Loading...
HomeMy WebLinkAboutExtreme .032 alum HVHZ 1''BCIS Home Log In User Registration I Hot Topics � Submit Surcharge Stats &Facts Publications Contact Us i 8C[S Site Map Links Search ba `\5 Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL25621-R2 Revision U p Approved ' Extreme Metal Fabricators, LLC 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 nvalidation@yahoo.com Richard McKuhen flvalidation@yahoo.com Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluatlon Report - Hardcopy Received Florida Engineer or Architect Name who developed the David Eng Evaluation Report Florida License PE-81377 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By James R Wally, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections From the Code FL25621 R2 COI 26ga SnapMax plywood.pdf Standard TAS 100 TAS 125 U L 580 Year 1995 2003 2006 Product Approval Method Method 1 Option D Date Submitted Date Validated Date Pending FBC Approval Date Approved of Products 12/16/2020 12/17/2020 12/26/2020 02/09/2021 FL # Model, Number or Name Description 25621.1 01: 26ga SnapMax on Plywood 26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design pressure: +NIA/-97.25 Other: Refer to evaluation report Installation Instructions FL25621 R2 IT 26ga SnapMax plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621 R2 AE 26ga SnapMax piywood.pdf Created by Independent Third Party: Yes 25621.2 02: 032 Aluminum SnapMax on Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip Plywood on 15/32" (min) plywood or 3/4" wood plank Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 Other: Refer to evaluation report Instal[ation Instructions FL25621 R2 II 032 SnapMax plywood.p ff Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621 R2 AE 032 SnapMax plywood.pdf Created by Independent Third Party: Yes 25621.3 03: 032 Aluminum 12" SnapMax on Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip Plywood with 12" coverage on 15/32" (min) plywood or 3/4" wood plank Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-69.25 Other: Refer to evaluation report Installation Instructions FL25621 R2 II 032 SnapMax 12in Plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621 R2 AE 032 SnapMax 12in Plywood.pdf Created by Independent Third Party: Yes 25621.4 04: 26ga SnapMax on Plywood 26ga (min) SnapMax 1.0" nail strip on 15132" (min) plywood or 3/4" (min) wood plank Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-121.75 Other: Refer to evaluation report Installation Instructions FL25621 R2 II 26ga SnapMax plywood D.pdf Verified By: David Eng, PF 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621 R2 AE 269a SnapMax plywood D.pdf Created by Independent Third Party: Yes 25621.5 05: 26ga SnapMax on Plywood HVHZ 26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL25621 R2 II 26ga SnapMax plywood HVHZ.pdf Verified By: David Eng, PE 81377 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-176 Evaluation Reports Other: Refer to evaluation report FL25621 R2 AE 26ga SnapMax plywood HVHZ.pdf Created by Independent Third Party: Yes 25621.6 106: 24ga SnapMax on plywood 24ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ; Yes Impact Resistant: N/A Design Pressure: +N/A/-206 Other: Refer to evaluation report 25621.7 07: 032 Aluminum SnapMax on Plywood Limits of Use Approved for use in HVHZ: Ng Installation Instructions FL25621 R2 II 24ga SnapMax plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621 R2 AE 24ga SnapMax plywcod. pdf Created by Independent Third Party: Yes Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip on 15/32" (min) plywood or 3/4" wood plank Installation Instructions FL25621 R2 11 032 SnapMax plywood d.pdf Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Par : Yes Design Pressure: +N - Evaluation Reports O a uation report FL25621 R2 AE 032 SnapMax plywood d.pdf Created by Independent Third Party: Yes 25621.8 08: 032 Aluminum SnapMax on Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip Plywood HVHZ on 15/32" (min) plywood or 3/4" wood plank Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ; Yes Impact Resistant: N/A Design Pressure: +N/A/-175 Other: Refer to evaluation report 25621.9 1 09: 26ga 19" TopMax on Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5 Other: Refer to evaluation report Installation Instructions FL25621 R2 1I 032 SnapMax plywood HVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621 R2 AF 032 SnapMax plywood HVHZ.pdf Created by Independent Third Party; Yes 26ga (min) TopMax 1,5" nail strip with 19" covp on 15/32" Installation Instructions FL25621 R2 IT 269a TopMax 191n plyLiood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621 R2 AE 26ga TopMax 191n plywood.pdf Created by Independent Third Party: Yes 25621.10 10: 032 Aluminum TopMax on Nominally 0.032" aluminum (or thicker) TopMax 1.5" nail strip plywood HVHZ I on 15/32" (min) plywood or 3/4" wood plank Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-179.5 Other: Refer to evaluation report Installation Instructions FL25621 R2 11 032 TopMax plywood HVHZ.pdf Verifled By: David Fng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL25621 R2 AE 032 TopMax plywood HVHZ.pdf Created by Independent Third Party: Yes 25621.11 11: 24ga TopMax on Plywood HVHZ 24ga (min) TopMax 1.5" nail strip on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL25621 R2 II 24ga TopMax plywood HVHZ.pdf Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-153.5 Evaluation Reports Other; Refer to evaluation report FL25621 R2 „AE 24ga TopMax plywood HVHZ.pdf Created by Independent Third Party: Yes 25621.12 12, 24ga 19" TopMax on Plywood 24ga (min) TopMax 1.5" nail strip with 19" coverage on 15/32" HVHZ (min) plywood or 3/4" (min) wood plank Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL25621 R2 II 24ga TopMax 19in plywood HVHZ .pdf Verified By: David Eng, PE 81377 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-116.25 Evaluation Reports Other: Refer to evaluation report FL25621 R2 AE 24ga TopMax 19in plywood HVHZ.pdf Created by Independent Third Party: Yes 25621.13 13: 032 Aluminum 19" TopMax on Nominally 0.032" aluminum (or thicker) TopMax 1.5" nail strip plywood HVHZ with 19" coverage on 15/32" (min) plywood or 3/4" (min) wood plank Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL25621 R2 II 032 TopMax 19in plywood HVHZ.pdf Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: +N/A/-166.75 Evaluation Reports Other: Refer to evaluation report FL25621 R2 AE 032 TopMax 19in plywood HVHZ.pdf Created by Independent Third Party: Yes ars�i 6Fext Contact W :: 2601 Blair 5tane Rwa , Tallahassee FL 3Z399 Phone: 650-487-1024 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privaw Statement :: Accessibility Statement :: Refund Statement Under Florida law, ema€€ addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails 032 Aluminum (min) MAX over 15/32" (min) plywood Extreme Metal Fabricators 2160 SW Poma Dr I Palm City FL 34990 Product Description Nailstrip, snaplock style panel with a 16" maximum panel width and a nominal rib height of 1" Product Material Nominally 0.032" aluminum or thicker Fastener #10 x 1-inch pancake style fastener Compliant with FSC 1506.6 where required. Substrate/Deck 15/32" (min) plywood or 3/4" (min) thick wood plank (min S.G. of 0.42) Evaluated by: David Eng, PE Timberlake Cove, LLC 3324 W Univ Ave #206 1 Gainesville FL FL PE 81377 1 FL CA 33344 r www.TimberLakeCove.com .\\\t1111'l1111I/. MAX FL25621.08-R2 Underlayment: Comply with local building code or FBC 1507.1.1/1518.2 where required. Slope: Comply with local building code or FBC 1507.4.2/FBC 1515.2 where required - Re -Roofing: This panel may be installed over a single layer of existing shingles as permitted by local building code or FBC 1511/1521, provided the existing roof meets the conditions required by the applicable code. Fire Barrier: Comply with FBC 1516.1 and 1516.2 where required. Maximum Allowable Loads & Installation Requirements: Method A: #10 x 1" fastener at 6"__o.c. along nail strip with sealant: 175 PSF For Method A, use continuous bead of Geocel 2320 sealant or similar. A factor of safety of 2 has been applied. Fasteners are installed through the metal flange, NOT through the pre -punched slots. Technical Documentation: This product has been tested to the TAS 125 / UL 580 standard by Intertek Testing (TST-1527), report G3443.36-450-44 as referenced in FL 28059.04-RO. Compliance Statement: This product as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2 (non-HVHZ) and 1518.9.1/1523.6.5.2.4 (HVHZ), as required by FL Rule 61G20-3, method 1D. This product as described has been tested and demonstrated compliance with: • UL580 - Test for Uplift Resistance of Roof Assemblies • UL 1897 - Uplift test for roof covering systems • TAS 125 - Standard Requirements for Metal Roofing Systems • TAS 100 - Wind and Wind -Driven Rain Design Process: The load tables in this report provides one prescriptive option for the fastening requirement for the applicable wind loads for roofs within the parameters described. For roofs outside of the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or other design code in force, using allowable stress. These load tables are based on ASCE 7-16. Use of these tables assumes that the structure is: Enclosed and conforms to wind-borne debris provisions and is a regular shaped building Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a site location for which channeling or buffeting warrant consideration Engineering analysis may be completed by other licensed engineers for project specific approval by local authorities having jurisdiction. Certification of Independence: David Eng, RE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. The some entities do not have, nor will acquire, a financial interest in any other entity involved in the opproval process of the product. Exclusions and Limitations: Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by others. Fire classification and shear diaphragm design are outside the scope of this evaluation_ Accelerated weathering/salt spray is outside the scope of this evaluation. This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions, interpretations, or designs mode by others based on this evaluation report_ This report is limited solely to documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding performance of this product. Installation shall be subject to the local building code and authority having jurisdiction; this report shall not be construed to supersede local codes in force_ MAX FL2562.1.08-R2 Instructions: Select the appropriate load table that applies to the l structure in question. k Determine the design wind speed for the project a—r 3 location. 2 1 t 2 Use the attachment method indicated for that \�2�\ windspeed within each roof zone. ` 2 2 3 a 2 1 2 NOTE. ASCE 7-16 and FBC 2020 adopt a 7-zone concept. i! :`�--- 2 3 For the load tables below, the worst case was taken for each zone and reported using the standard zones %- 1 1 2 2- I 1-2-3: i / Zone 1 includes zones 1 and 1' a 3 2 31 a Zone 2 includes zones 2e, 2r, and 2n a � HIP ROOF GABLE ROOF --J a L� Zone 3 includes zones 3e and 3r Combining these zones creates a clear, simple e. 10%OF LEAST HGZONTAL—ENSION °R 0.41, —C "EVER IS$MALLER. RUI NOT LESS 7� N EITI,ER Il OF LEAST HORIZONTAL DIMENSION OR 3FT�0RM)- scheme, at the expense of some design -efficiency. °R As ER "�° R oEsl�N OR OTHER A-LII Contact the manufacturer for further information, ROOF ZONES FOR GENERIC BUILDING or consult a licensed design professional_ METHOD A FEMALE LEG SNAPS ONTO MALE LEG t SEALANT APPLIED TO +� BASE OF MALE LEG G #10FASTENER AT 6" O.G. Use this load table for structures which meet the following criteria: Are located in Exposure B area Have either a flat roof, or gable/hip roof with max slope of 12:12 Have a mean Roof Height of 30 feet or less NR-. NOT RATED CONSULT DESIGN PROFESSIONAL AS NECESSARY Use this load table for structures which meet the following criteria: Are located in B, C, or D exposure area Have either a flat roof, or gable/hip roof with max slope of 12:12 Have a mean Roof Height of 30 feet or less FL25621.08: 032 Sna Max on 15132" pl=ood FL25621.08: 032 Snal2lMax on 15132" Ulywood Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A A Zone 2: AAA AAAAAAA A Zone 2: A A A A A A A A A A Zone 3: A A A A A A A A A A A Zone 3: A A A A A A A A Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B, C, or D exposure area Have either a flat roof less than 7°, hip roof with Have either a flat roof less than 7°, hip roof with max slope of 12:12, or gable roof with slope between 4.4:12 & 12.12 max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12 Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less FL25621.08: 032 Sna Max on 15132" 12iywood FL25621.08: 032 Snal&ax on 15132" pl=ood Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A A A A A Zone 1: A A A A A A A A A A A Zone 2: A A A A A A A A A A A Zone 2: A A A A A A A A A A A Zone 3: A A A A A A A A A A A Zone 3: A A A A A A A A A JEM