BUILDING ENVELOPE SYSTEMS
'
,COMPL.IANCE
CHECK
�.%---GLAZING--ZONE 1------------------------------------------- -'-----=-v`,
/
E1 tion Type U SC VLT Shading
Area(Sgft.);<
-ev-,�------------------- ---- ---- ----=-----=- ------
----------
North Commercial. 1.31 .35 .65 None
.,, 16
• Total Glass Area in Zone: 1 =
1.61.
Total Gl"a;ss Area
402.------WALLS--ZONE. 1----------------------=---------='----
Elevation Type U I`-nsul R Gross,(Sgft)';.
------------------------------- .--=-------- _---------
----------�
North 8 "CMU/3/4"ISO Btwn .24�1 `v"Gyp 0 ..1:51
South 8 "CMU/3/4" ISO Btwn 24"'6c/5/8 "Gyp 0 .'1,51.' :` 4
550 ;.
East 8 "CMU/3/4" ISO Btwn 24 "oc/5/8 "Gyp 4
160
„0„4:1`5'l
West, 811CMU/3/411ISO Btwn 2411oc/5/81'Gyp';" 0..151 4
.160:
Total. Waa11 Area in Zone 1 =
1420:
Total Gross Wall Area =
1420:
403.------DOORS--ZONE I --------------------------------------------------
Elevation, Type U
Area(Sgft)
-----------------------------=--------------=------ -----
----------
South 1.75 ALUM FRAME/_GLASS .81
21
Total Door Area in Zone 1 =
21
Total Door Area =
21
404.------ROOFS=-ZONE 1--------------- ------------- ,---=-----------------;---
Type ,-.Color U Insul R
------ ------------
Area(Sgft)
-----=----'
------------------------------------
Sngl Ply/2"ISO/Precast Hollow C ..Medium .-057 .14
,
880
Total Roof Area in Zone 1 =
880
Total Roof Area =
880
405.------FLOORS-ZONE. 1-----------------------------------------
-------'---
Type Insul R
Area(Sgft),
Slab on Grade/Uninsulated 4
880
Total Floor Area in Zone 1 =
880
Total Floor Area =
880
406--- ---- INFILTRATION ------------------------- ----==---------^------- --------,'---
.'CHECK'
Infiltration Criteria in 406.1.ABCD.have been met...
MECHANICAL SYSTEMS
CHECK
--=------------------------=--------------------------------------'-----'---
HVAC load sizing
has been performed. (407.1.ABCD)
407. ----COOLING SYSTEMS-----------------------------------------------'---
Type No Efficiency IPLV, Tons,
----------------- - ----- ---- ------------- -------------------,.
L ,
1..Split System 1 11 10 5.01,"0;
408.------HEATING SYSTEMS ---------------=---------=-------------------.--;-.--
Type No Efficiency BTU/hr
1: Electric Resistance 1 10 .27500
=.
409.------VENTILATION---------------------------------------------- --;---
;CHECK,
Ventilation'Criteria in 409.1.ABCD.have been met.
410------ AIR DISTRIBUTION SYSTEM --------------------------------
CHECK,
l
izing and design have been performed. (410.1:ABCD)
ype Duct Location " R-value;
---------------------- =- --------------------- ------ -----'
Conditioners With Insulated Roof 7,
CHECK:
------------- 7-7--=--------------------- ----7---- 7------------,----_-,---
Testing and balancing will be performed..(410.1.ABCD).' '
411------ PUMPS AND .PIPING -ZONE ------------------ -----------------
Basic -prescriptive requirements in 4il.l.ABCD have been met.
PLUMBING SYSTEMS .
'411.--=-PUMPS AND PIPING -ZONE I --------------
Type R-,value/in Diameter Thickness,'
- ,
1. Non -Circulating 4 .75-: 2;
412.=`--,--WATER HEATING SYSTEMS -ZONE 1-----=--=-=-----------------------;---
Type Efficiency StandbyLoss InputRate Gallons;
-----------------=--------------------------------- -- ---._
1. <=12.kW 18.3 0 9350 6,
ELECTRICAL SYSTEMS
CHECK;
413------ ELECTRICAL.'POWER DISTRIBUTION-- ----------`=--=---= ---;---;-==
Metering criteria in 413.1.ABCD have been'met. ;
414:----7MOTORS--=---=-------=----=-----=----=.- -:=------ -------;-----;--
Motor.efficiencies in'414..1.ABCD have --been. met:
415 . =-=--.LIGHTING SYSTEMS -ZONE .._1---=-.-=-----.-.=,.=-:- =------.------=--
Space. -Type, -!NO Control Type 1 No; Control Type 2- No Watts Area(Sgft.);
--- ------ ---==------= =--- ----------- --- -,-'
Reading,,,T,. 1 On/Off 3 None 0 960 8.80
Total Watts for Zone 1 = 960;:
.-Total Area 'for Zone, 1 = 880
'Total Watts = 960
-Total Area = 880;
.. ;CHECK;
Lighting criteria -in 415.1.ABCD.have been::me.t.
16:. Operation/maintenance. manual will be provided ,to owner. (10.2. 1-.)