Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM 60OA-2004 EnergyGauge® 4.0 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION `4 Florida Department of Community Affairs s Residential Whole Building Performance Method A • r Project Name: Dale res Address: City, State: Owner: Dale Res Climate Zone: Central Builder: S.J.T. Calcs Permitting Office: Permit Number: iurisdictio.n Nuiiiber: 12. Cooling systems L New construction or existing New _ �. Single family or multi -family Singlefamily — a. Central Unit Cap:61.5kBtu/hr 3. Number of units, if multi -family 1 _ — 4. Number of Bedrooms 3 SEER: 13.00 _ b. central Unit — 5. Is this a worst case? No Cap: jaz itBwi, SEER 6. Conditioned floor area (ft2) 3599112 I. 00 c. N/A _ 7. Glass type land area: (Label reqd. by 13-104.4.5 if not default) rat k: a. U-factor: p DeSCrI tl0n Area Single i �. I10atung systenis Y - (or or Double DEFAULT) 7a. (Dble, U=0.8) 136.0 ft2 — a. Electric Heat Pump' Cap:_57.5 kBtu/hr b. SHGC: (or Clear or Tint DEFAULT) 7b. (SHGC=0.70) 348.0 ft2 _ — b. Electric Heat Pump ,L � ) Cap: 17.1 kBtu/hr 8. Floor types �� �� E. — H pF.7.0 a. Slab -On -Grade Edge Insulation R=0.0,0.0(p)ft — _ c. N/A b. N/A {� — c. N/A _ 1,4 . Hot waEsystems 9. Wall types a RjPrtn� RPc ire Cap: a 50.0gallons a. Concrete, Int Insul, Exterior R=4.1, 1998.2 ft2.� _ V EF: 0.97b. ,—O Frame, Wood, Exterior R=11.0, 724.0ft I� — liN/A c. N/A — d. N/A �. °� — c. Conservation credits e N/A — (FIR -Heat recovery, Solar 10. Ceiling types — A4�, DHP-Dedicated heat um pump) a. Single Assembly _ 2 �R44b 0, 2658.0 ft b. N/A ` V% 15. HVAC credits c. N/A — (CF-Ceiling fan, CV -Cross ventilation, t' z — HF-Whole house fan, 11. Ducts ' Sup: PT -Programmable Thermostat, a UncRt Uric: AF Sealed):Garage Sup. R=6.0,100.0 ft MZ-C-Multizone cooling, b. §pp U c: 'Ret Unc AII(Sealed):Interior Sup. R=6.0, 100.0 ft — MZ-H-Multizone heating) Glass/Floor Area: 0.10 I hereby certify that the plans. calculation are in compliance PREPARED BY: DATE: !y Total as -built points: 37856 PASS Total base points: 47440 Al ClTicatfOrI5 covered by this Florida Energy Code. i3 J6 I , I hereby certify that this buildin , as with the Florida Energy C d . OWNER/AGENT- DATE: 112 I Predominant glass type. Fo actual c is in compliance Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: type and areas, see Summer & Winter Glass output on pages 2&4. EnergyGauge® (Version: FLRCSB v4.0) FORM 60OA-2004 EnergyGauge® 4.0 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:, , , PERMIT #: I BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 3599.0 25.78 16700.8 Double,U=0.82,SHGC=0.70 W 0.0 0.0 64.0 53.87 1.00 3448.0 Double,U=0.82,SHGC=0.70 S 0.0 0.0 72.0 45.07 1.00 3245.2 Single,U=1.00,SHGC=0.83 S 0.0 0.0 21.0 54.41 1�00 ; 42.6 Double,U=0.82,SHGC=0.70 N 0.0 0.0 136.0 28.48 .00 3 Double,U=0.82,SHGC=0.70 .5 E 0.0 0.0 76.0 59 (W & 001 �534.9 As -Built Total: 369.0 'y`` 16244.2 WALL TYPES Area X BSPM = Points Type R Valr klue Area X SPM = Points Adjacent 0.0 0.00 Exterior 0.0 Concrete, Int Insul, Exterior 4i1998.2 1.18 �, 2357.9 2722.2 1.90 5172.2 Frame, Wood, Exterior x' �1.1 0 724.0 1.90 1375.E Base Total: 2722.2 5172.2 As -Built Total 2722.2 3733.5 DOOR TYPES Area X BSPM = Points Type, Area X SPM = Points Adjacent 0.0 0.00 Exterior 21.0 4.80 0 ` enor Insulated 21.0 4.80 100.8 100 B Total: 21.0 As -Built Total: 21.0 IBase ���1Q08 100.8 CEILING TYPES Area BSP Points Type R-Value Area XSPM X SCM = Points ,.� _rrq Y SKr Under Attic 65 (t� 2.13 5661.5 Single Assembly 30.0 2658.0 5.40 X 1.00 14353.2 Bas otal 2656E � A 5661.5 As -Built Total: 2658.0 14353.2 FLb.O sTYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 328.4(p) -31.8 0.0 Slab -On -Grade Edge Insulation 0.0 328.4(p -31.90 0.0 Raised 0.0 0.00 0.0 Base Total: 0.0 As -Built Total: 0.0 0.0 INFILTRATION Area X BSPM = Points Area X SPM = Points r- 3599.0 14.31 51501.7 3599.0 14.31 51501-7 EnergyGauge® DCA Form 600A-2004 EnergyGauge@/FlaRES'2004 FLRCSB v4.0 FORM 60OA-2004 EnergyGauge® 4.0 SUMMER CALCULATIONS Residential Whole wilding Performance Method A - Details - ADDRESS: PERMIT #: BASE AS -BUILT Summer Base Points: 79137.0 Summer As -Built Points: 86933.4 Total Summer X System Points = Cooling Total X Cap X Duct X System X Credit = Cooling Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Central Unit 61500 btuh ,SEER/EFF(13.0) Ducts:Unc(S),Unc(R),Gar(AI ),R6 0(If1S) 85933 0.76 0.09 x 1.150 x 0.95) 0.262 1:u�0 37g B (sys 2: Central Unit 19200 btuh ,SEER/EFF(13.0) Ducts:Unc(S),UnC , 79137.0 0.4266 33769.9 85933 0.24 (1.09 x 1.150 x 0.85) 0.262 1p00` 6050.3 85933.4 1.00 1.128 0.262 1, 000 26430.1 4 e", %. U� EnergyGaugeTTM DCA Form 60OA-2004 EnergyGauge®/FlaRES-2004 FLRCSB v4.0 FORM 60OA-2004 EnergyGauge® 4.0 WINTER CALCULATIONS Residential Whole Building. Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 3599.0 5.86 3796.2 Double,U=0.82,SHGC=0.70 W 0.0 0.0 64.0 8.79 1.00 562.6 Double,U=0.82,SHGC=0.70 S 0.0 0.0 72.0 5.85 1.00 421.1 Single,U=1.00,SHGC=0.83 S 0.0 0.0 21.0 6.61 1.00 -138.9 Double,U=0.82,Sh�C=0.70 N 0.0 0.0 136.0 10.31 01 AU 14¢2.1 Double,U=0.82,SHGC=0.70 E 0.0 0.0 76.0 8.0,4s='fit 00 0.7 ( V" As -Built Total: 369.0 3135.5 WALL TYPES Area X BWPM = Points Type YP R-Value-= . eTa X WPM = Points Adjacent 0.0 0.00 Exterior 2722.2 2.00 0.0 5444.4 Concrete, Int Insul, Exterior Frame, 98.2 �rrv. 3.31 6604.1 Wood, Exterior it1.0 724.0 2.00 1448.0 Base Total: 2722.2 5444.4 As -Built Total 2722.2 8052.1 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.9 Exterior Insulated 21.0 5.10 107.1 Exterior 21.0 5.10 107.1 10 Base Total: 21.0 10,7 �1 As -Built Total: 21.0 107.1 CEILING TYPESAreaCBWP $ash Points Type R-Value Area XWPM X WCM = Points c 055$,(h 0.64 � 1?01.1 Single Assembly 30.0 2658.0 0.46 X 1.00 1222.7 [B:a�0T6-ttal., p%-465 0 1701.4 As -Built Total 2658.0 1222.7 FLDRf7YPES. Area X BWPM = Points Type R-Value Area X WPM = Points Slab 328.4(p) -1.9 0.0 Slab -On -Grade Edge Insulation 0.0 328.4(p 2.50 0.0 Raised 0.0 0.00 0.0 Base Total: 0.0 As -Built Total: 0.0 0.0 INFILTRATION Area X BWPM = Points Area X WPM = Points 3599.0 -0.28 -1007.7 3599.0 -0.28-1007.7 EnergyGauge® DCA Form 60OA-2004 EnergyGaugeO/FIaRES'2004 FLRCSB v4.0 FORM 60OA-2004 EnergyGauge® 4.0 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details r ADDRESS: , , , PERMIT #: BASE AS -BUILT Winter Base Points: 10041.1 Winter As -Built Points: 11509.E Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Electric Heat Pump 57500 6tuh ,EFF(B.6) Ducts: Unc(S),Unc(R),Gac(AH( fR6.c0} 11509.6 0.771 (1.078 x 1.160 x G.95) 0.397 1.000 ^4475.13 t (sys 2: Electric Heat Pump 17100 htuh ,EFF(7.1) Ducts:Uncc((S), Unc(R)alnt(AH);R6.0' 10041.1. 0.6274 6299.8 11509.6 0.229 (1.078 x 1.160 x 0.87) 0.481 1?p00 x� `w 1446.3 11509.6 1.00 1.140 0.4131 a00` 5426.1 EnergyGaugelm DCA Form 600A-2004 y EnergyGauge®/FIaRES'2004 FLRCSB v4.0