HomeMy WebLinkAboutREVISED TRUSS LAYOUT10'-1" CLG.10'-9" CLG.8'-1" CLG.4-1/16"1'12PLUMB CUT OVERHANG5HEEL HEIGHTTRUSS END DETAILHTU26HTU26HTU26HTU26HTU26HTU26HTU26HTU26HTU26HTU26HTU26HTU26HTU26HTU26HTU26HTU268'-9" CLG. HGT.8'-1" CLG.8'-1" CLG.8'-1" CLG.8'-1" CLG.8'-1" CLG.11'-1" CLG.2.5/12 Vault ----->Hatch Legend10'01'' A.F.F.8'01'' A.F.F.10'09'' A.F.F.9'09'' A.F.F.T30T31T32K4K4J4J4J4C1C2C4C5J4J4J4C4C5C1C2J4T33T34T35T36T37T1K2C1C2TC3TC4C5TC6TT2T3T4T5K1C1C2C3C4C5C6J1J1J1J1J1J1J1J1J1J1J1J1J2J2T22T21T20T19T18T17K3K3J3J3J3J3J3J3C1C2C3C4C5C6J3J3J3J3J3J3C4C5C6C1AC2ACC3ACJ3T16T15T14T13T12T11T10T9T8T7T6T23T24T25T26T27T29T38T39T40T41T41AJ2J2J2J2J2J2T28T28V2V155-04-002-04-002-00-0051-00-0055-04-0020-00-0011-00-00 8-02-00 11-10-0052-00-0024-01-0014-08-00 13-03-0052-00-008-04-0017-08-0820-02-0020-06-004-10-00 14-00-005-04-001-00-008-01-0020-05-0834-10-082-00-007-11-002-00-002-00-0018-09-081-10-0414-00-0016-00-005-06-1225-09-006-03-1222-00-006-00-002-00-002-00-0011-00-00.16HANGER BY BLDR.HTU28TRUSS CONNECTIONLISTHTU26-2PRODUCTHGUS28-2.QTYHGUS26-2HTU26x...HGUS28-3CAUTION!!!DO NOT ATTEMPT TO ERECTTRUSSES WITHOUT REFERRING TOTHE ENGINEERING DRAWINGS ANDBSCI-B1 SUMMARY SHEETS.ALL PERMANENT BRACING MUST BEIN PLACE PRIOR TO LOADINGTRUSSES. (ie. SHEATHING,SHINGLES, ETC.)ALL INTERIOR BEARING WALLSMUST BE IN PLACE PRIOR TOINSTALLING TRUSSES.REFER TO FINAL ENGINEERINGSHEETS FOR THE FOLLOWING.1) NUMBER OF GIRDER PLIES ANDNAILING SCHEDULE.2) BEARING BLOCK REQUIREMENTS.3) SCAB DETAILS (IF REQUIRED)4) UPLIFT AND GRAVITY REACTIONS.WARNINGBackcharges Will Not Be AcceptedRegardless of Fault Without PriorNotification By Customer Within 48Hours And Investigation ByBuilders FirstSource.NO EXCEPTIONS.The General Contractor Is ResponsibleFor All Connections Other Than Trussto Truss, Gable Shear Wall, AndConnections. Temporary andPermanent Bracing, And Ceiling AndRoof Diaphragm Connections.701 S. KINGS HIGHWAYFORT PIECE, FL 34945Ph. (772) - 461 5475IMPORTANTThis Drawing Must Be Approved AndReturned Before Fabrication WillBegin. For Your Protection Check AllDimensions And Conditions Prior ToApproval Of Plan.SIGNATURE BELOW INDICATES ALLNOTES AND DIMENSIONS HAVEBEEN ACCEPTED.By __________________Date_______ROOF LOADINGTCLL:TCDL:BCDL:TOTAL:DURATION:PSFPSFPSFPSFFLOOR LOADINGTCLL:TCDL:BCDL:TOTAL:DURATION:PSFPSFPSFPSF0737201.25102.REVISIONS:4.3.1.MAIN WIND FORCE RESISTING SYSTEM/C-C HYBRIDWIND ASCE7-16ENCLOSEDEXPOSURE CATEGORY COCCUPANCY CATEGORY IIWIND LOAD 170 MPH*TRUSSES HAVE BEEN DESIGNED FOR A 10.0 PSFBOTTOM CHORD LIVE LOAD NONCONCURRENT WITHANY OTHER LIVE LOADS.....Fort PierceCOUNTYSaint Lucie5804RAISCALE:MODEL:ADDRESS:CITY:JOB # :CRESTVIEWNTSDRAWN BY:BUILDER:DATE:3035562PROJECT:LR01/10/2022LOT / BLOCK:NEWTON RES5804 RAINTREE TRAILGROZA BUILDERS INCHANGER LEGEND* - ALL 2x HANGERS SHOWN ARE HTU26 UNLESS NOTEDOTHERWISE* - ALL 4x2 FLOOR HANGERS SHOWN ARE HHUS46UNLESS NOTED OTHERWISE