Loading...
HomeMy WebLinkAboutCertification For Wind Load ComplianceSt. Lucie County Building and Zoning Department 2300 Virginia Avenue Fort Pierce, FL 34982 561-462-1553 Design Certification for Wind Load Compliance ' This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all applications for -building permits involving the construction of new residence (single or multi- family), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided that no structural walls, columns or other similar component is being effected) and certain other minor building permits. For further assistance, please contact the Building Inspection Office at 462-1553 or 462-2172. Project Name VOM '' ' Office Use Only Street Address 1 - — = .' e. Permit Number - L , , ,. Occupancy e - Construction Type Certification Statement: I certify,that, to the best of my knowledge and belief, these plans and specifications have been designed to comply with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. Design Parameters and Assumptions Used: lease check or complete the appropriate box.) 1. Florida Building Code 2001 Edition ASCE 7-98 2. Building Design is (check one) Enclosed Partially Enclosed Q.Building 3. Building Height: — i\% 4. Wind Speed Used in Building Design: 1,40 3 second gust 5. Wind Exposure Classification (refer to exposure tables in Building Code identified in Line #1): 6. Average Wind Velocity Pressure on Exterior Faces of Structure A% PSF 7. Peak Wind Velocity Pressure on Exterior Faces of Structure A PSF 8. Importance/Use Factor (obtain from Building Code): 6*77 9. Loads: Floor 0 PSF Roof/dead IJ 4 PSF Roof/live PSF 10. Were Shear Walls Considered for Structure (check one): Yes M_ No M&(if No, attach explanation) 11. Is a Continuous Load Path Provided. (check one): Yes No_ (if No, attach explanation) 12. Are Component and Cladding Detail Provided (check one): Yes kJANo )&(if No, -attach explanation) 13. Minimum Soil Bearing Pressure: N PSF As witnessed by my -seal, I hereby certify that the information included with this certification is.,brut correct, to the best of my knowledge and belief. Name: `►..j C�i�N C ' w"�"� Certification #:� 17s _ _ Design Firm.^'' Date: 0 FNG iNeer. S�eq l Tod Rai I 'ZXGK -o 664* P1ZC I -44 -4= lr' / Ta.P GAP &sot- ZXIfX . 6o . ALL Deck wQi lea 5/5 ALL Poles 'S IP-Aqe-d For ComPOJ'C;u ALL Poles 11-8;few. Solid Srou?48 ALL Sab S-+ructtjre. Sig N,D16. Bckted ALL h8ov'e "te r w,cod 40 ALL Pole.S a.5 M4ar� Ne SruAe Wa tareaJ lcm,? � i s -r sm •A - Water 6a%j w3rd7h -►s - f /®`?'D ic411 v //0'?®-W AocKPa4f ►*' ew A44 Aeck1b6 d,;2C6 -60 -/2a &nd /J e elc i9 rps� ; "� No a�\-ZVI G�a� pR wade �H �S0JE TaTa�s�aat2¢„ Foo1��r�GMph v'�si�iC 3a. s Se6a 3.�• S�Sef�ac�L I j:*A o � .. siitllil�ii�0"01 � O m1Co0 /a 000 ap , qjzek ,111\Mooriwg --� - 7 A8%A °