HomeMy WebLinkAboutPHOTOVOLTAIC SYSTEMCITY NOTES:PV SYSTEM SUMMARY: 11.900 KW SITE LOCATION AND HOUSE AERIAL VIEW THIS PROJECT COMPLIES WITH THE FOLLOWING: 2020 7TH EDITION FLORIDA BUILDING CODE: BUILDING 2020 7TH EDITION FLORIDA BUILDING CODE: RESIDENTIAL 2020 7TH EDITION FLORIDA BUILDING CODE: MECHANICAL 2020 7TH EDITION FLORIDA BUILDING CODE: PLUMBING 2020 7TH EDITION FLORIDA BUILDING CODE: FUEL GAS 2020 7TH EDITION FLORIDA BUILDING CODE: ENERGY CONSERVATION 2020 7TH EDITION FLORIDA BUILDING CODE: EXISTING BUILDING 2020 7TH EDITION FLORIDA BUILDING CODE: ACCESSIBILITY 2020 7TH EDITION FLORIDA FIRE PREVENTION CODE 2017 NATIONAL ELECTRIC CODE (NEC) AS ADOPTED BY COUNTY OF ST. LUCIE PHOTOVOLTAIC SYSTEM SITE LOCATION: HOUSE AERIAL VIEW: SITE LOCATION MODULE LOCATION MAIN SERVICE PANEL : EXISTING 200 AMPS MSP WITH (E) 150 AMPS MAIN BREAKER ON TOP FED INTERCONNECTION : LINE SIDE TAP OCPD RATING : 60 AMPS UTILITY : FLORIDA POWER & LIGHT TILT : 11°, 11° AZIMUTH :166°, 346° RESIDENTIAL PHOTOVOLTAIC SYSTEM SYSTEM SIZE (DC): STC: 34 X 350 = 11900W DC : PTC: 34 X 326.8 = 11111W DC SYSTEM SIZE (AC):10000W AC @ 240V MODULES : 34 X LONGI SOLAR: LR4-60HPB-350M SHEET:TITLE:CLIENT:REVISIONS: DATE: DESIGN BY: JOB NO.: DESCRIPTION DATE REVISIONDONALD DOBBS 753 NORTHEAST CYPRESS STREET, PORT SAINT LUCIE, FL 34952 1/12/2022 JB PV-1 F114037 FREEDOM FOREVERINDY 6.07 TEMPLATEELECTRICAL CONTRACTOR NO: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT OPTIMIZERS : 34 X SOLAR EDGE: P401 INVERTER : SOLAR EDGE: SE10000H-USRGM [SI1] ROOF : COMPOSITION SHINGLE RAFTER/TRUSS SIZE : 2X6 TRUSS @ 24" O.C. ATTACHMENT TYPE : UNIRAC: SFM INFINITY MICRORAIL WITH UNIRAC SFM INFINITY RAIL-LESS ALL SOLAR ENERGY SYSTEM EQUIPMENT SHALL BE SCREENED TO THE MAXIMUM EXTENT POSSIBLE AND SHALL BE PAINTED A COLOR SIMILAR TO THE SURFACE UPON WHICH THEY ARE MOUNTED. INSTALLATION NOTES: MODULES SHALL BE TESTED , LISTED AND INDENTIFIED WITH FIRE CLASSIFICATION IN ACCORDANCE WITH UL 2703. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER SECTION R314 AND 315 TO BE VERIFIED AND INSPECTED BY INSPECTOR IN THE FIELD. CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. DIG ALERT (811) TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY PRIOR TO ANY EXCAVATION TAKING PLACE INSTALL CREW TO VERIFY ROOF STRUCTURE PRIOR TO COMMENCING WORK. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNT. PV-1 SITE LOCATION AND HOUSE AERIAL VIEW PV-2 SITE PLAN PV-2A ROOF PLAN WITH MODULES LAYOUT PV-3 MOUNTING DETAILS PV-4 THREE LINE DIAGRAM PV-5 EXISTING SERVICE PANEL PV-6 NOTES AND EQUIPMENT LIST PV-7 LABELS PV-7A SITE PLACARD PV-8 OPTIMIZER CHART PV-9 & 10 SAFETY PLAN TABLE OF CONTENTS 1 CHANGED MODULE AND LAYOUT 01/12/22 1 MSP UM ACINV JB SITE PLAN SITE PLAN SCALE: 1/16" = 1'-0"1 SITE PLAN PV SYSTEM 11.900 kW-DC 10.000 kW-AC ROOF AREA : 2137.60 SQ FT SHEET:TITLE:CLIENT:REVISIONS: DATE: DESIGN BY: JOB NO.: DESCRIPTION DATE REVISIONDONALD DOBBS 753 NORTHEAST CYPRESS STREET, PORT SAINT LUCIE, FL 34952 1/12/2022 JB PV-2 F114037 FREEDOM FOREVERINDY 6.07 TEMPLATEELECTRICAL CONTRACTOR NO: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT LEGEND: OBSTRUCTION PIPE VENT MODULES CONDUIT SETBACK MSP AC AC DISCONNECT JUNCTION BOX INV INVERTER UM JB MSP UTILITY METER131'-7"87'-8"128' -8 " 61'-6" 7'-8"40'-2"44'-6" 11'-11"DRIVEWAYNORTHE A S T C Y P R E S S S T R E E T (N) JUNCTION BOX ROOF LINE (E) UTILITY METER (N) SE10000H-USRGM [SI1] (N) SQUARE D D222NRB (E) MAIN SERVICE PANEL PROPERTY LINE (N) 34 LONGI SOLAR: LR4-60HPB-350M 1 CHANGED MODULE AND LAYOUT 01/12/22 1 1 MSP UM ACINV JB ROOF PLAN SCALE: 3/32" = 1'-0"1 ROOF AREA STATEMENT ROOF MODULES QTY PITCH AZIMUTH ROOF AREA ARRAY AREA ARRAY COVERAGE % SYSTEM DISTRIBUTED WEIGHT 1 18 11 166°706.15 SQ FT 325.08 SQ FT 28.73% 2.31 PSF 2 16 11 346°825.91 SQ FT 288.96 SQ FT PV SYSTEM 11.900 kW-DC 10.000 kW-AC NOTES: 1. EMT CONDUIT ATTACHED TO THE ROOF USING CONDUIT MOUNTS 2. ATTACHED CLAMPS AT 25% FROM THE EDGE AND 50% FROM THE CENTER OF THE MODULES 3. JUNCTION BOX IS MOUNTED TO THE RAIL. SHEET:TITLE:CLIENT:REVISIONS: DATE: DESIGN BY: JOB NO.: DESCRIPTION DATE REVISIONDONALD DOBBS 753 NORTHEAST CYPRESS STREET, PORT SAINT LUCIE, FL 34952 1/12/2022 JB PV-2A F114037 FREEDOM FOREVERINDY 6.07 TEMPLATEELECTRICAL CONTRACTOR NO: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT ROOF PLAN W/ MODULES LAYOUT ROOF AREA : 2137.6 SQ FT LEGEND: OBSTRUCTION PIPE VENT MODULES CONDUIT SETBACK MSP AC AC DISCONNECT JUNCTION BOX INV INVERTER UM JB MSP UTILITY METER2'-0" 3'-0"2'-0" 3'-0"2'-11"2'-10" FIRE ACCESS PATHWAYS FIRE ACCESS PATHWAYS 1 CHANGED MODULE AND LAYOUT 01/12/22 12'-0"1 1 By Yuri at 12:52:36 PM, 1/12/2022 ROOF DECK / MEMBRANE SFM SLIDER AND TRIMRAIL ROOF ATTACHMENT BUILDING STRUCTURE 5/16" STAINLESS STEEL LAG BOLT OR STRUCTURAL SCREW WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER 2.5" SFM TRIMRAIL 2.5" MIN. EMBED.FLASHING ROOF / DECK MEMBRANE UNIRAC SLIDERS BUILDING STRUCTURE 5/16" STAINLESS STEEL LAG BOLT OR STRUCTURAL SCREW WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER 2.5" SFM MICRORAIL FLASHING 2.5" MIN. EMBED. LONGI SOLAR: LR4-60HPB-350M LONGI SOLAR: LR4-60HPB-350M UNIRAC SLIDERS SFM MICRORAIL 2.5" MI N. E M B E D. 5/16" STAINLESS STEEL LAG BOLT OR STRUCTURAL SCREW WITH 2-1/2" MIN. EMBEDMENT AND FLAT WASHER SFM TRIMRAIL 2.5" MI N. E M B E D. LONGI SOLAR: LR4-60HPB-350M FLASHING FLASHING SFM SLIDER AND TRIMRAIL ROOF ATTACHMENT 2X6 TRUSS @ 24" O.C. ROOF / DECK MEMBRANE 3" M IN .5" MAX . MAX ATTACHMENT SPAN - 4' MOUNTING DETAILS ATTACHMENT DETAIL Scale: NTS SOLAR PV ARRAY SECTION VIEW Scale: NTS PARTIAL ROOF FRAMING PLAN Scale: NTS SHEET:TITLE:CLIENT:REVISIONS: DATE: DESIGN BY: JOB NO.: DESCRIPTION DATE REVISIONDONALD DOBBS 753 NORTHEAST CYPRESS STREET, PORT SAINT LUCIE, FL 34952 1/12/2022 JB PV-3 F114037 FREEDOM FOREVERINDY 6.07 TEMPLATEELECTRICAL CONTRACTOR NO: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT 1 CHANGED MODULE AND LAYOUT 01/12/22 1 1 1 By Yuri at 12:52:38 PM, 1/12/2022 JUNCTION BOX SOLAREDGE P401 POWER OPTIMIZERS STRING-1 2 - #10 AWG, PV WIRE 1 - #6 AWG IN FREE AIR OR #8 AWG MUST BE IN EMT CONDUIT STRING-3 SOLAREDGE P401 POWER OPTIMIZERS 4 - #10 AWG, PV WIRE 1 - #6 AWG IN FREE AIR OR #8 AWG MUST BE IN EMT CONDUIT 12 LONGI SOLAR: LR4-60HPB-350M 11 LONGI SOLAR: LR4-60HPB-350M STRING-2 11 LONGI SOLAR: LR4-60HPB-350M 2 - #10 AWG, PV WIRE SOLAREDGE P401 POWER OPTIMIZERS 6 - #10 AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT UM (E) 150A / 2P MAIN BREAKER (END FED) (E) 200A RATED MAIN SERVICE PANEL 1PH, 120/240V 60HZ (E) UTILITY METER (N) LINESIDE TAP VIA UL LISTED CONNECTORS 1 - #6 GEC, BARE COPPER FREE AIR BONDED EXISTING UFER TIE IN TO UTILITY OVERHEAD FEED (N) 60A FUSED AC DISCONNECT SQUARE D D222NRB 2 - 60 AMP FUSES 3 - #6 AWG, THWN-2 1 - #8 EGC, THWN-2 IN 3/4" OR LARGER EMT CONDUIT A TAPBOX MAY BE USED IN LIEU OF PERFORMING THE LINESIDE TAP IN THE MAIN SERVICE PANEL. THIS IS DEPENDENT UPON SITE CONDITIONS. 3 - #6 AWG, THWN-2 IN 3/4" OR LARGER EMT CONDUIT (N) SOLAREDGE SE10000H-USRGM [SI1] INVERTER AC DC RAPID SHUTDOWN SWITCH CONNECT TO EXISTING UFER THREE LINE DIAGRAM NOTE: CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS BACKFEED FUSE SIZING MAX. CONTINUOUS OUTPUT 42A @ 240V 42.00 X 1.25 = 53AMPS 60A FUSES - OK CONDUCTOR AMPACITY DE-RATE CALCULATION EQUIPMENT WIRE LOCATION CONDUCTOR QTY. AWG WIRE SIZE NEC FACTORS TABLE 310.15(B)(16) NEC FACTORS TABLE 310.15(B)(2)(a) CONDUCTOR AMPACITY @90C ADJ. NEC FACTORS TABLE 310.15(B)(3)(a) 1 AC INVERTER TO AC DISCONNECT EXTERIOR WALL 3 6 65 0.94 61.1 1.00 2 AC AC DISCONNECT TO POI EXTERIOR WALL 3 6 65 0.94 61.1 1.00 PV SYSTEM 11.900 kW-DC 10.000 kW-AC SHEET:TITLE:CLIENT:REVISIONS: DATE: DESIGN BY: JOB NO.: DESCRIPTION DATE REVISIONDONALD DOBBS 753 NORTHEAST CYPRESS STREET, PORT SAINT LUCIE, FL 34952 1/12/2022 JB PV-4 F114037 FREEDOM FOREVERINDY 6.07 TEMPLATEELECTRICAL CONTRACTOR NO: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT 1 CHANGED MODULE AND LAYOUT 01/12/22 1 1 EXISTING SERVICE PANEL SHEET:TITLE:CLIENT:REVISIONS: DATE: DESIGN BY: JOB NO.: DESCRIPTION DATE REVISIONDONALD DOBBS 753 NORTHEAST CYPRESS STREET, PORT SAINT LUCIE, FL 34952 1/12/2022 JB PV-5 F114037 FREEDOM FOREVERINDY 6.07 TEMPLATEELECTRICAL CONTRACTOR NO: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT NOTES AND EQUIPMENT LIST MATERIAL LIST: SHEET:TITLE:CLIENT:REVISIONS: DATE: DESIGN BY: JOB NO.: DESCRIPTION DATE REVISIONDONALD DOBBS 753 NORTHEAST CYPRESS STREET, PORT SAINT LUCIE, FL 34952 1/12/2022 JB PV-6 F114037 FREEDOM FOREVERINDY 6.07 TEMPLATEELECTRICAL CONTRACTOR NO: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT QTY.PART PART # DESCRIPTION 34 MODULES 114-350 LONGI SOLAR: LR4-60HPB-350M 34 OPTIMIZERS 130-401 P401 SOLAREDGE POWER OPTIMIZER - FRAME MOUNTED MODULE ADD-ON 1 JUNCTION BOX 480-276 600VDC NEMA 3R UL LISTED JUNCTION BOX 2 CONNECTORS 240-300 STAUBLI / MULTI-CONTACT MC4 CONNECTORS (FEMALE) 2 CONNECTORS 240-301 STAUBLI / MULTI-CONTACT MC4 CONNECTORS (MALE) 1 INVERTER 120-103 SE10000H-USRGM [SI1] 240V INVERTER UL1741 SA CERTIFIED INTEGRATED ARC FAULT PROTECTION AND RAPID SHUTDOWN 1 AC DISCONNECT 323-065 60A RATED 240VAC NEMA 3R UL LISTED 2 FUSES 330-060 60A FUSE 1 PH 240VAC 1 FUSE REDUCER 330-510 100A-60A FUSE REDUCER 1 TAP KIT 350-111 #6 - 3/0 AWG INSULATED TAP 2 PORT 62 ROOF ATTACHMENT 1 261-602 UNIRAC: SFM INFINITY MICRORAIL 59 MICRORAIL 1 261-602 SFM MICRORAIL 2 INCH 25 SFM TRIM 1 241-253 FLASHKIT SFM TRIM COMP DARK 64 SFM SLIDER 1 261-603 FLASHKIT SFM SLIDER COMP DARK 19 BONDING CLAMP 1 221-100 SFM N/S BONDING CLAMP 8 BONDING CLAMP 1 241-404 SFM TRIM BONDING CLAMP 36 MOUNT ASSEMBLY 1 241-405 MLPE MOUNT ASSY 21 SFM SPLICE 1 261-604 SFM SPLICE 5 SFM ATTACHED SPLICE 1 211-101 SFM ATTACHED SPLICE 8 INCH 28 TRIMRAIL 1 261-606 SFM TRIMRAIL UNIV CLIP W/ HDW 9 TRIM SPLICE 1 261-605 SFM TRIM SPLICE DRK 15 TRIMRAIL 1 211-115 SFM TRIMRAIL UNIV DRK 34 GROUND LUG 1 260-585 ILSCO GROUND LUG 34 TRIM END CAPS 1 UNIRAC SFM TRIM END CAPS GENERAL NOTES: 34 LONGI SOLAR WIRED AND LISTED TO UL1703 STANDARDS THE SOLAREDGE INVERTER IS INTEGRATED WITH DC DISCONNECTION AND ARC FAULT PROECTION. IT IS ATTACHED WITH SYSTEM ELECTRICAL SPECIFICATIONS W/ GROUND FAULT PROTECTION & LISTED TO UL 1741 STANDARDS. PHOTOVOLTAIC SYSTEM GROUND WILL BE TIED INTO EXISTING GROUND AT MAIN SERVICE FROM DC DISCONNECT/INVERTER AS PER 2017 NEC SEC 250.166(A). SOLAR PHOTOVOLTAIC SYSTEM EQUIPMENT WILL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF ART. 690 OF THE 2017 NEC CONDUIT ABOVE ROOF SHALL BE NO LESS THAN 1 INCH FROM TOP OF THE ROOF TO BOTTOM OF RACEWAY. TABLE NEC 310.15(B)(3)(C) PHOTOVOLTAIC DC CONDUCTORS ENTERING THE BUILDING SHALL BE INSTALLED IN METALLIC RACEWAY AND SHALL BE IDENTIFIED EVERY 10 FEET -- AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES WALLS OR BARRIERS -- WITH MINIMUM 3/8-INCH-HIGH WHITE LETTERING ON RED BACKGROUND READING: WARNING: PHOTOVOLTAIC POWER SOURCE. SYSTEM GROUNDING ELECTRODE CONDUCTOR FOR PV SYSTEM TO BE SIZED TO MEET THE REQUIREMENTS OF 2017 NEC THE EXISTING MAIN SERVICE PANEL WILL BE EQUIPPED WITH A GROUND ROD OR UFER UTILITY COMPANY WILL BE NOTIFIED PRIOR TO ACTIVIATION OF THE SOLAR PV SYSTEM TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION SOLAREDGE INVERTERS ARE LISTED TO UL 1741 AND UL 1699B STANDARDS SOLAREDGE OPTIMIZERS ARE LISTED TO IEC 62109-1 (CLASS II SAFETY) AND UL 1741 STANDARDS BREAKER SIZES: SERVICE: 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C. AERIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 3. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. NOTES: M 690.54 705.12(B)(2)(3)(b) "WARNING" DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT - 42.00 AMPS AC NORMAL OPERATING VOLTAGE - 240 VOLTS WARNING: POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY 690.56(C)(1)(A) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN AC 690.15, 690.54 PV SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT - 42.00 AMPS AC NORMAL OPERATING VOLTAGE - 240 VOLTS RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 690.56(C)(3) INVERTER ARRAY J/BDC "WARNING" PHOTOVOLTAIC POWER SOURCE EVERY 10' ON CONDUIT AND ENCLOSURES "WARNING" ELECTRICAL SHOCK HAZARD. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 690.13 (B) 690.53 PV SYSTEM DC DISCONNECT MAXIMUM VOLTAGE: 480V MAXIMUM CIRCUIT CURRENT: 42A MAX RATED OUTPUT CURRENT OF THE CONTROLLER OR DC-TO-DC CONVERTER: 15A NEC 690.31(G)(3) & (4)PMPV METER SOLAR ELECTRIC PV PANELS SHEET:TITLE:CLIENT:REVISIONS: DATE: DESIGN BY: JOB NO.: DESCRIPTION DATE REVISIONDONALD DOBBS 753 NORTHEAST CYPRESS STREET, PORT SAINT LUCIE, FL 34952 1/12/2022 JB PV-7 F114037 FREEDOM FOREVERINDY 6.07 TEMPLATEELECTRICAL CONTRACTOR NO: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT LABELS MSP UM ACINV JB NOTES: 1. NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS SHOWN HEREON. 2. ALL MARKING SHALL CONSIST OF THE FOLLOWING: A. UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B. RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C. AERIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 3. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. SITE PLACARD CAUTION: MULTIPLE SOURCES OF POWER LOCATED AS SHOWN. DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES 6X8" TYP - NEC 705.10 SHEET:TITLE:CLIENT:REVISIONS: DATE: DESIGN BY: JOB NO.: DESCRIPTION DATE REVISIONDONALD DOBBS 753 NORTHEAST CYPRESS STREET, PORT SAINT LUCIE, FL 34952 1/12/2022 JB PV-7A F114037 FREEDOM FOREVERINDY 6.07 TEMPLATEELECTRICAL CONTRACTOR NO: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT NORTHEA S T C Y P R E S S S T R E E T MAIN SERVICE PANEL INVERTER EQUIPPED WITH RAPID SHUTDOWN JUNCTION BOX 34 PV MODULE AC DISCONNECT UTILITY METER 1 CHANGED MODULE AND LAYOUT 01/12/22 1 1 2 3 4 5 6 7 8 9 10 1-10 11-20 21-30 31-40 41-50 51-60 1 2 3 4 5 6 7 8 9 10 1-10 11-20 21-30 31-40 41-50 51-60 SHEET:TITLE:CLIENT:REVISIONS: DATE: DESIGN BY: JOB NO.: DESCRIPTION DATE REVISIONDONALD DOBBS 753 NORTHEAST CYPRESS STREET, PORT SAINT LUCIE, FL 34952 1/12/2022 JB PV-8 F114037 FREEDOM FOREVERINDY 6.07 TEMPLATEELECTRICAL CONTRACTOR NO: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT SOLAREDGE OPTIMIZER CHART OPTIMIZER CHART NORTHEA S T C Y P R E S S S T R E E T SAFETY PLAN SAFETY PLAN MARK UP KEY INSTRUCTIONS: 1. USE SYMBOLS IN KEY TO MARK UP THIS SHEET. 2. SAFETY PLAN MUST BE MARKED BEFORE JOB STARTS AS PART OF THE PRE-PLAN 3. DOCUMENT ALL ADDITIONAL HAZARDS ON THIS PAGE & MAKE NOTES ON THE JHA SHEET IN CASE OF EMERGENCY NEAREST HOSPITAL OR OCCUPATIONAL/INDUSTRIAL CLINIC NAME: _______________________________________________ ADDRESS: ___________________________________________ SAFETY COACH CONTACT INFORMATION NAME: _______________________________________________ ADDRESS: ___________________________________________ ALL EMPLOYEES ON SITE SHALL BE MADE AWARE OF THE SAFETY PLAN AND SIGN INDICATING THAT THEY ARE AWARE OF THE HAZARDS ON-SITE AND THE PLAN FOR WORKING SAFELY. NAME SIGNATURE __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ __________ ________________ DATE: ______________ TIME:___________________________ PERMANENT ANCHOR TEMPORARY ANCHOR INSTALLER LADDER JUNCTION / COMBINER BOX STUB-OUT SKYLIGHT NO LADDER ACCESS (STEEP GRADE OR GROUND LEVEL OBSTRUCTIONS) RESTRICTED ACCESS CONDUIT GAS SHUT OFF WATER SHUT OFF SERVICE DROP POWER LINES P T IL B S 7 Z GAS H2O SHEET:TITLE:CLIENT:REVISIONS: DATE: DESIGN BY: JOB NO.: DESCRIPTION DATE REVISIONDONALD DOBBS 753 NORTHEAST CYPRESS STREET, PORT SAINT LUCIE, FL 34952 1/12/2022 JB PV-9 F114037 FREEDOM FOREVERINDY 6.07 TEMPLATEELECTRICAL CONTRACTOR NO: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT NORTHEA S T C Y P R E S S S T R E E T JOB HAZARD ANALYSIS Crew leader to fill out all sections below, hold a pre-job safety meeting with all personnel, and upload this completed document and the Safety Plan to Site Capture Ladder Access x Ladders must be inspected before each use. x Extension ladders must be set up on a firm and level surface at a 4-to-1 rise to run angle (or 75 degrees) and the top must be secured to the structure. Extension style ladders placed on uneven, loose or slippery surfaces must additionally have the base firmly anchored or lashed so the base will not slip out. x Extension ladders must be used with walk-through devices or the ladder must extend 36" above the stepping off point. x A-frame ladders must only be climbed with the ladder spreader bars locked in the open position; A-frame ladders shall not be climbed while in the closed position (ex, closed and used while leaned against a structure). x Additional notes: Mobile Equipment x Only Qualified operators will operate equipment; operators must maintain a certification on their person for the equipment being operated. x Type(s) of mobile equipment (Type/Make/Model): x Qualified operator(s): Material Handling and Storage x Materials will be staged/stored in a way that does not present a hazard to client, personnel or public. Materials stored on the roof will be physically protect from failing or sliding off. Fall Protection x A site-specific plan for fall prevention and protection is required prior to starting work and must remain onsite at all times until work is complete; a fall rescue plan must be outlined and discussed among the crew prior to work start. x First-person-Up (FPU) must install their anchor and connect before any other task, including installing other anchors. The Last-Person-Down (LPD) must be the only person on a roof uninstalling fall protection. x FPCP (name and title): x FPU and LPD (name and title): Electrical Safety x The Electrical Qualified Person (EQP) is required onsite to perform electrical work. x All electrical work will be performed with equipment in an electrically safe condition (de-energized) unless approval has been granted prior to work. x Service drops and overhead electrical hazards will be indentified and protected from contact, as neccessary. x EQP (name and tile): Public Protection x The safety of the Client and the Public must be maintained at all times. x The Client and the Public shall be prevented from entering the work zone through the use of barriers and/or signage, as required. x Company, Client and Public property shall be protect from falling objects. x Pets (including dogs) shall be secured by their owners prior to work start. x The client should not leave pets, family members, or others in the charge or care of Employees, Contractors, or Temporary Workers. x Crew leader responsible for communication with the client: x Client and public is excluded from work area by barricades (N/A, Yes, No): Training and Pre-Job Safety Briefing x All employees onsite shall be made aware of the specific hazards of this project and review this HJA during a pre-job briefing, and their signature indicates awareness of site conditions and the plan to eliminate any hazards identified prior to and during the project. x Crew leader (name/title): x Crew member (name/title): x Crew member (name/title): x Crew member (name/title): x Crew member (name/title): x Crew member (name/title): Airborne Contaminants: x Asbestos-containing (Transite) piping (ACP) - Do not disturb (move, drill, cut fracture, etc.) x Asbestos-containing thermal insulation (ACI) and Asbestos-containing duct wrapping (ACW) - do not disturb, no attic or crawlspace access is allowed if work to be performed could cause exposure to personnel, client or public. x If yes, list specific tasks and protection in place: Weather and Environment x The site supervisor shall forecast the weather conditions at the job site, prior to crew arrival, in order to mitigate any hazards associated with inclement weather (heat, cold, wind, rain, etc.) x The site supervisor will utilized a portable wind meter (anemometer) to verify actual onsite wind conditions, by checking at the ground and on any elevated work surface (ex, rooftop) prior to work start, at midday and prior to solar panel staging on a roof. x Elevated work involving the moving or maneuvering of solar panels shall cease at 25mph (sustained wind) until wind subsides. x Forecasted weather maximum temp (degrees F): Heat Related Illness Prevention x Employees shall have access to potable drinking water that is fresh, pure, and suitably cool. The water shall be located as close as practicable to the areas where employees are working. Water shall be supplied in sufficient quantity at the beginning of the work shift to provide at least one quart per employee per hour for drinking for the entire shift. Employees may begin the shift with smaller quantities of water if they identify the location and have effective means for replenishment during the shift to allow employees to drink on quart or more per hour. The frequent drinking of water shall be encouraged. x Shade shall be present when temperature exceeds 80 degrees Fahrenheit. When the outdoor temperature in the work exceeds 80 degrees Fahrenheit, employees shall have and maintain one or more areas with shade at all times. x New employees must be acclimatized. New employees will be monitored by their Crew Leader (site supervisor) for the first two (2) weeks of employment or longer when necessary. x Employees will be allowed and encouraged to implement scheduled breaks during each shift. Employees must take cool-down breaks in the shade any time they feel the need to do so to protect them from overheating. Supervisors are REQUIRED to allow employees any break period they need during high heat conditions. x Cool Vests are encouraged for all employees at all times during periods of high heat. x Identify the location of the closet Occupational/Industrial Clinic or Hospital in case a crew member becomes ill. What is the specific plan to provide and replenish sufficient water for all employees on site? x If offsite replenish is necessary, where will you go to replenish water (location/address): x Who will replenish the drinking water (name): Restroom facilities x Employees shall have access to restroom facilities with hand-washing stations. Use of onsite restroom is at the client's discretion (location is annotated below). If client does not give permission, location of suitable restroom facilities with hand-washing stations offsite will be provided. The onsite supervisor will identify location and make arrangements to ensure all employees have access at any point. x Restroom facilities will be (circle one): Onsite - Offsite x If Offsite, add location name and address: Incident Reporting Procedure x Contact your Site Supervisor Name: Phone: x Contact your Manager Name: Phone: x Contact your Site Supervisor Name: Phone: With: Your full name, phone number, office location, brief description of what happen and when. NOTE ADDITIONAL HAZARDS NOT ADDRESSED ABOVE (add as many as necessary by using additional sheets) Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: Define the Hazard:Method/steps to prevent incident: SHEET:TITLE:CLIENT:REVISIONS: DATE: DESIGN BY: JOB NO.: DESCRIPTION DATE REVISIONDONALD DOBBS 753 NORTHEAST CYPRESS STREET, PORT SAINT LUCIE, FL 34952 1/12/2022 JB PV-10 F114037 FREEDOM FOREVERINDY 6.07 TEMPLATEELECTRICAL CONTRACTOR NO: CERTIFIED ELECTRICAL CONTRACTOR EC13008056 FREEDOM FOREVER FLORIDA LLC 2619 CONSULATE DR SUITE 800, ORLANDO, FL 32819 Tel: (800) 385-1075 GREG ALBRIGHT SAFETY PLAN FREEDOM FOREVERINDY 6.04 TEMPLATE POWER OPTIMIZERsolaredge.com PV power optimization at the module-level 6SHFLÀFDOO\GHVLJQHGWRZRUNZLWK6RODU(GJH LQYHUWHUV 8SWRPRUHHQHUJ\ )OH[LEOHV\VWHPGHVLJQIRUPD[LPXPVSDFH XWLOL]DWLRQ )DVWLQVWDOODWLRQZLWKDVLQJOHEROW 1H[WJHQHUDWLRQPDLQWHQDQFHZLWKPRGXOH OHYHOPRQLWRULQJ 0HHWV1(&UHTXLUHPHQWVIRUDUFIDXOW SURWHFWLRQ $)&, DQG3KRWRYROWDLF5DSLG 6KXWGRZQ6\VWHP 39566 0RGXOHOHYHOYROWDJHVKXWGRZQIRULQVWDOOHU DQGÀUHÀJKWHUVDIHW\ 6XSHULRUHIÀFLHQF\  0LWLJDWHVDOOW\SHVRIPRGXOHPLVPDWFKORVVHV IURPPDQXIDFWXULQJWROHUDQFHWRSDUWLDO VKDGLQJ Power Optimizer For North America 33333333 25 YEARWARRANTY  )RUGHWDLOHGᐎULQJVL]LQJLQIRUPDWLRQUHIHUWRKWWSZZZVRODUHGJHFRPVLWHVGHIDXOWÀOHVᐎULQJBVL]LQJBQDSGI  ,WLVQRWDOORZHGWRPL[333ZLWK33333LQRQHᐎULQJ  $ᐎULQJZLWKPRUHWKDQRSWLPL]HUVGRHVQRWPHHW1(&UDSLGVKXWGRZQUHTXLUHPHQWVVDIHW\YROWDJHZLOOEHDERYHWKH9UHTXLUHPHQW  )RU9JULGLWLVDOORZHGWRLQᐎDOOXSWR:SHUᐎULQJZKHQWKHPD[LPXPSRZHUGL੔HUHQFHEHWZHHQHDFKᐎULQJLV:  )RU9JULGLWLVDOORZHGWRLQᐎDOOXSWR:SHUᐎULQJZKHQWKHPD[LPXPSRZHUGL੔HUHQFHEHWZHHQHDFKᐎULQJLV: Œ6RODU(GJH7HFKQRORJLHV/WG$OOULJKWVUHVHUYHG62/$5('*(WKH6RODU(GJHORJR237,0,=('%<62/$5('*(DUHWUDGHPDUNVRUUHJLVWHUHGWUDGHPDUNVRI6RODU(GJH7HFKQRORJLHV,QF $OORWKHUWUDGHPDUNVPHQWLRQHGKHUHLQDUHWUDGHPDUNVRIWKHLUUHVSHFWLYHRZQHUV'DWH9(1*1$06XEMHFWWRFKDQJHZLWKRXWQRWLFH Power Optimizer For North America 33333333 Optimizer model (typical module compatibility) P320 (for 60-cell modules) P340 (for high- power 60-cell modules) P370 (for higher- power 60 and 72- cell modules) P400 (for 72 & 96-cell modules) P401 (for high power 60 and 72 cell modules) P405 (for high- voltage modules) P485 (for high- voltage modules) P505 (for higher current modules) INPUT 5DWHG,QSXW'&3RZHU   : $EVROXWH0D[LPXP,QSXW9ROWDJH 9RFDWORZHᐎWHPSHUDWXUH     9GF 03372SHUDWLQJ5DQJH       9GF 0D[LPXP6KRUW&LUFXLW&XUUHQW (Isc)     $GF 0D[LPXP(੕FLHQF\% :HLJKWHG(੕FLHQF\  % 2YHUYROWDJH&DWHJRU\II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) 0D[LPXP2XWSXW&XUUHQW  $GF 0D[LPXP2XWSXW9ROWDJH   9GF OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) 6DIHW\2XWSXW9ROWDJHSHU3RZHU 2SWLPL]HU ” 9GF STANDARD COMPLIANCE (0&)&&3DUW&ODVV%,(&,(& 6DIHW\,(& FODVV,,VDIHW\ 8/ 0DWHULDO 8/9895HVLᐎDQW 5R+6 Yes INSTALLATION SPECIFICATIONS 0D[LPXP$OORZHG6\ᐎHP 9ROWDJH  9GF &RPSDWLEOHLQYHUWHUV $OO6RODU(GJH6LQJOH3KDVHDQG7KUHH3KDVHLQYHUWHUV 'LPHQVLRQV :[/[+ [[[[ [[ [[ [[ [[[[[[[[ [[ mm LQ :HLJKW LQFOXGLQJFDEOHV      JUOE ,QSXW&RQQHFWRU 0&  6LQJOHRUGXDO 0&   0&  ,QSXW:LUH/HQJWK  PIW 2XWSXW:LUH7\SH&RQQHFWRU 'RXEOH,QVXODWHG0& 2XWSXW:LUH/HQJWK   PIW 2SHUDWLQJ7HPSHUDWXUH5DQJH  Ü&Ü) 3URWHFWLRQ5DWLQJ ,31(0$3 5HODWLYH+XPLGLW\%  5DWHGSRZHURIWKHPRGXOHDW67&ZLOOQRWH[FHHGWKHRSWLPL]HU´5DWHG,QSXW'&3RZHUµ0RGXOHVZLWKXSWRSRZHUWROHUDQFHDUHDOORZHG  1(&UHTXLUHVPD[LQSXWYROWDJHEHQRWPRUHWKDQ9  )RURWKHUFRQQHFWRUW\SHVSOHDVHFRQWDFW6RODU(GJH  )RUGXDOYHUVLRQIRUSDUDOOHOFRQQHFWLRQRIWZRPRGXOHVXVH310'050,QWKHFDVHRIDQRGGQXPEHURI39PRGXOHVLQRQHᐎULQJLQᐎDOOLQJRQH3GXDOYHUVLRQSRZHURSWLPL]HUFRQQHFWHG WRRQH39PRGXOH:KHQFRQQHFWLQJDVLQJOHPRGXOHVHDOWKHXQXVHGLQSXWFRQQHFWRUVZLWKWKHVXSSOLHGSDLURIVHDOV  )RUDPELHQWWHPSHUDWXUHDERYHƒ&ƒ)SRZHUGHUDWLQJLVDSSOLHG5HIHUWR3RZHU2SWLPL]HUV7HPSHUDWXUH'H5DWLQJ7HFKQLFDO1RWHIRUPRUHGHWDLOV PV System Design Using a SolarEdge Inverter(6)(7) Single Phase HD-Wave Single phase Three Phase for 208V grid Three Phase for 277/480V grid 0LQLPXP6WULQJ/HQJWK 3RZHU2SWLPL]HUV  333 33 3336  0D[LPXP6WULQJ/HQJWK 3RZHU2SWLPL]HUV     0D[LPXP3RZHUSHU6WULQJ  ZLWK 6(866( 86   (9)  : 3DUDOOHO6WULQJVRI'L੔HUHQW/HQJWKVRU2ULHQWDWLRQV Yes FREEDOM FOREVERINDY 6.04 TEMPLATE FREEDOM FOREVERINDY 6.04 TEMPLATE FREEDOM FOREVERINDY 6.04 TEMPLATE FREEDOM FOREVERINDY 6.04 TEMPLATE FREEDOM FOREVERINDY 6.04 TEMPLATE FREEDOM FOREVERINDY 6.04 TEMPLATE