Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Efficiency 2
External Lighting Compliance Description Category Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) None Project: Retail 102 Title: Retail 102Tenant Improvements Type: Office (Business) Location: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200) (WEA File: Lighting Controls Compliance Acronym Ashrae Description Area No. of Design Min Compli- ID (sq.ft) Tasks CP CP ance Space 1 26 Offices (Partitions>4.5 ft below 1,000 1 2 2 PASSES ceiling) Enclosed offices, all open plan offices without partitions PASSES Project: Retail 102 Title: Retail 102Tenant Improvements Type: Office (Business) Location: PORT ST LUCIE, ST LUCIE COUNTY, FL (661200) (WEA File: System Report Compliance HVAC HVAC System Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria liance Cooling System Air Cooled < 6500.0 Btu/h 10.00 10.00 8.00 PASSES Cooling Capacity Air Handling Air Handler (Supply) - 0.75 0.80 PASSES System -Supply Constant Volume PASSES 6/26/02 EnergyGauge F1aCom FLCCSB v1.22 Plant Compliance Description Installed Size Design Min Design Min No Eff Eff IPLV IPLV Category Comp Hance None Water Heater Compliance DDesign Description Type Category Eff Min Design Max Comp Eff Loss Loss liance None Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] .SF.F] None 6/26/02 EnergyGauge F1aCom FLCCSB v1.22 !ct: Retail 102 Retail 102Tenant Improvements Office (Business) Lion: PORT S Other Required Compliance Category Section Requirement (write N/A in box if not applicable) Check Infiltration 406.1 Infiltration Criteria have been met Er System 407.1 HVAC Load sizing has been performed Ventilation 409.1 Ventilation criteria have been met ADS 410.1 Duct sizing and Design have been performed T & B 410.1 Testing and Balancing will be performed Electrical 413.1 Metering criteria have been met d Motors 414.1 Motor efficiency criteria have been met Lighting 415.1 Lighting criteria have been met O & M 102.1 Operation/maintenance manual will be provided to owner Roof/Ceil 404.1 R-19 for Roof Deck with supply plenums beneath it Report 101 Input Report Print -Out from EnergyGauge F1aCom attached? 6/26/02 EnergyGauge F1aCom FLCCSB v1.22 6 ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs EnergyGauge F1aCom v1.22 INPUT DATA REPORT Project Name: Retail 102 Project Title: Retail 102 Tenant Improvements Address: Port St. Lucie Project Information Orientation: North Building Type: Office (Business) Building Classification: New Finished building State: Florida No.of Storeys: 1 Zip: 0 GrossArea: 1000 Owner: Prima Vista Crossing Zones No Acronym Description Type Load Profile Area Multiplier Total Area [sfl [sfl 1 Zone 1 Zone 1 CONDITIONED Uses Building Load 1000.0 1 1000.0 ❑ Profile 6/25/2002 EnergyGauge FlaCom FLCCSB v1.22 1 Spaces No Acronym Description Type Depth Width Height Multi Total Area Total Volume [ft] [ft] [ft] plier [sf] [cf] In Zone: Zone 1 1 Space 1 Space 1 Offices (Partitions>4.5 ft 50.00 20.00 9.00 1 1000.0 9000.0 El below ceiling) Enclosed offices, all open plan offices without partitions Lighting No Type Power Control Type No.of [W] Ctrl pts In Zone: Zone 1 In Space: Space 1 1 Compact Fluorescent 1742.00 Manual On/Off 2 ❑ Walls No Description Type Width H (Effec) Multi Area DirectionConductance Heat Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [h.sf.FBtu] [Btu/sf.F] In Zone: Zone 1 1 North Wall 8"CMU/3/4"ISO 50.00 9.00 1 450.0 North 0.2642 9.6960 62.72 3.79 ❑ BTWN24"oc/5/8 Gyp 2 East Wall 8"CMU/3/4"ISO 20.00 9.00 1 180.0 North 0.2642 9.6960 62.72 3.79 BTWN24"oc/5/8 Gyp 3 South Wall 8"CMU/3/4"ISO 50.00 9.00 1 450.0 North 0.2642 9.6960 62.72 3.79 BTWN24"oc/5/8 Gyp 6/25/2002 EnergyGauge F1aCom FLCCSB v1.22 4 West Wall 8"CMU/3/4"ISO 20.00 9.00 1 180.0 North 0.2642 9.6960 62.72 3.79 ❑ BTWN24"oc/5/8 Gyp Windows No Description Type Shaded UCen SC Vis.Tr W H (Effec) Multi Total Area [Btu/hr sf F] [ft] [ft] plier [sf] In Zone: In Wall: El Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [lb/cf] [Btu/sf. F] [h.sf.F/Btu] In Zone: Zone 1 In Wall: South 1 Single Door Aluminum door, No 3.00 7.00 1 21.0 0.1919 43.67 0.53 5.21 ❑ 1.25 in. polystyrene In Wall: West 1 Single Door Aluminum door, No 3.00 7.00 1 21.0 0.1919 43.67 0.53 5.21 ❑ 1.25 in. polystyrene Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] [ft] plier [sf] [deg] [Btu/hr. Sf. F] [Btu/sf. F] [Ib/cf] [h.sf.FBtu] In Zone: Zone 1 1 Roof Mtl Bldg Roof/R-19 20.00 50.00 1 1000.0 0.00 0.0492 1.34 9.49 20.34 ❑ Batt 6/25/2002 EnergyGauge F1aCom FLCCSB v1.22 Skylights No Description Type UCen Shading Vis.Trans W H (Effec) Multiplier Area Total Area [Btu/hr sf F] Coeff [ft] IN [Sf] [Sf] In Zone: In Roof: Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [Btu/sf. F] [Ib/cf] [h.sf.FBtu] In Zone: Zone 1 1 Floor Concrete floor, 20.00 50.00 1 1000.0 0.5987 9.33 140.00 1.67 carpet and rubber pad Systems HVAC HVAC System Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV 1 Cooling System (Air Cooled < 65000 BftA Cooling Capacity) 2 Air Handling System -Supply (Air Handler (Supply) - Constant Volume) 60000.00 10.00 8.00 ❑ 2000.00 0.75 Plant Equipment Category Size Inst.No Eff. IPLV 6/25/2002 EnergyGauge F1aCom FLCCSB v1.22 W-Heater Description Water Heaters Capacit Cap.Unit I/P Rt. Efficienc Loss Ext-Lighting Description Categories. Area/Len/No. of units [sf/ft/No] Wattage [W] Piping No Type Operating Insulation Temperature Conductivity [F] [ Btu-in/h.sf.F] Nomonal pipe Diameter [in] Insulation Is Runout? Thickness [in] Fenestration Used Name Glass Type No. of Glass SC VLT Frame Frame Panes Conductance Conductance Absorptance [Btu/h.sf.F] [Btu/h.sf.F] 6/25/2002 EnergyGauge F1aCom FLCCSB v1.22 5 Materials Used Mat No Acronym Description Only R-Value RValue Thickness Conductivity Density SpecificHeat Used [h.sEFBtu] [ft] [Btu/h.ft.F] [lb/cf] [Btu/Ib.F] 18 Mat118 2 in. Wood No 2.3857 0.1670 0.0700 37.00 0.3900 ❑ 264 Matl264 ALUMINUM, 1/16IN No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 214 Mat1214 POLYSTYRENE, EXP., No 5.2100 0.1042 0.0200 1.80 0.2900 ❑ 1-1/4IN, 187 Mat1187 GYP OR PLAS No 0.4533 0.0417 0.0920 50.00 0.2000 ❑ BOARD,1/2IN 206 Mat1206 CELLULOSE,FILL,5.5IN,R- No 20.8318 0.4583 0.0220 3.00 0.3300 ❑ 20 151 Matll51 CONC HW, DRD, 140LB, No 0.4403 0.3333 0.7570 140.00 0.2000 ❑ 41N 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Matl265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Mat148 6 in. Heavyweight concrete No 0.5000 -0.5000 1.0000 140.00 0.2000 ❑ 123 Mat1123 CONC BLOCK No 1.7227 0.6667 0.3870 53.00 0.2000 ❑ MW,81N,HOLLOW 159 Mat1159 CONC No 0.3202 0.3333 1.0410 140.00 0.2000 ❑ HW-UNDRD-140LB-4IN 57 Mat157 3/4 in. Plaster or gypsum No 0.1488 0.0625 0.4200 100.00 0.2000 ❑ 72 Mat172 AIR LAYER, 3AIN OR Yes 0.9000 ❑ LESS, VERT. WALLS 267 Mat1267 0.75" stucco No 0.1563 0.0625 0.4000 16.00 0.2000 ❑ 266 Mat1266 2x4@16" oc + R11 Batt No 8.3343 0.2917 0.0350 9.70 0.2000 ❑ 215 Mat1215 POLYSTYRENE, EXP., No 8.3350 0.1667 0.0200 1.80 0.2900 ❑ 21N, 105 Mat1105 CONC BLK HW, 81N, No 1.1002 0.6667 0.6060 69.00 0.2000 ❑ HOLLOW 256 Mat1256 WOOD, SOFT, 1-1/21N No 1.8939 0.1250 0.0660 32.00 0.3300 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Mat142 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 86 Mat186 BRICK, COMMON, 41N No 0.8012 0.3333 0.4160 120.00 0.2000 ❑ 6/25/2002 EnergyGauge F1aCom FLCCSB v1.22 6 211 Mat1211 POLYSTYRENE,EXP.,1/2I No 2.0850 0.0417 0.0200 1.80 0.2900 ❑ N, 12 Mat112 3 in. Insulation No 10.0000 0.2500 0.0250 2.00 0.2000 ❑ 218 Mat1218 POLYURETHANE,EXP.,1/2 No 3.2077 0.0417 0.0130 1.50 0.3800 ❑ IN, 23 Mat123 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 4 Mat14 Steel siding No 0.0002 0.0050 26.0000 480.00 0.1000 ❑ 271 Mat1271 2x4@24" oc + Rl 1 Batt No 10.4179 0.2917 0.0280 7.11 0.2000 ❑ 272 Mat1272 Panel with 7/16" panels Yes 0.9044 ❑ 273 Mat1273 Hollow core flush (1.375") Yes 1.2777 ❑ 274 Mat1274 Solid core flush (1.375") Yes 1.7141 ❑ 275 Mat1275 Panel with 7/16" panels Yes 1.0019 ❑ (1.375") 276 Mat1276 Hollow core flush (1.75") Yes 1.3239 ❑ 277 Mat1277 Panel with 1-1/8" panels Yes 1.7141 ❑ (1.75") 278 Mat1278 Solid core flush (1.75") Yes 1.6500 ❑ 279 Mat1279 Solid core flush (2.25") Yes 2.8537 ❑ 280 Mat1280 Fiberglass/Mineral wool core Yes 0.8167 ❑ 281 Mat1281 Paper Honeycomb core Yes 0.9357 ❑ 282 Mat1282 Solid Urethane foam core Yes 1.6500 ❑ 283 Mat1283 Solid mineral fiberboard core Yes 1.7816 ❑ 284 Mat1284 Polystyrene core (18 ga steel) Yes 2.0071 ❑ 1 285 Mat1285 Polyurethane core (18 ga Yes 2.5983 ❑ steel) 2 286 Mat1286 Polyurethane core (24 ga Yes 2.5983 ❑ steel) 1 287 Mat1287 Polyurethane core (24 ga Yes 4.1500 ❑ steel) 2 288 Mat1288 Solid Urethane foam core Yes 4.1500 ❑ 81 Matl81 ASPHALT -ROOFING, Yes 0.1500 ❑ ROLL 244 Mat1244 PLYWOOD, 1/2IN No 0.6318 0.0417 0.0660 34.00 0.2900 ❑ 185 Mat1185 CLAY TILE, PAVER, 3/8IN No 0.0301, 0.0313 1.0410 120.00 0.2000 ❑ 82 Mat182 ASPHALT -SHINGLE AND Yes 0.4400 ❑ SIDING 11 Matll 1 2 in. Insulation No 6.6800 0.1670 0.0250 2.00 0.2000 ❑ 47 Mat147 2 in. Heavyweight concrete No 0.1670 0.1670 1.0000 140.00 0.2000 ❑ 6/25/2002 EnergyGauge FlaCom FLCCSB v1.22 " 7 95 Mat195 CONC BLOCK No 0.7107 0.3333 0.4690 101.00 0.2000 ❑ HW-4IN-HOLLOW 248 Mat1248 ROOF GRAVEL OR No 0.0500 0.0417 0.8340 55.00 0.4000 ❑ SLAG1/2IN 94 Mat194 BUILT-UP ROOFING, No 6.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/8IN Constructs Used No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [lb/cf] [h.sf.FBtul 1002 Aluminum door, 1.25 in. polystyrene No No 0.19 0.53 43.67 5.2104 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 264 ALUMINUM, 1/16IN 0.0050 0.00 ❑ .2 214 POLYSTYRENE, EXP., 1-1/41N, 0.1042 0.00 ❑ 3 264 ALUMINUM, 1/16IN 0.0050 0.00 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.Fl [Ib/cf] [h.sf.FBtul 1004 Concrete floor, carpet and rubber pad No No 0.60 9.33 140.00 1.6703 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1 151 CONC HW, DRD, 140LB, 41N 0.3333 0.00 ❑ 2 178 , CARPET W/RUBBER PAD 0.00 ❑ 6/25/2002 EnergyGauge FlaCom FLCCSB v1.22 Simple Massless Conductance No Name Construct Construct [Btu/h.sLF] 1014 8"CMU/3/4"ISO BTWN24"oc/5/8 Gyp No No 0.26 Layer Material Material Thickness No. [ft] 1 105 CONC BLK HW, 81N, HOLLOW 0.6667 2 269 .75" ISO BTWN24" oc 0.0625 3 187 GYP ORPLAS BOARD,1/2IN 0.0417 No Name Simple Massless Conductance Construct Construct [Btu/h.sf.F] 1047 Mtl Bldg Roof/R-19 Batt No No 0.05 Layer Material Material No. 1 94 BUILT-UP ROOFING, 3/8IN 2 23 6 in. Insulation Heat Capacity Density RValue [Btu/sf.F] [lb/cf] [h.sf.FBtu] 9.70 62.72 3.7856 ❑ Framing Factor. 0.00 ❑ 0.00 ❑ 0.00 ❑ Heat Capacity Density RValue [Btu/sf.F] [lb/cf] [h.sf.FBtu] 1.34 9.49 20.3366 ❑ Thickness Framing [ft] Factor 0.0313 0.00 - ❑ 0.5000 0.00 ❑ 6/25/2002 EnergyGauge F1aCom FLCCSB v1.22 9