Lighting Controls Compliance
Acronym Ashrae Description Area No. of Design Min Compli-
ID (sq.ft) Tasks CP CP ance
FIRST FLR 101 Retail Establishments 1,838 14 15 15 PASSES
(Merchandising & Circulation
Area) Applicable to all lighting,
including accen
PASSES
Project: BUH PRIMA VISTA
Title: BANK UNITED PRIMA VISTA
Type: Office (Business)
Location: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200)
(WEA File: D
System Report Compliance
PrOSyl System 1 Constant Volume Packaged No. of Units
System 1
Component Category Capacity Design Eff Design IPLV Comp-
Eff Criteria IPLV Criteria liance
Cooling System Air Cooled 65000 to 135000 11.10 8.90 8.30 8.30 PASSES
Btu/h Cooling Capacity
Air Handling Air Handler (Supply) - 0.80 0.80 PASSES
System -Supply Constant Volume
PASSES
Project: BUH PRIMA VISTA
Title: BANK UNITED PRIMA VISTA
Type: Office (Business)
Location: PORT ST LUCIE, ST LUCIE COUNTY, FL
(661200)
(WEA File: D
Water Heater Compliance
Design Min Design Max Comp
Description Type Category Eff Eff Loss Loss liance
Water Heater 1 Instantaneous Water All ratings PASSES
heaters - Electric
PASSES
4/10/2005 EnergyGauge FlaCom FLCCSB v1.22
Project: BUH PRIMA VISTA
Title: BANK UNITED PRIMA VISTA
Type: Office (Business)
Location: PORT ST
Piping System Compliance
Category
Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance
[inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in]
[F] .SF.F]
Heating System (Steam, Steam
0.37 True 105.00 0.28 0.75 0.67 PASSES
Condensate, & Hot Water)
PASSES
4/10/2005 EnergyGauge FlaCom FLCCSB 0.22