FL25621-R2
Revision U
p
Approved '
Extreme Metal Fabricators, LLC
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
nvalidation@yahoo.com
Richard McKuhen
flvalidation@yahoo.com
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluatlon Report - Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By James R Wally, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections From the Code
FL25621 R2 COI 26ga SnapMax plywood.pdf
Standard
TAS 100
TAS 125
U L 580
Year
1995
2003
2006
Product Approval Method
Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
of Products
12/16/2020
12/17/2020
12/26/2020
02/09/2021
FL # Model, Number or Name Description
25621.1 01: 26ga SnapMax on Plywood 26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design pressure: +NIA/-97.25
Other: Refer to evaluation report
Installation Instructions
FL25621 R2 IT 26ga SnapMax plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 26ga SnapMax piywood.pdf
Created by Independent Third Party: Yes
25621.2 02: 032 Aluminum SnapMax on Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
Plywood on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-78.5
Other: Refer to evaluation report
Instal[ation Instructions
FL25621 R2 II 032 SnapMax plywood.p ff
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 032 SnapMax plywood.pdf
Created by Independent Third Party: Yes
25621.3 03: 032 Aluminum 12" SnapMax on Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
Plywood with 12" coverage on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-69.25
Other: Refer to evaluation report
Installation Instructions
FL25621 R2 II 032 SnapMax 12in Plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 032 SnapMax 12in Plywood.pdf
Created by Independent Third Party: Yes
25621.4 04: 26ga SnapMax on Plywood 26ga (min) SnapMax 1.0" nail strip on 15132" (min) plywood or
3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-121.75
Other: Refer to evaluation report
Installation Instructions
FL25621 R2 II 26ga SnapMax plywood D.pdf
Verified By: David Eng, PF 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 269a SnapMax plywood D.pdf
Created by Independent Third Party: Yes
25621.5
05: 26ga SnapMax on Plywood HVHZ
26ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL25621 R2 II 26ga SnapMax plywood HVHZ.pdf
Verified By: David Eng, PE 81377
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-176
Evaluation Reports
Other: Refer to evaluation report
FL25621 R2 AE 26ga SnapMax plywood HVHZ.pdf
Created by Independent Third Party: Yes
25621.6 106: 24ga SnapMax on plywood 24ga (min) SnapMax 1.0" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ; Yes
Impact Resistant: N/A
Design Pressure: +N/A/-206
Other: Refer to evaluation report
25621.7 07: 032 Aluminum SnapMax on
Plywood
Limits of Use
Approved for use in HVHZ: Ng
Installation Instructions
FL25621 R2 II 24ga SnapMax plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 24ga SnapMax plywcod. pdf
Created by Independent Third Party: Yes
Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
on 15/32" (min) plywood or 3/4" wood plank
Installation Instructions
FL25621 R2 11 032 SnapMax plywood d.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Par : Yes
Design Pressure: +N - Evaluation Reports
O a uation report FL25621 R2 AE 032 SnapMax plywood d.pdf
Created by Independent Third Party: Yes
25621.8 08: 032 Aluminum SnapMax on Nominally 0.032" aluminum (or thicker) SnapMax 1.0" nail strip
Plywood HVHZ on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ; Yes
Impact Resistant: N/A
Design Pressure: +N/A/-175
Other: Refer to evaluation report
25621.9 1 09: 26ga 19" TopMax on Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-63.5
Other: Refer to evaluation report
Installation Instructions
FL25621 R2 1I 032 SnapMax plywood HVHZ.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AF 032 SnapMax plywood HVHZ.pdf
Created by Independent Third Party; Yes
26ga (min) TopMax 1,5" nail strip with 19" covp on 15/32"
Installation Instructions
FL25621 R2 IT 269a TopMax 191n plyLiood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 26ga TopMax 191n plywood.pdf
Created by Independent Third Party: Yes
25621.10 10: 032 Aluminum TopMax on Nominally 0.032" aluminum (or thicker) TopMax 1.5" nail strip
plywood HVHZ I on 15/32" (min) plywood or 3/4" wood plank
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-179.5
Other: Refer to evaluation report
Installation Instructions
FL25621 R2 11 032 TopMax plywood HVHZ.pdf
Verifled By: David Fng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL25621 R2 AE 032 TopMax plywood HVHZ.pdf
Created by Independent Third Party: Yes
25621.11 11: 24ga TopMax on Plywood HVHZ 24ga (min) TopMax 1.5" nail strip on 15/32" (min) plywood or
3/4" (min) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL25621 R2 II 24ga TopMax plywood HVHZ.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-153.5 Evaluation Reports
Other; Refer to evaluation report FL25621 R2 „AE 24ga TopMax plywood HVHZ.pdf
Created by Independent Third Party: Yes
25621.12
12, 24ga 19" TopMax on Plywood
24ga (min) TopMax 1.5" nail strip with 19" coverage on 15/32"
HVHZ
(min) plywood or 3/4" (min) wood plank
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL25621 R2 II 24ga TopMax 19in plywood HVHZ .pdf
Verified By: David Eng, PE 81377
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-116.25
Evaluation Reports
Other: Refer to evaluation report
FL25621 R2 AE 24ga TopMax 19in plywood HVHZ.pdf
Created by Independent Third Party: Yes
25621.13 13: 032 Aluminum 19" TopMax on Nominally 0.032" aluminum (or thicker) TopMax 1.5" nail strip
plywood HVHZ with 19" coverage on 15/32" (min) plywood or 3/4" (min) wood
plank
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL25621 R2 II 032 TopMax 19in plywood HVHZ.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-166.75 Evaluation Reports
Other: Refer to evaluation report FL25621 R2 AE 032 TopMax 19in plywood HVHZ.pdf
Created by Independent Third Party: Yes
ars�i 6Fext
Contact W :: 2601 Blair 5tane Rwa , Tallahassee FL 3Z399 Phone: 650-487-1024
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privaw Statement :: Accessibility Statement :: Refund Statement
Under Florida law, ema€€ addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
032 Aluminum (min) MAX over 15/32" (min)
plywood
Extreme Metal Fabricators
2160 SW Poma Dr I Palm City FL 34990
Product Description
Nailstrip, snaplock style panel with a 16" maximum panel width and a
nominal rib height of 1"
Product Material
Nominally 0.032" aluminum or thicker
Fastener
#10 x 1-inch pancake style fastener
Compliant with FSC 1506.6 where required.
Substrate/Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of 0.42)
Evaluated by:
David Eng, PE
Timberlake Cove, LLC
3324 W Univ Ave #206 1 Gainesville FL
FL PE 81377 1 FL CA 33344
r www.TimberLakeCove.com
.\\\t1111'l1111I/.
MAX
FL25621.08-R2
Underlayment: Comply with local building code or FBC 1507.1.1/1518.2 where required.
Slope: Comply with local building code or FBC 1507.4.2/FBC 1515.2 where required -
Re -Roofing: This panel may be installed over a single layer of existing shingles as permitted
by local building code or FBC 1511/1521, provided the existing roof meets the conditions
required by the applicable code.
Fire Barrier: Comply with FBC 1516.1 and 1516.2 where required.
Maximum Allowable Loads & Installation Requirements:
Method A: #10 x 1" fastener at 6"__o.c. along nail strip with sealant: 175 PSF
For Method A, use continuous bead of Geocel 2320 sealant or similar.
A factor of safety of 2 has been applied.
Fasteners are installed through the metal flange, NOT through the pre -punched slots.
Technical Documentation:
This product has been tested to the TAS 125 / UL 580 standard by Intertek Testing (TST-1527),
report G3443.36-450-44 as referenced in FL 28059.04-RO.
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020,
1504.3.2 (non-HVHZ) and 1518.9.1/1523.6.5.2.4 (HVHZ), as required by FL Rule 61G20-3, method 1D.
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems
• TAS 125 - Standard Requirements for Metal Roofing Systems
• TAS 100 - Wind and Wind -Driven Rain
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16.
Use of these tables assumes that the structure is:
Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
Certification of Independence:
David Eng, RE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company
manufacturing or distributing products under this evaluation. The some entities do not have, nor will
acquire, a financial interest in any other entity involved in the opproval process of the product.
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by
others. Fire classification and shear diaphragm design are outside the scope of this evaluation_ Accelerated
weathering/salt spray is outside the scope of this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by
Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions,
interpretations, or designs mode by others based on this evaluation report_ This report is limited solely to
documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding
performance of this product. Installation shall be subject to the local building code and authority having
jurisdiction; this report shall not be construed to supersede local codes in force_
MAX
FL2562.1.08-R2
Instructions:
Select the appropriate load table that applies to the l
structure in question. k
Determine the design wind speed for the project a—r 3
location.
2 1 t 2
Use the attachment method indicated for that \�2�\
windspeed within each roof zone. ` 2 2 3 a
2 1 2 NOTE. ASCE 7-16 and FBC 2020 adopt a 7-zone concept. i! :`�--- 2 3
For the load tables below, the worst case was taken
for each zone and reported using the standard zones %- 1 1 2
2- I
1-2-3: i /
Zone 1 includes zones 1 and 1' a 3 2 31 a
Zone 2 includes zones 2e, 2r, and 2n
a � HIP ROOF GABLE ROOF --J a L�
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear, simple e. 10%OF LEAST HGZONTAL—ENSION °R 0.41, —C "EVER IS$MALLER. RUI NOT
LESS 7� N EITI,ER Il OF LEAST HORIZONTAL DIMENSION OR 3FT�0RM)-
scheme, at the expense of some design -efficiency. °R As ER "�° R oEsl�N OR OTHER A-LII
Contact the manufacturer for further information, ROOF ZONES FOR GENERIC BUILDING
or consult a licensed design professional_
METHOD A
FEMALE LEG SNAPS
ONTO MALE LEG
t SEALANT APPLIED TO
+� BASE OF MALE LEG
G
#10FASTENER
AT 6" O.G.
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Have either a flat roof, or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
NR-. NOT RATED
CONSULT DESIGN
PROFESSIONAL AS
NECESSARY
Use this load table for structures which meet the following criteria:
Are located in B, C, or D exposure area
Have either a flat roof, or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
FL25621.08: 032 Sna
Max on 15132" pl=ood
FL25621.08: 032 Snal2lMax
on 15132" Ulywood
Wind
105
110 120
130
140
150
160 170
180 190 200
Wind
105 110
120
130
140 150 160 170
180 190 200
Zone 1:
A
A A
A
A
A
A A
A A A
Zone 1:
A A
A
A
A A A A
A A A
Zone 2:
AAA
AAAAAAA
A
Zone 2:
A A
A
A
A A A A
A A
Zone 3:
A
A A
A
A
A
A A
A A A
Zone 3:
A A
A
A
A A A A
Use this load table for structures which meet the following criteria:
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Are located in B, C, or D exposure area
Have either a flat roof less than 7°, hip roof with
Have either a flat roof less than 7°, hip roof with
max slope of 12:12, or gable roof with slope between 4.4:12 & 12.12
max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12
Have a mean Roof Height of 30 feet or less
Have a mean Roof Height of 30 feet or less
FL25621.08: 032 Sna Max on 15132" 12iywood
FL25621.08: 032 Snal&ax on 15132" pl=ood
Wind 105 110 120 130 140 150 160 170
180 190 200
Wind 105 110 120 130 140 150 160 170
180 190 200
Zone 1: A A A A A A A A
A A A
Zone 1: A A A A A A A A
A A A
Zone 2: A A A A A A A A
A A A
Zone 2: A A A A A A A A
A A A
Zone 3: A A A A A A A A
A A A
Zone 3: A A A A A A A A
A JEM