2005 EnergyGauge FlaCom FLCCSB v1.22 7
95
Mat195
CONC BLOCK No
0.7107 0.3333
0.4690
101.00
0.2000
❑
HW-4IN-HOLLOW
248
Mat1248
ROOF GRAVEL OR No
0.0500 0.0417
0.8340
55.00
0.4000
❑
SLAG1/21N
94
Mat194
BUILT-UP ROOFING, No
0.3366 0.0313
0.0930
70.00
0.3500
❑
3/81N
Constructs Used
No
Name
Simple
Massless Conductance Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sf.F]
[Btu/sf.F]
[lb/cf]
[h.sf.F/Btu]
1002
Aluminum door, 1.25 in. polystyrene No
No 0.19
0.53
43.67
5.2104
❑
Layer
Material Material
Thickness
Framing
No.
[ft]
Factor
1
264 ALUMINUM, 1/16IN
0.0050
0.00
❑
2
214 POLYSTYRENE, EXP., 1-1/41N,
0.1042
0.00
❑
3
264 ALUMINUM, 1/16IN
0.0050
0.00
❑
No
Name
Simple
Massless Conductance Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sf.F]
[Btu/sf.F]
[lb/cf]
[h.sf.F/Btu]
1004
Concrete floor, carpet and rubber pad No
No 0.60
9.33
140.00
1.6703
❑
Layer
Material Material
Thickness
Framing
No.
IN
Factor
1
151 CONC HW, DRD, 140LB, 41N
0.3333
0.00
❑
2
178 CARPET W/RUBBER PAD
0.00
❑
4/10/2005 EnergyGauge FlaCom FLCCSB v1.22
9
No
Name
Simple
Massless
Conductance
Heat Capacity
Density
RValue
Construct
Construct
[Btu/h.sf.F]
[Btu/sf.F]
[lb/cf]
[h.sf.FBtu]
1011
5/8" stucco /8"CMU/R-4.2 BTWN24"oc/.5" No
No
0.24
5.71
35.35
4.1761
❑
Gyp
Layer
Material
Material
Thickness Framing
No.
IN
Factor
1
268
0.625" stucco
0.0521
0.00
❑
2
42
8 in. Lightweight concrete block
0.6670
0.00
❑
3
269
.75" ISO BTWN24" oc
0.0440
0.00
❑
4
187
GYP OR PLAS BOARD,1/21N
0.0417
0.00
❑
No
Name
Simple
Massless
Conductance
Heat Capacity
Density
RValue
Construct
Construct
[Btu/h.sf.F]
[Btu/sf.F]
[lb/cf]
[h.sf.FBtu]
1043
BUILTUP ROOF/R-19//Mtl
Deck No
No
0.05
0.95
6.33
18.7366
❑
Layer Material Material
No.
1 94 BUILT-UP ROOFING, 3/81N
2 11 2 in. Insulation
Thickness
Framing
[ft]
Factor
0.0313
0.00 ❑
0.4600