HomeMy WebLinkAboutInsulation Information. 4 BUILDING ENVELOPE SYSTEMS ' ,COMPL.IANCE CHECK �.%---GLAZING--ZONE 1------------------------------------------- -'-----=-v`, / E1 tion Type U SC VLT Shading Area(Sgft.);< -ev-,�------------------- ---- ---- ----=-----=- ------ ---------- North Commercial. 1.31 .35 .65 None .,, 16 • Total Glass Area in Zone: 1 = 1.61. Total Gl"a;ss Area 402.------WALLS--ZONE. 1----------------------=---------='---- Elevation Type U I`-nsul R Gross,(Sgft)';. ------------------------------- .--=-------- _--------- ----------� North 8 "CMU/3/4"ISO Btwn .24�1 `v"Gyp 0 ..1:51 South 8 "CMU/3/4" ISO Btwn 24"'6c/5/8 "Gyp 0 .'1,51.' :` 4 550 ;. East 8 "CMU/3/4" ISO Btwn 24 "oc/5/8 "Gyp 4 160 „0„4:1`5'l West, 811CMU/3/411ISO Btwn 2411oc/5/81'Gyp';" 0..151 4 .160: Total. Waa11 Area in Zone 1 = 1420: Total Gross Wall Area = 1420: 403.------DOORS--ZONE I -------------------------------------------------- Elevation, Type U Area(Sgft) -----------------------------=--------------=------ ----- ---------- South 1.75 ALUM FRAME/_GLASS .81 21 Total Door Area in Zone 1 = 21 Total Door Area = 21 404.------ROOFS=-ZONE 1--------------- ------------- ,---=-----------------;--- Type ,-.Color U Insul R ------ ------------ Area(Sgft) -----=----' ------------------------------------ Sngl Ply/2"ISO/Precast Hollow C ..Medium .-057 .14 , 880 Total Roof Area in Zone 1 = 880 Total Roof Area = 880 405.------FLOORS-ZONE. 1----------------------------------------- -------'--- Type Insul R Area(Sgft), Slab on Grade/Uninsulated 4 880 Total Floor Area in Zone 1 = 880 Total Floor Area = 880 406--- ---- INFILTRATION ------------------------- ----==---------^------- --------,'--- .'CHECK' Infiltration Criteria in 406.1.ABCD.have been met... MECHANICAL SYSTEMS CHECK --=------------------------=--------------------------------------'-----'--- HVAC load sizing has been performed. (407.1.ABCD) 407. ----COOLING SYSTEMS-----------------------------------------------'--- Type No Efficiency IPLV, Tons, ----------------- - ----- ---- ------------- -------------------,. L , 1..Split System 1 11 10 5.01,"0; 408.------HEATING SYSTEMS ---------------=---------=-------------------.--;-.-- Type No Efficiency BTU/hr 1: Electric Resistance 1 10 .27500 =. 409.------VENTILATION---------------------------------------------- --;--- ;CHECK, Ventilation'Criteria in 409.1.ABCD.have been met. 410------ AIR DISTRIBUTION SYSTEM -------------------------------- CHECK, l izing and design have been performed. (410.1:ABCD) ype Duct Location " R-value; ---------------------- =- --------------------- ------ -----' Conditioners With Insulated Roof 7, CHECK: ------------- 7-7--=--------------------- ----7---- 7------------,----_-,--- Testing and balancing will be performed..(410.1.ABCD).' ' 411------ PUMPS AND .PIPING -ZONE ------------------ ----------------- Basic -prescriptive requirements in 4il.l.ABCD have been met. PLUMBING SYSTEMS . '411.--=-PUMPS AND PIPING -ZONE I -------------- Type R-,value/in Diameter Thickness,' - , 1. Non -Circulating 4 .75-: 2; 412.=`--,--WATER HEATING SYSTEMS -ZONE 1-----=--=-=-----------------------;--- Type Efficiency StandbyLoss InputRate Gallons; -----------------=--------------------------------- -- ---._ 1. <=12.kW 18.3 0 9350 6, ELECTRICAL SYSTEMS CHECK; 413------ ELECTRICAL.'POWER DISTRIBUTION-- ----------`=--=---= ---;---;-== Metering criteria in 413.1.ABCD have been'met. ; 414:----7MOTORS--=---=-------=----=-----=----=.- -:=------ -------;-----;-- Motor.efficiencies in'414..1.ABCD have --been. met: 415 . =-=--.LIGHTING SYSTEMS -ZONE .._1---=-.-=-----.-.=,.=-:- =------.------=-- Space. -Type, -!NO Control Type 1 No; Control Type 2- No Watts Area(Sgft.); --- ------ ---==------= =--- ----------- --- -,-' Reading,,,T,. 1 On/Off 3 None 0 960 8.80 Total Watts for Zone 1 = 960;: .-Total Area 'for Zone, 1 = 880 'Total Watts = 960 -Total Area = 880; .. ;CHECK; Lighting criteria -in 415.1.ABCD.have been::me.t. 16:. Operation/maintenance. manual will be provided ­,to owner. (10.2. 1-.)